| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-Finance | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹28.6 L+₹1.8 L (6.85%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹31.8 L+₹5.0 L (18.5%)Rejected-Finance GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹32.5 L+₹5.7 L (21.2%)Rejected-Finance 32 LOOTERY MOHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-Finance Higher bid value |
| Sl No | Description | Qty | Unit | REMCO L1 | SANKAR TRADERS L2 | JADAV CONSTRUCTION L3 | Das and Brothers L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking out split type air conditioners indoor and out door units complete for repair and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay assembly, relay contactor, capacitors, thermostat, fan motor with blades & blower fan motor with blades, unserviceable strainer air filters cum dryier etc after taking down of old materials as required and also including connecting of refrigerant pipe, drain pipe and also charging of refrigerant gas and fixing back in its original location after satisfying testing complete all as specified and directed.
(Note :- (i) Spare parts will be measured and paid separately as "Supply only".
(ii) Refrigerant gas will be measured and paid separately as "Supply only".
(iii) Lobour charge for taking down and fixing of " Supply only" materials are
deemed to be included with quoted rate.) | 22 | Each Job | 1,400 ₹30,800 Lowest | 1,505 ₹33,110 | 1,674 ₹36,828 | 1,705 ₹37,510 |
| 2.00 | Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting ,soldering ,flaring work with nut ,jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split AC upto 1.5/2TR capacity and testing complete all as specified and directed.(Note Refrigerant will be paid separately.) | 12 | Each job | 1,300 ₹15,600 | 1,246 ₹14,952 Lowest | 1,385 ₹16,620 | 1,411 ₹16,932 |
| 3.00 | Supply only for starting capacitor of upto 80- 100 MFD for split type air conditioners upto 2 TR capacity complete all as specified and directed. | 12 | Each | 379 ₹4,548 Lowest | 383 ₹4,596 | 426 ₹5,112 | 434 ₹5,208 |
| 4.00 | Supply only for running capacitor of upto 30-60 MFD for split type air conditioners complete all as specified and directed. | 10 | Each | 423 ₹4,230 Lowest | 424 ₹4,240 | 472 ₹4,720 | 481 ₹4,810 |
| 5.00 | Supply only fan motor with blade suitable for out door unit split type air conditioner up to 2 TR capacity (as per sample) complete all as specified and directed. | 10 | Each | 2,170 ₹21,700 Lowest | 2,204 ₹22,040 | 2,451 ₹24,510 | 2,496 ₹24,960 |
| 6.00 | Supply only blower fan motor with blade for out door unit including capacitor, single phase, 230V, 50Hz, ISI Marked for split type air conditioner upto 2 TR capacity (as per sample) complete all as specified and directed. | 6 | Each | 2,170 ₹13,020 Lowest | 2,710 ₹16,260 | 3,014 ₹18,084 | 3,069 ₹18,414 |
| 7.00 | Repair to Blower Fan motor suitable for split AC upto 2 TR capacity as per sample complete all as specified and directed. | 5 | Each | 1,490 ₹7,450 Lowest | 1,505 ₹7,525 | 1,674 ₹8,370 | 1,705 ₹8,525 |
| 8.00 | Supply only relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity (as per sample) complete all as specified and directed. | 8 | Each | 366 ₹2,928 Lowest | 369 ₹2,952 | 411 ₹3,288 | 418 ₹3,344 |
| 9.00 | Repair to Relay assembly suitable for split AC upto 2 TR capacity as per sample complete all as specified and directed. | 5 | Each | 1,490 ₹7,450 Lowest | 1,505 ₹7,525 | 1,674 ₹8,370 | 1,705 ₹8,525 |
| 10.00 | Supply and topping up of refrigerant gas (R-22 ) suitable for split/window AC complete all as specified and directed. | 25 | KG | 1,200 ₹30,000 Lowest | 1,232 ₹30,800 | 1,370 ₹34,250 | 1,395 ₹34,875 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BARRACKPORE
Office of the GE BARRACKPORE, KOLKATA - 700120
REPAIR/MAINTENANACE REFRIGERATOR , ACS, WATER COOLER, DEEP FRIGERS ETC AT MIL STN KANCHRAPARA UNDER GE BARRACKPORE
2026_MES_786267_1
8240/E8
Open Tender
Civil Works
Item Rate
270 days
BARRACKPORE
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹500
GE BARRACKPORE
₹50,000
Yes
7 Nov 2026
25 Aug 2026
24 Sept 2026
25 Aug 2026
22 Sept 2026
8 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out split type air conditioners indoor and out door units complete for repair and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay assembly, relay contactor, capacitors, thermostat, fan motor with blades & blower fan motor with blades, unserviceable strainer air filters cum dryier etc after taking down of old materials as required and also including connecting of refrigerant pipe, drain pipe and also charging of refrigerant gas and fixing back in its original location after satisfying testing complete all as specified and directed.
(Note :- (i) Spare parts will be measured and paid separately as "Supply only".
(ii) Refrigerant gas will be measured and paid separately as "Supply only".
(iii) Lobour charge for taking down and fixing of " Supply only" materials are
deemed to be included with quoted rate.) | 22 | Each Job | - | - |
| 2 | Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting ,soldering ,flaring work with nut ,jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split AC upto 1.5/2TR capacity and testing complete all as specified and directed.(Note Refrigerant will be paid separately.) | 12 | Each job | - | - |
| 3 | Supply only for starting capacitor of upto 80- 100 MFD for split type air conditioners upto 2 TR capacity complete all as specified and directed. | 12 | Each | - | - |
| 4 | Supply only for running capacitor of upto 30-60 MFD for split type air conditioners complete all as specified and directed. | 10 | Each | - | - |
| 5 | Supply only fan motor with blade suitable for out door unit split type air conditioner up to 2 TR capacity (as per sample) complete all as specified and directed. | 10 | Each | - | - |
| 6 | Supply only blower fan motor with blade for out door unit including capacitor, single phase, 230V, 50Hz, ISI Marked for split type air conditioner upto 2 TR capacity (as per sample) complete all as specified and directed. | 6 | Each | - | - |
| 7 | Repair to Blower Fan motor suitable for split AC upto 2 TR capacity as per sample complete all as specified and directed. | 5 | Each | - | - |
| 8 | Supply only relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity (as per sample) complete all as specified and directed. | 8 | Each | - | - |
| 9 | Repair to Relay assembly suitable for split AC upto 2 TR capacity as per sample complete all as specified and directed. | 5 | Each | - | - |
| 10 | Supply and topping up of refrigerant gas (R-22 ) suitable for split/window AC complete all as specified and directed. | 25 | KG | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_881079.xls
BOQ • 0.63 MB
Tenderdoc_8240.pdf
Tender Documents • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .