Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L1 | Accepted-AOC Accepted - AOC | |
| 2 | L2₹39.6 L+₹5.3 L (15.6%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L2 | Rejected-AOC Rejected - AOC | |
| 3 | L3₹39.7 L+₹5.4 L (15.9%)Rejected-AOC | L3 | Rejected-AOC Rejected - AOC | |
| 4 | L4₹40.8 L+₹6.5 L (19.0%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L4 | Rejected-AOC Rejected - AOC |
Tender Value
₹45 L
EMD Value
₹91,800
Closing Date
19 May 2020, 6:00 pmClosed
GE DEHRADUN
GE DEHRADUN, MALL ROAD, GARHI CANTT
Repair/ Servicing / Maintenance of DG Sets, Panels and allied external water supply works installed under AGE E/M-I of GE Dehradun
2020_MES_339664_1
8191/A/E8
Open Tender
Civil Works
Item Rate
240 days
GE DEHRADUN
Class D Cat a(ii) and b(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹91,800
Yes
9 Sept 2020
20 Apr 2020
21 May 2020
20 Apr 2020
19 May 2020
5 May 2020
Amount
M&L for excavation in trenches in any type of soil not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep in any type of soil including cutting in slopes etc for laying of pipe line including getting out, complete all as specified and directed.
M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers in soft / loose soil not exceeding 25 cm in each layer complete all as specified and directed by Engineer-in-Charge.
M&L for removal of excavated material to a distance up to 50 metre from starting point and depositing where directed at level not exceeding 1.5 metre above as directed by Engineer-in-Charge.
M&L for dismantling electrically and taking down unserviceable fully automatic starter any type dry/ ATS type, from base frame and transporting to workshop for cleaning and refixing the serviceable parts back after repair and replacement of U/s parts for the 50.0 HP to 80.0 HP capacity size.(Note: Spare parts required for replacement shall be measured & paid for separately under respective item).
Supply only following spare parts and shall be replaced for starter under item No 4& 5 here in above (Parts of starter shall be as per the make of starter.)
Fixed power copper contacts suitable for 60 HP star delta starter.
Fixed power copper contacts suitable for 75 HP star delta starter.
Moving power copper contacts suitable for 60 HP star delta starter.
Moving power copper contacts suitable for 75 HP star delta starter.
Auxiliary switch type -01 with 1 No-1 NC suitable for 60/80 HP star delta starter.
RZ timer with coil & time delay range 3-12 seconds suitable for 60/80 HP starter.
Mini motor Protection relay protections for Thermal overload, Earth fault, Locked rotor, single phasing, current unbalance, phase sequence reversal and under current. Make L&T
S&F in repair fully automatic Star Delta starters with D range Contractor, LR1D OLR & Electronic Star Delta Timer wall mounted type with start/stop push bottom toper, with enclosure for 75 HP capacity complete all as specified and directed. Make:- C&S/BCH/L&T.
S&F in repair fully automatic Star Delta starters with D range Contractor, LR1D OLR & Electronic Star Delta Timer wall mounted type with start/stop push bottom toper, with enclosure for 150 HP capacity complete all as specified and directed. Make:- C&S/BCH/L&T.
Dismantling and taking out the existing corroded / scaled GI pipe / PPR/ PALP pipe with fittings connections from trenches, walls, ceiling or floor and removal from site or disposed off for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule "A"
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, Laying, fixing & testing galvanised iron water tubing 'medium grade; ISI marked with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule "A"
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
M&L for structural steel framed work as in valve pit covers of angle or other section with , rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, to be prepared for hanging with and including either hooks and hinges or steel hanging fittings and fixing including removing unserviceable cover complete (structural steel conform to Fe 410w (Gde & 250) quality 'A') all as specified and directed.
Dismantling/taking out defective Gun metal gate valve and S&F for Gun metal gate valve with iron wheel head by screwing/cutting of existing pipe lines for the following size complete all as specifed and directed. Make: Sant / Seiko
20 mm bore
25 mm bore
40 mm bore
50 mm bore
M&L for construction of brick masonary valve pit of size 60cm x 60cm x 60cm (internal demension) complete with 50x50x6mm angle iron frame, with 3.15mm thick MS cover sheet with hinges, sliding type lifting handle of MS bar 12 mm dia with locking arrangement heavy duty duly welded with angle iron frame complete including necessary excavation and earth work, PCC (1:2:4,) type B-0 (using 12.5mm graded agregate) as in coping, 15mm thick internal plaster in CM (1:4) 75mm thick PCC (1:4:8), type D-2 (using 40mm graded agregate)lean concrete over 75mm thick hard core over rammed earth, flooring shall be 40mm thick PCC (1:2:4) type B-1(using 20mm graded agregate) all steel surfaces shall be painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specifed and shown on drawing No TD/EM/12 complete all as specfied and directed.
M&L for construction of brick masonary valve pit of size 90cm x 90cm x 90cm (internal demension) complete with 50x50x6mm angle iron frame, with 3.15mm thick MS cover sheet with hinges, sliding type lifting handle of MS bar 12 mm dia with locking arrangement heavy duty duly welded with angle iron frame complete including necessary excavation and earth work, PCC (1:2:4,) type B-0 (using 12.5mm graded agregate) as in coping, 15mm thick internal plaster in CM (1:4) 75mm thick PCC (1:4:8), type D-2 (using 40mm graded agregate)lean concrete over 75mm thick hard core over rammed earth, flooring shall be 40mm thick PCC (1:2:4) type B-1(using 20mm graded agregate) all steel surfaces shall be painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specifed and shown on drawing No TD/EM/12 complete all as specfied and directed.
M&L for construction of brick masonary valve pit of size 120cm x 120cm x 90cm (internal demension) complete with 50x50x6mm angle iron frame, with 3.15mm thick MS cover sheet with hinges, sliding type lifting handle of MS bar 12 mm dia with locking arrangement heavy duty duly welded with angle iron frame complete including necessary excavation and earth work, PCC (1:2:4,) type B-0 (using 12.5mm graded agregate) as in coping, 15mm thick internal plaster in CM (1:4) 75mm thick PCC (1:4:8), type D-2 (using 40mm graded agregate)lean concrete over 75mm thick hard core over rammed earth, flooring shall be 40mm thick PCC (1:2:4) type B-1(using 20mm graded agregate) all steel surfaces shall be painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specifed and shown on drawing No TD/EM/12 complete all as specfied and directed.
S&F in repair CI sluice valve both end flanged dully drilled for both ends with stainless steel spindle and nuts stuffing box etc type PN - 1.6, ISI marked of following sizes:-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore.
S&F in repair CI Non return valve flanged ends as per IS-5312 complete with Nuts/Bolts and washers and rubber packing etc for the following sizes:-
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F in repair CI foot valve, One end flanged and strainer to the other side for the following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair water pressure gauge glycerin filled of size 100 mm 0-7 kg/cm2 complete all as specified & directed.
Material and labour for restoration of water supply by identifying and rectifying the water supply leakage, repair work, at any location, in any type of leakage in 15mm/ 20mm/25mm pipes of GI/ MS with any type of joints i.e. flanged, socketed,welding joint, including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site and as directed. (Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item).
Material and labour for restoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage in 40mm / 50mm/ 80mm/pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed. (Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item)
Material and labour for restoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage in 100mm / 150mm pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed. (Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item).
Material and labour for resoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage in 200mm / 250mm pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed. Note : (i) Any earth work required for repair shall be measured and paid for separately.(ii) Any material required for leak repair deemed to be included in the above quoted rate.(iii) Any length of pipe required shall be paid sepertately under relevant item.
Material and labour for resoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage in 300mm pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed. (Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item).
Disconnecting and taking down unserviceable electric motor of capacity 125 HP 1450 RPM 3 Phase from base frame and shifting to workshop for rewinding, opening complete, taking out Rotor assembly from stator carefully and cutting/cleaning burnt winding wire from stator, carefully repairs to damaged slots including Rewinding of stator with super enameled copper wire of gauge same as original & Varnishing the same, drying tapping with cotton tapes, all electrical connections should be soldered properly, reassembling reshifting & reinstallation at site inclduing testing at full load complete all as specifed & directed.
All as per item No. 24.00 here in above but 75 HP 1480 RPM 3 Phase complete all as specified & directed.
All as per item No. 24.00 here in above but 40 HP 1480 RPM 3 Phase complete all as specified & directed.
All as per item No. 24.00 here in above but 20 HP 1480 RPM 3 Phase complete all as specified & directed.
All as per item No. 24.00 here in above but 15 HP 1480 RPM 3 Phase complete all as specified & directed.
All as per item No. 24.00 here in above but 12.5 HP 1480 RPM 3 Phase complete all as specified & directed.
All as per item No. 24.00 here in above but 1 to 3 HP 1480 RPM complete all as specified & directed.
Taking down pumping set from base frame including disconnection from coupling 40 HP, installed at pump house and shifting to workshop for repair, opening dismantling and overhauling complete parts, cleaning all parts by Kerosene oil neatly and Supply and fixing new rotary assembly complete with CI impellers ,SS shaft , sleeves , bushings , bearing housing, neck ring, center ring, keys for shaft, keys for coupling, gland packing, any nut bolt washer required or any other spare of standard assembly set of OEM, incl necessary welding, machining, grinding work if required at the time of refitting of assembly into pump casing, and refixing of the on base plate with proper alignment with motor and testing on full discharge complete all as specified and directed . Note:- (i) The item rate shall be deemed to be inclusive of required spares, any machining work, transporting of pump set to and fro workshop if required and back after repair. (ii) Contractor shall ensure water pipe lines sealed by blocking with dead flange for the repair period if required).
All as per item No. 31.00 here in above but 50 HP complete all as specified & directed.
All as per item No. 31.00 here in above but 75 HP complete all as specified & directed.
All as per item No. 31.00 here in above but 100 HP complete all as specified & directed.
All as per item No. 31.00 here in above but 125 HP complete all as specified & directed.
M&L for MS clamps fabricated from MS flat not less than 4mm thick fixed to water supply pipes to stop the leakage with rubber packing, nut , bolts washers, cutting, welding etc as required at site and all as directed.
S&F in replacement cast iron 'D' joint set for 200 mm bore CI/DI pipe complete of two flanged collar one no sleeve two nos rubber 'O' ring and nut bolts washers of suitable size complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the pipe shall be measured and paid separately)
S&F in replacement cast iron 'D' joint set for 150 mm bore CI/DI pipe complete of two flanged collar one no sleeve two nos rubber 'O' ring and nut bolts washers of suitable size complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the pipe shall be measured and paid separately)
S&F in replacement cast iron 'D' joint set for 100 mm bore CI/DI pipe complete of two flanged collar one no sleeve two nos rubber 'O' ring and nut bolts washers of suitable size complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the pipe shall be measured and paid separately)
S&F in replacement cast iron 'D' joint set for 80 mm bore CI/DI pipe complete of two flanged collar one no sleeve two nos rubber 'O' ring and nut bolts washers of suitable size complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the pipe shall be measured and paid separately)
Taking up or down cast iron pipe of tyton joint type from trenches including dismentling tyton joints type & removing for disposal for the pipes of 150 mm bore complete all as specified and directed. (Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule "A")
All as per item No 42.00 here in above but 200 mm bore.
Supplying and laying in trenches CI spun pipe 150 mm bore, centrifugally cast, with spigot and socket end, class LA ISI marked of the following bores complete all as specified and directed. (Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule "A"). Make : Electrosteel/TATA
All as per item No 139 above but 200 mm bore.
M&L for tyton rubber gasket joints for 150 mm bore complete all as specified and directed
M&L for tyton rubber gasket joints for 200 mm bore complete all as specified and directed
Material and labour for servicing of DG set of any make of following capacity, by cleaning, servicing, oiling and greasing of moving parts, checking the serviceability of self starter, alternator, AVR for proper voltage out put, batteries voltage & electrolyte be checked & added upto top level, functunability of safety devices, all nut - bolts of Engine and alternator, proper tension of fan belts, check coolant level and top up if necessary. Ensuring leak proof of all type i.e. hose for water, pipe line of fuel and lub oil etc., Checking of air cleaner element & cleaning with dry compressed air (60 psi pressure.), replacement of lubricating oil (Cost of lubricating oil shall be measured and paid separately) including 'Material and labour for replacement of Air filter elements set, Cleaning of oil bath type filters and replacement of oil of oil bath filter, Lubricating oil filters element complete set, Fuel filters element, By pass filter, Corrosion resistor plate, Fan belts complete as specified and directed. (Note : servicing will be done through authorised dealer only and a certificate to this effect will be submitted from authorised dealer to the department.)
NOTES: (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The cost of servicing of DG set are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, studs etc and parts mentioned in the item above.. (ii) Make of DG set be one of the make mentioned in the item. (iii) Spare parts to be replaced shall be suitable for the same make and model of engine as installed at site and serviced. (iv) Cost of lubricating oil shall be measured and paid separately. (v) Cost of Spare parts to be replaced shall be measured and paid separately under item No.142 here in after.
225 KVA 3 phase 50 Hz, Make : Kirloskar/ Cummins
100 KVA to 160 KVA 3 phase 50 HZ, Make : Mahindra/Cuminns/ Kirloskar/ Greaves.
62.5 KVA to 75 KVA 3 phase 50 HZ, Make : Cuminns/ Kirloskar/ Greaves.
Supply only of the following new parts suitable for DG Sets repaired under Schedule `A' item No 47.00 to 47.04 above :- (Note :- Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 47 to 47.04.
Water hose pipe set with clamp for 225 KVA capacity of DG set.
Water hose pipe set with clampfor 100 KVA to 160 KVA capacity of DG set.
Water hose pipe set with clamp for 62.5 KVA to 75 KVA capacity of DG set.
Lubricating oil pipe set with coupling for 225 KVA capacity of DG set.
Lubricating oil pipe set with coupling for 100 to 160 KVA capacity of DG set.
Lubricating oil pipe set with coupling for 62.5 KVA to 75 KVAcapacity of DG set.
Fuel pipe set with coupling for 225 KVA capacity of DG set.
Fuel oil pipe set with coupling for 100 KVA to 160 KVA capacity of DG set.
Fuel oil pipe set with coupling for 62.5 KVA to 75 KVA capacity of DG set.
Oil temperature gauge
Water temperature gauge
Oil pressure gauge 0 to 7 kg/cm2
Hours meter
Ampere meter.0-300A
Shut down valve suitable for 62. 5KVA to 225 KVA capacity of DG sets as per existing shape and size.
Disconnecting, and taking out carefully old unserviceable AVR unit and supply , fixing, connecting and testing AVR unit suitable for DG set of 62.5 KVA capacity.and testing for regulated voltage of 415 volts complete all as specified and directed. Make Kirloskar/National/Universal
Supply only lubrication oil SAE-40 ( 20 W- 40 grade) of Make: IOC/ HINDUSTAN PETROLEUM/ BPCL/ CASTROL as approved by GE.
Disconnecting and taking out the radiator of following capacity of DG sets and carrying out to work shop, strip opening complete radiator assembly, cleaning of tubes using de-scaling solution, including soldering / gas welding of leakage of tubes. Cutting the rusted portion of in-let or out-let tubes and providing new MS water tubes & jointing with gas welding and assembling the complete radiator including replacement of gasket, nut bolts, and testing for making it leak proof, oiling/servicing of water cooling assembly, replacing unserviceable parts, re-assembling and fixing the same in position and testing the system on actual load. complete all as specified and directed by Engineer-in-Charge.
(a) 225 KVA 3 phase 50Hz, Make : Kirloskar
(b) 100 KVA to 160 KVA 3 phase 50 HZ, Make : Greaves.
(c) 62.5 KVA to 75 KVA 3 phase 50 HZ, Make: Kirloskar
NOTES :- (i) Repairs/servicing/reassembling and testing of water cooling assembly shall be carried out on actual load. (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, screws/gaskets/ packing etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro upto Work shop/service centre.
Disconnecting and taking out defective battery lead and supplying, fixing, connecting and testing battery lead (Heavy duty) PVC insulated with multi strand copper conductor single core of size 25 Sqmm for 2 metre length including one side fixed with brass/ copper eye hole lugs clamp and other side fixed with brass battery terminal of heavy duty complete all as specified and directed.
Disconnecting and taking down old unserviceable self starter, 12 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the Following parts :- (a) Armature – 01 No (b) Solenoid switch – 01 No. (c) Field coils – 01 No. (d) Commutator – 01 No. (e) Carbon brush – 02 Nos. (f) Bendex assembly – 01 No (g)Tension sleeve=01no (h) Gear assembly-01 no
All as per item No 53.00 here in above but 24 Volt DC
M & L for Cleaning of MS fuel tank of DG sets of various capacity by collecting the fuel in cleaned barrels and removing sludge deposited/ accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil, replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
Dismantling and taking out old unserviceable Dynamo assembly of 62.5 KVA to 225 KVA capacity of DG set for repair and replacement of defective parts like as Carbon brush, Bearing No. 6302 and rewinding to armature with suitable gauge of copper wire, sleeve, glass paper and Varnish, soldering to commutator assembly, reassembling & fixing the same in position and testing the dynamo assembly all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement the following spares/parts/ components of AMF Panels .
Power Contactor, LCIF 225A,,3 pole, coil voltage 415 / 440 Volts, 50 Hz with 2 NO + 2 NC auxiliary contacts, having current rating (AC3) of 200 Amps at 415 volts as per C & S Electric/GE/BCH.
Power Contactor, 3 pole having current rating (AC3) of 500 Amps at 415 Volts and as per cat part No LC1F 400A of C & S Electric or equivalent of make Siemens / L&T / BCH/GE.
Pla relay 24 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -24D of pla make or equivalent of Eagle man.
Bimetal overload relay type MNX with relay range 24 – 40 Amps suitable for 3 phase 415 volts, AC supply (Make : L&T cat No. SS94145OOFO or equivalent of BCH )
Electronic DC timer suitable for 12/24 Volts DC supply, for 0-60 seconds. (on delay). (Make : L&T / PIC / Aditya Electronic)
Under voltage relay suitable for 3 phase 415 volts, AC supply (Make : PIC / Aditya Electronic )
Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply. (Make : PIC / Aditya Electronic)
Indicating lamps neon type with holder for 12 / 24 volts DC supply (RYB) (Make : L&T/BCH or equivalent make as approved by the GE )
Electronic timer, suitable of 240 / 415 Volts, 50 Hz, AC supply, for 0-180 seconds (ON delay). (Make : L&T / PIC / Aditya Electronic)
Supply and fix iron hinges suitable for DG set doors Make : Kirloskar or equivalent
S&F in repair unserviceable canopy door lock of suitable size Make : As per sample
Dismantiling existing unserviceable 100 LPD/ 200 LPD solar water heating system and M&L for cleaning & servicing by cleaning complete tubes and internally , de-scaling, cleaning of all effected parts, removing any type of chocking of Solar Collector or tube, repairing any type leakage from Gasket, Rubber Washer after Cold Water inlet and before hot water outlet of Solar Water Heater with cleaning agent and re-fixing in its original position after necessary repairs and replacement of unserviceable spares all as specified and directed. NOTES :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, screws/gaskets/ packing etc.
All as per Srl Item No 60.00 above but 300 LPD / 500 LPD
S &F in repair hot water pipe line 20 mm dia (heavy grade) duly insulated with glass wool 50mm and aluminum cladding complete all as specified and directed.
S & F in repair 15 mm dia bore bib taps, chromium plated, screwed down, high pressure capastan head, screwed both ends for iron pipe or for brass ferrule complete all as specifed.
S &F in repair 20 mm dia Gun metal half turn valve/ gate valve with iron wheel head, screwed both ends for GI pipe and fixed complete all as specified and directed.
S & F in repair PVC water storage tank three layer of 500 ltrs capacity, cylindrical, vertical with closed top, hoisted and fixed in position with and including 20 mm bore PTMT ball valve, high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for 20 mm bore iron pipe and connecting to inlet and outlet pipes complete all as specifed and directed.
S & F in replacement heating element of capacity of 3 KW, thread type, suitable for solar water heating system complete all as specified and directed.
S & F in replacement thermostat capacity 400W, suitable for solar water heating system complete all as specified and directed.
S &F in replacement silicon washer of size 45mm to 58mm suitable for solar water heating system complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with 200 Amp bus bar for double door 4 way IP-43 DB's, mounting flush on wall/concealed and making good distubed surfaces complete all as specified and directed by Engr-in-charge.
S &F in replacement Isolator TPN, 32 Amps breaking capacity 10 KA complete all as specified and directed Engr-in-charge.
S & F in replacement Isolator SPN, 40 Amps breaking capacity 10 KA complete all as specifed and directed Engr-in-charge.
S & F in replacement MCB, SP, 'C' series, 6-32 Amps 10 KA complete all as direced Engr-in-charge.
S & F in replacement glass evacuated tube of existng specification(dia 45 to 58 mm approx) for solar water heating system complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of LT panel board, CPRI approved, cubical type 440 Volts 3 phase 4 wire outdoor type front and back operated with adequate air ventilation at both sides & back, fabricated out of 3.15 thick CRCA sheet with double door shutter, water proof dust & vermin proof, pre fabricated hinges for rear & front door with locking arrangement complete with inter connection with copper wire / strip, tapping bonding to earth & all frames, inner & outer door shall be coated by polyster powder paint of shade RAL 7032 siemens grey, stand of distribution board shall be coated by primer & black bituminous paint, cable trays, cable lugs, cable glands, nut, bolt, washer etc of required size, provision for taking out cable duly marked / rivetted letters of appropriate size for each feeder cable & reconnection with duly insulated cable terminals with heat shirnkable sleeve with 1.1 KV grade danger notice board etc. including supply and fixing of the following Switch gears / ACB/ MCCBs / Fittings & Fixtures. The size of panel board shall be as per manufacturer's recommendation to accomodate following Switch gears / ACB/ MCCBs / Fittings & fixtures:-
(i) Bus bar chamber consisting four Nos copper busbar of capacity 800 Amp & 600 Amp for neutral duly insulated with heat shrinkable sleeve 1.1 kv grade with RYBN mounted on heavy duly epoxy insulator in separate compartment. (ii) LED indicating lamp (RYB) for incoming and outgoing feeder controlled with 2 Amp MCB single pole 'C' curve. (iii) Panel board internal wiring with suitable PVC insulated multistranded copper conductor flexiable cable heavy duty 1.5 time of MCCB rating upto 100 Amps and solid connection with suitable size strip for MCCB's rating above 100 Amps.
(v) INCOMINGS
(a) MCCB 415 Volts, 400 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 35 KA (Ics=100%Icu)- 1 Nos. Make C&S/L&T/Legrand.
(vi) OUTGOINGS
(a) MCCB 415 Volts, 200 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release, (Service Breaking Capacity 25 KA (Ics=100%Icu)-02 Nos. Make C&S/L&T/Legrand .
(b) MCCB 415 Volts, 160 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 25 KA (Ics=100%Icu)- 1 No. Make C&S/L&T/Legrand.
(c) MCCB 415 Volts, 63 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 16 KA (Ics=100%Icu)-1 No. Make C&S/L&T/Legrand.
(d) Street light time switch 20 Amps 415 V 3 phase with contactor -1 No. Make C&S/L&T/Legrand.
Note:- The item is inclusive of (i) Excavation & earth work required for taking out cable of any length & re-laying cable all terminal/bare conductor duly insulated of existing cable with heat shrinkable sleeve 1.1 KV grade. (ii) PCC foundation 45 cm below GL and 45 cm above GL & grouting 4 legs of panel box all as directed. (iii) Unit rate shall be deemed to be included taking down of dilapidated panel board including removing from site.
All as per item No 74.00 here in above but including supply and fixing of the following Switch gears / ACB/ MCCBs / Fittings & Fixtures.
(i) Bus bar chamber consisting four Nos copper busbar of capacity 400 Amp & 400 Amp for neutral duly insulated with heat shrinkable sleeve 1.1 kv grade with RYBN mounted on heavy duly epoxy insulator in separate compartment. (ii) LED indicating lamp (RYB) for incoming and outgoing feeder controlled with 2 Amp MCB single pole 'C' curve. (iii) Panel board internal wiring with suitable PVC insulated multistranded copper conductor flexiable cable heavy duty 1.5 time of MCCB rating upto 100 Amps and solid connection with suitable size strip for MCCB's rating above 100 Amps.
(v) INCOMINGS
(a) MCCB 415 Volts, 250 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 35 KA (Ics=100%Icu)- 1 Nos. Make C&S/L&T/Legrand.
(vi) OUTGOINGS
(a) MCCB 415 Volts, 160 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 25 KA (Ics=100%Icu)- 3 No. Make C&S/L&T/Legrand.
(b) MCCB 415 Volts, 63 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 16 KA (Ics=100%Icu)-1 No. Make C&S/L&T/Legrand.
M&L for collecting of water from designated pump house/ tube well in 5 ltr sterilized container and get the following parameters tested from Govt approve lab:- (a) PH, (b) Conductivity, (c) Total dissolved solids, (d) Turbidity, (e) Residual free chlorine, (f) Hardness (as CaCO3), (g) Chloride (as CI),(h) Iron (as Fe), (j) Alkalinity, (k) Total Coli form, (l) Fecal Coli form, (m) Taste, (n) Nitrate, (o) Sulfate, (p) Fluoride, (q) Aluminium, (r) Arsenic, (s) Chromium, (t) Copper, (u) Cadmium, (v) Calcium, (w) magnesium, (x) Manganese, (y) Lead, (z) Zinc, (aa) Color, (ab) Odour.
VIJAY ENTERPRISES
M/S Electrotech Sales
Friends fire Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .