Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.1 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹4.2 L+₹9,672 (2.36%)Rejected-AOC MANIKANTA BHAVANAM THENMALA P O KOLLAM 691 308 | KOLLAM | KOLLAM | KERALA | 691308 | 2 | Rejected-AOC 2ND LOWEST | |
| 3 | 3₹4.2 L+₹12,409 (3.03%)Rejected-Finance SHIBU BHAVAN H NANTHIRIKKAL VELLIMON P O KOLLAM 691511 | KOLLAM | KOLLAM | KERALA | 691511 | 3 | Rejected-Finance 3RD | |
| 4 | 4₹4.4 L+₹32,378 (7.92%)Rejected-Finance | 4 | Rejected-Finance 4TH |
Tender Value
₹5.1 L
EMD Value
₹12,701
Closing Date
1 Mar 2023, 6:00 pmClosed
ASSISTANT ENGINEER
OFFICE OF ASSISTANT ENGINEER LSGD SECTION ARYANKAVU GP
240/22-23-Annual Plan-Aryankavu GP- CONSTRUCTION OF CULVERT AND APPROCH ROAD IN KARAYALARMETH PARAYIL ROAD
2023_LSGD_560421_3
AE/LSGD/ARKV/2022_23/PHASE 5
Open Tender
Civil Works - Roads
Item Rate
180 days
ARYANKAVU GP
SEE BID DOCUMENTS
8 documents required · 8 mandatory
₹1,125
₹12,701
20 Apr 2023
22 Feb 2023
4 Mar 2023
22 Feb 2023
1 Mar 2023
22 Feb 2023
Amount
CULVERT
OD350195/2022-2023:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 1.50m long (1m in rock and .50 m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete as per the direction of engineer in charge
11.1.1.1:Excavation for Structures <br> Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. <br> I. Ordinary soil <br> (i) Upto 3 m depth
OD340810/2022-2023:11.4.1.1 Modified (with out shuttering ) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br> I. P.C.C grade M 10 <br> (i) Nominal mix 1:3:6
12.5.1.1:Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 <br> For height upto 5 m <br> I. P.C.C grade M 15 <br> (i) Nominal mix (1:2.5:5)
13.1.2:Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5<br>R.C.C M 25
75.8.1.1.A:Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate:4 course aggregate) laid to required slope as required including compaction, finishingand tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixedin concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
12.7:Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
13.3:Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
SIDE PROTECTION WORK
11.1.1.1:Excavation for Structures <br> Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. <br> I. Ordinary soil <br> (i) Upto 3 m depth
OD349307/2022-2023:11.4.1.1 Modified (with out shuttering ) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br> I. P.C.C grade M 10 <br> (i) Nominal mix 1:3:6
11.4.2.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br>II. P.C.C grade M 15 <br> (i) Nominal mix (1:2.5:5)
11.8:Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
OD350316/2022-2023:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to<br>1.5 m as per direction of site Engineer-in-charge." <br>
HAND RAIL CONSTRUCTON
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
ROAD CONCRETE
OD350274/2022-2023:Surface dressing of the ground in All kinds of soil including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m
OD350278/2022-2023:11.4.1.1 Modified (with out shuttering ) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br> I. P.C.C grade M 10 <br> (i) Nominal mix 1:3:6
75.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)
75.8.1.1:Providing plain/reinforced concrete(1 cement:2 fine aggregate: 4 course aggregate) forsubstructure as per drawings and technical specifications Clause 802, 803, 1202 & 1203as required including compaction, finishing and tamping etc .complete. Max. size ofcourse aggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)
AMAL TIMBERS
SHIBU S
TRAVANCORE CONSTRUCTIONS
Bidder Name
TRAVANCORE CONSTRUCTIONS
AMAL TIMBERS
RAJU P
SHIBU S
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_825320.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .