Loading…
Loading…
Tender ID
Tender Value
₹39.3 L
EMD Value
₹39,290
Closing Date
7 Mar 2026, 6:00 pmClosed
Executive Engineer, Public Health Mechanical Division Rajkot
Emergency work S.I.T.C. of HMSM Pump Sets with Electro Mechanical Accessories and Equipments etc. Complete with 05 Months Comprehensive Operation & Maintenance & security work & Dismentling Work of machinery at Ghodadhroi HW under MMJ RWSS.(Khirai Group)
280752
48/2025-26 (3rd attempt)
Open
Pumps/Motors
Works
Rajkot
10 documents required · 9 mandatory · 1 optional
₹1,500
Yes
Executive Engineer, Public Health Works Division, Morbi
₹39,290
Yes
25 Feb 2026
25 Feb 2026
25 Feb 2026
7 Mar 2026
25 Feb 2026
Sr Supply 10% or
Supply of Horizontal mono submersible pump set of Cat SM-3.2 Monoset sub. pump 3 phase 400/440 vott, 50 c/s.
A.C. Supply & 2900 RPM , as per IS 14220 along with sand guard & cable (05 mtr length) etc. complete unit as per
1 detailed technical specifications & MOC : Casing: CI-FG260, Impeller : Bronze & Shaft : SS:410 of following capacity @ 9 Set 23717.00 0.00
2900 RPM(1000 lpm,24 mtr head)
Lowering/lying of openwell Horizontal Submersible pump sets/bore well pump sets with necessary tools and as per
instruction of engineer-in-charge.
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised
steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface
3 with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per 30 mtr 598.00 24.00
site requirement) conforming to IS:7098 (Part-1) & IEC:60502
(Part-1) of 1x 3.5 Core x 185 Sqmm sizes (GEB meter to MCCB to Junction box)
S.I.T.C. of Approved make four pole MCCB having breaking capacity ICU of 50 KA 415 V having normal current rating 400 A with variable
Thermal and magnetic release suitable to work on AC Supply 50 C/s with all internal connection spreader tinned copper and complete with
suitable size enclosure erected in 16 GMS Housing on angle frame or as per site requirement. (Cat.-III) (ICs 100% of ICU only Cat.-III)
Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet,dust&vermin proof having hinged door with rubber
gasket and necessary busbar supports with Aluminium busbar having current density not more than 0.8 Amp. / sq.mm (Rated current
5 /crosssectionarea)dulywrappedwith colour insulation tape for phase sequence, three phase & neutral each Suitable for following current 2 Rn.mtr 4856 234
capacity with necessary paintingmountedonwall orpedestal frameof required size with necessary connections.
Suitable for 300 Amp. capacity
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised
steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface
6 with necessary clamps / in existing cable trench / cable trays /dam/ conduit / pipe sleeves at road crossing or floor as 90 mtr 91.00 6.00
per site requirement) conforming to IS:7098 (Part-1) & IEC:60502
(Part-1)including all accessories of 1x 4 Core x 10 Sqmm sizes( Junction box to Panel)
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised
steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface
7 with necessary clamps / in existing cable trench / cable trays /dam/ conduit / pipe sleeves at road crossing or floor as 9000 mtr 64.00 6.00
per site requirement) conforming to IS:7098 (Part-1) & IEC:60502
(Part-1)including all accessories of 1x 3 Core x 6 Sqmm sizes( Panel to Pumpset)
Supply OF 11 to 15 HP Star Delta starter suitable for local & remote pump control application consisting of MPCB,
switch, run hour meter, required protective relays & control accessories.This item also includes APP type suitable
rating capacitor as per GWSSB rate contract specifications.
Installation and testing of Above mentioned 11 to 15 HP Star Delta starter with necessary fixtures materials
Manufacture, supply, delivery and instalation of ISI Marked H.D.P.E. Pipes (IS: 4984/1985 with latest amendment)
having pressure rating PN-10 and material grade PE 80 in approximate 100 meter coil length or as per GWSSB
requirement with SS- 316 Nipple at both end with SS Nut Bolt having 11 TPI threading as per specifications press
fitted and bolted. having 110 mm nominal diameter as per detailes techanical specifications.
11 Installation and testing of Above mentioned 110 mm dis HDPE pipe with necessary fixtures materials 4500.00 mtr. 0.00 39.20
Supply at Site, Storage, Erection, Installation, Testing & Commissioning of Flanges, Concentric Nozzles Bolts,
Nuts, and Connection Flanges, Eccentric Nozzles, etc. Complete. As per relavant IS and requirement. for
12 mmØ individual Delivery piping (HDPE) and 2000 kgs 98.00 11.36
Fabrication of ms frame structure for Pumpset as per site requirement with supply of necessary
required MS materials
Supply of Manpower for the operation, repair and maintenance and security of the machinery and accessories
13 and for the movement of the pumpset and accessories if necessary according to the level of the water in dam as 150 Days 0 4406.01
per instructions of the Engineer-in-charge.considering 9 manpower supplied.
14 Dismantling of pump motorset,cable, panel,pipe &other accessories etc.component & loading in vehicle 1 Job 0 26735.50
transportation to Departmental store and unloading at store and proper stacking including hydro,labour etc complete
15 Hiring of Hydra/Crane including Driver & diesel etc. complete. 1 Day 0 6412.47
16 Hiring of Tractor with trolley considering 8 hrs as working day hours including Driver etc. complete. 1 Day 0 2104.09
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if
17 required as per required gradient and line including safety provisions using site rails and stacking excavated stuff 500 Cu.mt 0 89.00
including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.(A) Upto 1.50 mt
depth A.In all sorts of soil and so murrum
Providing and Constuction cofferdam in river basin including excavation,filling, middle portion with
B.C.soil(in empty Cement/Gunny Bags) to the entire satisfaction of EIC till completion of the work including
18 800 Per Bag 10.00 0.00
dismantling coffer dam after completion of the work as directed by EIC.
(Bags Filled With sand brought from Outside)
Say Total Rs.
Estimated cost in words Rupees - :-thirty nine lakh twenty eight thousand six thousand hundred fifty six Only
Amount of my / our tender works out as under :
Estiamted Amount ( For Above) Rs.3928656.00 Estiamted Amount (for Below) Rs.3928656.00
Put to tender Rs. _______________________________ Put to tender Rs. ______________________
Add _____ Rs. ____________________________________ Deduct ___ below Rs. _______________
Net Total Rs. _______________________________________ Net Total Rs. ___________________________
In Words Rs. ______________________________ In Words Rs. __________________________
Sign of Contractor
Executive Engineer
P.H.Mechanical Division Rajkot
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.0 General Terms Condition. Ghodadhroi.pdf
2.0 Technical Specifications Ghodadhroi.pdf
2.2 Data sheets.pdf
3.0 Volume- III Specifications O AND M. final.pdf
4.0 Volume -I V Vendor List Ghodadhroi.pdf
05.0_Volume - V Price Bid.pdf
6.0 Schedule -B.pdf
7.0 Price Variation Paripatra 2023.pdf
8.0 SD EMD GR.pdf
9.0 BANK LIST and GR NEW.pdf
10.0 GST GR.pdf
11.0 DMO_2876_01-May-2025_273.pdf
12.0 SD GR.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .