Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.9 LAccepted-AOC 9 LAXMI NARAYAN PURA RAMPURA UNTI SANGANER JAIPUR RAJASTHAN 302001 | JAIPUR | RAJASTHAN | 302001 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹42.1 L+₹65,881.50 (1.59%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹42.2 L+₹77,585 (1.87%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹43.6 L+₹2.1 L (5.16%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹44.4 L+₹3.0 L (7.27%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹44.9 L
EMD Value
₹89,800
Closing Date
13 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
Garrison Engineer (Naval Base) Nausenabaugh Gandhigram PO Visakhapatnam 530 005
COMPREHENSIVE MAINTENANCE OF NAVAL DOCKYARD UNDER AGE B/R-III OF GE (NB) VISAKHAPATNAM
2022_MES_548676_2
C/8088/22-23/E8 / Token 62 of 2022-23
Open Tender
Civil Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹89,800
Yes
31 Oct 2022
29 Sept 2022
15 Oct 2022
29 Sept 2022
13 Oct 2022
6 Oct 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for Vitrified, designed, dark shade/double charged/ ultracharged coloured, tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Vitrified, designed, light shade coloured, tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm as in vertical surfaces such as skirting,dado, etc including 10 mm thick bedding in cement mortar 1:4 and necessary cutting of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Glazed, ceramic, coloured tiles of size 300mm x 200mm x 6-7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed.
S & F 0.80mm thick, Plain, galvanised, mild steel sheeting, made to shape of required profile for deck sheet to magazine flooring at first floor level of the buildings by provided 100mm side lap and 100mm end lap, fixed to MS joist/beams with self tapping screws of suitable size with grade of zinc coating 275 complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid etc complete all as specified and directed.
S & F GI frame work for suspended seamless false ceiling comprising of GI ultra perimeter channels of size 0.55 mm thick having one flange of 20 mm and another flange of 30 mm and a web of 27 mm alongwith perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610 mm centres. then suspending GI ultra intermidieate channels of size 45 mm, 0.9 mm thick with two flanges of 15 mm each from the soffit at 1220 mm centres with ultra ceiling angle of width 25mmx10mmx0.55 mm thick fixed to soffit with GI cleat and steel expansion fasteners. Ultra ceiling section of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm are then fixed to the ultra intermidieate channel with the help of connecting clips and in direction perpendicular to the ultra intermidieate channel at 457 mm centres including provn of 12 mm thick Gypsum board (Confirming to IS-2095-1982) fixing with screw mechanically either with screw driver or drilling machine with suitable attachment. Finally the boards are to be jointed and finished so as to have a flush look which includes filling & finishing theedges of the boards with jointing conmpound, paper tape and Preparing new surfaces and applying two coats of acrylic emulsion paint over a coat of primer complete all as specified and directed.
Opening the cover and Cleaning of Manholes of any depth and size by pumping out the sewage water completely inluding disposing off sludge and other materials obtained from the manholes to a distance outside MD land, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.75 kg/Sqm and dressing of surplus soil around slope complete all as directed by the Engr-in-Charge.
Cleaning the blockage in the Gully Trap of any size completely enable the sewage to flow freely to the next manholes, removing the sludge and other materials from the Manholes by suitable means and removing all the materials obtained from the manholes out side MD land and cleaning the complete area including making good any damages gully trap complete all as directed by the Engr-in-Charge.
Opening the cover and cleaning of septic tanks, sumps, manholes etc of any capacity, dewatering foul water and taking out night soil, excreta, sludge, etc by pumping properly and removing and carrying the same to a distance upto outside MD land, burried underground (minimum 30 cm below ground level) including necessary excavation and earthwork in soft/loose soil for pits, returning, filling in including sprinkling bleaching powder @ not less than 0.75 Kg/Sqm and dressing of surplus soil around to slope as required including refixing the cover in position and cleaning the eitre area and making good damaged portion (if any) complete all as specified and directed. (Note : (i) Depth of sludge shall only be measured for volume. (ii): The cleaning work shall be carried out by Honey sucker tanker or similar transporter.)
Clearing wash basin/kitchen drainage block from the waste pipes by romving grating and removing waste materials from the traps, bends etc carefully and roding with flexible GI wire to clear the blocking including dipositing the waste materials complete all as directed by the Engr-in-Charge
Clearing blockage from soil pipes or from WC by carefully roding soil pipe with split bamboos or flexible GI wire etc including cleaning the toilet by flushing water and disposing any removed soil materials complete all as directed by the Engr-in-Charge
M & L for Filling of cement mortar in sides of nahani trap, gully trap, rain water pipes out let etc. in CM 1:3 including WPC @ 2% by weight of cement or as per manufacturers instructions and making good finishes to arrest leakage / seepage complete all as specified and as directed.
Cleaning of sewage lines 100 mm bore by rodding from Man holes to enable the sewage to flow freely to the next manholes, inluding disposing off sludge and other materials obtained from the sewage line to a distance outside MD land, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.75 kg/Sqm and dressing of surplus soil around slope complete all as directed by the Engr-in-Charge.
Cleaning of sewage lines 150 mm bore by rodding from Man holes to enable the sewage to flow freely to the next manholes, inluding disposing off sludge and other materials obtained from the sewage line to a distance outside MD land, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.75 kg/Sqm and dressing of surplus soil around slope complete all as directed by the Engr-in-Charge.
Cleaning of sewage lines 200 mm bore by rodding from Man holes to enable the sewage to flow freely to the next manholes, inluding disposing off sludge and other materials obtained from the sewage line to a distance outside MD land, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.75 kg/Sqm and dressing of surplus soil around slope complete all as directed by the Engr-in-Charge.
Cleaning of sewage lines 250 mm bore by rodding from Man holes to enable the sewage to flow freely to the next manholes, inluding disposing off sludge and other materials obtained from the sewage line to a distance outside MD land, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.75 kg/Sqm and dressing of surplus soil around slope complete all as directed by the Engr-in-Charge.
Cleaning of sewage lines 300 mm bore by rodding from Man holes to enable the sewage to flow freely to the next manholes, inluding disposing off sludge and other materials obtained from the sewage line to a distance outside MD land, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.75 kg/Sqm and dressing of surplus soil around slope complete all as directed by the Engr-in-Charge.
Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall and prepared by "Vacuum based sandng machine" and applying one or more coats of wall care putty to a smooth surface and applying two coats of distemper oil emulsion over a coat of alkali resistant primer by "Auto Roller" complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for preparing old decorated surfaces of wall, etc by "Vacuum based sandng machine" including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of distemper oil emulsion by "Auto Roller" complete all as specified and directed.
M & L for preparing old decorated surfaces of walls, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
M & L for preparing old decorated surfaces of ceiling, etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia etc by "Vaccum based sanding machine" and applying one coat of water based acrylic weather proof exterior emulsion (exterior wall finish) paint by "Auto Roller" machine complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc by "Vacuum based sandng machine" and applying two coats of distemper oil emulsion over a coat of alkali resistant primer by "Auto Roller" and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for preparation new external surfaces of wall, chajja, facia etc by "Vaccum based sanding machine" and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer by "Auto Roller" machine as per manufacturer's instruction complete all as specified and directed.
Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately)
M & L for filling polymer modified non shrinking slurry for sunken floors for toilets by drilling holes to a depth of 60mm by 20mm dia at 1 mtr interval and applying 2mm thick brush bond over the concrete syrfaces by mixing acrylic emulsion NITO BOND BB with brush bond powder and water as per the manufacturer's technical specification complete all as specified and as directed. (Make: M/S Fosroc or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd.)
M & L for Plain cement concrete 1:5:10, type E-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Application of one coat of water based bitumen emulision primer @ 0.3 lit per sqm including cleaning of surface thoroughly from dust & dirt and lay APP based polymeric membrane minimum weight 3 Kg/Sqm and a minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150gms/Sqm) shall be laid over tack coat on surfaces and on verticle surface upto and insert in grooves and packed in CM (1:3) with overlaps in membrane 100mm, the over laps shall be sealed by flames or as per manufacturer's instuctions and A coat of hot blown bitumen @ 1.2 Kg/Sqm shall be applied over water proofing membrane complete all as specified and directed.
M & L for PCC 1:1.5:3, type A-1 (using 20mm graded aggregate) as in base over damaged slab for laying tiles etc complete all as specified and directed.
M & L for Racking out and cleaning of tiles joints in affected toilet/bath portion (without disturbing the tiles) and applying white cement 1:3 ratio mixed with pigments and water proofing compound as per manufacturer's instructions to floor & wall maximum upto 1.00m height from floor of affected area complete all as specified and directed.
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed.
S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F 35 mm thick, factory made, glazed/skeleton shutters with first class hard wood, open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I complete all as specified and directed
S & F 35 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete as per specification and drawing and as directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
S & F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
Providing and fixing in repairs Powder coated Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge complete all as specified and directed.
Repair to existing aluminium window shutters of any size by tightening of joints with nuts and bolts, where required including renewal of hinges, handles, beading etc as required to make shutter smooth functioning/movement and making good distrubed portion complete all as directed by the Engr-in-Charge.
M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as in lintel upto 1.5m span, cills and other similar band, plinth course, parapet, railing upto 60cm height, coping, kneelers, bed plates, hold fast block etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 125 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floor complete all as specified and directed.
S & F 300 mm long, mild steel, ordinary rat tail rod pattern springs incuding roller and roller plate complete all as specifed and directed.
S & F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
S & F in repair 18/19mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and directed.
S & F 6 mm thick, for external teak wood lipping to Plywood/particle board etc 18/19mm thick, fixed with nails complete all as specified and directed.
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F in repair PVC over head tank cover suitable for tank of capacity exc 500 but n.exc 1000 Litres complete all as specified and directed.
S & F in repair PVC over head tank cover suitable for tank of capacity exc 1000 but n.exc 2000 Litres complete all as specified and directed.
M & L for cleaning and degermination inside the RCC/PVC water storage tanks of capacity not exceeding 500 ltr of any description and in any position comprising the following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/INCHLOR-5/NB-10, TERBAC G65/INOXI-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) 1st stage: Drain out the water by using exit valve or with high capacity dewatering system or any other suitable method approved by Engr-in-Charge. (b) 2nd Stage: Cleaning all the algae formation inside the tank by using TERBAC G10/INCHLOR-5/NB-10, (a laboratory tested branded chemical) and scrubbing the walls of the tanks. (c) 3rd stage: Cleaning with fresh water by high speed jet pump with pressure of 5 PSI. (d) 4th stage Sterilization by using TERBAC G5/INCHLOR-5/NB-10, (a Laboratory certified branded halogen compound) for first bateria screening. (e) 5th stage: Cleaning the floor of the water tank by heavy duty industrial vaccum cleaner. (f) 6th stage: Sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria for 2nd bacteria screening. (g) 7th Stage: Cleaning and sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TERBAC G65/INOXI-60/NB-69 for third bacteria screening. Note:- (i) Test certificate of TERBAC G65/INOXI-60/NB-69 etc from Government Laboratory mentioning suitability for sterilization should be submitted to the Dept before using for Sterilization. (ii) Cleaning of tank shall only be carried by the authorised service provider of the material used. Necessary approval shall be obtained from GE before cleaning of the tanks, (iii) After cleaning of the tank necessary completion certificate confirming the completion of sterilization of water tank shall be issued by the service provider and a sticker shall be fixed on the tank duly mentioning the date of cleaning and name of site etc)
All as per Serial item No. 79 above but PVC tank of capapcity exc 500 and n.exc 1000 Litres complete ditto
S & F in repair 40 mm dia, Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc including all fitting as required complete all as specified and directed.
S & F in repairs, plastic water closet, Seat and Cover for pedestal pan, white / black, closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
S & F in repairs PVC syphonic kit (any type/any pattern) suitable for 10 litre capacity low level flushing cistern and making the cistern functional in all respectcomplete all as specified and directed.
S & F in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repair 15 mm bore, angular stop valve, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 125 mm size, shower rose, brass chromium plated, swival type, complete all as specified and directed.
Cleaning of air/dust blockages in the internal water supply lines concealed or fixed on the wall or floor surfaces by dismantling the fitting such as taps, valves,unions etc to facilitate/stimulate clearance of blockages/airlocks and Re fixing the dismantled items after clearance of blockage/airlocks complete all as specified and as directed.
K SATYANARAYANA ENTERPRISES
CIVILEC ENGINEERING WORKS
SREE VSM ENGINEERING
M/s Sai Venkata Durga Constructions
M/S S K ENGINEERS
SOUTHERN BUILDERS
KEERTHI ENTERPRISES
MAHIRA ENGINEERING & INFRASTRUCTURE
SRI DHANESWARI ENGINEERING WORKS
M/s SIRI CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .