Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Accepted being lowest and quoted amount found reasonable. |
| 2 | L2₹1.5 Cr+₹25.3 L (20.9%)Rejected-Finance | ₹1.5 Cr+₹25.3 L (20.9%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹1.5 Cr+₹25.5 L (21.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹1.5 Cr+₹25.5 L (21.0%) | L3 | Rejected-Finance ejected being L3 |
| 4 | L4₹1.6 Cr+₹42.6 L (35.1%)Rejected-Finance BU 02 SFS FLATS OUTER RING ROAD PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹1.6 Cr+₹42.6 L (35.1%) | L4 | Rejected-Finance ejected being L4 |
| 5 | Rejected-Technical WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | - | - | Rejected-Technical Neither uploaded nor submitted details of Residual Work in Hand as per Note 1 on Page No 11 of NIT and Certificate as per Para 5.2 on Page No 08 of tender documents. |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
28 Jun 2022, 6:00 pmClosed
CE NW KOCHI
CHIEF ENGINEER NAVAL WORKS MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI 682 004
SPECIAL REPAIRS TO LES VAJRA AC PLANT 106 TR AGAINST BER AT INS VALSURA JAMNAGAR
2022_MES_524446_1
891017
Open Tender
Civil Works
Item Rate
240 days
JAMNAGAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
Yes
GE (I) (NAVY) JAMNAGAR
₹2.0 L
Yes
5 Aug 2022
17 May 2022
1 Jul 2022
18 May 2022
28 Jun 2022
14 Jun 2022
Amount
Taking down existing Central air conditioning plant 2X 53 TR capacity consisting of Chiiler of cap 53 TR each, Condensing water circulation pumps 2 Nos, Chilled water pump Sets 3 nos, LT Panels 1Nos including MCCB's MCB's Starters, AHU 2 Nos Make up Water tanks of requisite capacity, cooling tower with metallic fan including storage water tank insulated chilled water piping as laid on supports, GI sheet ducting of various sizes, Various types grills etc complete as and where laid and various sizes of LT Cables, control cables, etc and removing off the site complete all as directed by Engineer in Charge
WATER COOLED SCROLL TYPE CHILLER OF CAPACITY ( 2 X 51 = 102 TR) WITH CFC FREE R-407C/410A REFRIGERANT
Design supply, Insatllation, Testing and Commissioning of water cooled, floor mounting type water chilling machine of minimum Capacity 102 TR (2 x 51 TR) complete with sealed Scroll type multiple compressors, star-delta starter, Shell & Tube Chiller, water cooled fin & tube type Condenser, Condenser fans with weatherproof motors, common Base frame / skid structure, Interconnected Copper Refrigerant piping, Vibration Isolators, Gauge Panel, Flexible connectors at Chiller connections, Automatic Safety Controls, Ozone friendly CFC Free Refrigerant Gas R-407C/410A & Oil, Nitrile Rubber Insulation of chiller & Suction pipe etc. Design Condition :- 22 +/ -2 RH 55 +/ - 5% as per user data sheet.
The Motor shall be suitable for operation on 415 ±10% V, 50 Hz, 3 phase AC power supply. Chilling machine shall be complete with its Micro processor based Control Panel & Starter with main switch. Chiller panel shall be compatible for remote operation & should provide status (additional potential free contacts shall be required to perform this function) Necessary civil work such as PCC foundation for placement of chillers to be covered in the scope of work.-- 02 Nos
The chiller shall be as per the technical specifications. The water chilling machine shall meet the following design parameters: Actual Minimum Cooling Capacity of each unit required : 51 TR @ Local Ambient conditions Chilled Water leaving Temp. : 44°F ( 6.6.Deg.C.) Chilled Water entering Temp. : 54°F ( 12.2 Deg.C.) Evaporator fouling factor : .0005(FPS) IKW/TR : Not exceeding 1.3 Refrigerant ( Ozone friendly type ) : R-407c / R-410 a
Make of Compressor :- As recommended by OEM or manufacturer of Chiller Unit. Make of chiller unit: - VOLTAS / CARRIER / DAIKIN / HITACHI Notes :- (a) Contractor before quoting the tender will visit the site, calculate tonnage, check the design to meet the cooling parameter and feasibility of installation of design and specification provided by the department. (b) Bidder may do his own design to satisfy himself that the design is sufficient to attain the desired parameters. Any shortcomings noticed shall be made good by the contractor without any extra cost to the Department which shall be accounted for in the amount quoted and nothing extra will be payable to the contractor. (c) Accessories, fittings, supporting items complete as specified in BOQ shall be included in the rate. No extra payment shall be allowed for the same.
Note for BOQ Item Nos 2, 3, 4, 5, 9, 54 & 55 :--- All civil work for PCC Foundation as recommendation of manufacturer are required for installation of AC plant shall be deemed to be included in the rated quoted against the item. No extra payment shall be made on account of this.
Supply, install, testing and commissioning FRP included draft cooling tower rectangular/cylindrical type complete with FRP basin capacity suitable for 125 TR (minimum) all as required for water cooled chilling machine 102 TR capacity complete installed on PCC / brick staging with spray section, honey comb fill basin, MS girders, Ladder, statically & dynamically balanced axial flow fan direct driven or driven through reduction gear box with suitable capacity of induction TEFC Motor working on 415 V +/- 10%, 3 phase,50 Hz AC supply, intake, make up quick filling arrangement, bird screen necessary valves for intake, drain & overflow and other accessories
CHILLED WATER PUMPSETS - HORIZONTAL BACK PULL OUT TYPE WITH INSULATION : Supply, installation, testing and commissioning of end suction & top discharge type centrifugal pumps back pull out type for chilled water recirculation complete,with cast iron body, bronze impeller complete with mechanical seals, TEFC squirrel cage high efficiency induction motor, base plate, mounting channel frame, accessories and fittings i.e. flexible connectors (bellows ) at inlet & outlet connections, mechanical seal, pressure gauges, thermometers , drains, coupling, couplings, guard, vibration isolation arrangement by means of resistoflex make as specified of the following capacities and shall be suitable for operation on 415 +/ - 10% volts 50Hz, 3 Ph AC Suppl. The pumps shall be insulated with Nitrile Rubber with suitable thickness including necessary foundation as recommended by manufacturer. NOTE : Each pump capacity shall be suitable for 100% working (01 Working + 01 standby) a) Capacity :- Discharge minimum 320 USGPM or as recommended by the manufacturer of chilling unit. b) Head ; - 35 Mtr ( Contractor to check and verify the pump head as per site requirement) c) Impeller : -- Bronze d) Elect Motor capacity: As recommended by the manufacturer of pump e) Make of Pump :-- Beacon / Kirloskar/CRI / Crompton / KSB/ Wilo Mather/ Jyoti/ V Guard f) Make of Motor :-- Crompton/ Kirloskar/ Siemens/ ABB/ NGEF/ Bharat Bijlee
CONDENSED WATER PUMPSETS - HORIZONTAL BACK PULL OUT TYPE WITH INSULATION : Supply, installation, testing and commissioning of end suction & top discharge type centrifugal pumps back pull out type for condensed water recirculation complete,with cast iron body, bronze impeller complete with mechanical seals, TEFC squirrel cage high efficiency induction motor, base plate, mounting channel frame, accessories and fittings i.e. flexible connectors (bellows ) at inlet & outlet connections, mechanical seal, pressure gauges, thermometers , drains, coupling, couplings, guard, vibration isolation arrangement by means of resistoflex make as specified of the following capacities and shall be suitable for operation on 415 +/ - 10% volts 50Hz, 3 Ph AC Suppl. The pumps shall be insulated with Nitrile Rubber with suitable thickness including necessary foundation as recommended by manufacturer. NOTE : Each pump capacity shall be suitable for 100% working (01 Working + 01 standby) a) Capacity :- Discharge minimum 380 USGPM or as recommended by the manufacturer of chilling unit. RPM - 2900 b) Head ; - 25 Mtr ( Contractor to check and verify the pump head as per site requirement) c) Impeller : -- Bronze d) Elect Motor capacity: As recommended by the manufacturer of pump e) Make of Pump :-- Beacon / Kirloskar/CRI / Crompton / KSB/ Wilo Mather/ Jyoti/ V Guard f) Make of Motor :-- Crompton/ Kirloskar/ Siemens/ ABB/ NGEF/ Bharat Bijlee
NOTE for item 1 to 5 here-in-before : Unit rate quoted by the contractor deemed to be included for the followings:- (i) Submission of floor Drgs& details, Lay out plan for equiptsetc for approval by accepting officer. (ii) Providing all minor parts which are not included in brief specification but required technically at site for Installation, commissioning, testing of entire plant to achive designed condition & efficient performance, smooth functioning of the plant. (iii) PCC works for foundation as per manufacturer instruction, plastering, Earth works (iv) submission of catalogues for major eqpts (v) Internal wiring for auto function and safety measures of eqpts. (vi) Arrangement for providing testing instruments and artificial load if required for phase I & II testing.
Supply and Fix Balancing Valve 65/80mm dia for Chilling plant of suitable sizes and specification and as directed by Engineer in charge
Supply and Fix Balancing Valve 65/80mm dia for AHU of suitable sizes and specification and as directed by Engineer in charge
Supply and fixing 25 mm thick Double Skin type Air Handling Unit 16000 CFM capacity with 10 Micron Pre filters 6 row deep coil with starter Panel with following description :- a) Double skinned type horizontal floor mounted, top / side discharge air handling unit with double skin Thermal break aluminium profile construction using 22 G sheet metal sandwitch panels with 43 mm thick injected spray type PUF panels, density 38Kg/CuM. The AHU shall be as per the specification under section "Double skin Air Handling Units" in the tender document. b) Fan section with AMCA Certified backward curved type Blower with outlet velocity not exceeding 9.2 m/sec .
c) Drive motor suitable for 400 +/- 15% V, 15 HP or suitable rating 50 Hz, 4P, TEFC squirrel cage high efficiency induction motor and BHP rating 20% higher than the peak capacity. d) V belt drive assembly with pulleys, belt guard, etc., double canvass / rexin connections with zip to discharge duct/ plenum etc. e) Filter section consists of 50 mm thick washable HDPE 90% down 10 micron Pre-Filters, 3 Micron Micro Vee Filters fixing Framework, hinge type access doors,etc. f) 6 Row deep Chilled water Coil section with Chilled water coil should be as per ARI condition, aluminum finnes and copper tube, tested on 21KG/Cm2 with SS sandwitched Drain tray etc.
g) 18 Gauge MS CRCA duly powder coated AHU Sub Panel board in compartmentalized construction with Incomer and Outdoing feeders for AHU Motor, 3 Way Valve actuator motor, Fire Damper actuatotr motor etc. complete with required control switches, relays, times, contactors, voltage transformer, push buttons, switches, internal wiring etc. h) Accessories like Hinges type Access doors for Filter section, Fan section etc., Sight glass, Marine Lamp with limit switch, Supply, Return and Fresh Air flanged type connections with low leakage air foil design Dampers, Rubber sleeves for Pipe & Cable entry, Flow direction arrows, Vibration isolation spring type pads, Motor sliding Rail etc. Static pressure (mm) -80 with 10 micon pre-filters, Make of AHU:- Bluestar/ National/ Zeco/ Voltas
Supply, installation, testing & commissioning of Mild Steel Chilled Water Piping 65mm dia of class 'C', Heavy duty confirming to IS: 1239 (Part-1) 1991 & IS: 3589-1991Grade 330 cut to required length, and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supports, air purge valves, drain valves etc. complete all as specified Make : TATA / JINDAL / ZENITH / SURYA PRAKASH
All as per item No 10 here-in-before but MS Chilled Water piping of 80mm dia
All as per item No 10 here-in-before but MS Chilled Water piping of 100mm dia
All as per item No 10 here-in-before but MS Chilled Water piping of 150mm dia
All as per item No 10 here-in-before but MS Chilled Water piping of 200mm dia
Supply, installation, testing and commissioning of PN 1.6 Butterfly valves of 65 mm dia duly insulated with companion flanges, nuts, bolts, gaskets etc. as specified. Butterfly valves with cast iron body, seat of black nitrile rubber, nylon coated S.G. iron disc, PTFE coated SS (AISI 410) shaft etc. as required. These valves shall confirm to BS: 5155, MSS SP 67 & API 609 and shall be designed to fit without gaskets between mating flanges. The valves shall be suitable for flow in either direction and seal in both directions. The valves shall be of integral moulded design.
All as per item No 15 here-in-before but 80 mm dia
All as per item No 15 here-in-before but 100 mm dia
All as per item No 15 here-in-before but 150 mm dia
All as per item No 15 here-in-before but 200 mm dia
Supply, installation, testing & commissioning of PN 1.6, 3-way modulating valves 65-100 mm dia for AHU's chilled water coil application complete with motor actuator, thermostate, voltage transformer, flanges, nuts-bolts, gaskets duly insulated with 50mm thick TF Quality as specified and required all as directed by Engr-in-charge. Make:- Honeywell / Rapid control/ Anergy
Supply and fixing in position flow switch complete with copper conductor control wiring at chiller outlet of each machine confirming to IS 3589 of 6 mm thick duly tested all as directed by Engr-in-charge Make. H GURU, FIBIEG, HONEYWELL, ANERGY
Supply, installtion,testing and commissioning of Wafer Swing Check type Non- Return Valve 100/80 or suitable size dia, PN -1.6 rating with cast iron body,flanges, gaskets etc with insulation all as directed by Engr-in-charge.
Supply, installation, testing & commissioning of 100 mm dial type Pressure Gauge with appropriate range & SS valves and SS tubing all as directed by Engr-in-charge.
Supply, installation, testing & commissioning in length 150 mm dial type Temp Gauge with appropriate range & SS valves and SS tubing all as directed by Engr-in-charge. Make: Honeywell / Rapid control/Flebig/H-Guru
Supply, installation, testing & commissioning of 25 mm dia. Auto Air Purge valve for chilled water piping all as directed by Engr-in-charge. Make : H GURU, FIBIEG
Supply, installation, testing & commissioning of 40/25 mm dia. Ball type Drain valve for chilled & Cooling water piping all as directed by Engr-in-Charge. Make : Leader / Sant/ Castle
Supply, installation,testing and commissioning of site fabricated MS channel / angle supports structure / pipe rack for the piping and the ducting work all as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of galvanised steel sheet (G.S.S.) square/ rectangular ducting fabricated from galvanised steel sheet of 24 gauge galvanized sheet steel (0.63mm) having zinc coating of 120 gm/sq.m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 (Revised upto date) and including with required scaffolding work to install the ducts all as directed by Engr-in-Charge. Make : JINDAL / SAIL / ISPAT/ TISCO (TATA). Note:- After completion of work contractor should provide display board showing line diagram of ducting in AHU room
All as per item No 28 here-in-before but using galvanised steel sheet of 22 gauge galvanized sheet steel (0.80mm)
All as per item No 28 here-in-before but using galvanised steel sheet of 20 gauge galvanized sheet steel (1.00mm) for SA Plenum
M&L for duct insulation with resin bonded nitrile rubber insulation 13 mm thick with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:- (a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage (b) M&L for applying rubber based adhesive CPRX compound (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50mm wide, to make the insulation leak proof (d) M&L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12mm/50mm at maximum intervals of 1.2mtr
M&L for insulation for MS pipe 65 mm dia with thermocol PUF slab 30mm thick with and including applying bituminous compound and aluminium cladding complete all as specified and directed
All as per item No 32 here-in-before but for MS pipe 80 mm dia
All as per item No 32 here-in-before but for MS pipe 100 mm dia
All as per item No 32 here-in-before but for MS pipe 150 mm dia
All as per item No 32 here-in-before but for MS pipe 200 mm dia
M&L for underdeck insulation for RCC roof with thermocol PUF 50 mm thick of density 20 Kg / cum with suitably factory laminated with aluminium foil having flange on one side, backed up by scrim and kraft paper, comprising of the following (insulating material shall confirm to BS-476 Part 4, 5, 6 & 7):- (a) S&F 50 x 50mm or 75 x 75mm slotted angles 50mm wide, fixed to the ceiling by means of rawl plug 600mm centre to centre (b) Supply & draw GI tie wire 22 Gauge from vertical slots, for holding the insulating material in position with and including GI washer (c) S&F aluminium foil, adhesive tape 50mm for ceiling of aluminium foil flanges (d) Providing additional support to the insulation with and including chicken wire mesh of size 12.5mm x 0.51mm (24 SWG) hexagonal construction, stretched firmly over the insulation and fixed
Supply, installation, testing and commissioning of Supply / Return air Diffusers / Grilles of extruded Aluminium sections duly powder coated with black volume control Damper all as directed by Engr-in-charge. Make: System air / Air flow / AIR MASTER
Supply, installation, testing and commissioning of automatic Fire damper of Fusible Link type as required for operation complete all as specified. ( Note: The fire dampers shall be spring activated on melting of fusible link having melting point of 67 to 68 deg.c. Fire damper shall be tested as per ULL- 555 and certified by CBRI ) all as directed by Engr-in-charge. MAke: _ System air / Air flow / AIR MASTER
Supply, installation, testing and commissioning of 13 mm thick black Nitrile Rubber EPDM quality for Entry Door insulation and to prevent air leakages fixed with cold adhesive all as directed by Engr-in-charge. Make: ARMAFLEX / AEROFLEX / K Flex
Supply and installation of Acoustic insulation with using 18 mm thick open cell Nitrile Rubber to reduce the noise level in duct / plenum all as directed by Engr-in-charge. Make:ARMAFLEX / AEROFLEX / Air master
Supply and fixing XLPE insulated copper conductor armoured cables of 1100 volt grade, 4 core x 25 sqmm Copper for Chiller Units including cost of all crimping lugs and single compression glands, cable sockets insulation tape, sealing compound etc all as directed by Engr-in-charge.
All as per item No 42 here-in-before but 4core x 16 sq.mm Copper for Air Handling Units / Pumps etc.
All as per item No 42 here-in-before but 4core x 10.00 sq.mm Copper for cooloing tower / Pumps etc.
All as per item No 42 here-in-before but 5 core x 1.5 Sq mm copper cable for control cable for auto/ remote system of plant
All as per item No 42 here-in-before but 3 core x 1.5 Sq mm copper cable for control cable for auto/ remote system of plant
All as per item No 42 here-in-before but 2 core x 1.5 Sq mm copper cable for control cable for auto/ remote system of plant
Supply and fix perforted cable tray GI 1.6 mm thick of size 300 mm x 75 mm for cable laying alongwith nylon tie/ clip duly fixed with proper clamping material as directed by Engineer in charge
Supply and fix perforted cable tray GI 1.6 mm thick of size 150 mm x 75 mm for cable laying alongwith nylon tie/ clip duly fixed with proper clamping material as directed by Engineer in charge
Supply and fixing cable XLPE insulated aluminium conductor armoured cables of 1100 volt grade, 3.5 core 240 sqmm including cost of all crimping lugs and single compression glands, cable sockets insulation tape, sealing compound etc all as directed by Engr-in-charge.
All as per item No 50 here-in-before but 3.5 core 150 sqmm
All as per item No 50 here-in-before but 3.5 core 120 sqmm
Supply and fix earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32x6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Supply, installation, testing and commissioning of floor mounted, indoor duty, cubicle & compartmentalized, front access type, medium voltage electric panel of dust and vermin proof , fully tropicalised construction, front openable doors and shutters with locking arrangement, made out of 14 SWG (2.0 mm thick) CRCA sheet steel, factory fabricated, powder coated,suitable for operation on 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply complete with all interconnections and consisting of all accessories like Aluminium Bus Bar of capacity 800 Amps, LED Type Indicating lamps, Push buttons, CTs, Digital Ampere, Voltage, Frequency & KWH meter, Danger Plate, Lifting Hooks, Feeder Name Plates suitable for the following feeders (Note : The Panel shall be of suitable size to accomodate all the accessories mentioned below , installed on Pedestal made out of angle iron of size 50 mm x 50 mm x 6 mm & earth work, PCC foundation, suitable cable glands for cable entry etc.) :-
1.0 Incomer Feeder : a) ACB 630 A TPN 415 volts Manual draw out type with micro thermal based with interrupting breaking capacity 50 KA - 01 Nos 2.0 Outgoing Feeders : a) MCCB 250 Amps micro thermal based with interrupturing breaking capacity 36 KA - 02 nos( for chiller) b) MCCB 160 Amps micro thermal based with interrupturing breaking capacity 36 KA - 02 nos ( for AHU) b) MCCB TP 63 Amps - 04 nos (for Pumpset - 04 Nos) c) MCCB TP 40 Amps - 02 nos (for Cooling tower and bldg lights) e) Star delta starter suitable for pumpset 15/20HP - 4 Nos f) DOL Starter suitable for 5/7.5 HP pumpsets - 01 No g) Auto remote control switches to operate AHU from Plant Room
Supply, installation, testing and commissioning of floor mounted, indoor duty, cubicle & compartmentalized, front access type, medium voltage electric panel of dust and vermin proof , fully tropicalised construction, front openable doors and shutters with locking arrangement, made out of 14 SWG (2.0 mm thick) CRCA sheet steel, factory fabricated, powder coated,suitable for operation on 450 Volts, 3 phase, 4 wire, 50 Hz, AC supply complete with all interconnections and consisting of all accessories like Aluminium Bus Barof capacity 400 Amps, LED Type Indicating lamps, Push buttons, CTs, Digital Ampere, Voltage, Frequency & KWH meter, Danger Plate, Lifting Hooks, Feeder Name Plates suitable for the following feeders (Note : The Panel shall be of suitable size to accomodate all the accessories mentioned below , installed on Pedestal made out of angle iron of size 50 mm x 50 mm x 6 mm & earth work, PCC foundation, suitable cable glands for cable entry etc.) :-
1.0 Incomer Feeder : a) MCCB 160 A TPN 415 volts Manual draw out type with micro thermal based with interrupting breaking capacity 50 KA - 01 Nos 2.0 Outgoing Feeders : a) MCCB125 Amps micro thermal based with interrupturing breaking capacity 36 KA -01 Nos ( for AHU) b) MCCB TP 63 Amps - 02 Nos ( Humidifier and Pumpset ) c) MCCB TP 40 nos - 01 Nos ( Bldg lights) d) Star delta starter suitable for 15/20 HP elect motor - 01 nos
Supply and installation of Electrical Strip Heater, finned type, capacity27 pcs of 3 KW x 3 Banks consisting of stainless steel sheathing having heat resistant chrome-nickel 80/20 element protected under best insulation to avoid the leakage of current and with screwed type terminal at one end, 240 volts, AC, 50Hz, single phase complete with heater plenum for humidity control with Humidistat/Thermostat & safety thermostat with all necessary electric cabling complete all as specified and as directed Make : Industrial/Rapidcool /Daspass
Supply and fixing rigid PVC Expansion tank / Make up water tank duly insulated with 50 mm thick TF quality thermocol and finished with GI chikcen wire mesh and two coats of sand cement platser complete with inlet, outlet, drain and over flow connections with all valves of 2x1000 Ltrs. capacity to be installed at terrace level all as specified and as directed.
Supply, installation, testing and commissioning of 40mm thick TF Quality thermocole insulation for AHU Room fixed with 50 x 50 x 1 mm thick GI Channels frame work and further covered with 26 swg perforated Aluminium sheet all as specified and as directed.
Supplying, installation, testing and commissioning of humidifier pan type 9 KW rating unit complete floor mounted IP 42, with tank construction from 2 mm thick SS sheet, control panel, insulation with fibre glass wool, suitable for operation on 415 volt, 3 phase including door switch, flot valve, thermostat, side glass, low/high level cut-out and all accessories of reputed make all as specified and directed by Engineer in Charge. Make: Daspass or equivalent reputed make approved by GE
Supply, installation, testing & commissioning of Y-Type Strainer C.I / MS body 80 mm dia for Pump, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh 24G X 14 mesh for chilled water application complete with flanges, nuts-bolts, gaskets duly insulated with 50mm thick TF Quality all as directed by Engr-in-charge. Make:- TRISHUL / LEADER / SANT / FLOWEL / HONEYWELL/ RAPID CONTROL
All as per item No 60 here-in-before but 100 mm dia for AHU
Note for Item Nos 1 to 55 : All civil work like masonary wall cut outs and jurry work to pass Pipes, Cables & Ducts at site. Also required PCC foundations for Chillers, Pumps, AHU, Electrical panel board, expansion tank etc. The cutouts shall be closed and finished to the original finish after completion of work are included in the rate.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Supplying and Fixing Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web ceiling belt of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web ceiling belt of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web ceiling belt of 50 mm and flange of 26 mm each with lips belt of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre size of grid 605 x 605mm complete all as specified.
Supplying and Fixing exposed metal frame ceiling 6mm thick with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600X600mm grid including two coats of oil bound distemper over a coat of primer fixed or laid/inserted to Aluminium framework as in false ceiling complete all as specified and directed. Note : Framework for ceiling shall be measured and paid for separately.
Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars, etc, built in cement mortar complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering on brick work or concrete surfaces in cement mortar 1:6 finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of priming coat on newly prepared wall surfaces, including 3 mm thick layer of wall care putty (Birla white or equivalent) all as specified and directed.
M&L complete removal of existing treatment and applying a coat of wall care putty (Birla white or equivalent) and then applying two coats of oil bound distemper over a coat of priming coat after preparation of wall surfaces complete all as specified and directed.
Supply and hoisting and fixing in position rotational moulded polyethylene water storage tank of capacity 5000 ltr (cylindrical vertical with closed top) complete for cooling tower make up
Supply and fixing GI tube medium grade 25 mm dia on ceiling / wall complete
Supply and fixing GI tube medium grade 40 mm dia on ceiling / wall complete
Supply and fix aluminium strip of size 32x6mm complete all as specified
Supply and fix GI strip of size 32x6mm complete all as specified
Supply and fix GI strip of size 25x4mm complete all as specified
M&L preparation of old plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
OUTSOURCING SERVICES DURING FIRST YEAR OF DEFECT LIABILITY PERIOD
Outsourcing of services consisting of 01 No Ref Mechanic for continuous operation of AC Plant of Capacity 2x51/53 TR (LES) at INS Valsura Jamnagar with one operator per shift of 08 hours from 0800 hrs to 1600 hrs in all working days including Sundays & holidays for 12 Months (1st Year after completion of work, during DLP) all as specified and directed by Engr -in-charge. Note:-The unit rate quoted shall be inclusive of all charges such as GST, ESIC, Labour wellfare Cess, over head & profit& Bonus etc.
OUTSOURCING SERVICES DURING SECOND YEAR OF DEFECT LIABILITY PERIOD
Outsourcing of services consisting of 01 No Ref Mechanic for continuous operation of AC Plant of Capacity 2x51/53 TR (LES) at INS Valsura Jamnagar with one operator per shift of 08 hours from 0800 hrs to 1600 hrs in all working days including Sunday& holiday for 12 Months (2nd Year after completion of work, during DLP) all as specified and directeded by Engr-in-charge. Note:-The unit rate quoted shall be inclusive of all charges such as GST, ESIC, Labour wellfare Cess, over head & profit& Bonus etc.
NOTE FOR ITEM NOS 79 TO 82 : (i) Operator should be minimum ITI passed in relevent trade with minimum 02 years experience of running of installation and well conversant with the HT / LT electric supply installation / AC plant with connected panel . (ii) Contractor and his person detailed for manning of AC Plant will be responsible for serviceability of AC Plant . In case of any major fault occurs in AC plant he will be report directly to concerned JE E/M / AGE E/M. Person deputed for operation will be responsible for minor maintenance such as checking of oil, cleaning of plant room and surrounding areas complete. (iii) Safety equipment's will be provided to all tradesman without any extra cost to government. (iv) Necessary weekly off will be given to manpower employed for this schedule as per existing rules and regulation of state /central govt. and necessary replacement will be provided by the contractor. Rates quoted for this schedule shall deemed to be included this provision. (v) Contractor / his operator will be responsible to operate the all above plants / machinery when ever required and as asked / directed by AGE / JE during shift
OUTSOURCING OF SERVICES AND COMPREHENSIVE MAINTENANCE DURING FIRST YEAR AFTER DEFECT LIABILITY PERIOD
Outsourcing of services consisting of 01 No Ref Mechanic for continuous operation with one operator per shift of 08 hours from 0800 hrs to 1600 hrs in all working days including Sunday& holidays for one month and Comprehensive maintenance of 2x51/53 TR AC Plant at LES (1st Year after completion of Defect liability period) including checking and cleaning of followings: (a) Monthly maintenance (b) Quarterly maintenance (c) Half yearly maintenance (d) Yearly maintenance including first hand repairs with all consumables and spare parts for AC plant comprising of Compressors, motors, condenser, refrigerant piping , control, pumps, watersupply pipe line , electrical panel instruments and provn of control cabling/wiring etc complete all as specified and directed by Engineer- in - Charge for smooth and efficient performance of AC plant to achieve desired inside condition throughout the year
OUTSOURCING OF SERVICES AND COMPREHENSIVE MAINTENANCE DURING SECOND YEAR AFTER DEFECT LIABILITY PERIOD
Outsourcing of services consisting of 01 number Ref Mechanic for continuous operation with one operator per shift of 08 hours from 0800 hrs to 1600 hrs in all working days including Sunday& holidays for one month and Comprehensive maintenance of 2x51/53 TR AC Plant at LES (2nd Year after completion of Defect liability period) including checking and cleaning of followings: (a) Monthly maintenance (b) Quarterly maintenance (c) Half yearly maintenance (d) Yearly maintenance including first hand repairs with all consumables and spare parts for AC plant comprising of Compressors, motors, condenser, refrigerant piping , control, pumps, watersupply pipe line , electrical panel instruments and provn of control cabling/wiring etc complete all as specified and directed by Engineer- in - Charge for smooth and efficient performance of AC plant to achieve desired inside condition throughout the year.
OUTSOURCING OF SERVICES AND COMPREHENSIVE MAINTENANCE DURING THIRD YEAR AFTER DEFECT LIABILITY PERIOD
Outsourcing of services consisting of 01 number Ref Mechanic for continuous operation with one operator per shift of 08 hours from 0800 hrs to 1600 hrs in all working days including Sunday& holidays for one month and Comprehensive maintenance of 2x51/53 TR AC Plant at LES (3rd Year after completion of Defect liability period) including checking and cleaning of followings: (a) Monthly maintenance (b) Quarterly maintenance (c) Half yearly maintenance (d) Yearly maintenance including first hand repairs with all consumables and spare parts for AC plant comprising of Compressors, motors, condenser, refrigerant piping , control, pumps, watersupply pipe line , electrical panel instruments and provn of control cabling/wiring etc complete all as specified and directed by Engineer- in - Charge for smooth and efficient performance of AC plant to achieve desired inside condition throughout the year.
NOTE FOR ITEM NOS 84 TO 89 : (i)This item includes all consumables items including filling of refrigerant gas/lubricants oil/filters as required. The quoted rate shall be deemed to be included for replacement of any parts in respect of Chiller plant, Electrical panel, Cooling system, Condensor pump, Cooling tower, gas charging, motor winding, control valves etc for smooth functioning of AC Plant and No extra cost shall be paid on this account. (ii) All instruments/equipments required to check for repair/replacement are to be arranged/provided by contractor. (iii) Though maintenance of Gl ducting is not included, adjustment of grills and repair to grills to achieve proper flow of conditioned air is deemed to be included in the quoted rate of item. (iv) In the event of failure to achieved specified inside condition due to non operation or by other reason (except failure incoming electric/water supply at AC plant room) contractor will be liable to pay penalty at Rs 500/hour upto a maximum Rs 5000 per day (v) In case of failure of any system i.e. chiller plant, AHU, Water recirculation pump etc same shall be repaired by contractor without extra cost to Govt (vi) Quoted rate deemed to include to descaling condenser from both side and using the descaling compound and brushes with long iron rod to clean the copper tubes as and when required. (vii)Cleaning of cooling tower/AHU as and when required for the proper functioning of the plant, rate quoted shall be included for the same.
NOTE FOR ITEM NOS 84 TO 89 (CONTINUED...) : (viii)Operator should be minimum ITI passed in relevant trade with minimum 02 years experience of running of installation and well conversant with the HT/ LT electric supply installation/AC plant with connected panel (ix) Contractor and his person detailed for manning of AC Plant will be responsible for serviceability of AC Plant. In case of any major fault occurs in AC plant he will be report directly to concerned JE E/M/AGE E/M. Person deputed for operation will be responsible for minor maintenance such as checking of oil, cleaning of plant room and surrounding areas complete. (x) Safety equipments will be provided to all tradesman without any extra cost to government (xi) Necessary weekly off will be given to manpower employed for this schedule as per existing rules and regulation of state/ central govt and necessary replacement will be provided by the contractor. Rates quoted for this schedule shall deemed to be included this provision. (xii) Contractor/his operator will be responsible to operate the all above plants/machinery when ever required and as asked/ directed by AGE/ JE during shift. Note:-The unit rate quoted shall be inclusive of all charges such as GST, ESIC, Labour wellfare Cess, over head & profit& Bonus etc.
Jyoti Refrigeration
M/s Jagdish Machinery Stores
Pneumatic Engineers Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .