Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 CrAccepted-AOC | ₹23.8 Cr Quoted ₹24.1 Cr | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹24.1 CrRejected-Finance | ₹24.1 Cr | L2 | Rejected-Finance Rejected due to L2 |
| 3 | L3₹24.8 CrRejected-Finance | ₹24.8 Cr | L3 | Rejected-Finance Rejected due to L3 |
| 4 | L4₹25.2 CrRejected-Finance | ₹25.2 Cr | L4 | Rejected-Finance Rejected due to L4 |
| 5 | L5₹25.3 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹25.3 Cr | L5 | Rejected-Finance Rejected due to L5 |
Tender Value
₹21.2 Cr
EMD Value
₹13.9 L
Closing Date
12 Oct 2023, 6:00 pmClosed
HQ CE Jodhpur Zone
HQ CE Jodhpur Zone
PROVN OF OTM ACCN (PHASE I OF TWO PHASES) AT AHMEDABAD CANTT (JOB NO S/2978)
2022_MES_558754_4
800564/AMD/2022-23/E8
Open Tender
Civil Works
760 days
Ahmedabad
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
Yes
GE (A) Ahmedabad
₹13.9 L
Yes
1 Mar 2024
14 Sept 2023
14 Oct 2023
14 Sept 2023
12 Oct 2023
28 Sept 2023
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 28
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 30
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 31
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 35
Lump sum price worked out by the contractor for "ROAD, PATH AND CULVERT" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 38
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 40
Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No. 41
Lump sum price worked out by the contractor for "COMPOUND WALL, FENCING AND GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 44
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 45
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 47
Lump sum price worked out by the contractor for "DEMOLITION B/R & E/M" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 48
Lump sum price worked out by the contractor for "HOT AND COOLING APPLIANCES" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 49
Lump sum price worked out by the contractor for "LIGHTING PROTECTION" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 50
Lump sum price worked out by the contractor for "ARBORICULTURE" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 51 (R)
Sch 'A' PART-XV (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
INTERNAL WATER SUPPLY S&F 15 mm bore, fancy type, CP brass bib cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make - Jaquar ESSCO series or technocommercial equivalent of any make specified in Appx 'C'.
S&F 15 mm bore, fancy type, CP brass angular stop cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make - Jaquar ESSCO series or technocommercial equivalent of any make specified in Appx 'C'.
S&F overhead shower 80 mm dia of ABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and directed. Make - Jaquar ESSCO series or technocommercial equivalent of any make specified in Appx 'C'.
S&F health foucet with 1200 mm long flexible mild steel tube 20 mm dia with wall hook complete all as specified and directed. Make - Jaquar ESSCO series or technocommercial equivalent of any make specified in Appx 'C'.
S&F two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed. Make - Jaquar ESSCO series or technocommercial equivalent of any make specified in Appx 'C'.
INTERNAL ELECTRIFICATION S & F modular type 25/32 A SP MCB, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed.
S & F modular type 3 pin 25/32 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.
S&F vertical triple pole & neutral double door DB 4 way, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
S&F 20 W surface / wall mounted decorative type LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy of > 120 lumen/W, CRI ≥ 75, PF > 0.9, CCT 6500K, free of glare independent isolated SMPS based constant current electronic LED driver with THD < 15%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 120- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S&F 10 W 3-star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of > 120 lm/W, starting time < 0.5 s, CRI ≥ 75, CCT 6500K, PF >0.9, input voltage range 120- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed.
S&F 10 W surface / wall mounted decorative type LED batten capable of delivering 1000 lumen, having PC diffuser, luminous efficacy of > 120 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, free of glare independent isolated SMPS based constant current electronic LED driver with THD < 15%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 120- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S&F 12 W surface mounted round shape LED downlight, aluminium housing and high translucent frosted plastic diffuser, capable of delivering 1200 lumen. having minimum luminous efficiency > 120 lumen/W, CCT 3500K, CRI ≥ 75, high quality polycarbonate diffuser, input voltage range 120- 270 V, input frequency 50- 60 Hz, including electrical connection complete all as specified and directed.
S&F 25 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 120 lumen/W, integral SMPS based constant current electronic LED driver with THD < 15%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high efficacy polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete in all respect as specified and directed.
ROAD, PATH AND CULVERT M&L for 150 mm thick WMM (Wet Mix Macadam) (compacted thickness) laid in two layers of 75mm thick each conforming to grading given in table 400-13 & physical requirement given in table 400-12 spread by mechanical means & rolled by using 8-10 ton vibrator power roller over compacted sub grade surface of soling as specified in clause 406 3.5 of MORTH specification and necessary lateral support and formwork if required complete all as specified and directed.
M&L for preparing bituminous surfaces of road and marking 2.5 mm thick centre lines, stop lines, dashes, arrows tec. and the like n. exc. 15 cm wide on roads pavements with hot applied thermoplastic road marking paint of approved colour confirming to BS 3262-1989 with 20% glass beds (intermixed) spread and laid by automatic mechanical machine engine at approximate temprature 160 dfegree celcius with special applicator machine as per manufacturers instruction complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply , laying, jointing & testing of Ductile Iron (DI) Type K-7 pipe with socket & spigot ends, with cement morter zinc coated as per IS 8329/2000 in standard length, suitable for and including push on tyton joints with rubber rings, laid in trenches all as specified & directed for following size:- (Note:- Excavation and earth work, CI/DI specials will be measured and paid seperately.)
200 mm dia
150 mm dia
100 mm dia
S&F Cast Iron Non Rising Sluice Valve, Flanged End of class 1.0 PN, As Per IS: 14846, Body,Dome,Wedge- CI , Bronze Spindle, Greasy Jute gland Packing, Fasteners- CS IS:1367, CL-4.6/4.0 Natural Rubber Gasket, Flange drilling as per IS:1538, Table 4 & 6 all as specified and directed for following sizes:-
200 mm dia
150 mm dia
100 mm dia
80 mm dia
M&L for DI fittings such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end tapering bellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tatering as bell mouth or flanged ) caps blank flanges heavy duty suitable for mechanical joint/flanged joint all as specified & directed. Note: Certifiacte for Weight of fitting by the manufacturere shall be submitted before payment.
S&F Cast Iron Foot Valve 100 mm (4") dia, Flanged End IS 4038 PN 0.2, Housing – Cast Iron is 210 Gr FG200 , Strainer – Cast Iron IS 210 Gr FG 200, Door – Cast Iron IS 210 Gr FG 200, Door Plate – Cast Iron IS 210 FG 200, Door Face Natural Rubber , Hinge Pin (for 200mm to 450 mm ) SS 410, fastners – CS IS:1367, CL-4.6/4.0 Flange Drilling IS:1538 Table 4 & 6, complete all as specified and directed.
M&L for CI non return valve 100mm dia without by pass arrangement confirming to IS-5312 part-I, PN 1.0 including nuts, bolts, washers and gaskets complete all as specified and directed.
Supply and install, test commissioning of centrifugal mono block pump set capable of discharging water at 545 LPM at 30 MTR head, 2900 RPM, suction and delivery size as 100x100mm, bronze impeller, directily coupled with suitable induction motor 3 phase 415 Volt, 50 cycle, mounted on MS channel comon base frame and fixed with suitable bolt grouted in PCC foundation (1:2:4) type B-1 (using 20mm graded stone aggregate) 30cm above floor level including PVC insulated unshthad copper cable of suitable size 3 core multistranded in PVC counduit for connection from starter to motor with proper lugs thimbels etc including all necessary accessories like pressure gauges etc complete and foot valve etc complete all as specified and directed.
M&L for construction of brick masonarry new valve pit chamber, 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed of following sizes:-
1200mmx1200mmx1000mm (internal size )
600mmx600mmx600mm (internal size )
Supply, install testing and commissioning of weather and vermin proof L.T. feeder piller box (Panel board) factory fabricated indoor cubicle/kiosk type totally enclosed made out of 2.0 mm thick CRCA sheet metal enclosure of as per IS-8623 of suitable size with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/ wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, powder coated of approved colour, including connection with LT armoured incomming and outgoing cables and including required sizes of cable lugs of aluminium complete all as specified and directed and consisting of following :-
(a) Bus bars of copper strips of 200 Amps current rating capacity, minimum 600mm long or of length as actually required at site for 3 phase and half size for netural mounted on epoxy/FRP busbar insulator-1 set (b) MCCB TP &N 4 pole type, 16 KA (ICS=100% ICU CE approved) thermo magnet release, current rating 100 Amps - 01 No (incoming). (c) MPCB (Motor Protection Circuit Breaker) 32Amps, 415V, 50Hz, 3 pole type, thermal release range 24-32Amps, 50KA (ICS=100% ICU CE approved) thermo magnet release, with over load and short circuit protection as per IS-13947-2 - 02 No (outgoing) (d) MCB SPN 240V 32 A 10 KA (01 outgoing) (e) Indicator lamps (RYB) one set of 3 neon lamps (f) Motor ON indicating lamp (Green), Motor trip indicating lamp (Yellow)
EXTERNAL ELECTRIFICATIONS Supplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 160 KVA capacity transformer, step down, outdoor type, 11000/433 volts (at no load) with system voltage 12KV all as per IS 1180 (Part 1):2014, copper wound, oil immersed, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from (+) 5% to (-) 10% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and confirming to BEE 5 Star Rating (Level 3 transfomer) as per IS 1180 (Part 1):2014
(a) The core shall be stack/wound type of high grade Cold Rolled Grain Oriented or Amorphous Core annealed steel lamination having low loss and good grain properties, coated with hot oil proof Inter layer insulation of Nomex /Epoxy dotted Kraft Paper, bolted together and to the frames firmly to prevent vibration or noise. The core shall be stress relieved by annealing under inert atmosphere if required.The complete design of core must ensure permanency of the core loss with continuous working of the transformers. LV winding shall be such that neutral formation will be at top. Current density for HV and LV winding should not be more than 2.8 Ampere per sq mm (b)The maximum allowable losses at 75 °C for 11/0.433 kV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 416 watts and 1281 watts respectively without any positive tolerance all as per specified in IS 1180 (Part-1):2014 for energy efficient rating 5star. (c) Overload capacity of transformers shall be suitable for loading as per IS 6600 (d) The percentage impedance of transformers at 75 °C for 160 kVA shall be as per Table 6 of IS 1180 (Part-1) : 2014
(e) Transformer tank construction shall conform in all respect to clause 15 of IS 1180(Part-1):2014. The internal clearance of tank shall be such, that it shall facilitate easy lifting of core with coils from the tank without dismantling LV bushings. All joints of tank and fittings shall be oil tight and no bulging should occur during service. Inside of tank shall be painted with varnish/hot oil resistant paint. The top cover of the tank shall be slightly sloping to drain rain water. The tank plate and the lifting lugs shall be of such strength that the complete transformer filled with oil may be lifted by means of lifting shackle. Manufacturer should carry out all welding operations as per the relevant ASME standards. The transformer tank shall be of robust construction and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for the bottom and top and not less than 4 mm for the sides for distribution transformers with Tolerances as per IS-1852.The space above oil level in the tank shall be filled with dry air or nitrogen conforming to commercial grade of IS 1747. The tank shall further be capable of withstanding a pressure of 0.8kg/sq.cm and a vacuum of 0.7 kg/sq.cm (g) without any deformation. (f) Audible sound levels for 160KVA, 50Hz liquid immersed distribution transformers shall be 56 decibels (NEMA Standards) (g) One cable box on primary H.V side having cable glands suitable for 95 Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass/ gun metal bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers. HT Cable box should prevent the ingress of moisture into the box due to rain water directly falling on the box. The cable box on HT side shall be of the split type with faces plain and machined and fitted with Neo-k-Tex or similar quality gasket and complete with brass wiping gland to be mounted on separate split type gland plate with nut-bolt arrangement and MS earthing clamp. The bushings of the cable box shall be fitted with nuts and stem to take the cable cores without bending them. The stem shall be of copper with copper nuts. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight.
(h) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GM bushing rods complete with GM nuts, and washers with cable gland suitable for reception of outgoing L.T. PVC sheathed armoured cables of size 2 x 300 sqmm 3.5 core . having non-magnetic material gland plate with appropriate sized single compression brass glands on LV side to terminate 1.1 kV/single core XLPE armoured cable. (j) The bushing rods and nuts shall be made of brass material 12 mm diameter for both HT and LT bushings. The bushings shall be fixed to the transformers on side with straight pockets and in the same plane or the top cover . The tests as per latest IS 2099 and IS 7421 shall be conducted on the transformer bushings. (k) OIL CONSERVATOR: The provision of conservator is mandatory with oil gauge, air release plug and breathing device with a drain plug and a filling hole 32 mm (1¼”) normal size thread with cover. The dehydrating agent shall be silica gel. The moisture absorption shall be indicated by a change in the colour of the silica gel crystals which should be easily visible from a distance. Volume of breather shall be suitable for1Kg of silica gel conforming to IS 3401. The total volume of conservator shall be such as to contain 10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator. (l) The radiators can be tube type or fin type or pressed steel type to achieve the desired cooling to limit the specified temperature rise. (m) Transformer to be painted with poly urethene/powder caoted (color light gray & DA gray) paints over anti corrosive primer & shall be free from runs, sags, wrinkles, patchiness, brush marks or other defects. All primers shall be well marked into the surface, particularly in areas where painting is evident and the first priming coat shall be applied as soon as possible after cleaning. The paint shall be applied by airless spray.
(n) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device (o) Rating plate with terninal markings. (p) Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6 m GI earth strip. (q) Lifting lugs. (r) Four plane solid cast steel detachable rollers. (s) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103. (t) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral. (u) Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones in signal red colour , one at H.T side and other on L.T side. (v) Any other fittings / accessories so as to conform the whole transformer to IS 1180 (Part 1): 2014
(w) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I): (i) Location : Ahmedabad (ii) Maximum ambient air temperature (°C) : 50 °C (iii) Minimum ambient air temperature (°C) : 5 °C (iv) Maximum average daily ambient air temperature (°C) : 42 °C (v) Maximum yearly weighted average ambient temperature (°C) : 32 °C The temperature rise over ambient shall not exceed the limits given below: (i) Top oil temperature rise measured by thermometer : 35 °C (ii) Winding temperature rise measured by resistance method : 40 °C
Construction of PCC block masonry platform in cement mortar 1:4 of size 2400 x 1800 x1200 mm for outdoor type transformer having sides finished with masonry work with plaster complete with PCC foundation of 1:5:10 & PCC platform at top with 30 cm thick of PCC 1:4:8 and 10 cm thick of PCC 1:2:4 and having brick steps at one side, complete with XPM jali duly welded with angle iron of size 50 mm x 50 mm x 6 mm all around upto 0.6 metre, including excavation and earth work in any type soil , returning filling in and removal of surplus soil upto 50 metre complete all as shown on drawing complete all as specified and directed.
Supply, install, testing and commissioning of HT 11 kV, 3 Phase, 50Hz, totally enclosed metal clad SF6 type VCB having rupturing capacity upto 250MVA, RMU STC 21 kA for 1 sec, IAC 21 kA for 1 sec, copper bus bar type, 2 ways motor operated, outdoor, non extensible, RL comprising of 01 LBS & 2 VCBs in single unit (LBS&VCB to be motorised), rated power frequency voltage 28 kV, rated impulse withstand voltage 75 kV, rated current for ring main feeder - 400A, rated current for VCB 400A, short time current (ik) - 21KA for 3 Sec, rated short making current - 50kA, ambient temperature (-5deg to +55 deg celsius), design ambient temperature (40 degree celsius) with IP 54
Each Load Break Switch includes : (i) SF6 three position switches with position ON-OFF, (ii) Manual/motorised operated spring mechanism ON-OFF-EARTH (iii) Mechanical indicators for position ON-OFF-EARTH (iv) Mimic diagram at the front facia of RMU. (v) Socket for voltage presence indication system shall be provided with voltage detection system to check whether cable is live or dead. (vi) Fault passage indicator. (vii) Padlocking facility.
S&F Polystyrene body IP 65 cable junction box with duly fitted with connector metric knockouts on all sides for cable entry including cable glands,sizeof junction box 200 x 160 x 98 mm,Clamp made of 30x5 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer suitable for steel tubular swaged pole type 410 SP-3.
S&F PVC insulated & sheathed, multistranded copper conductor industrial cable 1.5 sqmm 3 core 1100 volt grade from Junction box to street light fitting as required.
S&F Street light bracket made up of GI tube light grade of 50mm dia not less than 1.2m, bent to shape including supports clamps made up of MS flat of size 25 x 4mm and nut, bolts, washers, welding, bending, drilling holes for bolts of any size and shape and one coat of synthectic enameled paint over a coat of red oxide primer all as specified and directed
S&F automatic street light control switch for switching ON/OFF street lights based on Lux level of ambient light and comprising of Nature switch for lighting load 8KW equally distributed over 3Phase, power contactor of size 25Amps-03Nos, Single phase, MCB SP 25Amps-03Nos, and support terminals enclosed in pole mountable weather proof junction box of IP 54 protection class.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to and including earth lead of galvanized strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I with connected to earth test point & to main switch board with & including adequate quantity of charcoal and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe fpr suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mess including necessary earth work and PCC (1:3:6) type C1 for earth pit and 40mm thick precast RCC cover in cement concrete 1:2:4 type B1, with 3 Nos 8mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified and directed NOTE: Item includes the cost of earth lead and GI protection pipe up to 7.5 m. GI strip and protection pipe beyond 7.5 m shall be measured and paid for separately.
M&L for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to and including earth lead of galvanized strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I with connected to earth test point & to main switch board with & including adequate quantity of charcoal and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe fpr suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mess including necessary earth work and PCC (1:3:6) type C1 for earth pit and 40mm thick precast RCC cover in cement concrete 1:2:4 type B1, with 3 Nos 8mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified and directed NOTE: Item includes the cost of earth lead and GI protection pipe up to 7.5 m. GI strip and protection pipe beyond 7.5 m shall be measured and paid for separately.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Supply, install, testing and commissioning of feeder pillar box CPRI approved outdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 500 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following :- (Main LT Panel)
Supply, install, testing and commissioning of feeder pillar box CPRI approved outdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 250 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following (For FPB-1)
Supply, install, testing and commissioning of feeder pillar box CPRI approved outdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 250 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following:- (For FPB-2)
Supply, install, testing and commissioning of feeder pillar box CPRI approved outdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 200 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following :- (For FPB-3)
Supply, install, testing and commissioning of Bus Bar Panel CPRI approved outdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based Supply, install, testing and commissioning of Bus Bar Panel CPRI approved outdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 250 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following :- (For Bus Bar Panel)
Supplying, installation, connecting electrically, commissioning and testing of Outdoor type free standing type (IP -42) automatic power factor correction system with both auto and manual options type Inlet Var APFC Panel with MD - XL capacitors and MCCB as incomer factory made Non compartmentalised single unit 440 Volts 50 Hz , 3 phase 40 KVAR (Multiple of 5 KVAR) Complete all as specified and as directed including the following :-
(a) Double Metallized paper with polypropylene film cylinderical, type MD-XL capacitor bank of rated voltage 525 volts with detuned Reactor of de - tuning factor (P) 7% and suitable output of 40 KVAr at 440 Volts with ratio Outgoing steps (5 kvar + 5 Kvar + 10 Kvar + 20 Kvar) confirming to IS -13340, 13341, & IEC - 60831 - 1 +2. (b) Capacitor duly contactor with Damping Resistors appropriate rating for capacitor switching confirming to IEC - 60070 & IS 13947. (c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors suitable to display of voltage , current, active power, Reactive power, Apparent power, Display of power factor, THD Voltage, THD current, alarm indication for defective steps, low power factor and excess temperature. The relay has volt free c/o contact, Automatic detection and usage of optimum capacitors. (i) Capable of 4 - Quadrant operation, and any phase offset requirement. (ii) Swithching programms : LIFO, Combi - filter, manual mode. (iii) Build in under and over voltage release with auto reset. (iv) Large Voltage input band of 90 Volt to 550 Volt , 45 - 65 Hz. (v) Current measuring 10 mA - 5A , Suitable for CT x/1A and x/5A. (vi) Commissioning without additional settings and programming. (vii) Three decimal power factor reading.
(DEMOLITION B/R & E/M) Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of Reinforced Cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed.
Dismantling timber scantling 40 sqcm & over in section framed in any position complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling asbestos cement (corrugated or semi corrugated, etc) sheets in roof covering complete all as specified and directed.
Dismantling asbestos cement/PPGL (corrugated or semi corrugated, etc)sheets in roof covering complete all as specified and directed.
Demolition of reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including debris to a place exc 1.5 Km but n.exc 5 Km outside MD land complete all as specified and directed.
(DEMOLITION E/M) Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete all as specified and directed.
Taking down carefully aluminium submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete all as specified and directed.
(HOT AND COOLING APPLIANCES) S&F voltage stablizer for automatic operation, single phase naturally air cooled, indoor type, ISI marked, digital wall mount type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +/- 2.5%, insulation class B, with inbuilt electronic over load trip , protection against high / low voltage & timer for 10 seconds , efficiency more than 97 % and of capacity 2.0 KVA complete all as specified and directed.
S&F voltage stablizer for automatic operation, single phase naturally air cooled, indoor type, ISI marked, digital wall mount type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +/- 2.5%, insulation class B, with inbuilt electronic over load trip , protection against high / low voltage & timer for 10 seconds , efficiency more than 97 % and of capacity 4.0 KVA complete all as specified and directed.
S&F refrigerator, electric driven (single phase), double door, with inbuilt stabilizer, capacity upto 310 Ltrs BEE 5 star rated complete all as specified and directed.
Supply, Install, Test and commisioning of air cooled split unit air conditioner indoor and outdoor unit, electric driven, single phase 230V, 50Hz with minimum 3Mtr long copper pipe duly insulated and electrical cable of suitable size, mounting bracket and required accessories for installation all as specifed and commissioning with following Specification:-
(a) Capacity - 1.5TR / 4500 K-Cal/Hr (b) Technology - Variable speed dual Inverter Technology (c) Compressor Type - High EER Twin rotory compressor (d) Operating Voltage range - 145V-270V (without stabilizer) (e) Condenser Coil- 100% Copper (f) Star Rating- 5 Star (g) Warranty on compressor - Minimum 5Years (h) Air Filter- Anti dust, anti bacteria
RAIN WATER HARVESTING M&L for construction of Rain Water Harvesting Pit complete all as specified and shown on drawing as per drawing CE (Fy) Hyderabad TD No TD/STR/14.
ARBORICULTURE Supply and planting of below mentioned trees in 0.25- 0.3M poly bags with height 1.5 M to 1.8 Mtr incl digging holes 1.2M dia x 1.2 Mtr deep in ordinary soil and reffiling the same with the excavated earth mixed with manure or sluldge in the ratio 2;1 (02 parts of stacked volume of earth after reduction of 20% with 1 parts of stacked volume of sludge of manure after reduction by 80% flooding with water and removed of surplus soil complete all as specified and directed.
Casoraina (Casuarina equiser folia)
Canary date Palm (Phonix Canariemsis)
Amaltas (Cassia Fistula)
Neem (Azadirachta Indica)
Gulmohar (Delonix Regia)
Ashoka (Saroca Asoca)
Jasmine (Holarrohena Pubescens)
Alortonia (Alstonia Scholoris)
Bottle Brush (Callistemon)
Rose (Rosa Rubiginosa)
Bougainvillea
Battle Nut (Areca Catechu)
Supply and laying of lawn grass plantation of semi carpet grass approved by GE over and including filling the excavated area with good yellow soil 200 mm thick mixing with sand, festicides ATT providing ATT and appropriate fertilizers levelling etc and maintaining it for two years complete all as specified and directed.
Regular maintenance of trees speciman plants, lawn area grass and other similar plants for two years after certified date of completion issued by GE by employing one experience Mali per day. The maintanence shall include the following:- (i) Periodical de-watering of unwanted vegetation growth around the plant. (ii) Watering all the trees / plants / grass and soil with required for proper growth. (iii) Periodical pruning the shurbs. iv) Treating the trees / plants grass and soil with required quantity of approved manure, pesticides and fertilizer including necessary topping of rede earth. (v) Replacement of dried / dead plant / grass / trees. (vi) Hose pipe to be arranged by the Contractor.
Pronv of MS Tree guard 450 mm dia, 1.50 m high with MS wiremesh of size 78mm x 37mm and 2mm dia of wire and MS angle iron 20x20x3mm verticals (3 Nos) 1.95 m long, 30 cm burried in ground & MS flats 14x3 mm around the tree guard (3 Nos @ top, middle and bottom) equally spaced and embedded vertical angles in PCC (1:3:6) Type C-1 including excavation in post holes and removal of excavated soil to a n. exc. 50 m and applying two coat of synthetic enamel paint including one coat of red oxide primer to tree guard and all as specified and directed.
S&F CP sprinkler suitable for 15 mm bore pipe along with adjustable stand of height 45 to 60 cm with all arrangments complete all as specified and directed.
PROVISIONAL LUMP SUM (PLS) Provide Provisional lump sum for: (a) Volley Ball Ground - 2 Nos (b) Basket Ball Ground - 2 Nos complete all as specified and directed.
NOTE FOR ITEM NO 70.00:- 1) Provisional lump sum shall be expended wholly or in parts as directed by GE. The works (Except excavation and earth work) under Provisional Lump Sum shall be measured and paid for at applicable rates in MES SSR 2020 Part-II subject to percentage ( + or - denomination) computed under last column of this schedule above/below the provisional lump sum price worked out by the MES. (2) For details refer relavent TD drawings. excavation and earth work against PROVISIONAL LUMP SUM shall be measured and paid under Sch 'A' Part-II.
LUMOS INFRA PVT LTD
DHARIWAL TRADERS PRIVATE LIMITED
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
FRIZO INDIA PVT LTD
SHREE GURUKRUPA CONSTRUCTION CO.
RAGHUSONS INFRA ENGINEERING PVT. LTD
ASHISH JINDAL BUILDERS PVT. LTD.
SOOD ASSOCIATES PVT LTD
Jeet Construction
Hariom Projects Pvt Ltd
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid