Loading…
Loading…
Tender Value
₹30.0 L
EMD Value
₹30,000
Closing Date
14 Oct 2026, 4:00 pm
THE EXECUTIVE ENGINEER (O&M), M.G.V.C.L., DIVISION OFFICE, GODHRA
Works Advertised Tender for Erection, Dismantaling and Maintenance of HT/LT and Transformer center and Under ground work For Santraod Sdn OR Any Other SDn Under Godhra O&M Division. Rates are inclusive of Supply of N B.
348472
GDR/ERECTION/2026-27/40
Open
Electrical and Maintenance Works
Works
Panchmahal
2 documents required · 2 mandatory
₹1,180
MGVCL
₹30,000
24 Sept 2026
24 Sept 2026
24 Sept 2026
14 Oct 2026
24 Sept 2026
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC.
1 9901000001 COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING Number
COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
2 9902010001 FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF Number
PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF GUY
SET AND EARTHING - HT line
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
3 9902010002 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF GUY
SET AND EARTHING - LT Line
ERECTION OF STEEL POLES OF 8 TO 9 & 11 METERS INCLUDING EXCAVATION OF
PIT AND REFILLING OF EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE AND
4 9902010002 PAINTINGOF STEEL POLE, FABRICATED MATERIALS USED ON THE POLEAND Number
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET ANDEARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAYCROSSING ON
BG/MG/NG LINE FOR 0.400/11/22KV OVERHEADLINES I.E INCLUDING EXCAVATION
OF PIT & REFILLING OFEARTH, FIXING CROSS ARMS, TOP FITTING CLAMPS,ANTI-
5 9902010005 CLIMBING DEVICES DANGER BOARD, INSULATORS ETC. COMPLETE AND Number
PAINTING OF STEEL POLES, FABRICATEDMATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS 200 KG PSC POLES
INCLUDING EXCAVATION OF PITS & REFILLING OFEARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER
6 9902020001 BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATEDMATERIALS Number
USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING. (W/O
AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF 8 TO 9 METERS STEEL POLE
INCLUDING EXCAVATION OF PITS & REFILLING OFEARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARDS,
7 9902020007 INSULATORS ETC.COMPLETE & PAINTING OF POLES,FABRICATED Number
MATERIALSUSED ON THE POLES AND NUMBERING WITH COST OF PAINTSAS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
EARTHING. (W/O AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH, DO
FUSES OF 8 MTRS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,FIXING OF CHANNELS SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES, DANGER BOARDS, INSULATORS,DOFUSES ETC. COMPLETE
8 9902020006 Number
AND PAINTING OF FABRICATEDMATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDINGOF ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OFAB SWITCH, DO
FUSES, 9 TO 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, FIXING OF CHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND
9 9902020010 PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND Number
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OFAB SWITCH, DO
FUSES, 13 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, FIXING OF CHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND
10 9902020019 Number
PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
SCHEDULE - B
Works Advertised Tender for Erection, Dismantaling and Maintenance of HT/LT and Transformer center and Under ground work For
Santroad Sdn OR Any Other SDn Under Godhra O&M Division. Rates are inclusive of Supply of N B.
SR. Item Code
Description of Work Unit Rate in Rs.
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF DO FUSES,
TRANSFORMERS, LIGHTENINGARRESTORS, DISTRIBUTION BOX ETC. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE, FIXING OF
CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS,
11 9902030001 ANTICLIMBING DEVICESDANGER BOARDS, CONDUCTOR AND CABLE WIRING Number
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USEDON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OFAB SWITCH, DO
FUSES TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX 8 TO 9 &
11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTH CARTING OF TRANSFORMERS FROM STORE TO SITE, FIXING OF
12 9902030012 CHANNELS SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, Number
ANTICLIMBING DEVICES, DANGER BOARDS,CONDUCTOR AND CABLE WIRING
ETC. COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTIONS OF GUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING OF DO FUSES,
TRANSFORMERS, LIGHTENINGARRESTORS, DISTRIBUTION BOX ETC. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF
13 9902030016 CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, Number
ANTICLIMBING DEVICESDANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USEDON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND EARTHING.
ERECTION OF GUY SETS INCLUDING EXCAVATION OF PITS & REFILING OF EARTH,
AS PER STANDARD SPECIFICATION WITH STAY CLAMPS STAY WIRES, ANCHOR
14 9902040001 ROD, TURN BUCKLE, EYE BOLT, GUY INSULATOR, CEMENT CONCRETE BLOCK, Number
ETC., BUT EXCLUDING CONCRETING.
CONCRETING/ MUFFING OF POLES GUY ETC., INCLUDING COST OF CEMENT,AND
15 9905010001 METAL (1:2:4) AND WATER ETC., AS PER C.C.M-20 GRADE STANDARD CMT
SPECIFICATION .
ERECTION COIL TYPE EARTHING INCLUDING COST OF COAL & SALT, ETC.BUT
WITHOUT COST OF G I WIRE & COIL. AS PER STANDARD SPECIFICATION 10 KG
16 9902040002 SOLT + 10KG COAL.GI WIRE TO BE PASSED THROUGH PVC RIGID PIPE FOR Number
SUITABLE LENGTH AS PROVIDED BY THE S/DN ENGR. IN CHARGE
STRINGING OF 30 MM2 ACSR/34MM2 ,55MM2,AAA CONDUCTOR, FOR 11/22 KV & ONE COND
17 9903000001 L.T. LINE INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
SRTINGING OF 100 MM2, ACSR/DOG CONDUCTOR, FOR 11 KV & L.T.LINES
18 9903000002 INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING OF ALL
ACCESSORIES I.E. SPECIAL DESIGN SUSPENSION/TENTION CLAMP. FIXING OF
19 9903000006 CROSS ARM, LT SHACKLE INSULATOR, ETC FOR FIXING OF MESSENGER WIRE KM
COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE.
STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING OF ALL
ACCESSORIES I.E. SPECIAL DESIGN SUSPENSION/TENTION CLAMP. FIXING OF
CROSS ARM, LT SHACKLE INSULATOR, ETC FOR FIXING OF MESSENGER WIRE
20 9903000005 COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE. KM
STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN RURAL AREA INCLUDING
FIXING OF CROSS ARM, SPECIAL DESIGN SUSPENSION/TENTION CLAMP, BINDING
TO PIN INSULATOR, PREPARING SHACKLE POINT JUMPERS ETC AS REQUIRED &
21 9903000007 DIRECTED BY ENGINEER-IN-CHARGE. KM
STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN URBAN AREA INCLUDING
FIXING OF CROSS ARM, SPECIAL DESIGN SUSPENSION/TENTION CLAMP, BINDING
TO PIN INSULATOR, PREPARING SHACKLE POINT JUMPERS ETC AS REQUIRED &
22 9903000007 DIRECTED BY ENGINEER-IN-CHARGE. KM
23 9906000002 PROVIDING GUARDING TO HT LINE ON ROAD/RAIL CROSSING MTR
24 9906000001 PROVIDING GUARDING OF LT LINE ON ROAD/RAIL CROSSING MTR
25 9901000002 LT LINE TAPPING SINGLE PHASE. Number
26 9901000003 LT LINE TAPPING THREE PHASE. Number
LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING,HT LINE CROSSING AND
TELEPHONE LINE CROSSING ETC.(PER SPAN)
SCHEDULE - B
Works Advertised Tender for Erection, Dismantaling and Maintenance of HT/LT and Transformer center and Under ground work For
Santroad Sdn OR Any Other SDn Under Godhra O&M Division. Rates are inclusive of Supply of N B.
SR. Item Code
Description of Work Unit Rate in Rs.
Dismentalling of all size (8,9,11,13…mtrs.) of RSJ (girder) Poles including dimentalling of
28 9907000006 relevant channels, cross arms insulators, jumpers, binding, earthing etc. INCLUDING Cr. Number
Dismentalling of PSC Poles including dimentalling of relevant channels, cross arms
29 9907000002 Number
insulators, jumpers, binding, earthing etc. INCLUDING Cr. IN STORE
30 9907000009 Dismentalling of conductor from line. INCLUDING Cr.IN STORE KM
31 9907000012 Dismentalling of 8 MTR PSC D.P.Structure. INCLUDING Cr. IN STORE Number
Dismentalling of 8 TO 9 METER STEEL POLE D.P.Structure. INCLUDING Cr. IN STORE
32 9907000012 Number
Dismentalling of A.B.Cable from line. INCLUDING Cr. IN STORE OF FOLLOWING
33 9907000025 SIZES:A: 3 X 50MM2+16MM2+1X 35MM2 B: 3 X 35MM2+16MM2+1X 25MM2 KM
Dismentalling of A.B.Cable from line. INCLUDING Cr. IN STORE OF FOLLOWING SIZES:
Dismentalling of ABC OF FOLLOWING SIZES INCLUDING FITTING OF ALL
ACCESSORIES I.E. SPECIAL DESIGN SUSPENSION/TENTION CLAMP. FIXING OF
35 9907000025 CROSS ARM, LT SHACKLE INSULATOR, ETC FOR FIXING OF MESSENGER WIRE KM
COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE.
(i) 1x35mm2+1x25mm2 (ii) 1x35mm2+35mm2 Rural Area.
Dismentalling of ABC OF FOLLOWING SIZES INCLUDING FITTING OF ALL
ACCESSORIES I.E. SPECIAL DESIGN SUSPENSION/TENTION CLAMP. FIXING OF
36 9907000025 CROSS ARM, LT SHACKLE INSULATOR, ETC FOR FIXING OF MESSENGER WIRE KM
COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE.
(i) 1x35mm2+1x25mm2 (ii) 1x35mm2+35mm2 Rural Area.
INSTALLATION OF ENERGY METER & MMB/SMC BOX WITH ELECTRICAL WIRING
37 9911000057 ON TRANSFORMER Number
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC 2.4/4.0 MM2 TWIN
CORE CABLE FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF
38 9904010002 Number
METER & COMPLETE WORK AS PER STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION WITH PVC 4MM2/10MM2
FOUR CORE CABLE FROM TERMINAL POLE TO METERING POINT INCLUDING
39 9904010001 FIXING OF METER & COMPLETE WORK AS PER STANDARD SPECIFICATION BUT Number
EXCLUDING COST OF MATERIALS.
CARTING OF PSC POLE AT DESTINATION (ABOVE 5 KM)
40 9909000001 per pole
41 9909000006 CARTING OF RSJ POLE AT DESTINATION(9 & 11 Mtr) (ABOVE 5 KM) per pole
AUGMENTATION/DEAUGMENTATION OF TRANSFORMER(ANY CAPACITY)
42 9908000049 INCLUDING TRANSPORTATION & CREDIT OF OLD TRANSFORMER AT S/DN STORE Number
Moulding of cable joint (St.joint,indoor and outdoor) for XLPE cable- labour charges,for
43 9902050002 Urban area. Number
Moulding of cable joint (St.joint,indoor and outdoor) for XLPE cable- labour
44 9902050002 charges,forRural area. Number
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA FOR ERECTION
OF POLE/ GUY ETC. AS PER STANDARDSPECIFICATION OVER & ABOVE NORMAL
45 9902040010 COST COVEREDAGAINST EXCAVATION OF PIT UNDER NORMAL SOIL Number
FORERECTION OF POLE,GUY, DOUBLE POLE STRUCTURE EARTHING WITH THE
APPROVAL OF SUPDT.ENGINEER.
46 9911000002 PLUMBING/STRAIGHTENING OF PSC POLE Number
Dismentalling of HT ABC (Unbundling & Fixing of 95 mm2/71mm2 HT ABC on existing
48 9907000032 Unbundling of HT ABC(Unbundling & Fixing of 95 mm2/71mm2 HT ABC on existing Pole) Km
Stringing of Unbundled HT ABC(Unbundling & Fixing of 95 mm2/71mm2 HT ABC on
49 9903000008 per Cond
existing Pole)
Proving & Fixing of HEAT SHRINKABLE TYPE JOINTING KIT-OUT DOOR CABLE JOINT
50 0411000071 Number
FOR A.B. CABLE(95 mm sq)
Proving & Fixing of HEAT SHRINKABLE TYPE JOINTING KIT-OUT DOOR CABLE JOINT
51 0411000072 Number
FOR A.B. CABLE(70 mm sq)
11 KV INDOOR CABLE BOX FOR 95 SQMM XLPE CABLE
52 0411000055 Number
11 KV INDOOR CABLE BOX FOR 185 SQMM XLPE CABLE
53 0411000015 Number
11 KV INDOOR CABLE BOX FOR 240 SQMM XLPE CABLE
54 0411000056 Number
11 KV OUTDOOR CABLE BOX FOR 95 SQMM XLPE CABLE
55 0411000057 Number
11 KV OUTDOOR CABLE BOX FOR 185 SQMM XLPE CABLE
56 0411000006 Number
11 KV OUTDOOR CABLE BOX FOR 240 SQMM XLPE CABLE
57 0411000058 Number
SCHEDULE - B
Works Advertised Tender for Erection, Dismantaling and Maintenance of HT/LT and Transformer center and Under ground work For
Santroad Sdn OR Any Other SDn Under Godhra O&M Division. Rates are inclusive of Supply of N B.
SR. Item Code
Description of Work Unit Rate in Rs.
11KV STRAIGHT THROUGH JOINT FOR 95 SQMM XLPE CABLE
58 0411000059 Number
11KV STRAIGHT THROUGH JOINT FOR 185 SQMM XLPE CABLE
59 0411000074 Number
11KV STRAIGHT THROUGH JOINT FOR 240 SQMM XLPE CABLE
60 0411000060 Number
Supply of HDPE pipe for laying 11KV XLPE cable 110mm nominal diameter & 5.3 to 6 mm
61 9913000015 thickness as per IS:4984 meter
62 9913000014 Supply of medium grade GI pipe of size 4" dia(Including clamping the cable with pole) meter
Excavation of trench 0.5Mtr. Wide and 1 Mtr. Deep for laying of HT/LT underground cable
of size upto 300Sq.mm PILC or XLPE.(The cable should be laid on bed of sand and to
63 9913000036 cover cable with half round RCC pipe 6" internal dia and length of one meter along with meter
each bottom and top.) The entire trench there after should be refilled with earth dully
rammed up to ground level As perDrg.No MGVCL/Tech/UG Cable/01/12-13
Laying of U/G 11KV XLPE cable by Push & Pull method (MANUAL / BY Horizontal
Directional MACHINE)thru with HDPE pipe 110mm Diameter,5.3 to 6 mm thickness
64 9913000042 or 4" diameter GI Pipe without damaging surface of the road by horizontal boring / meter
drilling method (Excluding cost of HDPE pipe 4"GI Pipe) as per Drawing and
specification
Laying/Relaying of cable in Cable trench & from ground level to pole structure for providing
65 9913000038 outdoor cable joints. meter
Laying / Relaying XLPE/PILC cable by digging of pits, removal of old cable and laying of
66 9913000013 new cable on sand bad as per item No.1 above. meter
Supply of half round RCC hume pipe 6" internal dia & length of 1 Mtr.
67 0302000078 Number
Supply of sand 0.300x0.500X1.00mtr (Layer at bottom of cable trench approximately
68 9913000049 0.15cmt) As perDrg.No MGVCL/Tech/UG Cable/01/12-13 RMTR
Add : Charges for digging of tar road for laying of cables over and above digging of pit in
69 9913000041 normal soil as per Sr.No. 1 meter
providing & supplying, fixing route marker of C.C.1:2:4, 150mm x 150mmx750mm
concrete stone (MGVCL marked with approved yellow colour) embedded in Earth
70 9913000009 at least 300mm below the G.L. & 450mm above G.L. at distance approx. 100 Mtr. Number
or as directed by engineer incharge.(This Includes material & Labour charges for
excavation &refilling
Supply & fixing labour charge for providing Bricks (size 9"X 4"X3")layer (4" side layer
Nos of Bricks per meter length of cable Top side + 9" side layer 4.5 nos X 2 side=10+9=19
71 9501060079 Nos /Running Meter) for 11KV XLPE Cable Mechanical protection (only top sied layer) at Number
cable ring (loop) location, as per instruction of Engineer in Charge @ Rs. 4/- per Bricks
current market rate F.O.R Site delivery
72 9902010006 Erection of Support pole for stay PSC(Stud pole) Number
73 9902010007 Erection of Support pole for stay STP/RSJ(Stud pole) Number
74 9911000190 RE-JUMPERING OF HT/LT LINE FOR SHACKLE POLE PER POLE
Replacement of pole mounted 1-Ph/ 3 Ph . Service Connection Box including reconnecting
75 9911000221 Number
all connectio
76 9911000229 PIN BINDING OF 11KV PIN INSULATOR PER POLE
77 9911000230 PIN BINDING OF LT LINE PIN OR SHACKLE INSULATOR PER POLE
78 9908000003 REPLACEMENT OF 11 KV DISC INSULATOR Number
79 9908000166 REPLACEMENT OF LT PIN /SHACKLE INSULATOR Number
80 9911000226 Refixing of V cross -arms in proper position Number
81 9908000001 REPLACEMENT OF V CROSS - ARMS Number
82 9908000051 REPLACEMENT OF TOP FITTING Number
83 9911000226 Refixing of top fitting in proper position Number
84 9908000007 REPLACEMENT OF LT CROSS - ARMS Number
Replacement of old jumpers by new jumper/binding/lugs etc. from L.A. to D.O. Fuse or
85 9908000004 Per Jumper
D.O. Fuse to T/C
Replacement of 11KV PIN insulator by new Pin Insulator
86 9908000002 Number
/Composite Pin Insulator
Re-stringing of HT & LT line (55mm2 & 34mm2) conductors/ Coated conductor with new
double pin binding per span
Re-stringing of 11KV Aerial Bunch Cable (All size) per span
with accessory fittings
89 9911000009 Cutting of Tree branches obstructing HT/LT line on one tree Per Tree
Per Day per
90 9911000189 Cutting of bigger size of Tree branches / Whole tree obstructing HT/LT line
PROVIDING DO FUSE OR AB SWITCH ON DP (FOR ONE SET) WITH FABRICATION &
91 9908000169 COLOUR CODE JUMPER,INCLUDING PROPER ALIGNMENT OF AB SWITCH Number
SCHEDULE - B
Works Advertised Tender for Erection, Dismantaling and Maintenance of HT/LT and Transformer center and Under ground work For
Santroad Sdn OR Any Other SDn Under Godhra O&M Division. Rates are inclusive of Supply of N B.
SR. Item Code
Description of Work Unit Rate in Rs.
NUMBERING THE POLE WITH PAINT BY PREPARING BACK GROUND OF REQUIRED
HEIGHT SURFACE OF ONE COLOUR AND HAVE LETTERING ( 2" & 3" HT ) AS
92 9911000001 DIRECTED BY IN CHARGE ENGINEER .THE TWO COLOUR SHOULD HAVE BEEN Number
SLECTED AS TO HAVE CONTRAST FOR PROPER READABILITY.(REQUIRED
COLOUR TO BE PROVIDED BY CONTRACTER)
FIXING OF SMC (1-Ph) AT CONSUMER INSTALLATION ( INCLUDING COST OF
93 9911000222 Number
FIXING OF SMC (3-Ph) AT CONSUMER INSTALLATION ( INCLUDING COST OF
94 9911000223 Number
95 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Rural Number
96 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Urban Number
97 9911000227 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Rural Number
98 9911000228 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Urban Number
REPLACEMENT OF SINGLE PHASE OLD SERVICE BY NEW SERVICE INCL
99 9908000016 .SHORTFALL REEL INSULATORS, EGG INSULATORS, NAILS, FIXING FASTNERS Number
100 9902040007 Providing lighting arrestor on DP Structure Number
101 9911000007 Tightening of loose stay wire Number
REPLACEMENT OF OLD DISTRIBUTION BOX 200 KVA & ABOVE WITH MAKING ALL
102 9908000010 Number
CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
REPLACEMENT OF OLD DISTRIBUTION BOX UP TO 100 KVA & ABOVE WITH
103 9908000011 Number
MAKING ALL CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
104 9911000054 PROVIDING LINE SPACER BETWEEN LT LINE CONDUCTOR WITH BINDING Number
105 9911000070 Petrolling of HT line & submission of summary Report Per Pole
106 9911000071 Petrolling of LT line & submission of summary Report Per Pole
Fixing of V cross arm, Top fitting with jumpering (Unbundling & Fixing of 95 mm2/71mm2
HT ABC on existing Pole)
Fixing of Pin Insulator with Spindle(Unbundling & Fixing of 95 mm2/71mm2 HT ABC on
existing Pole)
Fixing of Shackle Insulator with Hardware(Unbundling & Fixing of 95 mm2/71mm2 HT ABC
on existing Pole)
110 2615000027 Supply of Wedge Type Tension assembly with IPC Number
111 2615000028 Supply of Helical Tie Number
112 0411000077 Supply of Mid span Joints (Tension Joints) Number
113 0411000078 Supply of IPC for Networking or Branching or Looping IPC Type 2 Number
114 0411000078 Supply of IPC for Bare to Covered interconnection IPC - Type 1 Number
115 0411000078 Supply of IPC with with Aluminum Ball for earthing IPC Type 3 Number
Laying,Testing & commissioning of Specially designed 11 KV AAAC/AL-59 Medium
Voltage Covered conductor as per the technical specifications (with accessories)
Grand Total
Grand Total
The rates are asked above only on percentage basis against estimated amount i.e. item wise rates stated in the Schedule-B. The tender offer
must be specifying the percentage either above or, below to the estimated amount and it should be clearly specified both in figures and words.
Above quantity are approximate and may vary as per requirement.
1 Above all Rates are inclusive of Bolt and Nut. Contractor to provide Bolt Nut as per company's specification.
Schedule quantity may be increase or decrease but total order value will not increase. Rates as per Labour cost data 2024
considered.
3 Contractor have to carry out maintenance work of 20 % of total order value issued.
Note: As far as possible there should not be a situation where re carting is required for more than 5 Kms. Poles should be carted from
Pole factory nearer to the pole requirement, However in exceptional circumstances if re-carting is required for more than 5 Kms up to
Kms then the carting rates specified may be paid with specific justification of requirement of carting for more than 5 Kms and with prior
approval of EE of division”.
5 On receipt of Sub work Order, immediately contact Engineer In charge of Concern S/dn for line marking of erection work.
SCHEDULE - B
Works Advertised Tender for Erection, Dismantaling and Maintenance of HT/LT and Transformer center and Under ground work For
Santroad Sdn OR Any Other SDn Under Godhra O&M Division. Rates are inclusive of Supply of N B.
SR. Item Code
Description of Work Unit Rate in Rs.
6 Work should be carried out under supervision of authorized MGVCL staff only.
7 T.S wise / Work wise material account of sub works order must be given separately.
8 The materials requisition (M.R) should be collected from Concern Sub Division office.
9 If work is delay for non-availability of any material or objection of line erection work, must be inform to Concern S/dn office in writing.
10 For extension of time limit of work order, you have to submit written request letter with valid genuine reason before one month.
11 On completion of work, you have to credit all balance materials to sdn. store
You have to prepare & submit works bill for Above work within 07 days with material inventory sheet & Material account sheet &
MR/CR/Gate pass copy & HT/LT/TC erected network sketch"
In case of any excess work required while actual execution of work you have to give written intimation to this office &No excess work
should be carried out without prior written permission / approval from competent authority.
14 For non -painting of RSJ Pole Rs. 1132/- charge deducted from bill amount.
For non -painting of PSC Pole fabrication Rs. 179/- per pole & for PSC DODP Rs. 380/- and for PSC TC DP fabrication Rs 776/- per DP
will be deducted from bill.
16 For non-painting of Pole numbering Rs. 60/- will be deducted per pole.
17 For live electric line crossing work, work should be carried out after Power cut-off and earthing of Line.
18 For any excavation/digging work, contractor has to take permission/NOC from “Call before you Dig” application
19 Mandatory Use of Pole Errection Devices / Machines for pole installation.
ENGINEER(O&M)
SIGNATURE OF CONTRACTOR
GODHRA DIVISION
(With Rubber Stamp & Date)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1Tender Notice and Condition .pdf
2.Schedule B Santroad.pdf
3Mandatory Use of Pole Erection Devices or Machines.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .