Assistant Engineer Elect
AE(E) HC1 HMED(C) PWD LN Hospital New Delhi
Conversion of Room No. D-125 as COVID-19 Laboratory (PCR Lab) at D Block, GIPMER, New Delhi
2020_PWD_193249_1
NIQ 1(21)/AEE/HC1/PWD/HMEDC 2020-21/237
Open Tender
Miscellaneous Works
Works
10 days
Work
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹5,000
Yes
13 Aug 2020
4 Aug 2020
10 Aug 2020
4 Aug 2020
10 Aug 2020
4 Aug 2020
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (a) Group C
Supplying and fixing of PVC trunking with partition/ cover/ joint/ clips/ end caps/ angles etc. as required for drawing wires and erection of flexible outlets/ switches of various types. (a) 105mm x 50mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 6 sq. mm
b) 3 x 4 sq. mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 3 Module (100mmX75mm)
b) 6 Module (200 mmX75 mm)
c) 12 Module (200mmX150mm)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch
b) 15/16 A switch
c) 3 pin 5/6 A socket outlet
d) 6 pin 15/16 A socket outlet
Supplying, installation, testing & commissioning of energy efficient surface mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) fabricated with MS powder coated white CRCA housing and connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required including dismantling alongwith credit for worn out luminaries under buy back arrangement. The Total system Lumen of 34W to 38W LED should be minimum 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.90, CRI (Ra)>75, THD <10% , with APFC driver having driver efficiency >85 % , operating voltage 150-270 volts with minimum 2.5KV şurge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours@ L-70 and LED photo biological safety report conforming to IEC 62471 & LED Source manufacturer and LM- 79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Lumiled, Osram, Seoul etc complete as reqd..(Make Crompton/ Wipro/ Havells/ Phillips/ Trilux / Halonix)
Supply, installation, testing & Commissioning of Split Air Conditioning unit of 1.5 TR capacity i.e. with cooling capacity not less than 5250 Watt non inverter complete with outdoor condensing unit & wall mounted evaporating unit having cordless remote control refrigerant pipe line upto 4 meter length, capable of cooling, filtering & dehumidifying, suitable for operation on 230 volt1=Ph. AC supply (Not less than three star rating model as certified by BEE) with mountings,/ fittings for indoor/ outdoor units, insulating the suction pipe with EPF tubing, leak test, charging refrigerant including providing electrical wires with in 4 meter of location of unit complete as reqd at site work. (Make :- O-General/ Hitachi/ Carrier)
Supply installation of copper refrigerant pipe (3/8' & 5/8') in split AC Unit incl insulation, drain pipes and covered with fixable pipe i/c 3 core 2.5sq.mm.copper conductor wire complete etc as reqd.
M/S HIMANSHU ELECTRICAL
Om Shanti Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .