| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-Finance 3 333 F M P ARCS VAZHAKULAM P O VENGACHUVADU ERNAKULAM KERALA 686670 | ERNAKULAM | KERALA | 686670 | L1 | Accepted-Finance L1 Bid | |
| 2 | L2₹7.3 L+₹99,036 (15.8%)Rejected-Finance | L2 | Rejected-Finance Not a Lowest Bid |
Tender Value
₹7.0 L
EMD Value
₹13,980
Closing Date
4 Jan 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director, CSIR-NIIST
CSIR-NIIST, Industrial Estate, Pappanamcode, Trivandrum
Electrical Renovation work adjacent to the library for extending the ITSU facility in CSIR-NIIST Campus, Trivandrum
2024_CSIR_221483_1
NIIST/WKS/013/NIT(20-1)24-25
Open Tender
Civil Works
Item Rate
60 days
TRIVANDRUM
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
DIRECTOR, CSIR-NIIST
₹13,980
11 Jul 2025
27 Dec 2024
6 Jan 2025
27 Dec 2024
4 Jan 2025
27 Dec 2024
Amount
DISTRIBUTION BOARD
Supplying and fixing following ways surface/ recess mounting, vertical type 415 volts on, VTPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of With 200 A Copper Busbar for each phase , common neutral link, earth bar, din bar for mounting MCBs ( But without MCBs and incomer) as required. 8 way (4+24), Double door
Supplying and fixing 5A to 32A rating, 240/415V, 10KA, « c » curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole-6A
Single pole-16A
Single pole-32A
Triple Pole-32A
Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing, etc. as required. (But without MCB/RCCB/Isolator) 8-way, Double door
Supplying and fixing following rating, double pole, ( single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commisioning etc. as required. 25A
Supplying and fixing following rating, four pole, ( three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commisioning etc. as required. 63A
WIRING FOR LIGHT / FAN / PLUG SOCKETS, ETC
Wiring for light point /fan/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc . as required. Group C
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FLRS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required. 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3X2.5 sq.mm
Supplying and fixing suitable size GI box with modular plate and cover in front on the surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non-residential buildings).
Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin5/6A modular socket outlet and 5/6A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on the surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required.
ENCLOSURES
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
LIGHT FIXTURES
Supply of 2'x2' LED recess Luminaire with CRCA housing and fully diffused prismatic diffuser with the following specifications: 230V, 50Hz supply, minimum lumens ≥3600, efficiency ≥ 100 lumens / Watt, Driver efficiency ≥ 85%, ≥4KV Surge protection, short circuit and overload protection, THD 0.9, CRI >80, CCT of 6500K (cool day light), IP20 protected, Lumen as per LM80 and life of LED @ 50k hrs, EMC compliance and confirming to IS: 10322 and IS:16108 with latest amendments.
Installation, testing, commisioning of wall bracket/ ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
BLDC FANS
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
CABLE TRAYS
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perfoaration not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
CABLE SUPPLY, LAYING & END TERMINATIONS
Supplying of one number 4 core 25 sq.mm, 1.1 KV grade, XLPE aluminium armoured power cable
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade following size on cable tray as required. Upto 35 sq.mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade following size on wall surface as required. Upto 35 sq.mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade following size on cable tray as required. Upto 185 sq.mm (clamped with 25/40X3 mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE alumium conductor cable of 1.1 KV grade as required. 4X25 sq.mm (28mm)
AIR CONDITIONERS
Supply, Installation, Testing & Commissioning of at least 3 Star rated- Inverter Hi wall mounted Split Air conditioners of 2 TR capacity with R-32 or R-410a Refrigerants.
Extra Copper Piping (In addition of 3.0 Mtrs std Supply with the unit ) between IDU & ODU of Sizes as per manufacturer standard with thermal insulation, PVC wrapping tape etc.
Supply & lying of Electrical Cabling between ODU to IDU for power/Communication etc. (size and core of the Cables as per Manufacturer standard ,Cable should not be jointed between IDU & ODU)
Supply & fixing of Condensate Drain pump for split ACs Max. flow 12L/h, Head 10m (flow rate 4L/h) Sound level 21dB(A) @ 1m Ref: Aspen Pumps-Mini Blanc or equivalent
Supply, fabricating , installation of 1.5/2 inch angle iron for ODU mounting as per site conditions , with necessary primer and painting
Supply & Installation of insulated PVC drain pipe of 32mm diameter with insulations neatly clamped or hanged on walls / ceiling and connecting with nearest drain point with Proper supports.
JAITECH ENGINEERS (BID ID -802634)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .