Raising of Passenger Platform from medium level to High level along with platform shelter of ABS (Abhor) station, Raising of Passenger Platform from medium level to High level along with platform shelter of SAG(Sangrur) station,Raising of Passenger Platform from medium level to High level along with shelter of NLDM (Nangal Dam) station, Provision of Ramps to existing FOB for improving divyangjan accessibility at Tapa & Bhuchchu Railway station,Provision of Hot Axle Box Detector (HABD) system with provision of Electrical supply over Ambala Division, Replacement of existing electro mechanical inter locking with panel interlocking at RTP (Ropar Thermal Power Plant) in SIR-NLDM section of Ambala division, New Running Room at Pilkhani station,Repair of Transformers & allied works and Provision of Bio-toilet testing lab at C&W Depot, Chandigarh over Ambala Division.
30-Elect-T-04-2026-27
30-Elect-T-04-2026-27
Open
6 Months
Chandigarh, Chandigarh
₹0
₹2.9 L
16 Jun 2026
16 Jun 2026
23 Jun 2026
III/1983(latest version) with accessories , junction box etc. including making chase , plastering/clamping etc. as per technical spec. i)25 mm (medium)
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. i) 1.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. ii) 2.5 sq. mm
AMBALA DIVISION-ELECTRICAL/NORTHERN RLY Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iii) 4 sq. mm
conduit including connection, testing & commissioning as per tech. spec.. i) Bakelite ceiling rose 3 plate
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
complete as per specification of CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest. Guarantee-05 years from date of commissioning.
wall as per tech spec for passing cable. i) 50 mm dia
mounted pre fabricated LT distribution Board of approved make as per spec. i) Incoming MCB DP 40 A ,10 KA, (B/C)=01 No.ii)Out going MCB SP 6/32 A 10 KA,(B/C)=06 No.
mounted pre fabricated LT distribution Board of approved make as per spec. i) Incoming MCB TPN,
Foot Description:- Design, manufacture,display, installation of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape.The display sheet shall be of unbreakable
monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site equirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Square
Foot Description:- Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than
calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided.
14 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY 14 Description:- Earthing with 40mm dia. Earth GI pipe class 'B' , 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including construction of masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification.
location with necessary foundation & Nuts-Bolts as per the instruction of the engineer in site
Description:- Design, Supply, testing & commissioning of floor mounted Polycarbonate feeder post of out door type IP-65 of size 500x985x620 mm deep complete with copper bus bar four nos duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals. Thermoplastic Polycarbonate IP 65 in accordance with EN 60 529 (Dust Proof, Water Proof & Weatherproof), Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing,
according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ), Glow wire tested at 960°C in accordance with IEC 60 695-2-11.Type tested as per IEC 61 439- 1. Total Insulated with System. The manufacturer of Polycarbonate feeder post shall submit a copy of CPRI test report of Degree of Ingress Protection IP 65 in accordance with IEC 60529. Each enclosure should have multi no of self-threaded holes. Impact strength should be Ik-08 in accordance with IEC 62262. (The copper Bus Bar will be of 300 Amps rating) as per attached drawing & max input cable size 4Cx120 SQMM. Make Hensel or Similar
method as per site requirement and IS/IE rule. Note: Cable will be laid in HDPE pipe by contractor however cable will be supplied by Railway.
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
fitting and staking of poles within 1km area as per site requirement. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () B-Raising of Passenger Platform from medium level to High level along 707320.22 Below/P with platform shelter of SAG(Sangrur) station ar
III/1983(latest version) with accessories , junction box etc. including making chase , plastering/clamping etc. as per technical spec. i) 25 mm (medium)
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. i) 1.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. ii) 2.5 sq. mm
AMBALA DIVISION-ELECTRICAL/NORTHERN RLY
multi-stranded copper conductor single core cable 1100V conforming to IS 694 ( latest version ) make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iii) 4 sq. mm
conduit including connection, testing & commissioning as per tech. spec.. i) Bakelite ceiling rose 3 plate
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
complete as per specification of CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest. Guarantee-05 years from date of commissioning.
wall as per tech spec for passing cable. i) 50 mm dia
mounted pre fabricated LT distribution Board of approved make as per spec. i) Incoming MCB DP 40 A ,10 KA, (B/C)=01 No.ii)Out going MCB SP 6/32 A 10 KA,(B/C)=06 No.
mounted pre fabricated LT distribution Board of approved make as per spec. i) Incoming MCB TPN,
Foot Description:- Design, manufacture,display, installation of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape.The display sheet shall be of unbreakable
monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site equirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Square
Foot Description:- Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than
calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided.
14 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY 14 Description:- Earthing with 40mm dia. Earth GI pipe class 'B' , 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including construction of masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification.
location with necessary foundation & Nuts-Bolts as per the instruction of the engineer in site
Description:- Design, Supply, testing & commissioning of floor mounted Polycarbonate feeder post of out door type IP-65 of size 500x985x620 mm deep complete with copper bus bar four nos duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals. Thermoplastic Polycarbonate IP 65 in accordance with EN 60 529 (Dust Proof, Water Proof & Weatherproof), Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing,
according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ), Glow wire tested at 960°C in accordance with IEC 60 695-2-11.Type tested as per IEC 61 439- 1. Total Insulated with System. The manufacturer of Polycarbonate feeder post shall submit a copy of CPRI test report of Degree of Ingress Protection IP 65 in accordance with IEC 60529. Each enclosure should have multi no of self-threaded holes. Impact strength should be Ik-08 in accordance with IEC 62262. (The copper Bus Bar will be of 300 Amps rating) as per attached drawing & max input cable size 4Cx120 SQMM. Make Hensel or Similar
method as per site requirement and IS/IE rule. Note: Cable will be laid in HDPE pipe by contractor however cable will be supplied by Railway.
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () C-Raising of Passenger Platform from medium level to High level along 667771.14 Below/P with shelter of NLDM (Nangal Dam) station ar
III/1983(latest version) with accessories , junction box etc. including making chase , plastering/clamping etc. as per technical spec. 25 mm (medium)
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. i) 1.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. ii)2.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated multi-stranded copper conductor single core cable 1100V conforming to IS 694 ( latest version )
Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iii) 4 sq. mm AMBALA DIVISION-ELECTRICAL/NORTHERN RLY
conduit including connection, testing & commissioning as per tech. spec.. i) Bakelite ceiling rose 3 plate
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
complete as per specification of CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest. Guarantee-05 years from date of commissioning.
wall as per tech spec for passing cable. i) 50 mm dia
mounted pre fabricated LT distribution Board of approved make as per spec. i) Incoming MCB DP 40 A ,10 KA, (B/C)=01 No.ii)Out going MCB SP 6/32 A 10 KA,(B/C)=06 No.
mounted pre fabricated LT distribution Board of approved make as per spec. i) Incoming MCB TPN,
Foot Description:- Design, manufacture,display, installation of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape.The display sheet shall be of unbreakable
monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site equirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Square
Foot Description:- Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than
calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided.
Description:- Earthing with 40mm dia. Earth GI pipe class 'B' , 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including
arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification. AMBALA DIVISION-ELECTRICAL/NORTHERN RLY
location with necessary foundation & Nuts-Bolts as per the instruction of the engineer in site
Description:- Design, Supply, testing & commissioning of floor mounted Polycarbonate feeder post of out door type IP-65 of size 500x985x620 mm deep complete with copper bus bar four nos duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals. Thermoplastic Polycarbonate IP 65 in accordance with EN 60 529 (Dust Proof, Water Proof & Weatherproof), Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing,
according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ), Glow wire tested at 960°C in accordance with IEC 60 695-2-11.Type tested as per IEC 61 439- 1. Total Insulated with System. The manufacturer of Polycarbonate feeder post shall submit a copy of CPRI test report of Degree of Ingress Protection IP 65 in accordance with IEC 60529. Each enclosure should have multi no of self-threaded holes. Impact strength should be Ik-08 in accordance with IEC 62262. (The copper Bus Bar will be of 300 Amps rating) as per attached drawing & max input cable size 4Cx120 SQMM. Make Hensel or Similar
method as per site requirement and IS/IE rule. Note: Cable will be laid in HDPE pipe by contractor however cable will be supplied by Railway.
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
fitting and staking of poles within 1km area as per site requirement. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () D- Provision of Ramps to existing FOB for improving divyangjan 596903.15 Below/P accessibility at Tapa & Bhuchchu Railway station. ar
III/1983(latest version) with accessories , junction box etc. including making chase , plastering/clamping etc. as per technical spec. i) 25 mm (medium)
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. i) 1.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. ii) 2.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iii) 4 sq. mm
conduit including connection, testing & commissioning as per tech. spec.. i) Bakelite ceiling rose 3 plate
06 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY
mounted pre fabricated LT distribution Board of approved make as per spec. "i) Incoming MCB DP 40 A ,10 KA, (B/C)=01 No. ii)Out going MCB SP 6/32 A 10 KA,(B/C)=06 No."
mounted pre fabricated LT distribution Board of approved make as per spec. "i) Incoming MCB TPN,
Description:- Earthing with 40mm dia. Earth GI pipe class 'B' , 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including
arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification.
complete as per specification of CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest. Guarantee-05 years from date of commissioning.
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
Description:- Excavation of cable trench by digging 1000 mm deep and then refilling after laying of
providing protective bricks as per drawing and soil and ramming, levelling and repairing the floor to its original condition. i) Trench width 300 mm wide for laying up to 3 cables with 9 protective bricks per meter.
Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
railway track/road as per site required.
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
wall as per tech spec for passing cable. 50 mm dia
with enclosure as per technical specification Square
Foot Description:- Design, manufacture,display, installation of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape.The display sheet shall be of unbreakable
be less than 160 deg. The approved colour text and graphics shall be printed / router cut on
mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site equirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. AMBALA DIVISION-ELECTRICAL/NORTHERN RLY Square
Foot Description:- Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than
calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided.
Description:- "Supply, erection, testing and commissioning of the following double door wall
specification PCEE /NR PCEE/NR/126-Elect/PS/2019/dt 10.12.19 i. Incoming MCCB 4Pole 125 A 35 KA B/C - 1 No. ii. Outgoing MCB 32 A DP 10 KA B/C- 6 Nos. (2 Nos. on each Phase )" S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () E-Provision of Hot Axle Box Detector (HABD) system with provision of 5741691.22 Below/P Electrical supply over Ambala Division ar
Description:- Earthing with 40mm dia. Earth GI pipe class 'B', 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including
arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification.
Description:- Boring & laying of power cables by trenchless method through HDPE pipe along with
mm wall thickness as per IS:4984-95 in the bore for the laying of power cables under the track of road. HDPE pipe is to be supplied by the contractor. The power cables will be supplied by railway.
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
Description:- Excavation of cable trench by digging 1000 mm deep and then refilling after laying of
providing protective bricks as per drawing and soil and ramming, levelling and repairing the floor to its original condition. i) Trench width 300 mm wide for laying up to 3 cables with 9 protective bricks per meter.
Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
involves laying of cable in HDPE pipe. (As per specification)
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
AMBALA DIVISION-ELECTRICAL/NORTHERN RLY
type MS Sheet 16 SWG Die pressed of size 550x450x275 mm deep complete with Aluminium bus bar four nos duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals .( The Bus Bar will be of 500 Amps rating)
10 Description:- Supply, fixing and connection of 16-32A DP MCB with Enclosure.
panel board for panel colour light signalling(CLS) as per RDSO Drawing No.TI/SPC/PSICLS/0020 and approved source for 10 kVA 240 V 3 supply 60 Amp
Enclosure. Suitable as per site work requirement. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () F-Replacement of existing electro mechanical inter locking with panel Above/ interlocking at RTP (Ropar Thermal Power Plant) in SIR-NLDM section of Ambala 443807.58 Below/P division ar
III/1983(latest version) with accessories , junction box etc. including making chase , plastering/clamping etc. as per technical spec. i)25 mm (medium)
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. i) 1.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. ii) 2.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iii) 4.0 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iv) 6.0 sq. mm
conduit including connection, testing & commissioning as per tech. spec.. i) Bakelite batten/angle holder
conduit including connection, testing & commissioning as per tech. spec.. ii) Bakelite ceiling rose 3 plate
8 Description:- supply,fixing,testing & commisioning of 6 amp module switch
9 Description:- supply,fixing,testing & commisioning of 6 amp 5 pin module socket
10 Description:- supply,fixing,testing & commisioning of 16 amp module switch
11 Description:- supply,fixing,testing & commisioning of 16 amp module socket AMBALA DIVISION-ELECTRICAL/NORTHERN RLY
15 Description:- supply,fixing,testing & commisioning of modular socket type (2 module) regulator
16 Description:- supply,fixing,testing & commisioning of 32 Amp moduler switch.
Description:- Supply, erection, testing and commissioning of the following double door wall mounted Pre-fabricated L.T. Distribution Boards of approved make & comprising withs per tech
B/C - 1 No. ii. Outgoing MCB 32 A SP 10 KA B/C- 9 Nos. (3 Nos. on each phase) iii. Outgoing MCB 20 A. SP 10 KA B/C (2 Nos. on each Phase) - 6 Nos iv Outgoing MCB 10A SP 10KA B/C 6 Nos. ( 2 Nos. on each phase)
complete as per specification of CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest. Guarantee-05 years from date of commissioning.
Description:- Supply ,installation ,testing & commissioning of AC MS Exhaust fan 380 mm 900RPM ,
cable size 14/0076" as required suitable for operation on single phase 230 V AC Supply system, earthing, including by grouting MS Nut & bolt of suitable size as per IS:2312 or latest .
driver (70 watts) confirming to CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest specification and site requirement. in details. Guarantee-05 years from date of commissioning.
Description:- Boring & laying of power cables by trenchless method through HDPE pipe along with
mm wall thickness as per IS:4984-95 in the bore for the laying of power cables under the track of road. HDPE pipe is to be supplied by the contractor. The power cables will be supplied by railway.
Description:- LT PTTA with IP-65 protection with canopy Junction box -Design, manufacturing,
36kA & rotary operated mechanism, FP spreader with Aluminium bus bar. As per specification. Note:- All MCCB's should be microprocesser based.
Description:- Earthing with 40mm dia. Earth GI pipe class 'B' , 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including
arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification.
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
26 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY 26 Description:- Excavation of cable trench by digging 1000 mm deep and then refilling after laying of cable as per IS1255:1983 and technical specification on a cushion of sand 100 mm below and providing protective bricks as per drawing and soil and ramming, levelling and repairing the floor to its original condition. i) Trench width 300 mm wide for laying up to 3 cables with 9 protective bricks per meter.
Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
Description:- Supply, installation, testing and commissioning of Ceiling fan 1200 mm sweep having BEE 5 star rating, Motor: Brushless DC (BLDC), power consumtion (W): 25- 30, Winding: Copper,
speed in RPM: 340, conforming to IS:374/1979 and IS:374/2019 or latest, Conformity to Safety Standard IS: 302/1979 connection with twin core PVC insulated flexible copper conductor copper cable of size 14/0.193 mm including earthing.
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
wall as per tech spec for passing cable. (i) 50 mm dia
fitting and staking of poles within 1km area as per site requirement.
each with nut & bolt to hold.
Description:- Supply & erection of 5 mtrs high hot dip galvanized Octagonal pole with top 70 mm
sleeve at the top of pole for following mounting arm bracket 300 mm long suitable foundation and foundation GI nut bolt with washer and smart pack junction box with 6 Amp RCBO, 30mA sensitivity and terminals and as per explanatory note. (i) Single Arm bracket S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () G-New Running Room at PKYN station 3607898.34 Below/P ar
III/1983(latest version) with accessories , junction box etc. including making chase , plastering/clamping etc. as per technical spec. i)25 mm (medium)
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. i) 1.0 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. ii) 1.5 sq. mm
AMBALA DIVISION-ELECTRICAL/NORTHERN RLY Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iii) 2.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iv) 4.0 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. v) 6.0 sq. mm
conduit including connection, testing & commissioning as per tech. spec.. i) Bakelite batten/angle holder
conduit including connection, testing & commissioning as per tech. spec.. ii) Bakelite ceiling rose 3 plate
14 Description:- supply,fixing,testing & commisioning of 6 amp module switch
15 Description:- supply,fixing,testing & commisioning of 6 amp 5 pin module socket
16 Description:- supply,fixing,testing & commisioning of 16 amp module switch
17 Description:- supply,fixing,testing & commisioning of 16 amp module socket
18 Description:- supply,fixing,testing & commisioning of modular socket type (2 module) regulator
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
Description:- Excavation of cable trench by digging 1000 mm deep and then refilling after laying of
providing protective bricks as per drawing and soil and ramming, levelling and repairing the floor to its original condition. i) Trench width 300 mm wide for laying up to 3 cables with 9 protective bricks per meter.
AMBALA DIVISION-ELECTRICAL/NORTHERN RLY Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
railway track/road as per site required.
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
complete as per specification of CEE/NR/121-Elect/PS/2018 dt 28/06/18 or latest. Guarantee-05 years from date of commissioning.
Description:- Supply ,installation ,testing & commissioning of AC MS Exhaust fan 380 mm 900RPM ,
cable size 14/0076" as required suitable for operation on single phase 230 V AC Supply system, earthing, including by grouting MS Nut & bolt of suitable size as per IS:2312 or latest .
Description:- Supply ,istallation ,testing & commissioning of AC MS Exhaust fan 450 mm 900RPM
operation on single phase 230 V AC Supply system, earthing, including by grouting MS Nut & bolt of suitable size as per IS:2312 or latest .
Description:- Supply, installation, testing and commissioning of Ceiling fan 1200 mm sweep having BEE 5 star rating, Motor: Brushless DC (BLDC), power consumtion (W): 25- 30, Winding: Copper,
speed in RPM: 340, conforming to IS:374/1979 and IS:374/2019 or latest, Conformity to Safety Standard IS: 302/1979 connection with twin core PVC insulated flexible copper conductor copper cable of size 14/0.193 mm including earthing.
suitable for low cabin room make Khaitan , BAJAJ,USHA,
mounted pre fabricated LT distribution Board of approved make as per spec. i) Incoming MCB DP 40 A ,10 KA, (B/C)=01 No.ii)Out going MCB SP 6/32 A 10 KA,(B/C)=06 No.
mounted pre fabricated LT distribution Board of approved make as per spec. ii) Incoming MCB TPN,
Description:- Supply, erection, testing and commissioning of the following double door wall
specification PCEE /NR PCEE/NR/126-Elect/PS/2019/dt 10.12.19 i. Incoming MCCB 4Pole 125 A 35 KA B/C - 1 No. ii. Outgoing MCB 32 A DP 10 KA B/C- 6 Nos. (2 Nos. on each Phase )
Make: Bajaj/Philips/Havells/Crompton/Panasonic or equivalent.
lamp/LED name sign board with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc.
240V,50Hz complete with all accessories as per IS, Make: Bajaj/Philips/Havells/Crompton/Panasonic or equivalent.
35 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY Description:- supply,fixing,,testing and commisioning of down lighter 12 watt LED Cool day light as per specifation CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest specification and site requirement. Guarantee five years from date of commissioning
Description:- Supply Installation Testing & commissioning of Decorative LED Mirror Light Fitting 10-
confirming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-III attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-IV attached or latest. Square
Foot Description:- Design, manufacture,display, installation of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape.The display sheet shall be of unbreakable
monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site equirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Square
Foot Description:- Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than
calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided.
complete with 4 modular plate, 25 A MCB, starter, plug & socket for AC. Make Legrand, Havells, Crabtree, Wipro, Cona ,anchor or equivalent as per IS & IE rules.
Description:- Earthing with 40mm dia. Earth GI pipe class 'B' , 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including
arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification.
Description:- Earthing with 600x600x3mm thick copper plate earth electrode as per IS 3043(Latest
with hinged cover plate of cast iron with locking arrangement (Approx.size 600x600mm) on top, watering pipe, connections from earth plate to top with 40x6mm copper strip in 50mm dia GI pipe class B provision of earth plate as per drawing and tech. spec.
in ground/recessing in floor from earth electrode strip to neutral of transformer/alternator as per drawing and technical specification including supply of material.
Description:- Supply, installation, testing and commissioning of DB Panel having 1 No. 400 A MCCB
100A MCCB FP & 4 Nos. 63A MCB FP as outgoing with all associate accessories as per technical specification . (i) Erection
45 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY 45 Description:- Supply, installation, testing and commissioning of DB Panel having 1 No. 400 A MCCB FP Microprocessor based having LSIG protection as incoming and 2 Nos. 250 Amp. MCCB FP, 2 Nos. 100A MCCB FP & 4 Nos. 63A MCB FP as outgoing with all associate accessories as per technical specification . (ii) Supply
wall as per tech spec for passing cable. (i) 100 mm dia
Description:- Supply & erection of 7 mtrs high hot dip galvanized Octagonal pole with top 70 mm around face bottom 130 mm thick steel base plate size 200X200X12mm complete with appropriate
light fittings and M20 foundation including casting,muffing,with cement concrete foundation(1:2:4) painting,earthing & foundation GI nut bolt with washer and smart pack junction box with 6 Amp DP RCBO with 30 mAmp senstivity and terminals and as per explanatory note. (i) Single/double Arm bracket
per CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest specification and site requirement. in details. Guarantee-05 years from date of commissioning
with RCC Trench cover of the following size with providing angle iron in trench for cable laying with support and proper dressing there in trench. Size:50 mtrs x 0.6 mtrs X 1 meter.
Description:- Supply, fixing, testing and commissioning of low depth sleek type complete LED
CEE/NR/121-Elect/PS/2018 dt 28/06/18 or latest specification.Guarantee five years from date of commissioning.
as per IS & IE rules and site requirement prior approval of sample. Make-Adhunik, Twinkle Light or equivalent as per drawing.
leakage, overload and short circuit protection as per spec
type with control valve, pressure gauge and flexible hose with nozzle all as specified and as directed.
galvanized cable tray of under mentioned sizes with all accessories such as corner, bend tie rods etc as per site requirement and to the satisfaction of railway authority. (i) 50x150x50 mm
per IEC 60947-2). Make: Schneider, Legrand or L&T or similar.
wall as per tech spec for passing cable. (i) 50 mm dia
rating, 5 HP/3.7 KW, 350 V -420 v, 3 phase copper winding, 78 Meter head, 160 LPM, confirming to latest spec & ISI marked.
v, 3 phase copper winding, 78 Meter head, 160 LPM, confirming to latest spec & ISI marked.
59 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY Description:- Fully Automatic Star-Delta smart controller suitable for 6 HP pump-motor 3 phase 415VAC, 4-22A, Compatible with model: MU-G6S of L&T make, inbuilt anti theft protection, dry run, locked rotor & short circuit protection, voltage and current based protection, hour based and real time clock based timer with line voltage, phase current, power factor, energy metering, total run time of pump. Complete operation (Remote on/off) through SMS or LTLK connect mobile App or IVRS in Hindi & English language, micro controller based technology., Make: L&T, Havells, Seimens, Schneider, C&S or similar.
submersible cable 3 core flat (1x3x6 sq mm)
61 Description:- Supply,fixing & commissioning of GI Bend one side flanged 1.5".
with hole size 5/8"
63 Description:- Supply,fixing & commissioning of NRV G.Metal 1.5".
64 Description:- Supply,fixing & commissioning of Sluce valve G.Metal 1.5".
65 Description:- Supply,fixing & commissioning of MS Clamp1.5".
66 Description:- Supply,fixing & commissioning of Nut bolt 1.5"x3/8" with washer.
Description:- Fabrication,supply , fixing and commissioning of 38mm dia "C" class G.I. Pipe lengths
76mm/38mm" dia 5/8" thickness with four drilled holes of 1/2" dia and and 75/38 mm dia flange with
lowering of motor also to be either supplied by Rly or Contractor) S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () H-Repair and rewinding of 1 Nos. 250 kva Transformer (BTI) 474199.60 Below/P ar
01 Description:- New copper coil for rewinding of transformer
03 Description:- Insulation, Paint, Misc. Items for 250 KVA Transformer
etc. complete job. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () I-Repair and rewinding of 1 Nos. 1000 kva Transformer (BTI) 827100.60 Below/P ar
01 Description:- New copper coil for rewinding of transformer
03 Description:- Insulation, Paint, Misc. Items for 1000 KVA Transformer
unloading etc. complete job. AMBALA DIVISION-ELECTRICAL/NORTHERN RLY S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () J-Oil Filteration at UMB/RV/Power depot, NLDM/Power depot, 112697.59 Below/P UMB/Colony/Power depot, BTI/Power depot ar
per IE rule. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () K-Provision of Bio-toilet testing lab at C&W Depot, CDG. 478368.14 Below/P ar
III/1983(latest version) with accessories , junction box etc. including making chase , plastering/clamping etc. as per technical spec. i)25 mm (medium)
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. i) 1.0 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. ii) 1.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iii) 2.5 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. iv) 4.0 sq. mm
Description:- Supply, laying, fixing, testing and commisioning of following sizes FRLS PVC insulated
make Finolex, Havells, Polycab, KEI or equivalent in the existing (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note. v) 6 sq. mm
conduit including connection, testing & commissioning as per tech. spec.. i) Bakelite batten/angle holder
conduit including connection, testing & commissioning as per tech. spec.. ii) Bakelite ceiling rose 3 plate
11 AMBALA DIVISION-ELECTRICAL/NORTHERN RLY 11 Description:- supply,fixing,testing & commisioning of 3 module metal GI box with 3 module cover plate
12 Description:- supply,fixing,testing & commisioning of 6 amp module switch
13 Description:- supply,fixing,testing & commisioning of 6 amp 5 pin module socket
14 Description:- supply,fixing,testing & commisioning of 16 amp module switch
15 Description:- supply,fixing,testing & commisioning of 16 amp module socket
Description:- Laying of 2/3/4 core 16/25/35/50/75/95 /120/240/400 sqmm LT UG/XLPE in
will be supplied by the Railways free of cost. However, Contractor has to make own arrangement for shifting the cable to site from the Elect maintenance Depot store.
Description:- Excavation of cable trench by digging 1000 mm deep and then refilling after laying of
providing protective bricks as per drawing and soil and ramming, levelling and repairing the floor to its original condition. i) Trench width 300 mm wide for laying up to 3 cables with 9 protective bricks per meter.
Description:- Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical
drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. i) Trench width 300 mm wide for laying up to
complete as per specification of CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest. Guarantee-05 years from date of commissioning.
Description:- Supply ,installation ,testing & commissioning of AC MS Exhaust fan 380 mm 900RPM ,
cable size 14/0076" as required suitable for operation on single phase 230 V AC Supply system, earthing, including by grouting MS Nut & bolt of suitable size as per IS:2312 or latest .
Description:- Supply, installation, testing and commissioning of Ceiling fan 1200 mm sweep having BEE 5 star rating, Motor: Brushless DC, power consumtion (W): 25- 30, Winding: Copper, Speed
in RPM: 340, conforming to IS:374/1979 and IS:374/2019 or latest, Conformity to Safety Standard IS: 302/1979 connection with twin core PVC insulated flexible copper conductor copper cable of size 14/0.193 mm including earthing.
mounted pre fabricated LT distribution Board of approved make as per spec.(i) i) Incoming MCB TPN,
per specifation CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest specification and site requirement. Guarantee five years from date of commissioning
Description:- Design, supply, installation, testing & commissioning of weather proof outdoor feeder pillar (MCCB incoming & MCCB outgoing) comprising with the following MCCB's fixed in it of make
IS 8623:2008 or latest with digital measuring instrument & bus bar arrangement and confirming to PCEE/NR spec. no. 126-Elect./PS/2019 or latest and as per IS, IR rules and site requirement. 4P MCCB 400A 36kA with adjustable thermal & fixed magnetic release = 01 No. (Incoming) 4P MCCB 125A 36kA with adjustable thermal & fixed magnetic release = 04 Nos. (outgoing)
railway track/road as per site required. AMBALA DIVISION-ELECTRICAL/NORTHERN RLY
pitched/stone/brick/ paved surface, road/crossing/platform etc and restoring the surface to its original condition.
complete with 4 modular plate, 25 A MCB, starter, plug & socket for AC. Make Legrand, Havells, Crabtree, Wipro, Cona ,anchor or equivalent as per IS & IE rules.
Description:- Earthing with 40mm dia. Earth GI pipe class 'B' , 3 meter long, earth electrode as earth per IS:3043 (latest version) to achieve earth resistances less than 5ohms including
arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch earth gear/pole as per technical Specification/I.E. Rule.
per technical specification.
ALONG WITH 12 VOLT 180 AH LEAD ACID TUBULAR BATTERY 2 NOS WITH BOX STAND.
Description:- Installation, testing and commissioning of 1.5 Ton/2 Ton capacity window AC unit alongwith replacement if required including supply and fixing of suitable size wooden frame
nearest drainage point. Proper sealing to be done by providing low density foam strip between wooden frame / wall and the AC unit as per technical scope of work. (Note : Air conditioner will be supplied by the Railways)
wall as per tech spec for passing cable.(i) 50 mm dia
clamps each with nut & bolt to hold.
driver (70 watts) confirming to CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest specification and site requirement. in details. Guarantee-05 years from date of commissioning.
Description:- Supply, fixing, testing and commissioning of low depth sleek type complete LED
CEE/NR/121-Elect/PS/2019(Rev-04) dt 04/11/2019 or latest specification.Guarantee five years from date of commissioning.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDOCT31_1.pdf
ATTACHMENT
Annexure A
ATTACHMENT
AnnexureXXIV.pdf
ATTACHMENT
AnnexureXXIVA_1.pdf
ATTACHMENT
LatestCEESpec_compressed1.pdf
ATTACHMENT
GCCwithcorrectionsliplatest_compressed.pdf General conditions of contract
ATTACHMENT
7mtrpoledrawing.pdf
ATTACHMENT
Polycarbonatefeederpost_0012.pdf
ATTACHMENT
Annexure-APartnershipRetirementEmployes.pdf
ATTACHMENT
GCCwithcorrectionsliplatest_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid