Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹84.4 L
EMD Value
₹50,000
Closing Date
12 Mar 2026, 2:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PWD BUILDINGS DIVISION, THALASSERY
GENERAL Annual Plan 2025 26 Construction of School Building (Phase I )for Government Higher Secondary School Palayad Kannur General Civil Work
2026_PWD_844339_1
86/2025-26
Open Tender
Civil Works - Buildings
Item Rate
Palayad
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
16 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
12 Mar 2026
6 Mar 2026
Appendix-A Building proper
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD217623/2024-2025:Providing and laying in position machine batched and machine mixed design mix M30 grade cement concrete for RCC work using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering shuttering, finishing and reinforcement including admixture in recommended properties as per IS:8103 to accelerate retard setting of concrete ,improve workability without impairing strength and durability as per direction of engineer -in charge. cement content considered for this work is 340kg/cm3 of concrete .excess /less cement as per mix design is not payable /not recoverable. detailed mix design to be supplemented .All work up to plinth level
OD217625/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for RCC work using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering shuttering, finishing and reinforcement including admixture in recommended properties as per IS:9103 to accelerate retard setting of concrete ,improve workability without impairing strength and durability as per direction of engineer -in charge. cement content considered for this work is 340kg/cm3 of concrete .excess /less cement as per mix design is not payable /recoverable. detailed mix design to be supplemented .All work above plinth level up to floor 5 level
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
stage.html
html • 0.02 MB
finance_1425472.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
SBD.pdf
Tender Documents • 1.63 MB
BOQ_1425472.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .