| 1 | L1₹2.4 LAccepted-AOC KOCHUKUDIYIL HOUSE EAST MARADY P O MUVATTUPUZHA | ERNAKULAM | KERALA | 680667 | ₹2.4 L Quoted ₹2.5 L | L1 | Accepted-AOC Work awarded to lowest bidder |
| Sl No | Description | Qty | Unit | KV SKARIA L1 |
|---|---|---|---|---|
| 1.00Annual Mainteance of shutter motors and the maintenance of panel accessories MCC panel | ||||
| 1.00 | OD140258/2025-2026:Annual maintenance of all motor, Main panel and Motor control panel - 3 nos and starter panels and DBs which inlcudes periodical cleaning of panel with blower and Checking and tightening of cable terminations of all the incoming & outgoing feeders of all the panels.
Checking & tightening of all the control cables of panels and .Checking the proper operation of switch gear items and attending all the minor repairs like changing damaged beeding and smc sheets and changing damaged knobs of all switch gear compartments and changing led indicators and push buttons and changing cont actors and relays in starter panel and voltmeters and ammeters and fuse links and Switch gears if needed ( excluding supply of ammeters and volt meters and indicators conatctors and relays) )and checking earth connection, attending repairs to all the compound lights including street light and flood lights including checking the fault and attending minor repairs( excluding fittings), servicing of stand alone solar street light in the boat jetty premises which includes cleaning of solar panel for removing dirt and dust checking connection and refilling the battery water in the existing batteries ensuring trouble free operation for a period of 12 months. | 12 | Month | 1,061.77 ₹12,741.24 |
| 1.00 | OD140250/2025-2026:Supply of LED indicators for all voltage ranges Red Green Black Yellow | 3 | each | 51.19 ₹153.57 |
| 1.00 | OD140249/2025-2026:Supply of damaged blue led indicators in the panel board | 3 | each | 78.75 ₹236.25 |
| 1.00 | OD140251/2025-2026:Supply of 63 A change over switch in the existing motor control panel of the shatter motor in the barrage of dam | 1 | each | 3,346.7 ₹3,346.70 |
| 1.00 | 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N | 1 | each | 3,620.53 ₹3,620.53 |
| 1.01 | OD140253/2025-2026:Supply of contactor MNX 25 in existing starter unit of the shutter motor of barrage by the instruction of engineer in charge. | 1 | each | 920.33 ₹920.33 |
| 1.01 | OD140254/2025-2026:Supply and Overload Relay 20-33 A (MN 2) in the existing motor starter unit in barrage as per the instruction of Engineer in charge. | 1 | each | 2,281.06 ₹2,281.06 |
| 1.01 | 90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. | 1 | each | 444.93 ₹444.93 |
| 1.01 | OD140256/2025-2026:Supply of Flush head Actuator - Red with legend 'stop', (Contact - 1 NC) in the existing motor starter unit in barrage as per the instruction of Engineer in charge. | 5 | each | 215.57 ₹1,077.85 |
Tender Value
₹2.5 L
EMD Value
₹6,338
Closing Date
27 Dec 2025, 3:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer Electrical Irrigation Sub Division Aluva
GENERAL-PVIP action plan 25-26-Fully comprehensive annual maintenance for shutter motors and starters and other connected electrical installation of Bhoothathankettu barrage for the year 2025-26 -General Electrical Work
2025_Irrig_820202_5
PWD/BLDG/MVIP/12399/2025-2026
Open Tender
Electrical Works
365 days
Aluva
Please refer Tender documents.
9 documents required · 9 mandatory
₹560
₹6,338
27 Feb 2026
18 Dec 2025
29 Dec 2025
18 Dec 2025
27 Dec 2025
18 Dec 2025
Amount
Annual Mainteance of shutter motors and the maintenance of panel accessories MCC panel
OD140258/2025-2026:Annual maintenance of all motor, Main panel and Motor control panel - 3 nos and starter panels and DBs which inlcudes periodical cleaning of panel with blower and Checking and tightening of cable terminations of all the incoming & outgoing feeders of all the panels. Checking & tightening of all the control cables of panels and .Checking the proper operation of switch gear items and attending all the minor repairs like changing damaged beeding and smc sheets and changing damaged knobs of all switch gear compartments and changing led indicators and push buttons and changing cont actors and relays in starter panel and voltmeters and ammeters and fuse links and Switch gears if needed ( excluding supply of ammeters and volt meters and indicators conatctors and relays) )and checking earth connection, attending repairs to all the compound lights including street light and flood lights including checking the fault and attending minor repairs( excluding fittings), servicing of stand alone solar street light in the boat jetty premises which includes cleaning of solar panel for removing dirt and dust checking connection and refilling the battery water in the existing batteries ensuring trouble free operation for a period of 12 months.
OD140250/2025-2026:Supply of LED indicators for all voltage ranges Red Green Black Yellow
OD140249/2025-2026:Supply of damaged blue led indicators in the panel board
OD140251/2025-2026:Supply of 63 A change over switch in the existing motor control panel of the shatter motor in the barrage of dam
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
OD140253/2025-2026:Supply of contactor MNX 25 in existing starter unit of the shutter motor of barrage by the instruction of engineer in charge.
OD140254/2025-2026:Supply and Overload Relay 20-33 A (MN 2) in the existing motor starter unit in barrage as per the instruction of Engineer in charge.
90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors.
OD140256/2025-2026:Supply of Flush head Actuator - Red with legend 'stop', (Contact - 1 NC) in the existing motor starter unit in barrage as per the instruction of Engineer in charge.
OD140252/2025-2026:Supply and fixing Flush head Actuator - Green with legend 'start', (Contact - 1 NO) in the existing motor starter unit in barrage as per the instruction of Engineer in charge.
OD140257/2025-2026:supply of fuse link 63 A for SDF in mcc panel
OD140259/2025-2026:Charges for rewinding the burnt rotor/stator - separate stater and rotor/stator, dismantling the damaged rotor/stator winding from the rotor/stator slots, cleaning the slots neatly, insulating the slots with correct class of insulating paper, winding the rotor/stator with good quality correct gauge of super enamelled copper winding wires, closing the rotor/stator slots with fibre wedges, putting proper inter layer insulation, connecting the coil end connection, providing new rotor/stator lead wire, steel binding the overhang with proper insulation at both ends, heating the coils and varnishing with good quality insulation varnish, keep it for drying, reassembling and test running(Less scrap copper)
OD140261/2025-2026:Disconnect all electric connections from the motor , decoupling the motor from shutter operating gear system and remove the base bolts from motor and base plate and kept the motor at safe place , checking and testing the stator and rotor winding. power greater than 15 HP,leading the motor to the nearest roadside using manpower, rope , chain, reaper etc. as required without getting damages to the motor, including loading into the vehicle and unloading at workshop for repairs and to and fro Conveyance.including resetting, refitting, coupling with shutter gear system, giving connection, taking trial run with full load etc. complete
OD176737/2025-2026:Supply and installation of 9 w led bulb in existing holder
90.12.5.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
Maintenance for the existing installation
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD140264/2025-2026:Supply of fire extinguisher dry chemical powder type - 5 kg
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Overhauling of 15 HP shutter motors
OD140248/2025-2026:Dismantling the15 HP motor into stator and rotor, cleaning the windings attending minor repairs, re taping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning and greasing the bearings with good quality grease, heating the windings, reassembling, refitting in position recoupling with mechanical gear system including scrapping, cleaning and painting with enamel paint, taking trial run at load.
Generator servicing
OD140268/2025-2026:Charges for replacing the damaged parts if required, cleaning the Diesel tank, Fuel Injection Pump Calibration/Repair, air filter cleaning, checking and clearing the exhaust system, fuel Injector Calibration /Repair, checking battery terminals and connections and top up battery water if required and checking the engine and alternator parameters to the existing 125KVA Diesel Generator set including take trial run as per the direction of department staff at site.
OD140271/2025-2026:Supply of engine oil 15W40 for topping up if required of 125kVA DG set
OD140270/2025-2026:Supply and renewal of Air filter assembly suitable for 125kVA DG set after dismantling the old one.
OD140273/2025-2026:Supply and renewal of Oil filter/fuel filter kit suitable for 125kVA DG set after dismantling the old one.
OD176493/2025-2026: Supply and renewal of water seperator suitable for 125kVA DG set after dismantling the old one.
OD174947/2025-2026:Charges for replacing the damaged parts if required, cleaning the Diesel tank, Fuel Injection Pump Calibration/Repair, air filter cleaning, checking and clearing the exhaust system, fuel Injector Calibration /Repair, checking battery terminals and connections and top up battery water if required and checking the engine and alternator parameters to the existing 35 KVA Diesel Generator set of PVIP IB including take trial run as per the direction of department staff at site.
OD176304/2025-2026:Supply of fuel filter/oil filter if damaged for 35 KVA DG Set
OD176305/2025-2026:Supply of control init of 35 Kva DG set
OD176798/2025-2026:Supply installation of 80 AH battery for 125 kva dg set Exide/equivalent make in palce of damaged one.
Bidder Name
KV SKARIA
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1378438.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.03 MB
Tendernotice_2.pdf
PDF • 0.10 MB
Tendernotice_3.pdf
PDF • 0.36 MB
NIT.pdf
Tender Documents • 0.02 MB
SBD.pdf
Tender Documents • 1.63 MB
MAKE.pdf
Tender Documents • 0.20 MB
BOQ_1378438.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid