Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹23.6 L+₹4.2 L (21.7%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹24.3 L+₹4.9 L (25.4%)Rejected-Finance VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹24.3 L+₹5.0 L (25.6%)Rejected-Finance 164 ASRAF KHAN CHAWANI OPP HARTMAN COLLEGE BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹25.4 L+₹6.0 L (31.2%)Rejected-Finance THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
16 Sept 2023, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR / MAINT OF GEYSER, SOLAR WATER HEATER AND ALLIED WORKS UNDER GE (W) BAREILLY.
2023_MES_614878_1
8147/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹76,000
Yes
10 Oct 2023
21 Aug 2023
18 Sept 2023
21 Aug 2023
16 Sept 2023
4 Sept 2023
Amount
Taking down of unserviceable existing geyser, from existing location and fixing the same after necessary repair repair at existing/ new place incl all fixing arrangement nut, bolt / fastner as reqd at site complete all as specified and directed. Note: Spare parts shall be measured and paid seperately here in after.
S&F in repairs heating element 2.0 KW as triangular type / circular type or as per sample complete all as specified and directed.
S&F in repairs new inner shell of geyser capacity 25/35 liters of suitable size heavy duty of copper sheet complete with all suitable accessories complete all as specified and directed.
M&L for replacement of bottom cover in two parts of MS sheets not less than 22 gauge and pre treated in finished in white stove enameled paint as per existing size gauge in the geyser of any capacity / size complete all as specified and directed.
S&F only new safety pressure valve with vent to geysers as per latest ISI specification complete all as specified and directed.
M&L for Painting the outer surface of geyser capacity 25/35 ltrs as per original shade with two coats of synthetic enamel paint over a coat of primer by spray gun after scrapping the existing paint ,denting etc. filling depression with putty and refixing the geyser in position including water/electric connection and testing complete all as specified and directed.
M&L for Brazing/ welding to inner copper tank at leaking spots up to five leakage of geyser of capacity 25/35/50 liters of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed.
S&F assembly of geyser 25/35/50 ltr. capacity complete all as specified and directed.
Supply and Fixing in repairs Indicator lamp with new indicating lamp round/square, rectangular type as required at site, SP 230 Volt complete all as specified and directed.
Supply and Fixing in repairs PVC connection flexible heavy duty 60 cm long complete with chromium plated flair nuts with washers at both ends suitable for GI tubing 15 mm bore complete all as specified and directed.
Supply and Fixing in repairs thermostat 0 to 90 degree, ISI marked, 15 Amps capacity automatic cut off at desired temp of suitable size for Geyser complete all as specified and directed.
Supply and Fixing in repairs Plug top 15 Amps Make Anchor or equivalent complete all as specified and directed.
Supply and fixing Non return valve suitable for geysers complete all as specified all as directedby Engr-in-Charge.
Supply and fixing heating element ( sensor type) suitable for Crompton and Bajaj make new model geysers as per sample complete all as specified all as directedby Engr-in-Charge.
Supply and fixing PVC insulated multistranded copper conductor of size 2.5 sq mm 3 core complete all as specified all as directedby Engr-in-Charge.
Repair /Servicing complete Solar Water Systems by pouring the anti-corrosion/anti scaling agent solution in the make up tank to clear the water circulated pipes of heat convertors sets upto 4 glasses of capacity 200 LPD and drain out the solution by opening the nuts and bolts of dead plate placed at the end of the system and make the system serviceable as per site requirement complete incl cleaning of flat plate collector. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/PUF insulation/heating element/ thermostat/cold water storage tank/gate valves/metal clamps and ensure all connection to be leakproof complete all as specified and directed.Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/ heating element/thermostat/cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items (ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates
Repair /Servicing complete Solar Water Systems by pouring the anti-corrosion/anti scaling agent solution in the make up tank to clear the water circulated pipes of heat convertors sets upto 6 glasses of capacity 300 LPD and drain out the solution by opening the nuts and bolts of dead plate placed at the end of the system and make the system serviceable as per site requirement complete incl cleaning of flat plate collector. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/PUF insulation/heating element/ thermostat/cold water storage tank/gate valves/metal clamps and ensure all connection to be leakproof complete all as specified and directed.Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/ heating element/thermostat/cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items (ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates
Repair /Servicing complete Solar Water Systems by pouring the anti-corrosion/anti scaling agent solution in the make up tank to clear the water circulated pipes of heat convertors sets upto 10 glasses of capacity 500 LPD and drain out the solution by opening the nuts and bolts of dead plate placed at the end of the system and make the system serviceable as per site requirement complete incl cleaning of flat plate collector. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/PUF insulation/heating element/ thermostat/cold water storage tank/gate valves/metal clamps and ensure all connection to be leakproof complete all as specified and directed.Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/ heating element/thermostat/cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items (ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates
supply and fixing in replacement 3/8 inch dia copper tubing complete all as specified and directed .
Supply and fixing gasket of suitable size as per sample complete all as specified and directed .
Supply and fixing rubber hose pipe of 20mm inner dia and suitable thickness complete all as specified and directed .
Supply and fixing metal clamp for fixing rubber hose pipe including nut/bolts/washers and ensuring proper leakproof connection complete all as specified and directed .
Supply and fixing heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as specified and directed .
Supply and fixing only thermostat for heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as all as specified and directed .
Supply and fixing in replacement Gun metal gate valve ISI Marked with crutch or butter fly handle for 20 mm dia bore complete all as specified and directed.
Supply and fixing in replacement Gun metal gate valve ISI Marked with crutch or butter fly handle for 25 mm dia bore complete all as specified and directed.
M & L for One coat painting to existing steel structure of solar water heating system 500 Ltrs capacity including all supports with super enameled paint of approved colour complete all as specified and directed.
S& F in replacement of flat plate collector solar panel suitable for water heater of capacity 200 ltr. of certified ISI company Installed on roof top of single/double storey bldg. including all connected items such as hose pipe, nut bolt and dismantaling, complete of existing and all connected work ie , brazing/welding, reassembling and testing on completion and making the solar water heater functional in all aspects complete all as specified and directed.
All as Per S.No 28 above but for capacity 300 Ltr complete all as specified and directed.
All as Per S.No 28 above but for capacity 500 Ltr complete all as specified and directed.
Supply and fixing in replacement Insulated Hot water pipe GI medium grade, ISI marked, 15 mm bore including all fittings and fixing arrangements by taking out insulation & re- insulation as per manufacturer's recommendations complete all as specified and directed. NOTE : New insulation will be done with proper packing of galss wool,wire mesh and stainless steel SS 304 where required as per site requirement, insulation will be carried out with no extra cost on the item of schedule and will be measured and paid under this item of schedule).
All as per srl item No 31 here-in-before but for size 20 mm bore complete all as specified and directed. .
S&F in replacement of GI pipe 25 mm dia medium grade suitable for normal water supply with all fitting complete all as specified and directed.
S&F in replacement of GI pipe 15 mm dia medium grade suitable for normal water supply with all fitting complete all as specified and directed.
S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shapeor size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint making desert cooler stand complete with all mason work as reqd at site and making good to disturbed surfaces complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks of Capacity 500 Ltrs (cylindrical vertical with closed top) 3 layers , ISI Marked hoisted and fixed in position incl all fiitings as reqd at site for making connection and taking down of existing and making good to disturbed surfaces complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks of Capacity 250 Ltrs 3 layers ISI marked (cylindrical vertical with closed top) hoisted and fixed in position incl all fiitings as reqd at site for making connection and taking down of existing and making good to disturbed surfaces complete all as specified and directed.
Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed.
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes and covered with 3 mm thick plastic laminated sheet cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:-
(a) One light / fan/ exhaust fan point controlled by one switch.
(b) One 5 pin 5 Amp switch socket out let point on an independent board.
(c) One 5 pin 5 Amp socket out let point controlled by one switch on same board.
All as per item 39 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded incl 2.5 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified complete all as specified.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed.
S&F Socket outlet 2 in 1, 6 pin, 15/5A flush type complete all as specified and directed.
Supply and Fixing in repairs P/switch flush type 5/6 Amp SP one way complete all as specified and directed.
Supply and Fixing in repairs P/switch flush type 15/16 Amp SP one way complete all as specified and directed.
Supply and Fixing in repairs ceiling rose 2/3 terminals complete all as specified and directed.
Supply and Fixing in repairs lamp holder PVC Angular/ pendent/ bakelite complete all as specified and directed.
Supply and Fixing in repairs buzzer, capton ding dong, AC, 230V, single pole complete all as specified and directed.
Supply and fixing bell push switch flush type complete all as specified and directed.
Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type complete all as specified and directed.
Supply and Fixing in repairs socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type complete all as specified and directed.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' X 11'' including cutting of sheet for fixing switch / socket complete all as specified and directed.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' x 5'' including cutting of sheet for fixing switch / socket complete all as specified and directed.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 5'' x 5'' including cutting of sheet for fixing switch / socket complete all as specified and directed.
Supply and Fixing in repairs MCB SPN 32 to 63 Amps 240 volts, 10kA complete all as specified and directed.
Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA, complete all as specified and directed.
Supply and Fixing in repairs MCB TPN 63 Amps, 415V, 10kA complete all as specified and directed.
S &F MCCB 16 kA, 125 Amp thermal magnetic and electronic earth leakage module incl dismantling of old existing MCCB of any description complete all as specified and directed.
Taking down unserviceable existing sub main wiring with aluminium conductor stranded cable upto 6 Sqmm single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed.
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 4 way with 200 Amps rated copper bus bar complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of SPN DB 4 ways complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of SPN DB 8 ways complete all as specified and directed.
Supply and Fixing in repairs 4 Pin CFL lamp 36Watt, 50Hz, 240V complete all as specified and directed.
S&F in repairs building security light LED type 20 watt including GI pipe bracket 32 mm dia with clamp including complete connection wih copper wire complete all as specified and directed.
S&F 2'x 2' in repairs LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F electronic driver of street light 20 to 70 Watt of any make complete all as specified and directed.
S&F electronic driver of 36 Watt LED panel of any make complete all as per sample complete all as specified and directed.
S&F in replacement LED batten with aluminium housing and integrated electronic driver 20watt 4 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed. Make Cat Pt No LUMILINE+BS 20WLED830SPCSS of Havells , Orient Cat Pt No LBLN-20-C-SQ-AL.Jaquar Cat Pt No LKBS01SO20XC or equivalent in Make Philips,Bajaj
S&F in replacement of PVC non metallic casing caping of 25 mm size with accessories including dismentaling/takingdown of old unserviceable/broken PVC conduit/cashing caping fixed on surface/concealed inclduing making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Supply and Fixing in replacement of PVC insulated Flexible twin core,copper cable multistranded 24/.0020sqmm,1100 V grade complete all as specified and directed.
Supply and Fixing in replacement of PVC insulated multistranded copper conductor of size 1.5 sq mm , 1100 V grade complete all as specified and directed.
Supply and Fixing in replacement of PVC insulated multistranded copper conductor of size 2.5 sq mm , 1100 V grade complete all as specified and directed.
Supply and Fixing in replacement of PVC insulated multistranded copper conductor of size 4.0 sq mm , 1100 V grade complete all as specified and directed.
Supply and Fixing in replacement of PVC insulated multistranded copper conductor of size 6.0 sq mm , 1100 V grade complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe including testing after completion complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 10 sq. mm x 2 core nominal cross section complete all as specified and directed.
Supply and fixing in replacement of new generation IP 65 LED post top family , energy saving , environmental friendly , long life aesthetically designed with symmertical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, Opal cover with all fixing arrangement as reqd at site of cap 15 Watt complete all as specified and directed. Make Cat part No. CORALMINIPT15WLED830PSYMTOPC of Make-Havells or equivalent in Make Philips, Crompton
Notes :- (i) For ser No. 01 to 34 items the Contractor has to complete the work assigned for above items with in 24 hours failing in which recovery at the rate 25 Rs. per day per complaint. (ii) For Serial No 35 to 81: The Contractor has to complete the work assigned for above items with in 36 hours failing in which recovery at the rate 25 Rs. per day per complaint. (iii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cell and get them signed from user after completing the job and submit to E/M complaint cell. (iv)Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
RAZA ENTERPRISES
M/S MAHIRA ENTERPRISES
indiatraders
S S ELECTRICALS
N S ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .