Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.5 LAccepted-AOC 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹94.8 L+₹28.3 L (42.6%)Rejected-Finance | L2 | Rejected-Finance Being not lowest bidder | |
| 3 | L3₹1.2 Cr+₹56.5 L (85.0%)Rejected-Finance CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | L3 | Rejected-Finance Being not lowest bidder |
Tender Value
₹70.2 L
EMD Value
₹1.3 L
Closing Date
10 Jan 2022, 6:00 pmClosed
Commander Works Engineer NB Kochi
Kataribagh Naval Base PO Kochi 682 004
81044PROVN OF 10000 LTR CAPACITY RCC WATER TANK AT 7.5 RM STAGING FOR FIRE FIGHTING AT NAQAS, KOCHI
2021_MES_492864_1
81044/RCC Water tank/E8
Open Tender
Civil Works
Lump-sum
270 days
Naval Base
Class C and above
Category a i
8 documents required · 8 mandatory
₹1,000
GE P NW Kochi
₹1.3 L
Yes
9 Feb 2022
6 Dec 2021
12 Jan 2022
6 Dec 2021
10 Jan 2022
27 Dec 2021
7 Dec 2021 - 21 Dec 2021
Amount
List of Works
Total amount of Sch 'A' part-I (Buildings/ Structures)
Total amount of Sch 'A' part-II (iInternal Electric supply)
Total amount of Sch 'A' part-III (Fire fighting & Fire alarm system)
Total amount of Sch 'A' part-IV (Structural Glazing)
Total amount of Sch 'A' part-V (External Electric Supply)
Sch 'A' Part- VI (Miscellaneous) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
TESTING OF PILES : Testing of pile (Initial load test) all as per IS for cast in situ 500mm dia under reamed piles including mobilising and removing the testing equipment from site after testing complete all as specified and as directed
Testing of pile (Routine load test) all as per IS for cast in situ 500mm dia under reamed piles including mobilising and removing the testing equipment from site after testing complete all as specified and as directed
INTERNAL ELECTRIC SUPPLY : Supply and fix flame proof rotary switch with termination box in LM 6, 16 A complete all as specified and as directed
Supply and fix flame proof switch socket and plug combined with termination box in LM 6, 16 A complete all as specified and as directed.
Supply and fix flame proof switch socket and plug combined with termination box in LM 6, 25 A complete all as specified and as directed.
Supply and fix flame proof LED light fitting 20 W complete all as specified and as directed.
Supply and fix flame proof Wall mounted fan 415 mm complete all as specified and as directed.
Supply and fix flame proof Exhaust fan 305 mm complete all as specified and directed
Supply and fix MCB SP 16 Amp 240 volts
Supply and fix MCB SP 6 - 10 Amp 240 volts
Supply and fix MCB SP 32 Amp 240 volts
Supply and fix MCCB 4 pole 40 Amp 240 volts
Supply and fix VTPN DB 8 Way with MCCB incomer
Supply and fix UPS three phase AC input 300 to 450V and out put 400 V ± 1% of capacity 20 KVA, IGBT Technology, Pure sine wave, LCD Display , Crest factor 3 : 1 with inbuilt galvanic isolation transformer, ISO certified with battery for 30 min backup Technical specification of battery: SMF (Sealed Maintenance free battery) mith metal battery stand , 65 AH X 20 no's battery for 30 min backup complete all as specified and directed.
FIRE FIGHTING & FIRE ALARM SYSTEM : Supply and fix DI pipe both ends flanged, class K-9 type nominal dia 150 mm with DI fittings as per IS 8329-2000 & IS 9523-2000 complete all as specified and directed.
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia complete all as specified and directed.
Supply, install, testing and commissioning LT Motor control panel outdoor type with front operated single door floor mounting type made out of 2mm thick CRCA sheet powder coated, dust proof manufactured complete with 200 Amps TPN aluminium bus bar with the following components : (a) Incoming MCB 40 A 4 pole (b) Outgoing MCB 20 A 3 pole (c) SPN MCB 16 Amps - 3 Nos (d) Star Delta Starter 415 V, AC upto 10 HP - 2 Nos (e) Digital Voltmeter with SS 0-500 V - 01 Nos (f) Digital Ammeter Ss 0-50 A - 01 No (g) Phase indication lamp R,Y,B - 01 Set (h) Single phase preventor - 02 Nos
Supply, installation, testing and commissioning of Addressable type Active Loop Repeater Panel (Loop power/external power) Fire terminal, Backlit LCD Display 6x40 characters display, having Controls for Reset, Mute, Accept, Silence alarms and Self Test with programmable free Keys and Duly approved by UL/FM (repeater panel should be placed in Guruda Fire Station) complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY :Supplyand fix FRLS armoured copper cable 2 Core 1.5 Sq.mm ISI marked with proper clamping, supports and terminations complete all as specified and directed by Engineer-in-charge.
M/S SABU PETER
Classic Builders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .