Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹15.1 L Quoted ₹15.4 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹16.8 L+₹1.4 L (8.92%)Rejected-Finance | ₹16.8 L+₹1.4 L (8.92%) | L2 | Rejected-Finance LOWEST BIDDER |
Tender Value
₹17.6 L
EMD Value
₹35,300
Closing Date
1 Jul 2024, 6:00 pmClosed
GE 871 EWS
GE 871 EWS, c/o 56 APO
COMPREHENSIVE MAINT OF DG SET , AND REPAIR/MAINT OF MISC E/M EQPTS (SOLAR WATER HEATER, UPS, OT LIGHTS, RO PLANT and CENTRAL HEATING SYSTEM) AND REPAIR/REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING,LIGHT FITTING INCLUDING OTHER E/M ALLIED WORKS AGAINS
2024_MES_656204_1
8816/E8
Open Tender
Civil Works
Item Rate
120 days
ALL THE LOCATIONS MENTIONED IN NIT DOCS
AS PER TENDER DOCS
8 documents required · 8 mandatory
₹500
Yes
GE 871 EWS
₹35,300
14 Oct 2024
28 May 2024
3 Jul 2024
28 May 2024
1 Jul 2024
10 Jun 2024
Amount
Servicing of DG Set 82.5 KVA Make - Kirloskar , checking entire system as per manufacturer's catalogue such as checking all parts for serviceability , taking down defective parts such as checking all parts for serviceablity, taking down defective parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lub oil hose flexible pipe, hose turbo etc and replacing the same with same size, make and capacity of parts , cleaning all the serviceable filters with cleaning solution such as petrol and diesel and draining out the old used burnt engine oil from the oil sump and cleaning oil sump with cleaning solution such as petrol and diesel or any other cleaning solution and refilling new engine oil grade 15W/40 upto required level and including testing to DG Set to the entire satisfaction of the Engr-in-Charge. Note : repalcement of items mentioned in the servicing will be measured and paid separately under items Sr No 7.1 to 7.7 (b) Servicing will carried out through authrized service engineer of OEM . Contractor has to submitt the MOU with OEM or authoirzes service centre by OEM to accepting officer before commencement of contract .
Supply only Spinion lub oil filter for DG Set of capacity 200kVA
Supply only Fuel filter element primary for DG Set of capacity 82.5 kVA
Supply only Fuel filter element secondary for DG Set of capacity 82.5 kVA
Supply only Safety air filter element for DG Set of capacity 82.5 kVA
Supply only Primary air filter element for DG Set of capacity 82.5 kVA
Supply only KOEL care premium genuine engine oil 13 Litres cane.
Supply only KOEL care premium genuine coolant premix .
M&L for supply ,fixing and installation in replacement of 63 Amp Controller Based ATS Panel complete all as specified and directed .
M& L for replacement of fuel pipe set for engine of DG Set of capacity 82.5 kVA complete all as specified and directed.
M& L for replacement of radiator hose pipe set for engine of DG Set of capacity 82.5 kVA complete all as specified and directed.
Battery Lead of size 35 Sq mm copper single core flexible wire FR PVC insulated with thimble providing complete all as specified and directed.
S& F in replacement Asbestos rope (heat protectable) of existing size for exhaust hose/fume circulate pipe including taking down existing complete all as specified and directed.
M&L for Servicing of self starter after taking down the same from DG Sets of capacity 82.5kVA , transporting to workshop, opening the same and replacing the defective parts/winding including testing after repair/ servicing and refixing in original position complete all as specified and directed.
Supply and fixing in replacement V belt set ( for fan & alternator) for 82.5 KVA DG set of make Kirloskar/CG/Cummins etc all as per existing complete all as specified and directed
S & F in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 180 AH (battery) complete all as specified and as directed. Make : Exide/ TATA GREEN/AMARON
M & L for replacement of locks for sound proof canopy of any make as per recommendation of OEM
SOLAR WATER HEATER
Repair/maintenance/ Servicing and checking of defects of storage type solar water heater of capacity 100/200/500/1000 litre at different locations by disconnecting inlet/outlet connections , painting of solar water stand and water tank stand with black paint weather proof, repair of foundation, replacement of electric cable as per site requiement testing all as specified and directed.
S&F in replacement of Hot water tank of capacity 100 LPD for solar water heater made out of premium grade stainless steel , inner coating with high grade anit corrosive coating , outer cladding .45mm galvanised ron with PP powder coating all as specified and directed.
S&F in replacement of Hot water tank of capacity 500 LPD for solar water heater made out of premium grade stainless steel , inner coating with high grade anit corrosive coating , outer cladding .45mm galvanised ron with PP powder coating all as specified and directed.
S&F in replacement of Hot water tank of capacity 200 LPD for solar water heater made out of premium grade stainless steel , inner coating with high grade anit corrosive coating , outer cladding .45mm galvanised ron with PP powder includiing connection with hot water pipe for distribution coating all as specified and directed. Make : V Guard / TATA
S&F in replacement of Hot water tank of capacity 1000 LPD for solar water heater made out of premium grade stainless steel , inner coating with high grade anit corrosive coating , outer cladding .45mm galvanised ron with PP powder coating all as specified and directed.
S&F in replacement of solar heating element 3 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
Supply and fixing in replacement collector toghened glass of flat collector box suitable for solar water heater of capacity 200/500/1000 LPD complete all as specified and directed.
Supply and fixing in replacement of hose pipe for flate plate collector of solar water heater of capacity 100/200/500/1000 LPD complete all as specified and directed.
M&L for disconnecting and taking down hot water tank of solar water heater of capacity 100/200/500/1000LPD for descalling and refixing at the same location complete all as specified and directed.
M&L for disconnecting and taking down flate plate collector of solar water heater of capacity 100/200/500/1000LPD for descalling and refixing at the same location complete all as specified and directed.
M&L for disconnecting and fixing in replacement of flange nipple for solar flate collector complete all as specified and directed
Supply and fixing in replacement collector gasket (EPDM) complete all as specified and directed
Supply and fixing in replacement of temperature gauge for hot water tank of solar water heater of any type and capacity complete all as specified and directed.
Supply and fixing in replacement make up tank for solar water heater of capacity 100/200/500/1000LPD including taking down of exiting defecting tank complete all as specified and directed.
M&L for collector gas welding for demaged collector due to freezing and testing after welding complete all as specified and directd.
RO Water plant
Comprehensive maintenance,servicing, repair/ replacement of defective/unsv parts of RO Plant having purity capacity 50 litres per hour. Checking and testing of the RO shall be done for the period of 03 month. Contractor will be responsible for serviceability of each RO during the month complete all as specified and directed. Make : Waves/Aquafresh/Ion Exchange/ Aquaguard Note:- unsv parts shall be measured and paid seperately under the item Sr No 42.1 to 42.11
Supply only following spare parts for RO plant having purity capacity 50 ltrs per hours of Make Wave/Ion Exchange/Aquaguard complete all as specified and shall be replaced under the item No. 1:-
Electric motor single phase 1/4 HP AC, 230 volt
Membrane suitable for 50 ltr RO
Transformer 230 v / 9 v
Solenoid valve
F.R 450 filter
PPF Filter
Sediment filter
C.T.O filter
Membrane housing suitable for RO of capacity 50 ltrs
Hard PVC balls suitable for Paper filter of capacity 50 Ltrs
Ultra Violet Rays chamber with UV lamp and adopter complete suitable for 50 ltrs RO system
PVC pipe for flow of running water , waste water of suitable size as existing complete as specified
Preventive maint of UPS cum voltage regulator 2x20 KVA 415 Volt 50 Hz by the authorised service Engineer of UPS the equipment will be checked / inspected any time for detecting and certified the fault during the 06 month complete all as specified. Note: Rates are deemed to be included in the item rates for the following service,and servicing will be carried out quarterly during the contract period:- (a) Ensure equipment is clean where approriate. (b) Visual inspection of the UPS. (c) Check all re-set, where necessary relevant present adjustment. (d) To rectify any apparent fault, where immediately possible, records other for later rectificatuion. (e) To taking of electrical measurement to established the operation state of the UPS. (f) Check setting of adjustable device.
(g) Visual inspection of UPS batteries. (h) Checking for correct and accurate operation of all instruments. (j) Record total voltage of battery under float condition. (k) Check each battery voltage once during the contract period. (l) Cost of all spare parts included in the item rate quoted except. wound component AC/DC capacitor, Fan and batteries.
(M) Cheacking and installation of Software and hardware program if necessory with proper othorised dealer of UPS company, rate of software and hardware included in above job rate
Preventive maint of UPS cum voltage regulator 4X 10 KVA 415 Volt 50 Hz by the authorised service Engineer of the equipment will be checked / inspected any time for detecting and certified the fault during the 06 month complete all as specified. Note: Rates are deemed to be included in the item rates for the following service, service will be carried out quarterly during the contract period:- (a) Ensure equipment is clean where approriate. (b)Visual inspection of the UPS. (c) Check all re-set, where necessary relevant present adjustment. (d) To rectify any apparent fault, where immediately possible, records other for later rectificatuion. (e) To taking of electrical measurement to established the operation state of the UPS. (f) Check setting of adjustable device. (g) Visual inspection of UPS batteries.
(h) Checking for correct and accurate operation of all instruments. (j) Record total voltage of battery under float condition. (k) Check each battery voltage once during the contract period. (l) Cost of all spare parts included in the item rate quoted except. wound component AC/DC capacitor, Fan and batteries.
(M) Cheacking and installation of Software and hardware program if necessory with proper othorised dealer of UPS company, rate of software and hardware included in above job rate
Supply and fixing in replacement of Communication interface board(CIB board) of 10 KVA UPS and replacing the board of proper make of existing in site with complete connection of existing cables with and CIB board makeing ups running condition complete all as specified and directed. Make : As per existing in site or Approved by engr in charge
Supply and fixing in replacement of Communication interface board(CIB board) of 20 KVA UPS and replacing the board of proper make of existing in site with complete connection of existing cables with and CIB board makeing ups running condition complete all as specified and directed. Make : As per existing in site or Approved by engr in charge
Supply and fixing in replacement of Monitoring unit Board and programing flashing of 20 KVA ups ,Proper coy make existing at site with complete connection through othorised operator of company Make : As per existing in site or Approved by engr in charge
Supply and fixing in replacement of Monitoring unit Board and programing flashing of 10 KVA ups ,Proper coy make existing at site with complete connection through othorised operator of company Make : As per existing in site or Approved by engr in charge
Supply and fixing in replacement charger board of 20 KVA UPS existing in site complete all as specified and directed.Make : liebert or existing in site/approved by Engr in Charge
Supply and fixing in replacement charger board of 10 KVA UPS existing in site complete all as specified and directed.Make : liebert or existing in site/approved by Engr in Charge
Supply and fix in replacement old unserviceable SMF type 12 volt 42 AH of existing make/model conecting each other, with suitable size of copper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and directed. Make : Exide/Amron/Luminious or equivalent.
Internal Electrification Zone
Attending complaints for checking and replaceing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. attending minor repair(s) such as testing, connectins, fittings, nut, bolts, screws etc to emergent complaints i.e no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electical system of main building/block and making continuous electric supply including carrying out minor repairs etc.. required to make the system in order/*functional with insualtion tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints are all inside GE 871 EWS.. Contractor shall provide minimum one tradesmen (electrician) for each site with suitable tool box to attend the complaint in all working days between 0800 hrs to 1900 Hrs including holiday and Sunday.In case of No light The power will be ensured by connecting service wire from nearset LT panel. 2. Contractor shall ensure the security passess for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the electicians with necessary tools bag shall always remain present at complaint cell to attend the Complaints. 4. A recovery of Rs 500/- for not attending the complaint upto 04 hours and after 04 hours Rs 1000/- shall be recovered from the contractor due 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost . 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here in after.
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 1.5 Sqmm. Make-Plaza/Grandlay/Gloster/Polycab
All as per item No 68 above but size 2.5 Sqmm.Make-Plaza/Grandlay/Gloster/Polycab
All as per item No 68 above but size 4 Sqmm.Make-Plaza/Grandlay/Gloster/Polycab
All as per item No 68 above but size 6 Sqmm.Make-Plaza/Grandlay/Gloster/Polycab
M&L in replacement of switch piano flush button single pole one way 5 amps 240 volts .Make-Anchor/Havells/IndoAsian
M&L in replacement of Switch piano flush button single pole one way 15 amps 230 Volts.Make-Anchor/Havells/IndoAsian
M&L in replacement of for socket 5 amps 5 pin flush type, 230 volts. Make-Anchor/Havells/IndoAsian
M&L in replacement of for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts .Make-Anchor/Havells/IndoAsian
M&L in replacement of bell push flush button single pole one way 5 amps 240 volts. Make-Anchor/Havells/IndoAsian
M&L in replacement of for electric bell heavy duty ding dong,buzzer type AC 230 volts single pole complete and all as specified. Make-Anchor/Havells/IndoAsian
M&L in replacement of switch modular type single pole one way 1 module 6 amps 240 volts. Make-Anchor/Havells/IndoAsian
M&L in replacement of Switch modular type one way 1 module 16 amps 230 Volts. Make-Anchor/Havells/IndoAsian
M&L in replacement of for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts as per sample.Make-Anchor/Havells/IndoAsian
M&L in replacement offor socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts. as per sample..
M&L in replacement ceiling rose surface bakelite 3 terminals .Make-Anchor/Havells/IndoAsian
S & F Lamp holder insulated body with back plate for dome batten fittings. Make-Anchor/Havells/IndoAsian
Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts all as directed by Engr-in-Charge. Make-Anchor/Havells/Indoasian
Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts all as directed by Engr-in-Charge. Make-Anchor/Havells/Indoasian
Supply and fix in replacement of LED batten luminaire surface mounted, 4 feet system wattage of 20/22 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures. Make-Bajaj/Havells/Crompton/Wipro
Supply and fix in replacement of LED batten luminaire surface mounted, 1 feet system wattage of 10 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures. Make-Bajaj/Havells/Crompton/Wipro
S&F in replacement of LED tube light fitting, 4 ft, bright 18 watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Havells Cat Pt No LHEXBLP7JN1W018 or equivalent Philips/Bajaj
S&F in replacement of LED light fitting recess mounted 31/32 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making making electrical connection with making electrical connection with three core copper wire to ceiling rose properly all as directed. Make-Bajaj/Havells/Crompton/Wipro
Taking down and refixing of LED tube light fitting bright 18 Watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply and fixing in replacement of 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast Aluminium housing for better heat decapitation.P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.Make-Bajaj/Havells/Crompton/Wipro or equivalent as approved
M&L in replacement earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of Sl part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
M&L for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 25 amps 240 volts, complete with one single pole MCB of 25 amps earthing. Make-Indoasian/Havells/Legrand
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link of make Legrand or equivalent of make Havells/L&T fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .Make-Indoasian/Havells/Legrand or equivalent as approved
All as per srl item No 94 above but for DB SPN 8 way.Make-Indoasian/Havells/Legrand
M&L in replacement of for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size.Make-Indoasian/Havells/Legrand
M&L in replacement of MCB single pole & neutral 240 volts 32 amps,with rupturing capacity 10 KA using thimbles of required size. Make-Indoasian/Havells/Legrand
All as per item No 97 above but of size 63 Amps.Make-Indoasian/Havells/Legrand
M&L in replacement of MCB TPN 240 volts 63 amps,with rupturing capacity 10 KA using thimbles of required size. Make-Indoasian/Havells/Legrand
Supply and fix in replacement of LED Wall Security light 25 Watt IP 66 Energy saving & environmental friendly long life pressure die-cast aluminium housing for better heat decapitation efficiency not less than of 100LM/Wat ,P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as specified. Make-Bajaj/Havells/Crompton/Wipro
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed
S&F in replacement of PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
S&F in replacement of PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply and fix in replacement of stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed.
S&F in replacement of inner tank 9 holes suitable for Geyser 25 liters capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of inner tank 6 holes suitable for Geyser 25 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of inner tank 9 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of inner tank 6 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of Inner tank 9 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of Inner tank 6 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of indication lamp (Green/Red) as per required at site all as specified & directed.
S&F in replacement of thermal Auto cut of range 0-90 degree centigrade (ISI marked) complete all as specified and directed.
S&F in replacement of geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
S&F in replacement of Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
S&F in replacement of Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed
Taking down carefully unserviceable exhaust fans of any size from its position, dismanteling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condensor, rubber shackle will be measured and paid separately
S&F in replacement of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed.Make : SKF/TATA/Universal/polar
S&F in replacement of condenser capacity 4/3.15/2 MFD all as specified and directed. Make : Usha/Universal/ Keltran
M&L For Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
M&L for burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep all as specified and directed.
S&F in replecement of blade suitable for exhaust fan 300/450mm, size as that of existing defective one all as specified and directed. (ISI Marked)
Taking down and dismantling of refrigerator/deep freezer of capacity 160-320 litres of capacity after disconnecting of electric connection for servicing, overhauling and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts all as specified and directed. Note:- Defective parts like capacitor, compressor, condesing coil, fan motor, blower motor, fan blade and gas charging will be measured and paid separately under relevent item of schedule.
Supply and fix in replacement of compressor suitable for 160-320 litres capacity refrigeratror. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG or equivalent as approved
Supply and fix in replacement of capacitor (starting/running) suitable for 160-320 litres capacity refrigerator (ISI Marked) all as specified and directed.
Supply and fix in replacement of condesing coil assesmbly suitable for 160-320 litres capacity refrigerator all as specified and directed. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
M&L GAS charging (R-24/134A) suitable for 160-320 litres capacity refrigerator all as specified and directed.
Supply and fix in replacement of PVC/Iron fan blade suitable for 160-320 litres capacity of refrigerator. (ISI Marked) all as specified and directed.
Supply and fix in replacement of fan motor/blower motor suitable for 160-320 litres capacity of refrigerator all as specified and directed.Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG or equivalent as approved
S & F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal with complete box all as specifid and directed..Make-Anchor/Havells/IndoAsian
S & F switch socket combination 2 in 1, 3 pin,15 Amp flush type universal with complete box all as specifid and directed..Make-Anchor/Havells/IndoAsian
S & F Switch socket combination 2in 1, 5 A flush types all as specifid and directed..Make-Anchor/Havells/IndoAsian
S & F Switch socket combination 2 in 1, 15 A flush types all as specifid and directed..Make-Anchor/Havells/IndoAsian
Supply and fixing in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings Make : Anchor/Legrand/HPL/Cona
Supply and fixing in replacement 5 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Havells/philips/Bajaj/CG
S & F of led Bulb of 09 Watt cool day light eco friendly energy efficient all as specified and directed by Engr In Charge.Make-Bajaj/Wipro/Havells
Supply and fix PVC conduit 20 mm dia suitable for 1100 volt , 230/240V AC supply all as specified and as directed. Make : Plaza/Kalinga/Polypac/kaliga
Supply and fix PVC casing caping 20x12 mm suitable for 1100 volt , 230/240V AC supply all as specified and as directed. Make : Plaza/Kalinga/Polypac/kaliga
Supply and fix PVC board (ISI Marked) with back plate 04 Module with screws and rawal plug
Supply and fix PVC board (ISI Marked) with back plate 06 Module with screws and rawal plug
M&L in replacement of sub main wiring in PVC conduit of required size 2 x 4 sqmm PVC insulated multistrand copper conductor FRLS with 01x4 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Make : Havells/Plaza/ Polycab.Note:- For the purpose of payment two runs of 4sqmm conductors and one run of 4 sqmm conductor with conduit will be measured as one length.
Amit Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .