Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.8 L+₹50,769 (2.09%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
16 Nov 2024, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
REPAIR AND MAINTENANCE OF WINDOW AND SPLIT TYPE AIR CONDITIONERS IN DOMESTIC AND TECH AREA AT AF STN HALWARA
2024_MES_679969_1
GE/HAL-50/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY c(i)
8 documents required · 8 mandatory
₹500
GE (AF) Halwara
₹60,000
Yes
18 Jan 2025
17 Oct 2024
18 Nov 2024
17 Oct 2024
16 Nov 2024
2 Nov 2024
Amount
Taking down carefully window / Split AC unit of any size, any type, any capacity from the fitting/mountings, disconnecting power cables, drain pipes & accessories etc for repairs and refixing the AC unit and connecting up complete after carrying out necessary repairs to the entire satisfaction of the engineer in charge including transportation, complete all as specified and directed. Note : Spare parts will be measured and paid separately under relevent items.
M&L for servicing and cleaning of window / split type AC unit of any size, any capacity by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of thermocoal for air tightness, testing etc, complete all as specified and directed.
M&L for removing the unserviceable blower motor double Shaft, suitable for window type AC 1.0/1.5/2.0 Ton and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing, complete all as specified and directed.
M&L for removing the unserviceable Out door fan motor suitable for Split type AC 1.5/2.0/3.0 Ton out door unit and rewinding of out door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing, complete all as specified and directed.
M&L for removing the unserviceable indoor motor suitable for Split type AC 1.5/2.0/3.0 Ton unit and rewinding of indoor door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing, complete all as specified and directed.
S&F in replacement blower motor double Shaft, suitable for window type AC 1.0/ 1.5/2.0 Ton single ended or double ended shaft as per OEM make & size, complete all as specified and directed.
S&F in replacement Out door fan motor suitable for Split type AC 1.5/2.0/3.0 Ton out door unit single ended as per OEM make and size, complete all as specified and directed.
S&F in replacement indoor motor suitable for Split type AC 1.5/2.0/3.0 Ton unit single ended as per OEM make and size, complete all as specified and directed.
Removing the unserviceable reciprocating compressor from window/Split type AC and supply and fix new compressor suitable for 1.0 Ton window/split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing make and size, complete all as specified and directed.
Removing the unserviceable rotary compressor from window/Split type AC and supply and fix new compressor suitable for 1.0 Ton window/split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make, complete all as specified and directed.
Removing the unserviceable reciprocating compressor from window/split type AC and supply and fix new compressor suitable for 1.5 Ton window/split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make, complete all as specified and directed.
Removing the unserviceable rotary compressor from window/split type AC and supply and fix new compressor suitable for 1.5 Ton window/split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make, complete all as specified and directed.
Removing the unserviceable reciprocating compressor from window/Split type AC and supply and fix new compressor suitable for 2.0 Ton window/ split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make, complete all as specified and directed.
Removing the unserviceable rotary compressor from window/Split type AC and supply and fix new compressor suitable for 2.0 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make, complete all as specified and directed.
Removing the unserviceable reciprocating compressor from window/Split type AC and supply and fix new compressor suitable for 3.0 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter and painting of base plate as per existing size and make, complete all as specified and directed.
M&L for shifting of air conditoner of any type / any capacity, any make with necessary addition / alteration to window / wall, complete all as specified and directed.
Dismantling of cooling (evaporator) coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper/aluminium cooling fins including brazing, welding etc replacement of copper/ aluminum tubing/fins as per site requirement, refixing in original position and testing etc, complete all as specified and directed.
Dismantling of condenser coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper / aluminium cooling fins including brazing, welding etc replacement of copper/aluminum tubing/fins as per site requirement, refixing in original position and testing etc, complete all as specified and directed.
S&F in replacement of cooling coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of cooling coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of cooling coil for split type AC 1.5Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of cooling coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of condenser coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of condenser coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of condenser coil for split type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of condenser coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of PVC drain pipe for split AC as per existing size, complete all as specified and directed.
S&F in replacement of starting capacitor of 50+6 Mfd as per Existing 50 Hz, AC suitable for 1.5/2 Ton A/C, complete all as specified and directed.
S&F in replacement of starting capacitor of 45+6 Mfd as per Existing 50 Hz , AC suitable for 1.5/2 Ton A/C, complete all as specified and directed.
S&F in replacement of starting capacitor of 45+2 Mfd as per Existing 50 Hz , AC suitable for 1.5/2 Ton A/C, complete all as specified and directed.
S&F in replacement of starting capacitor of 36+6 Mfd as per Existing 50 Hz , AC suitable for 1.5/2 Ton A/C, complete all as specified and directed.
S&F in replacement of starting capacitor of 36 Mfd as per Existing 50 Hz , AC suitable for 1.5/2 Ton A/C, complete all as specified and directed.
S&F in replacement of starting capacitor of 80 to 120 Mfd as per Existing 50 Hz , AC suitable for 1.5/2 Ton A/C, complete all as specified and directed.
S&F in replacement running capacitor 36 to 60 Mfd 50Hz ,as per Existing AC suitable for 1.5/2 Ton capacity AC, complete all as specified and directed.
S&F in replacement of capacitor 3 to 6 Mfd ,50Hz as per existing suitable for condenser motor of 1.5/2 Ton A/C capacity, complete all as specified and directed.
S&F in replacement over load protector suitable for 1.5 /2 Ton A/C, complete all as specified and directed.
S&F in replacement starting relay box type suitable for 1.5/2 Ton capacity, complete all as specified and directed.
S&F in replacement of air cleaning filter , washable/cleanable type for window/split type A/C 1.5/2 Ton capacity, complete all as specified and directed.
S&F in replacement of air filter pad of nylon cleanable/washable type of existing thickness for Split type A/C 1.5/2.0 ton Capacity as per existing, complete all as specified and directed.
S&F in replacement of front grill of window type A/C of capacity 1.5 / 2 Ton as per existing one, complete all as specified and directed.
S&F in replacement of thermostat suitable for 1.5 / 2 Ton capacity AC, complete all as specified and directed.
Material and Labour for replacement of blower Motor Blade suitable for Window Type AC 1.5/2 TR complete as per existing, complete all as specified and directed.
Supply and Fixing in replacement Blower for indoor split AC As per existing, complete all as specified and directed.
Disconnecting of PCB for repair of window type AC 1.5/2.0 TR including refixing in original position and testing etc, complete all as specified and directed.
Disconnecting of PCB for repair of split type AC 1.5/2.0 TR including refixing in original position and testing etc, complete all as specified and directed.
Supply and fix in replacement of PCB with remot for window type AC 1.5/2.0 TR, complete all as specified and directed.
Supply and fix in replacement of PCB with remot for split type AC 1.5/2.0 TR, complete all as specified and directed.
S&F in replacement of indoor unit for split type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
S&F in replacement of indoor unit for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed.
Material and labour for replacement of copper discharge tube of size 3/8" , duly nylon insulated, complete all as specified and directed. Note :- Only weight of copper tube shall be measured and paid.
Material and labour for replacement of copper suction tube of size 5/8" duly nylon insulated, complete all as specified and directed. Note :- Only weight of copper tube shall be measured and paid.
Material and labour for replacement of copper discharge tube of size 1/4" , duly nylon insulated, complete all as specified and directed. Note :- Only weight of copper tube shall be measured and paid.
Material and labour for replacement of copper discharge tube of size 1/2" , duly nylon insulated, complete all as specified and directed. Note :- Only weight of copper tube shall be measured and paid.
Supply & fixing Insulation material for any size, complete all as specified and directed.
Material and labour in replacement blade of condensor fan motor (as per sample) for window type AC cap 1.5/2.0 Ton, complete all as specified and directed.
Material and labour in replacement outdoor blade of condensor fan motor (as per sample) for split type AC cap 1.5/2.0 Ton, complete all as specified and directed.
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning of window type A/C Split type A/C of any type, any capacity, any make, complete all as specified and directed.
Supply and fix in replacement of pencil type driers made in brass heavy duty suitable for window / split type AC, complete all as specified and directed.
Supply and fix in replacement of pin Valve /gas charging Valvesuitable for window/split type AC, complete all as specified and directed.
Supply & fixing single pole & neutral enclosure with two pin and earth plug and socket including MCB SP 32A, complete all as specified and directed.
Supply and fix in replacement 4 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type, complete all as specified and directed.
Supply and fix in replacement 5 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, complete all as specified and directed.
Supply and fix in replacement MCB DP 32 Amps, 240 volts, complete all as specified and directed.
S&F in replacement Copper capillary tube any size suitable for window/split AC, complete all as specified and directed.
Supply and Fixing in replacement Blower for window AC 1.5/2.0 TR as per existing size, complete all as specified and directed.
S&F in replacement Brass Nuts (1/4" Dead Nuts), complete all as specified and directed.
S&F in replacement Flair Brass Nuts (1/2" Nuts), complete all as specified and directed.
S&F in repalcement Flair Brass Nuts (3/8" Nuts), complete all as specified and directed.
S&F in repalcement Flair Brass Nuts (5/8" Nuts), complete all as specified and directed.
S&F in repalcement Butane Cartage 414 ml Gas for Brazing/welding AC, complete all as specified and directed.
S&F in repalcement Bakalight Connecter (for AC Three Connection), complete all as specified and directed.
S&F in repalcement Brass Thimble for AC compressure (100 Pieces), complete all as specified and directed.
S&F in repalcement Copper Brazining Rod, complete all as specified and directed.
S&F in repalcement thread tape, complete all as specified and directed.
S&F in repalcement self adhesive tape (white Cello Tape) size 50mm X 30 mtr, complete all as specified and directed.
S&F in repalcement PVC insulation tape 25 mm X 25 m, complete all as specified and directed.
Supply and filling refrigerant mafron Gas M-22, complete all as specified and directed.
Supply and filling refrigerant gas R-134a, complete all as specified and directed.
Supply and filling refrigerant gas R-32, complete all as specified and directed.
Supply only high and low voltage relay 230V, 50 Hz suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed.
Supply only power circuit board 230V, 50 Hz suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed.
Supply only voltmeter 0-300V suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed.
Supply only Switch piano, flush type single pole, one way 16 Amps suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed.
Supply only internal transformer suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed.
Supply only indicator lamps of required colour suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed.
Supply only 3 way terminal connector suitable for single phase voltage stabilizer of capacity upto 5 KVA, complete all as specified and directed.
S&F in repalcement PVC Insulated and PVC Round Sheathed three Core, 6 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts, complete all as specified and directed.
S&F in repalcement PVC Insulated and PVC Round Sheathed three Core, 4.0 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts, complete all as specified and directed.
S&F in repalcement PVC Insulated and PVC Round Sheathed three Core, 2.5 sqmm Copper Conductor Heavy Duty Cables for Voltage Grade upto 1100 Volts, complete all as specified and directed.
Disconnecting of PCB for indoor and outdoor unit for repair of inverter type split AC 1.5/2.0 TR including refixing in original position after repair and testing etc, complete all as specified and directed.
Supply and fix in replacement of PCB with remot for inverter type split AC 1.5/2.0 TR complete incl testing of proper functioning of AC, complete all as specified and directed.
Supply and fix in replacement of out door fan motor suitable for inverter type Split AC 1.5/2.0 Ton out door unit single ended as per existing, complete all as specified and directed.
Supply and fix in replacement of indoor motor suitable for inverter type Split AC 1.5/2.0 Ton unit single ended as per existing one, complete all as specified and directed.
Disconnecting of indoor and outdoor fan motor for repair of inverter type split AC 1.5/2.0 TR including refixing in original position after rewinding motor, single phase, with super enamelled copper wire of existing gauge including replacement of gun metal bush, cleaning, greasing and connecting up all including testing, complete all as specified and directed.
JASSI TRADERS (BID ID -3161339)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .