Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-Finance 339 2 8 KALIPADA MUKHERJEE ROAD BARISHA KOLKATA 700 008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | ₹5.0 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹5.3 LAccepted-Finance | ₹5.3 L | L2 | Accepted-Finance Accepted |
| 3 | L3₹5.5 LAccepted-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹5.5 L | L3 | Accepted-Finance Accepted |
| Sl No | Description | Qty | Unit | Lyric International L3 | UNIVERSAL SALES L2 | AEROCON INDUSTRIES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery of 2.0 TR new split type air conditioning machine along with remote & fitted with rotary compressor, copper coil designed to operate on 230V +/- 5%, 50 Hz, single phase AC supply. At ISI condition the machine is rated for a capacity of 24000 BTU/Hr. Star rating at least 3 (Refrigerant R32/green gas). Make- Mitsubishi/ Blue Star / Carrier/ Hitachi/Daikin. | 4 | No. | 52,000 ₹2.1 L | 54,000 ₹2.2 L | 48,000 ₹1.9 L |
| 2.00 | Supply & delivery of 1.5 TR new split type air conditioning machine along with remote & fitted with rotary compressor, copper coil designed to operate on 230V +/- 5%, 50 Hz, single phase AC supply. At ISI condition the machine is rated for a capacity of 18000 BTU/Hr. Star rating at least 3 (Refrigerant R32/green gas). Make- Mitsubishi/ Blue Star / Carrier/ Hitachi/Daikin. | 2 | No. | 38,500 ₹77,000 | 39,000 ₹78,000 | 35,000 ₹70,000 |
| 3.00 | Installation, testing & commissioning charges for 1.5 / 2.0 TR capacity Split type Air conditioner with standard angle structure for installation of ODU as per instruction of site Engineer. (Including necessary dismantling of old AC machine). | 6 | No | 1,950 ₹11,700 | 2,600 ₹15,600 | 2,950 ₹17,700 |
| 4.00 | Supply & laying of refrigeration copper pipe (suction & discharge) with thermal insulation along with cable Outdoor to Indoor Unit suitable for 1.5TR / 2TR Split Air Conditioner. Approx. distance between ODU to IDU 30 ft. | 6 | No. | 13,500 ₹81,000 | 5,800 ₹34,800 | 6,500 ₹39,000 |
| 5.00 | Supply & laying hard PVC water pipe for condensate water drain as recommended. | 90 | Mtr | 85 ₹7,650 | 150 ₹13,500 | 160 ₹14,400 |
| 6.00 | Supply, installation, testing & commissioning of 4TR capacity Cassette Split Unit (R-410A) Air Conditoner, 3-phase, 415 volt +/- 10%, 50 Hz AC supply, Scroll compressor, having cordless Remote with refrigerant pipes etc. Make- Mitsubishi/ Blue Star / Carrier/ Hitachi/Daikin. CAT no. shall be specified along with technical literature. The cost shall be inclusive of modification required for installation of new AC machine along with necessary copper piping, insulation, electrical cabling between IDU & ODU , supply & charging of R-410A or equivalent HFC refrigerant gas, necessary supporting arrangements for both indoor & outdoor unit, painting of supporting structure etc complete. No hidden cost allowed. | 1 | No. | 1,30,500 ₹1.3 L | 1,30,000 ₹1.3 L | 1,16,500 ₹1.2 L |
| 7.00 | Supply, installation & testing of refrigerant piping with Suction line & Liquid line pipe providing OEM recommended hard / soft drawn copper refrigeration pipelines including necessary fittings, support, fixing etc. & brazing arrangement. Providing necessary Ball isolation valves, Expansion valves, Driers etc. are to be installed as required / recommended. Proper leak testing of entire refrigeration pipelines with dry nitrogen. The suction & liquid line shall be insulated with 9 mm thick Sleeveless nitrile rubber insulation. (For 4TR capacity Cassette Split Unit). | 30 | Mtr | 670 ₹20,100 | 900 ₹27,000 | 1,175 ₹35,250 |
| 8.00 | Supply, fabrication and installation of MS base frame for outdoor units with applying of single coat red oxide primer & double coat Black Japan paint. (For 4TR capacity Cassette Split Unit). | 1 | No. | 4,500 ₹4,500 | 6,000 ₹6,000 | 5,000 ₹5,000 |
| 9.00 | Supply and laying of 32 mm dia PVC condensate drain pipe from indoor to the nearest drain point complete with elbows, U traps & insulations. (For 4TR capacity Cassette Split Unit). | 15 | Mtr | 135 ₹2,025 | 140 ₹2,100 | 210 ₹3,150 |
| 10.00 | Supply & installation of control cable of 4 core x 2.5 sq.mm., 1.1 KV grade FRLS PVC insulated flexible multistrand copper conductors with 2 nos. 12 SWG copper earth wire through surface / Ceiling /wall including necessary connection with PVC conduit & accessories as required for indoor, outdoor units & control panel connections (Cable make: Finolex, Polycab, Gloster/PWD approved as per direction of EIC). | 30 | Mtr | 135 ₹4,050 | 255 ₹7,650 | 135 ₹4,050 |
Tender Value
₹5.1 L
EMD Value
₹10,200
Closing Date
4 Sept 2023, 5:00 pmClosed
Managing Director WBEIDC Ltd
Webel Bhavan Salt Lake SEC V EP GP Block KOL 91
Supply installation testing and commissioning of Split type Air Conditioning machines with all accessories at different locations of Webel Bhavan Salt Lake Sector V Kolkata 700091
2023_WEBEL_547465_1
EC/07/WB/Split AC/ 2023-24/M-22
Open Tender
IT WORKS ORG
30 days
Salt Lake SEC V KOL 91
Please refer to the tender documents
5 documents required · 5 mandatory
₹500
₹10,200
21 May 2026
14 Jul 2023
5 Sept 2023
14 Jul 2023
4 Sept 2023
14 Jul 2023
Amount
Supply & delivery of 2.0 TR new split type air conditioning machine along with remote & fitted with rotary compressor, copper coil designed to operate on 230V +/- 5%, 50 Hz, single phase AC supply. At ISI condition the machine is rated for a capacity of 24000 BTU/Hr. Star rating at least 3 (Refrigerant R32/green gas). Make- Mitsubishi/ Blue Star / Carrier/ Hitachi/Daikin.
Supply & delivery of 1.5 TR new split type air conditioning machine along with remote & fitted with rotary compressor, copper coil designed to operate on 230V +/- 5%, 50 Hz, single phase AC supply. At ISI condition the machine is rated for a capacity of 18000 BTU/Hr. Star rating at least 3 (Refrigerant R32/green gas). Make- Mitsubishi/ Blue Star / Carrier/ Hitachi/Daikin.
Installation, testing & commissioning charges for 1.5 / 2.0 TR capacity Split type Air conditioner with standard angle structure for installation of ODU as per instruction of site Engineer. (Including necessary dismantling of old AC machine).
Supply & laying of refrigeration copper pipe (suction & discharge) with thermal insulation along with cable Outdoor to Indoor Unit suitable for 1.5TR / 2TR Split Air Conditioner. Approx. distance between ODU to IDU 30 ft.
Supply & laying hard PVC water pipe for condensate water drain as recommended.
Supply, installation, testing & commissioning of 4TR capacity Cassette Split Unit (R-410A) Air Conditoner, 3-phase, 415 volt +/- 10%, 50 Hz AC supply, Scroll compressor, having cordless Remote with refrigerant pipes etc. Make- Mitsubishi/ Blue Star / Carrier/ Hitachi/Daikin. CAT no. shall be specified along with technical literature. The cost shall be inclusive of modification required for installation of new AC machine along with necessary copper piping, insulation, electrical cabling between IDU & ODU , supply & charging of R-410A or equivalent HFC refrigerant gas, necessary supporting arrangements for both indoor & outdoor unit, painting of supporting structure etc complete. No hidden cost allowed.
Supply, installation & testing of refrigerant piping with Suction line & Liquid line pipe providing OEM recommended hard / soft drawn copper refrigeration pipelines including necessary fittings, support, fixing etc. & brazing arrangement. Providing necessary Ball isolation valves, Expansion valves, Driers etc. are to be installed as required / recommended. Proper leak testing of entire refrigeration pipelines with dry nitrogen. The suction & liquid line shall be insulated with 9 mm thick Sleeveless nitrile rubber insulation. (For 4TR capacity Cassette Split Unit).
Supply, fabrication and installation of MS base frame for outdoor units with applying of single coat red oxide primer & double coat Black Japan paint. (For 4TR capacity Cassette Split Unit).
Supply and laying of 32 mm dia PVC condensate drain pipe from indoor to the nearest drain point complete with elbows, U traps & insulations. (For 4TR capacity Cassette Split Unit).
Supply & installation of control cable of 4 core x 2.5 sq.mm., 1.1 KV grade FRLS PVC insulated flexible multistrand copper conductors with 2 nos. 12 SWG copper earth wire through surface / Ceiling /wall including necessary connection with PVC conduit & accessories as required for indoor, outdoor units & control panel connections (Cable make: Finolex, Polycab, Gloster/PWD approved as per direction of EIC).
Supply & installation of 200mm x 50mm x 1.6mm GI perforated type cable tray (Hot dip galvanised GI 80 micron approx.) using suitable load bearing capacity full threaded bullet fasteners & other necessary accessories/supports/structural items as required.
UNIVERSAL SALES
Lyric International
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf