| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹9.9 L Quoted ₹10.1 L | L1 | Accepted-AOC Being 1st lowest |
| 2 | L2₹11.3 L+₹1.2 L (11.6%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹11.3 L+₹1.2 L (11.6%) | L2 | Rejected-Finance Being 2nd lowest |
| 3 | L3₹12.7 L+₹2.6 L (25.8%)Rejected-Finance H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹12.7 L+₹2.6 L (25.8%) | L3 | Rejected-Finance Being 3rd lowest |
| 4 | L4₹15.0 L+₹4.9 L (48.9%)Rejected-Finance | ₹15.0 L+₹4.9 L (48.9%) | L4 | Rejected-Finance Being 4th lowest |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
23 Mar 2023, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION, SECURITY LIGHTS AND OTHER MISC E/M WORKS AT NHO UNDER GE CLEMENT TOWN
2022_MES_528584_4
GE/CLT/ Of 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class E Cat b(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹33,000
Yes
31 Mar 2023
3 Mar 2023
25 Mar 2023
4 Mar 2023
23 Mar 2023
10 Mar 2023
Amount
Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing DB’s any type including sheet metal enclosoure and MCB's and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material and labour for point wiring with 1.5 sq mm PVC insulated, unsheathed, stranded copper conductor (FRLS) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked PVC casing caping /surface conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface including provision of CI/Pressed steel terminal switch box for housing of normal piano switch/socket ,with plastic laminated sheet 3 mm thick fixed with brass screw and washers for normal piano switch / socket, or provision of PVC gang box where required along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLS ) as earth wire connected with main common earth dolly complete all as specified and directed for the following :- One light/fan/exhaust fan/bell point controlled by one, one-way Piano type switch 5/6 Amp. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item No. 4 here-in-before but one 3pin/5pin 5/6 Amps socket out let on same board controlled by one, one-way Piano type switch complete all specified and directed.
All as per item No. 4 here-in-before but one 3pin/5pin 5/6 Amps socket out let on independent board controlled by one, one-way Piano type switch complete all specified and directed .
All as per item No 4 above but with 2.5 Sqmm PVC insulated cable( FRLSH) and same size of earth wire for 15 Amps power point complete all as specified and directed.
Supply and fixing switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC complete all as specified and directed.
Supply and fixing switch piano flush single pole, one-way 16 Amp, 240 Volts AC complete all as specified and directed.
Supply and fixing socket out let 2in 1, 5 pin 5 Amps flush type complete all as specified and directed.
Supply and fixing socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:-( i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates (ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item No. 10 here-in-before but one 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
All as per item No. 10 here-in-before but one 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item No 10 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed.
Supply and fix Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC complete all as specified and directed.
Supply and fix switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed.
Supply and fix modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz complete all as specified and directed.
Supply and fix modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz complete all as specified and directed.
Supply and fixing step socket type modular fan regulator 120/280 V , 2 module complete all as specified and directed.
Supply and fix ceiling rose surface bakelite 65x25mm dia having three terminals ISI marked complete all as specified and directed.
Supply and fixing batton/angle holder insulated body with back plate, suitable for batten fittings complete all as specified and directed.
Supply and fix switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC Supply and fix complete all as specified and directed.
Supply and fix switch piano flush single pole, one-way 16 Amp, 240 Volts AC complete all as specified and directed.
Supply and fix bell push piano flush type single pole one way 6 Amps complete all as specified and directed.
Supply and fix socket out let 5 pin 6 Amps flush type complete all as specified and directed.
Supply and fix socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC complete all as specified and directed.
Supply and fix in repair stepped type electronic fan regulator flush type 120/280 V complete all as specified and directed.
Supply and fix in repair step socket type modular fan regulator 120/280 V , 2 module complete all as specified and directed. Make -Legrand, Cona/ SSK/Hair,
Supply and fix in repair of bell ding dong AC 230/240 Volts complete all as specified and directed.
Supply & fix in repair capacitor 2.5 mfd for fan complete all as specified and directed.
Supply and fix sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated busbar complete all as specified and directed.
Supply and fix sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 4 way with 200 Amps rated busbar complete all as specified and directed.
Supply and fix sheet metal enclosure double door for MCBs DB TPN (Three Pole and Neutral) 415 Volt AC 4 ways complete all as specified and directed.
Supply and fix load line DBs (TP&N) vertical fitted with Bus bars neutral links Blanking plates double door suitable for TP/ FP Frame MCCB as incommer and out going MCBs 4 ways complete all as specified and directed. Note:- MCCB and MCBs shall be measured and paid separately.
Supply and fix MCB SP 5 to 32 Amp 'B'series 10 KA repturing capacity complete all as specified and directed.
Supply and fix MCB SPN 40 Amp 240 V AC 10 KA repturing capacity complete all as specified and directed.
Supply and fix MCB TP 63 Amps 240 V 10 KA repturing capacity complete all as specified and directed.
M & L for painting of steel tublar pole 9 mtr long straight /tublar and mild steel work such as cross arm, clamp, nuts,bolts etc incl preparation of old painted surface and painting with black and yellow strip 15 cm long starting from black in alternate pattern up to 1.2 mtr height above couping and writting pole No with black paint having existing letter size complete all as specified and directed.
Supply and fixing in replacement LED luminaire 600mm X 600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glair free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in repair energy efficient LED lights fitting, 9/10 watt , 230 Volt, of 600 mm length,CCT 6000ºK to 6500° K , decorative ultra slim linear LED lighting fixture with extruded aluminium housing heat sink, environmental friendly, energy efficient LED light source more than1200 lumens , wall mounted mirror batten, integrated electronic driver, system efficacy not less than 140 lumens /watt CCT 6000 to 6500°K , surge protection range ≥ 2.5 KV , voltage protection range 120-300 volt AC, power factor > 0.95 total harmonic distortion < 20%, colour rendering index > 80, fixed on site with all accessories including 2 years warranty connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repair & replacement ,sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed.
Supply and fixing in repair round shape 6 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make :-Shakti/ Havell's/ Compton.
Supply and fixing in repair round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with 01 No, RCCB 25 Amp, 30 mili amps, DP, 240 Volts, AC complete all as specified and directed. Make - Legrand, ABB, Schnider or equivalent as approved by GE. (Note - Cost of cutting chases for enclosure concealed in wall of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates.)
Material and labour for design,supply, fabrication,Installation,testig and commissioning Factory made LT panel board, indoor type totally enclosed,dust and vermin proof, suitably ventilated, Wall/floor mounted, 415 volts, 3 phase and neutral 50 Hz AC supply system, fully comartmentalized,both sides openable made out of 3.15mm thick CRCA sheet protection of enclosure IP54 as per IS 2147 of 1962 with 7 tank process pre-treatment and powder coated of approved color including suitable framework/support made out of suitable size angle iron/flat iron front opening type with provison for cable entry with proper ferrule and cable glands internal wiring with PVC insulated multistandard copper conductor FRLS cable of adequate size(1.5sq mm) including reqired civil works anchoring bolts for fixing,PCC foundation etc. with and including following complete all as specified and directed. (a) Bus bar chamber : electrically grade shrouded alluminium bus bar of capacity 400Amp for each phase 200Amp for neutral and current density 0.80A/sq mm , including interconnection of all switch gear fixed on DMC insulator and provision of extension. (a) INCOMER (i) MCCB 4 Pole, 415 V, of capacity 400 Amps 36KA rupturing with thermo magnetic. (ii) Phase indicator LED (RYB ) -Indication -3 nos (b) Outgoing (i) MCCB 4Pole, 160Amps 16 KA 50 Hz 415 V -02 rupturing with thermo magnetic (ii) MCCB 4Pole, 125Amps 16 KA 50 Hz 415 V -02 rupturing with thermo magnetic (iii) MCCB 4Pole, 100Amps 10 KA 50 Hz 415 V -01 rupturing with thermo magnetic
Material and labour for design,supply, fabrication,Installation,testig and commissioning Factory made LT panel board,outdoor type totally enclosed,dust and vermin proof, suitably ventilated, Wall/floor mounted, 415 volts, 3 phase and neutral 50 Hz AC supply system, fully comartmentalized,both sides openable made out of 3.15mm thick CRCA sheet protection of enclosure IP54 as per IS 2147 of 1962 with 7 tank process pre-treatment and powder coated of approved color including suitable framework/support made out of suitable size angle iron/flat iron front opening type with provison for cable entry with proper ferrule and cable glands internal wiring with PVC insulated multistandard copper conductor FRLS cable of adequate size(1.5sq mm) including reqired civil works anchoring bolts for fixing,PCC foundation etc. with and including following complete all as specified and directed. (a) Bus bar chamber : electrically grade shrouded alluminium bus bar of capacity 400Amp for each phase 200Amp for neutral and current density 0.80A/sq mm , including interconnection of all switch gear fixed on DMC insulator and provision of extension. (a) INCOMER (i) MCCB 4 Pole, 415 V, of capacity 250 Amps 25 ka rupturing with thermo magnetic. (ii) Phase indicator LED (RYB ) -Indication -3nos. (b) Outgoing (i) MCCB 4Pole, 125Amps 16 KA 50 Hz 415 V -01 rupturing with thermo magnetic. (ii) MCCB 4Pole, 63 Amps 16 KA 50 Hz 415 V -04 rupturing with thermo magnetic.
Disconnecting electric connection & taking down defective ceiling fans/ Exhaust fans of any sweep and make carefully and dismantling for checking of bearing / bush replacement of defective items oiling, greasing and re-assembling complete all as specified and directed.
Hanging/fixing only repaired ceiling fan/exhaust of any sweep and connecting up with and including 3 core flexible PVC copper cable of suitable size from fan to ceiling rose complete all as specified & directed.
M&L for rewinding of ceiling fans of 1200/1400 mm sweep with super enameled copper wire of existing gauge including varnishing, insulation, taping, writing MES No with synthetic enameled paint and testing complete all as specified & directed.
M&L for rewinding of exhaust fan of 300/350/450 mm sweep with super enameled copper wire of existing gauge including varnishing, insulation, taping, writing MES No with synthetic enameled paint and testing complete all as specified & directed.
S&F ball bearing for ceiling fan/exhaust fan of any sweep as required at site complete all as specified and directed.
S&F gun metal bush bearing for any sweep of sweep ceiling fan/exhaust fan as required at site complete all as specified and directed.
S&F in replacement exhaust fan/ fresh air fan 250 mm sweep plastic body complete all as specified and directed.
S&F in replacement exhaust fan fan 300 mm sweep Matllic body complete all as specified and directed.
S&F in replacement exhaust fan 200 mm sweep Matllic body complete all as specified and directed.
S& F in replacement Decoretive gate light (size width 200 Xhight 227)mm made up of high grade unbreakable polycarbonate material suitable for retrofit LED bulb complete with IP 65 protection complete all as specified and directed.
S&F in replacement LED type Security light fitting 20watt made out of pressure dia aluminium hosing with heat resistant toughened glass and IP-66 protection complete all as specified and directed. Cat part No : LSTS-20-CDL/NL-M of make Crompton or equivalent in Havells, Phillips, shakti as approved by GE.
S& Fix in replacement LED post top post top ideal to lit up parks garden ways and gate light 20 Watt complete with IP 65 protection all as specified and directed. Crompton cat part No LPTH-20-WW and equivalent Havells/ C&S as approved by GE.
Supply and fix in replacement junction box made from SMC/FRP sheet ready made of size 300 X200X 100 mm having 100 A capacity for RYB and neutral with aluminum busbar with 4 way connector fixed to pole /Wall with MS clamp 25 X 5 mm and nut bolts.including MCB SP 6 Amp 10 KA 240V with aluminium lugs - 01 No complete all as specified and directed.
Supply, laying, commisioning and testing of 1.1KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable ( conforming to IS7098) ISI marked in trenches/ducts/through GI pipes under roads of size 25 sqmm 3.5 core complete all as specified and directed. (Note :- (i) The earth work ,GI pipe shall measured and paid seperately under appropriate item of Sch A.)
Supply, laying, commisioning and testing of 1.1KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable ( conforming to IS7098) ISI marked in trenches/ducts/through GI pipes under roads of size 10 sqmm 4 core complete all as specified and directed. (Note :- (i) The earth work ,GI pipe shall measured and paid seperately under appropriate item of Sch A.)
Supply, laying, commisioning and testing of 1.1KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable ( conforming to IS7098) ISI marked in trenches/ducts/through GI pipes under roads of size 16 sqmm 4 core complete all as specified and directed. (Note :- (i) The earth work ,GI pipe shall measured and paid seperately under appropriate item of Sch A.)
Supply, laying, commisioning and testing of 1.1KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable ( conforming to IS7098) ISI marked in trenches/ducts/through GI pipes under roads of size 10 sqmm 2 core complete all as specified and directed. (Note :- (i) The earth work ,GI pipe shall measured and paid seperately under appropriate item of Sch A.)
Excavation in trenches for taking out /laying of cable not exceeding 1.5mts deep and n.exceeding 1.5 m in wide in soft/ loose soil for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed.
Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in each layer in any type soil complete all as specified and directed.
M&L for sand cushioning withdry and clean fine river sand underground cable 8cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed. (Note :- Punned thickness shall be considered for payment purpose)
M&L for cable protection well brunt bricks comman burnt clay sub class 'B'designation 75 for protection of UG cable laid in trenches complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Material and labor for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick weld directly in ground. (earth pit not less then 2.25m depth below ground level at any tyoe of strata) with top edge of the earth plate not less then 1.5m below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate connected by 25x4 mm GI strip As earth lead by means of brass nut and bolt thimbles checked nut , washer including concrete chamber of PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate ) with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx300mm 15mm thick plaster in cm (1:4) funnel with wire mesh RCC pit cover of 320x320x80 mm size ( 1:2:4) type d1(using 20mm graded stone aggregate) reinforced with xpm all as shown in electrical plate no. 3 of MES SSR part 1(2009) and specified including and provision of GI strip upto 7.5m long with 20mm dia light weight GI pipe protection and water pipe of 20mm bore medium grade including all excavation and earth work and connecting earth strip to panel including testing on completion complete all as specified and directed by engineer incharge. Note - 1. RCC pit cover shall be precast of RCC (1:2:4) type D-1 80 mm thick reinforced with xpm weighting not less then 4kg /sq m. in lieu of CI cover. 2. Cost of additional GI strip upto 7.5m is deemed to be included in the rate quoted by the bidder.
M&L earth continuity conductor or main earthing lead fixed to wall on battan or recess or chases or burried in ground or drawn in /pipe or fixed to pole or any other indicated situation for loop earthing etc, as required but 25x4mm galvanised iron strip including down old complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Bedi Refrigeration Works
M/s Pradeep Kumar
M/S Aditya Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .