Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.4 L+₹1.7 L (4.17%)Rejected-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-AOC L2 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
28 Jul 2023, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No 2 Jodhpur
Repairs to plastering flooring plumbing sanitary fittings and misc b/R items in Md Accn under AGE BR-II GE AF No 2 Jodhpur
2023_MES_607015_1
8408/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) No 02 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹80,000
Yes
9 Aug 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
28 Jul 2023
15 Jul 2023
30 Jun 2023 - 7 Jul 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
M&L for dismantling floor heart or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and com[plete all as specified.
Taking down chowkats or frame with shutter (without taking off shutters from the frames) n exc 1.5 Sqm complete all as specified and as directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frames) exc 1.5 Sqm and n exc 4.00 sqm each of any description incl making good the disturbed surfaces complete all as spd and as directed.
Taking down shutters of any description exc 1 sqm & n exc 2 sqm each and refixing in Same opening after doing suitable repairing hinges etc or as directed by Engr-In-charge
Material and labour for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in levelling courses laid and compacted in slope in floor complete all as specified and as directed.
M&L for light coloured Vitrified Ceramic tiles 9-10 mm thick area of each tiles not less than 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:6.
All as per item No. 7.00 above but on vertical surfaces such as dados, skirtings and risers to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces.
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. (square/rectangular) area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6
M&L for glazed ceramic tiles, coloured, 450x350x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm rendering in 1:4 cement mortar complete all as specified & as directed
S&F in repairs, EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified.
S&F in repairs vitreous- China wash down water closet Squatting pan ( Orissa Pattern) size 580 x 440 mm including flush pipe , PVC P-trap and PCC for fixing complete all as specified and as directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm.
S & F in repairs brass waste coupling of 32 mm dia for WHB all as specified and as directed
S & F PVC waste pipe 32mm bore of suitable length for WHB/Urinsl/sink complete all as specified and as directed
S&F in repair CP soap dish, fixed to plugs with chromium plated screws and all as specified.
S&F in repair CP tubular towel rail, 20 mm dia, D type, 60 cm long between flanges and all as specified
S&F in repair CP grating 100 mm dia all as specified and as directed.
S&F Single mirror bath room cabinet moulded body and frame (made of strong and fine quality A.B.S plastic) with hinged door (size 16"x12"6") white/ivory in colour.
S&F in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long
Taking up or down 15 mm dia steel tubing and connection and removal from site complete all as specified and as directed
Taking up or down 20 mm dia steel tubing and connection and removal from site complete all as specified and as directed
S & F 15 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
S & F 20 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
S&F in repair stop/gate valves/angle valves cast copper alloy CP fancy type screwed down high pressure with crutch or butterfly handle for 15mm bore.
S&F in repair 15mm bib taps cast copper alloy CP Fancy type with crutch or butterfly handle screwed down for iron pipe or for brass ferrule.
S&F in repair 15mm Pillar taps cast copper alloy, capstan heads CP Fancy type with crutch or butterfly handle screwed down for iron pipe or for brass ferrule.
S&F in repair Brass chromium plated shower rose 125mm size with arm
Dismantling of existing water tank (PVC/RCC/AC) exc 250 ltr but n exc 500 ltr capcity and removing from site complete as directed by Engr -in-charge.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete in repair.
Dismantling of existing water tank (PVC/RCC/AC) exc 500 ltr but n exc 1000 ltr capcity and removing from site complete as directed by Engr -in-charge.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete in repair.
Disconnecting existing water tanks exc 500 ltrs but n exc 1000 ltrs cap setting aside (or lowering if required) for repair cleaning etc and hoisting if required reconnecting and refixing in position. (cleaning repairing etc measured separartely) complete all as spd.
Disconnecting existing water tanks exc 250 ltrs but n exc 500 ltrs cap setting aside (or lowering if required) for repair cleaning etc and hoisting if required reconnecting and refixing in position. (cleaning repairing etc measured separartely) complete all as spd.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 100 mm dia and complete all as specified and directed by Engr-in-Charge.
S&F in repair 75 mm bore UPVC (SWR) pipes type ‘A’, single socketed, in any length with rubber ring joints fixed to walls and complete all as specified and directed by Engr-in-Charge.
S&F in repair 75 mm bore UPVC (SWR) pipes type ‘A’, single socketed, in any length with laid in trenches or in floors
S&F in repair PVC (SWR) door bends 75mm dia with access door and complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR), junction single, (Single T) equal or unequal 75mm with acess door and complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) floor trap with garting of outlet dia 75mm incl jointing with solvent cement and complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F in repair PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed in walls and complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR), junction single, (Single T) with acess door 110 mm dia equal or unequal and complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) door bends 110 mm dia with acess door and complete all as specified and directed by Engr-in-Charge.
S&F in repair 110 mm dia PVC WC connector with lip ring complete all as specified and directed by Engr-in-Charge.
Resecuring or easing & adjusting without taking down shutters of any description exc. 1 sqm but n. exc. 2 sqm each and complete all as specified and directed by Engr-in-Charge.
S&F steel windows with side hung shutters including projecting type hinges sith steel handle and steel peg stay , complete with glazing bars, dovetailed or welded. (Note : One AC vent of size 0.70 mtr x 0.50 mtr with top hung shutter will be provided)
All as per item No 49 above but without glazing bars complete all as specified and directed.
S&F framed work such as grills gratings etc with ends of bars shoulders and/or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings frame work of water tanks and similar works conforming to Fe 290 gde E-165.
S&F galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surface of any description not otherwise provided over 10 cm width or girth and applying two coats of synthetic enamel paint and complete.
S&F in repairs stainless steel curatin rod , having outer dia 25 mm including stainless steel fixing brackets all as directed by Engineer-in-Charge.
S&F in repairs Stainless Steel cap for curtain rod for 25mm dia curtain rod as directed by Engineer-in-Charge.
S&F in repairs galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples
Welding in repairs exc 2.5 cm & n exc 5 cm in length & thickness of metal n.exc 6 mm all as specified and directed by Engr-in-charge
S&F in repairs floor door stopper, with 150 mm long, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor.
S&F in solid rubber beading of 30 to 50 mm wide and 3 to 5 mm thick fixing at bottom to existing doors all as directed by Engineer-in-Charge.
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beading in square n.exc. 0.5 sqm in each paneand complete all as specified.
S&F sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square n.exc. 0.5 sqm in each paneand complete all as specified.
M&L for powder coated anodised aluminium frame for door window & ventilator with one or more rebates including joining cleat for fixing etc comlete all as specified.
S&F powder coated louvers with including arrangement of fixing glass pinhead as per size & louvers ventilator (Glass shall be measurement separately) complete all as specified and as diredcted.
Material and labour for water proofing treatment of sunken floor of WCs, bathroom etc. by applying of the following specifications :- (i) Cleaning of sunken floor surface with mechanical means i.e. wire brush/air blower etc. and remove all loose/unsound material, dirt, dust, etc.(ii) Applying cement slurry mixed with acrylic based polymer modified cementitious composite compound coating Hydroproof Xtra of FOSROC/Equivalent of Dr Fixit of Pidilite Industries Ltd in the ratio of 1:2:4 (One part of acrylic polymer : Two part of water and four part of cement).(iii) First layer of cement slurry @ 0.444 Kg/Sqm mixed with acrylic based modified cementious composite compound @ 0.222 Litre/Sqm and allow it to air dry for 04 hours.(iv) Second layer of cement slurry @ 0.222 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.111 Litre/Sqm and allow it to air dry for 04 hours followed with water curing for 48 hours.(v) 200 micron thick polythene film shall be pasted with help of adhesives over treatment.Note :- Joints of WC/Trap/Soil waste shall be properly sealed with sealing compound. Testing of all traps and joint and sunken slab shall be done as per IS-1742 before filling and tiling work.
Material and labour for plain cement concrete 1:5:10 type E-2 (using 40mm graded broken bricks aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed.
M & L for 75mm thick Plain Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) complete all as specified and directed by EIC.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, set and jointed in CM (1:4) with grey cement and With pigment complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate as in coping , including necessary form work complete all as specified and directed.
Complete removal of existing treatment surface of walls and applying two coats of wheather proof exterior emulsion paint complete all as specified and all as directed
M&L for preparation of old plastered or unplastered surfaces of walls and applying one coat of white wash.
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash.
M&L for preparation of old surfaces (plastered or unplastered) of walls including removing/scrapping down existing surface where ever necessary and applying two coat of oil emulsion distemper over two coat of wall care putty complete all as specified & directed.
Dismantling of existing treatment of roof surface and Wire brushing , cleaning top surfaces of tarrace or cement concrete including flashing and junction of parapets complete all as specified and directed by Engr-in-Charge.
M&L for one coat of applied cold bituminous primer @ 0.5 kg/Sqm shall be applied on plastered surfaces including side wall all as specified and directed.
M&L 10 mm thick plaster with CM 1:4 with water proofing compound @ 3% by weight of cement finish even and smooth surfaces using without extra cement. Water proofing compound shall be measured and paid seperately & complete all as specified and directed by Engr-in-Charge.
M/L for cement concrete B-1. 1:2:4 (20mm graded aggregate) in padding finishing surface of concrete topping even and fair without using extra cement all as specified of average thickness 50 mm in slop 1:40 over roof & complete all as specified and directed by Engr-in-Charge.
M/L APP modified membrane minimum weighting 3 Kg/Sqm with polyster non woven polyster reinforcement ( weight not less than 150 gms/sqm )shall be laid by torch application method and overlapped by 100 mm in all sides as directed by Engr-in-Charge
S&F in repairs for center hole basin mixer without popup waste system and complete all as directed by Engr-in-charge
S&F in repairs for sink mixer with regular spout w/m and complete all as directed by Engr-in-charge
S&F in repairs for wall mixer with bend, and complete all as directed by Engr-in-charge
M&L for poviding and injecting chemical emulsion for post construction anti termite treatment along external wall where the apron is not proving using chemical emulsion at theart of 7.5 ltr per sqm of the vertical surface of the sub structure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified and directed.
M&L for treatment of soil under existing floors using emulsion @ one litres per hole 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors and all as specified and directed.
S&F factory made solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet reinforced with mS square tube etc complete all specified.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified & directed.
Supply and fixing stainless steel butt hinges medium weight , clod rolled, 100mm, ISI marked, complete all as specified & directed.
Material & Labour stainless steel barrel tower bolts aluminium anodised extruded section of size 200 mm complete all as specified & directed.
Supply and fixing stainless steel fabricated type extruded handles of size 150 mm complete all as specified & directed.
M&L for granite (of any type) tiles 20 mm thick machine cut in skirting/dado over and including 15mm thick rendering in CM 1:6 on stone masonry surfaces, jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engr-in-Charge.
S & F sinks with drainage boards made of stainless steel 1 mm thick kitchen or laboratory with plugs,washers and wastes,including bedding in cement mortar o to dwarf wall or including fixing cantilver brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engr-in-Charge.
VIKAS CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .