Loading…
Loading…
Tender Value
₹80.6 L
EMD Value
₹50,000
Closing Date
10 Jun 2026, 3:00 pm4d left
Executive Engineer
O/o Executive Engineer PWD Building Division Alp.
GENERAL-Govt.Model H.S.S AmbalappuzhaConstruction of New Building for Govt.Model H.S.S Ambalappuzha-General Civil Work retender
2026_PWD_844781_2
PWD/BLDG/TR/15220/2023_5_1_1/1
Open Tender
Civil Works - Buildings
540 days
Alappuzha District
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
4 Jun 2026
4 Jun 2026
12 Jun 2026
4 Jun 2026
10 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Detailed Estimate | ||||||
| 1.001 | OD205317/2025-2026:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured up to bottom of pile cap).700 mm dia piles. Excess or less cement used as per design mix specified in subdata 5.33.1.2 is not payable or not recoverable separately.(Observed data from Item No. 20.2.3 and 5.33.1.2) | - | metre | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 20.6.2.1:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Single pile above 50 tonne and upto 100 tonne capacityInitial test (Test Load 2.5 times the Safe capacity) | - | per test | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity) | - | per test | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 0.8 | cum | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m | - | sqm | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete | - | hour | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 1 | cum | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | OD104053/2025-2026: Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is not payable or not recoverable separately. All work up to plinth level. | 0.6 | cum | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | - | kilogram | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
preliminaryagt.pdf
Tender Documents • 0.21 MB
affidavit.pdf
Tender Documents • 0.02 MB
epay.pdf
Tender Documents • 0.14 MB
tenderform.pdf
Tender Documents • 0.56 MB
nit.pdf
Tender Documents • 0.03 MB
BOQ_1443581.xls
BOQ • 0.32 MB
sbd.pdf
Tender Documents • 3.70 MB
Download all tender documents and submit your bid