| 1 | L1₹21.6 LAccepted-AOC WARD NO 1 CHANDAN PURA ATER ROAD BHIND MADHYA PRADESH 477 001 | BHIND | BHIND | MADHYA PRADESH | 477001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.2 L+₹4.5 L (20.6%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹28.2 L+₹6.5 L (29.9%)Rejected-AOC 37 B SAHEB KRUPA SOC JIVAN CHETAN SCHOOL SAMA ROAD VADODARA GUJARAT PIN 390 008 | VADODARA | GUJARAT | 390008 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹28.2 L+₹6.5 L (29.9%)Rejected-AOC SHAMAL BECHAR S CHAWL SIDHANATH ROAD B H KHANDERAO MARKET VADODARA 390 001 GUJARAT | VADODARA | VADODARA | GUJARAT | 390001 | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹28.5 L+₹6.8 L (31.4%)Rejected-AOC 22 JANKALYAN SOCIETY NAVJIVAN AJWA ROAD BARODA 390 019 | BARODA | VADODARA | GUJARAT | 390019 | L5 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
26 Jun 2023, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2023_MES_601258_1
8744
Open Tender
Civil Works
Item Rate
270 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹54,000
Yes
9 Aug 2023
5 Jun 2023
27 Jun 2023
5 Jun 2023
26 Jun 2023
19 Jun 2023
6 Jun 2023 - 19 Jun 2023
Amount
Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for drain
M & L for Cement concrete type B1 1:2:4 (20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges.
Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc.
M&L for Rendering in two layer on fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC as per manufacturer's instructions of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately).
Supply only liquid water proofing compound all as specified and directed.
M & L for preparing new plastered surfaces of wall and applying two coats cement base paint over a coat of alkali resistant primer on external wall.
Disconnecting existing tanks, exc. 250 and n. exc 500 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
Disconnecting existing tanks, exc. 500 and n. exc 1000 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
S&F in repairs including disconnecting tanks, 500 ltrs rotational moulded triple layered, polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as directed.
All as per iem No 9 but 1000 ltrs capacity.
Taking up or down steel tubing and connections, 20mm bore including cleaning for refixing or removal to store
Taking up or down steel tubing and connections, 25mm bore including cleaning for refixing or removal to store
Refixing 20mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Refixing 25mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
S&F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S&F 25mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S & F 20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S & F 25mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
M&L for complete removal of existing water proofing treatment APP membrane and cement plaster and cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
M&L for complete removal of existing water proofing treatment including plaster and concrete padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
M&L for complete removal of existing water proofing treatment including PCC tiles, plaster and concrete padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
M&L for 50 mm avg thick PCC padding in cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggr mixed with liquid WPC as per manufacturer's instructions of cement finished surface even and fair without using extra cement for laying of WPT all as specified and directed. (WPC will be measured and paid separately).
M&L 10mm thick rendering on roof in CM 1:3 mixed with liquid WPC as per manufacturer's instructions of cement for finished even and smooth without using extra cement over PCC surface for laying APP membrane on roof (WPC will be measured and paid separately).
M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying actetic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimum 3.50 Kg/Sqm 3 mm thick (minimum) with minimum 75 mm side overlaps and minimum 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge
M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying actetic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimum 3.50 Kg/Sqm 3 mm thick (minimum) with minimum 75 mm side overlaps and minimum 100 mm end overlaps complete all as specified and directed by Engr-In-Charge
M&L for water Proofing treatment to roof slabs by applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.25 Ltrs/Sqm, and laying self adhesive water proofing membrane 1.5 mm thick with minimum 75 mm side overlaps and minimum 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over membrane complete all as specified and directed by Engr-In-Charge
M & L for brushing with neat cement slurry @ 3Kg/Sqm
M & L for Cement concrete tiles 25cm x 25cm x 22mm thick, m a c h i n e pressed; set jointed and pointed in neat cement slurry with liquid WPC as per manufacturer's instructions in floors/roof top laid over and including 20 mm thick cement screed in CM 1:6 complete all as specified and directed (WPC will be measured and paid separately).
Cutting grooves in brick parapet wall, 75mm wide and 65mm deep and shaping horizontal face of groove for sealing APP membrane in brick parapet wall with cement mortar 1:3 complete all as specified and directed.
S & F 25mm thick pre-formed filler for expansion/crumple joints of roof slabs
Supply and fix Plain 0.71mm thick, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)
Taking down PVC/CI pipe of any pattern size including all fittings etc.
S&F in repairs 110mm dia PVC SWR pipe single socketed in any length with rubber ring joints fixed to walls
S & F in repairs 110mm dia PVC SWR bend with oval access door
S & F in repairs 110mm dia PVC SWR bend without oval access door
S&F in repairs 25mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc,
M & L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6
M & L 100mm thick plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base, water tank staging etc. complete, all as specified & directed.
M & L for Treatment of roof cracks in existing roof surface by cutting out portion along the cracks with mechanical equipment inti 'V' shape , cleaning the cut out portion with compressed air to remove all foreign materials like dust, dirt, aggregates etc,apply the crack seal compound over the cracks as per manufacturers instructions and as specified and as directed by Engr- in- charge..
Dagli Engineers
Pratik Enterprise
M/s. RAMESH NARHARI VALEKAR
Aditya Construction
OM Engineering
Gayatri Associates
Harsh Infrastructure
City Light
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .