| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-AOC Due to lowest. | |
| 2 | L2₹22.4 L+₹32,642 (1.48%)Rejected-Finance 6 1 SERANG LANE KOLKATA 700014 BARASAT NORTH 24 PARGANAS | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700014 | L2 | Rejected-Finance Due to 2nd lowest. | |
| 3 | L3₹22.5 L+₹39,689 (1.80%)Rejected-Finance 39A PATALDANGA STREET KOLKATA 700009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | L3 | Rejected-Finance Due to 3rd lowest. | |
| 4 | Rejected-Technical NICHUPALLY BOLPUR BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
Refer Docs
EMD Value
₹43,797
Closing Date
23 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_PED_2021
RANCHI ROAD_PURULIA
External Electrical _ allied work _excluding internal electrification_ for proposed different building of Purulia Government Engineering College _Ramkrishna Mahato Government Engineering College_ in the District of Purulia_ Allied Electrical Installa
2021_WBPWD_323077_1
WBPWD/EE/PED/NIQ38_3rd Call/2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
42 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹43,797
20 Dec 2021
4 Feb 2021
26 Feb 2021
5 Feb 2021
23 Feb 2021
5 Feb 2021
120 days
Amount
Supply,erection & installation of outdoor hooded type KIOSK made of 3 mm thick MS sheet having height-1400 mm, width-1000 mm & depth-750 mm provided with gasketed double leaf double door arrangement. The doors should have both railway type locking arrangement as well as pad locking system. The Kiosk shoul be provided with four nos lifting lugs on opposite sides of vertical walls.The Kiosk to be provided with brass mesh for proper ventilation at the top at the fixed two vertical sides of the body of the Kiosk. The hood of the Kiosk should be extended sufficiently to prevent rain water infiltration through the brass mesh and the door leafs to be overlapped sufficiently to prevent rain water ingress inside the kiosk.There should have at least 2 (two ) nos earthing terminals provided on the opposite fixed vetical outer walls near the base.All inside and outside walls to be painted with two coats of synthetic enamel paint over one coat of R.O. primer. The kiosk to be erected on the brick pedastal of size 1600 mm x 1200 mm & height -600 mm having hollow space inside filled with dry sand and neat cemented finish with properly maintained slope on the outside to prevent water logging at the foot of the Kiosk provided with cable entry and exit facilities at the base of the pedastal. The metal structure should have self supporting and long angle iron legs having bifercation at the bottom for grouting inside the muffing of the pedastal.The kiosk to be provided with two layers of horizontally alligned 50 mm x 5 mm MS flats welded properly with the body of the kiosk in which each layer should have at least 4(four) nos of MS flats with holes provided with proper size of nuts and bolts for fixing switches and bus bars so that all switches and bus bar chamber can be fixed in door facing orientation.The Kiosk to be provided with the followings-
415 Volt, 250 amps Four pole on load change over switch with HRC fuses (Make-L & T) as incomming switch-1 no.
415 V, 400 amps,4 bar copper bus bar of size 50 mm x 5 mm with chamber of adequate size- 1 set., 50mm x 5mm x 4 No. [each 0.75mtr length]
415V, 100 A TPN SFU with 3 nos DIN type HRC fuses ( L & T )-3 Set
415V, 63 A TPN SFU with 3 nos DIN type HRC fuses ( L & T )-2 Set
415 V,32 Amps SPN main switch with HRC fuses (L & T)- 1 Nos.
EI Danger Board of size 12" x 8" - 2 sets
CTs of range 250/5 Amps -3 set
LED Indicating Lamps (R-Y-B) with fuse/SPMCB - 3 nos
All inter connections to be made with proper size of ' PVC insulatd Aluminium cables with proper socketing/aluminium flates having proper holes, nuts bolts as requires..
Supply,erection & installation of outdoor hooded type KIOSK made of 3 mm thick MS sheet having height-1400 mm, width-1000 mm & depth-750 mm provided with gasketed double leaf double door arrangement. The doors should have both railway type locking arrangement as well as pad locking system. The Kiosk shoul be provided with four nos lifting lugs on opposite sides of vertical walls.The Kiosk to be provided with brass mesh for proper ventilation at the top at the fixed two vertical sides of the body of the Kiosk. The hood of the Kiosk should be extended sufficiently to prevent rain water infiltration through the brass mesh and the door leafs to be overlapped sufficiently to prevent rain water ingress inside the kiosk.There should have at least 2 (two ) nos earthing terminals provided on the opposite fixed vetical outer walls near the base.All inside and outside walls to be painted with two coats of synthetic enamel paint over one coat of R.O. primer. The kiosk to be erected on the brick pedastal of size 1600 mm x 1200 mm & height -600 mm having hollow space inside filled with dry sand and neat cemented finish with properly maintained slope on the outside to prevent water logging at the foot of the Kiosk provided with cable entry and exit facilities at the base of the pedastal. The metal structure should have self supporting and long angle iron legs having bifercation at the bottom for grouting inside the muffing of the pedastal.The kiosk to be provided with two layers of horizontally alligned 50 mm x 5 mm MS flats welded properly with the body of the kiosk in which each layer should have at least 4(four) nos of MS flats with holes provided with proper size of nuts and bolts for fixing switches and bus bars so that all switches and bus bar chamber can be fixed in door facing orientation.The Kiosk to be provided with the followings-
415 Volt, 100 amps Four pole on load change over switch with HRC fuses (Make-L & T) as incomming switch-1 no.
415 V, 200 amps,4 bar copper bus bar of size 20 mm x 5 mm with chamber of adequate size- 1 set., 20mm x 5mm x 4 No. [each 0.75mtr length]
415V, 100 A TPN SFU with 3 nos DIN type HRC fuses ( L & T )-3 Set
415V, 63 A TPN SFU with 3 nos DIN type HRC fuses ( L & T )-2 Set
415 V,32 Amps SPN main switch with HRC fuses (L & T)- 1 Nos.
EI Danger Board of size 12" x 8" - 2 sets
CTs of range 250/5 Amps -3 set
LED Indicating Lamps (R-Y-B) with fuse/SPMCB - 3 nos
All inter connections to be made with proper size of ' PVC insulatd Aluminium cables with proper socketing/aluminium flates having proper holes, nuts bolts as requires..
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts [G-1/2(b)]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe [G-2/3(a)]
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S. [G-2/3(b)]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil [G-1/1(b)]@ 1.75cubic mtr/earth
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. [G-3/5(e) ]
Supply of 1.1 KV grade 4 core 120 sq mm PVC, Armoured Aluminium Cable. [NS ]
Supply of 1.1 KV grade 4 core 70 sq mm PVC, Armoured Aluminium Cable. [NS ]
Supply of 1.1 KV grade 4 core 35 sq mm PVC, Armoured Aluminium Cable. [NS ]
Supply of 11 KV grade 2 core 16 sq mm PVC, Armoured Aluminium Cable. [NS ]
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand [ F-3/4 (a) ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammedLaying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [ F-2/1(a) ]
Laying of one No. cable above 35 sq mm and upto 185 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammedLaying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [ F-2/1(b) ]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ F-1/2(a) ]
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [ F-1/2(c) ]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [ F-1/2(d) ]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [ F-1/2(e) ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 core 120 sq mm [F-4/7(c)]
4 core 70 sq mm [F-4/7(c)]
4 core 35 sq mm [F-4/7(c)]
2 core 16 sq mm [F-4/7(a)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 core 120 sq mm [F-5/8(b) ( xix)]
4 core 70 sq mm [F-5/8(b) ( xvii)]
4 core 35 sq mm [F-5/8(b) ( xv)]
2 core 16 sq mm [F-5/8(b) ( iv)]
Supplying and fixing 415V 63A, TPN SFU(L & T) with sheet steel enclosure on flat iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [ D-3/ 4 (a)]
Supplying and fixing 415V 125 A four pole onload Changeover switch(L&T) with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [ D-2/3(a)]
Supplying & erection of foundation of 125 KVA D.G.Set(silent) at outdoor having dimension given below a)4 inch deep(below ground)PCC of size 4500 mm x 1600 mm & 300 mm above G.L. b) 15 inch thick brick wall, 4 inch deep PCC keeping central part as follows- c) Filling the hollow portion with mixture of sand & shifted soil. d) 6 inch deep RCC with 12 mm double mesh rod at the top of the brick foundation of size4500 mm x1600 mm x 300 mm incl providing foundation bolts,jum nuts etc.
Supplying & erection of foundation of 50 KVA D.G.Set(silent) at outdoor having dimension given below a)4 inch deep(below ground)PCC of size 3400 mm x 1600 mm & 300 mm above G.L. b) 15 inch thick brick wall, 4 inch deep PCC keeping central part as follows- c) Filling the hollow portion with mixture of sand & shifted soil. d) 6 inch deep RCC with 8 mm double mesh rod at the top of the brick foundation of size 3400 mm x1600 mm x 300 mm incl providing foundation bolts,jum nuts etc.
Charges for marking and making single line CAD diagram of the whole Electrical installation works ( both old and new ) and print those on poly vinyl sheet.
SHATABDI ENGINEERING AND CONSULTANCY
M/S ENGINEERING SYNDICATE
stage.html
html • 0.05 MB
technical_613696.pdf
PDF • 0.67 MB
techsummary_613696.pdf
PDF • 0.74 MB
finance_613696.pdf
PDF • 0.73 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_613696.pdf
PDF • 0.65 MB
AOC.pdf
PDF • 0.09 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .