Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹26.8 L+₹2.1 L (8.49%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹27.8 L+₹3.1 L (12.7%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹30.8 L+₹6.2 L (25.0%)Rejected-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-AOC Not Lowest |
Tender Value
₹29.1 L
EMD Value
₹58,260
Closing Date
26 Feb 2022, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
SPECIAL REPAIR / REPLACEMENT OF CERTAIN E/M ASSETS AT SITE 1A AND 1B OF SU AT AF STATION JODHPUR
2022_MES_504853_1
8505/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Jodhpur
₹58,260
Yes
14 Mar 2022
31 Jan 2022
28 Feb 2022
31 Jan 2022
26 Feb 2022
14 Feb 2022
Amount
Supply and fixing in replacement of single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of aluminium strip 25mm x 3.15 mm complete with saddles and fixing screws etc. for roof conductors and down conductors above ground, fitting the strip including Al/SS/GI pipe fabrication support structure providing with suitable base plate should have provision system termination arrangement for the dowm conductors complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement of Galvanised iron strip of size 32x6 mm complete with saddles and fixing screw for fitting complete all as specified and directed by Engineer-in-Charge.
Material and labour for test point terminal block made out of gun metal or phosphoraus bronze size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexazonal head screw complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 25mm x 4 mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
Supply and fixing steel tubular swaged poles type 410 SP-55, 11 metre long complete with CI base plate and final including top cover bracket of required size, painting to the complete pole with two coats of synthetic enamel paint, over one coat of primer complete including zebra painting, numbering the poles with synthetic enamel paint, including taking out old unserviceable PCC pole of any type and size complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches in HARD ROCK, not exceeding 1.5m wide and not exceeding 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc area not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc area not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches in HARD ROCK, not exceeding 1.5m wide and exceeding 1.5 but not exceeding 03 metre in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc area not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches in soft/loose soil, not exceeding 1.5m wide and exceeding 1.5 metre but not exceeding 3.0 metre in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc area not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and directed by the Engineer-in-Charge.
Material & labour for plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) for pole coping including necessary formwork complete as directed by Engineer-in-Charge.
Material & labour for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, pedestal for pole including necessary weathering and formwork complete as directed by Engineer-in-Charge.
Supply & fixing in replacement of PVC Junction box for street light central with linked door control including 6 Amp MCB SP - 02 No with aluminium bus bar TPN for controlling the Street Lights complete with pole mounting type size 300x300x150mm including mild steel clamp of required size with bolts, nuts and washer complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 25 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor laid in trenches or fixed to wall/pol etc complete all as specified by Engineer-in-Charge. Note:- Earthwork, sand cushioning and stone patti etc. shall be measured and paid seperately.
Supply & fixing 50mm bore, light grade, galvanised iron pipe, with all fittings and required accessories & fixed complete to walls & ceiling or laid in floor complete all as specified & directed by the Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soil complete all as specified and directed by the Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Material & labour for sand cushioning for PVC cable with tibba sand (one layer of 80 mm thickness before laying of cable and other layer of 150 mm thickness after laying of cable) & punning down to 180 mm to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note:- Punned thickness only shall be measured and paid.
Material & labour for 40 to 50 mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and not less than 50 cm in length , laid dry abutting each other for protection of cable complete all as specified and directed.
Supply and fixing FRLS cable PVC insulated multi-stranded copper conductor of size 2.5 Sqmm 2 core for connection of light to junction box complete all as specified by Engineer-in-Charge.
Material & labour in replacement of cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint etc complete all as specified and directed.
Supply and fixing in replacement of Energy saving LED flood light fittings 150 W capacity with built in control box (IP-66) with potted driver suitable for outdoor application with all necessary accessories required for mounting of light complete all as specified and directed by Engineer-in-Charge.
Material and labour for overhauling of DG Set of capacity 200 KVA, Make CG, 415 Volts 50 Hz, 06 cylinder engine Model No TBD3V6MKI complete including dismantling of tapped cover, engine head asseembly, engine block, removing piston assembly, connecting rods assembly, cleaning , servicing and overhauling to engine, grinding crank as per required size, resurfacing cylinder head, replacing and grinding valve seats, replacing cylinder inner and piston, adjusting tapped gap and rocker arm assembly, reassembling all the dismantled components to its original position including testing the machine to its optimum efficiency to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge. Note :- Replacement of spare parts in engine shall be measured and paid separately as supply only.
Supply only liner complete of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only piston of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only piston ring and oil ring set of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only tepid valve of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only valve guide of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only injector sleeve of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only CR bearing of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only hose pipe kit of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only hose clampt of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only Thermostate valve of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only Water temperature gauge of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only Oil pressure gauge of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only Disel filter complete all as specified and directed by Engineer-in-Charge.
Supply only Oil filter complete all as specified and directed by Engineer-in-Charge.
Supply only Fuel pipe set complete all as specified and directed by Engineer-in-Charge.
Supply only Packing kit complete all as specified and directed by Engineer-in-Charge.
Supply only Liner 'O' Ring complete all as specified and directed by Engineer-in-Charge.
Supply only Head gasket complete all as specified and directed by Engineer-in-Charge.
Supply only 'O' Ring kit complete all as specified and directed by Engineer-in-Charge.
Supply only Injector sleeve 'O' Ring complete all as specified and directed by Engineer-in-Charge.
Supply only Water pump complete all as specified and directed by Engineer-in-Charge.
Supply only Turbo repair Kit complete all as specified and directed by Engineer-in-Charge.
Head repairing of DG Set complete all as specified and directed by Engineer-in-Charge.
Calibration of fuel injector pump complete all as specified and directed by Engineer-in-Charge.
Calibration of injector/Nozzel complete all as specified and directed by Engineer-in-Charge.
Supply only Air filter complete all as specified and directed by Engineer-in-Charge.
Supply only Dynamo complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil multigrade 20w40 complete all as specified and directed by Engineer-in-Charge.
Supply only Coolant complete all as specified and directed by Engineer-in-Charge.
Supply only Fan belts of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply only Battery 12V 180AH complete all as specified and directed by Engineer-in-Charge.
Cleaning of radiator by cleaning agent, descaling by means of scale solvent as well as neutralizing and arrest leakage by means of brazing etc complete all as specified and directed by Engineer-in-Charge.
Shri Electrical Enterprises
Nvimal Engineers and Contractor
M/S KAUTILYA GARG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .