Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.8 L+₹1.8 L (6.23%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹31.8 L+₹2.8 L (9.77%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹36.9 L+₹7.9 L (27.2%)Rejected-AOC 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹37.1 L+₹8.1 L (27.9%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L5 | Rejected-AOC Not Lowest |
Tender Value
₹31.1 L
EMD Value
₹62,300
Closing Date
3 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HILLS DEHRADUN
HQ CWE HILLS, MALL ROAD, DEHRADUN CANTT- 248003.
AUGMENTATION OF ELECTRIC SUP TO CATER FOR ADDL LOAD REQUIREMENT AT GE CLEMENT TOWN.
2023_MES_631624_1
85400/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE CLEMENT TOWN
Class D Category b(ii)
6 documents required · 6 mandatory
₹500
GE Clement Town
₹62,300
Yes
7 Mar 2024
7 Dec 2023
10 Jan 2024
7 Dec 2023
3 Jan 2024
22 Dec 2023
Amount
Supply, installation testing and commissioning of transformers 400 KVA copper wounded distribution type 11 KV/433V, 3 phase, 4 wire LT output, 50 Hz, AN, Dn11, suitable for outdoor installation, with off-load tap changer with steps ±2.5% up to ±7.5% on HT side all technical specification comprising to IS 1180 (Part-I&II) of 2014, Energy efficient level-III, at no load, oil immersed naturally cooled with external cooling tubes/fins core type, Delta connection on primary (HV side) in accordance with vector group DY-11 with neutral brought on secondary (LV side) with all necessary standard fittings and accessories complete after necessary testing after completion with the following specifications: -
Standard KVA rating: - 400 KVA, Primer Voltage: - 11000V AC, Secondary Voltage: - 433 V AC,Neutral earthing should be solidly earth system,Frequency: - 50 Hz with ±3% tolerance, Vector Group: - DYn11,Percentage impedance: - 5% at 75 deg C (subject to IS tolerance), Average temperature rise shall not exceed to 65deg C and max temperature rise of the windings shall not exceed to 115 DegC.,The core shall be of High grade Cold Rolled Grain oriented (CRGO) annealed steel lamination, having low loss and good grain properties, coated with "A" class grade insulations, bolted together firmly to the frames to prevent vibrations and noise. HV and LV coils should be with electrolytic copper windings, with "A" class grade insulation on HV windings and necessary spacers and air duct for cooling.,The losses at the rated voltage should be within the specified limit as per IS-1180,The transformer enclosure should be with robust construction and shall be built of electrical welded MS sheet wire mesh or perforated sheet for ventilation, with lifting lugs, pulling lugs, top cover fixing bolts, rollers and enclosure base channels.The necessary HT and LT bushing as per IS 3347 and amended up to date, HT & LT terminals for cable connection shall be brought through side wall mounted bushing to a cable box with necessary cable entry and glands fixed on both side. Transformer should have necessary terminal marking plates and rating plates. The following standard fittings/accessories to be supplied alongwith transformer and deemed included in quoted rate :-
HT bushing suitable for 11 KV complete with all accessories housing in sheet steel enclosure - 03 nos.
LT bushing suitable for 1100V complete with all accessories housing in sheet steel enclosure - 04 nos.
Oil conservator with filter type drain valve and oil level gauge.
Dehydrating breather with first fill dehydrating agent.
Explosive vent.
Thermometer pocket on tank cover.
One number 100mm dial type thermometer, vapour pressure type , having range 0-120 degree centigrade with maximum reading pointer, Max. temperature indicator and resting device.
Rating plate with terminal marking.
Two Nos. earthing, terminals on tank and cover to facilitable fixing of 32mm x 6 mm strip.
Oil level gauge.
Oil drain filter valve.
Lifting lugs 02 Nos.
Oil filter hole with cap /plug with connection complete.
Air release valve plug.
Four plain solid cast steel detachable rollers.
First fill of fresh transformer oil conforming to relevant I.S. and tested upto 40 KV dielectric strength.
Name raitng and diagram plate.
Arching horn set.
Platform of Size 3.5 x 3.5 x 1.2m height from ground level with stairs including excavation, PCC 1:5:10 type E2 in foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plastering 10mm thick in CM 1:6 on brick/concrete surface and on top covered with GI chain link fencing 1.20m high gate of mesh size 50 x 50mm and GI wire dia 3.15mm incl suitable size of angle Iron, nuts & Bolts etc. and deemed included unit rate quoted by contractor against this item of transformer.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for HT 11000 Volt system, cross sectional area 95 Sqmm 3 core laid in trenches/ pipes/ ducts/ wall/ borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete as per IS-7098(Part-I)-1988 complete all as specified and as directed. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
Supplying, laying, jointing, testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) of following cross sectional area size with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches, fixed to pole complete all as specified and directed :- Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
Size 300 Sqmm 3.5 Core
Size 240 Sqmm 3.5 core
Size 150 Sqmm 3.5 core
Size 120 Sqmm 3.5 core
Size 95 Sqmm 3.5 core
Size 25 Sqmm 4 core
Size 16 Sqmm 4 core
Excavation in trenches in any type of soil and n'exc 1.5 m wide and n'exc 1.5 m in depth for laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level complete all specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thickness of sand will be measured and paid.
M&L for un-reinforced precast concrete cable cover class HVP, type 1 with peak size 300mm x 180mm x 40mm compliance with IS:5820-1970, as cable protection over sand cushioning perpandicular across the cable length wise in trenches complete all as specified and directed.
M&L for un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm compliance with IS:5820-1970, as cable protection over sand cushioning perpandicular across the cable length wise in trenches complete all as specified and directed.
Returning, filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, in any tupe of soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
(A) BUS BAR CHAMBER :- Aluminium Bus bar chamber rating : 800 Amps, TPN, 415V. (B) INCOMING :- ACB rating : 630 Amps, 4P, 415V, 50KA, -01 (C) OUTGOING :- (i) MCCBs rating : 400 Amps, 4P, 36 KA -01, (ii) MCCBs rating : 200 Amps, 4P, 36 KA - 02, (iii) MCCBs rating : 160 Amps, 4P, 25 KA - 01, (iv) MCCBs rating : 100 Amps, 4P, 25 KA - 02. NOTE : (i) All the MCCB with Rotary Mechanism Handle and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box. (iii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor. (iv) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and tested, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 800 x 600 x 500mm having bus bar chamber with insulated electrolytic aluminium bus bars installed on DMC insulators. The panel shall be dust and vermin proof, protection class (IP-54) in accordance with IS-2147. b) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5mm thick and 450 mm long), front & rear opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrument chamber with RYB indicator LED lamps. The scope of work also comprising of the following:-
(A) BUS BAR CHAMBER :- Aluminium Bus bar chamber rating : 300 Amps, TPN, 415V. (B) INCOMING :- MCCB rating : 200 Amps, 4P, 25 KA - 01 NOTE : (i) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 1000X600X500 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus bars installed on DMC insulators . The panel shall be dust and vermin proof, protection class (IP-54) in accordance with IS-2147. b) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5mm thick and 450 mm long), front & rear opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrument chamber with RYB indicator LED lamps. The scope of work also comprising of the following:-
(A) BUS BAR CHAMBER :- Aluminium Bus bar chamber rating : 600 Amps, TPN, 415V. (B) INCOMING :- MCCB rating : 400 Amps, 4P, 36 KA - 01 NOTE : (i) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
S&F including installation, testing and commissioning of Lighting Arresters expulsion type, distribution class with all fittings arrangements suitable to 11000 volts grade and discharge capacity 65KA with and including lighting counter and cable of suitable size and core from lightning arrestor to ligting counter complete all as specified & directed.
S&F gang operated air breaker switch, triple pole, mechanically operated, mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 amps, out door type (confirming to IS specifications) HT 11 KV, triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse Assembly, Fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with pad lock arrangement complete all as specified and as directed.
M&L for MS cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed.
S&F danger notice plate of 25x20 Cm size and 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts complete all as specified and directed.
S&F earth continuity conductor or main earthing lead of aluminium strip 25 x 3.15mm with saddles, fixed to HT poles at site with and including fixing screws etc complete all as specified and directed.
M&L for 110mm bore dia HDPE pipe suitable for 5/6 kgf/cm square working pressure with all fittings, laid in trenches for protection of cable in road/ drain crossing/ On HT pole complete all as specified and directed.
Supplying, transporting, erection & fixing of new steel tubular swaged poles type 410 SP-55, (11.00 metres long), with cast iron base plate 6mm thick, finial taper plug, bolts, nuts and screws complete as specified with and including two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embeded in PCC with and including all necessary excavation & earth work in any type of soil for foundation of poles (Pit size 1.2 x 0.6m), PCC 1:3:6 type 'C2' (using 40 mm graded stone aggregate ) in foundations of size 600 X 600 X 1985 mm below GL, PCC 1:2:4 type "B2' (using 20 mm graded stone aggregate) in plinth block (coping) of size 600 X 600 X 300 mm above GL, removing surplus soil to a distance n'exc. 50 m & depositing where directed, and writing numbers of poles in 100 mm dia yellow colour circle with black paint including 30 cm wide alternate black bands (03 Nos) upto 1.5 height from top of coping complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 25x4 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009) with conected to eath test point including adequate quantity of charcoal dust and comman salt, PCC (1:3:6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for watering and 32mm dia medium earth lead protection pipe complete all as specified and directed. Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor.
Ansh Enterprises
TRINITY CONSTRUCTION
HUMERS INFRATECH
M/s Kamal Traders
RAMAPATI ENGINEERING SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .