| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.5 L+₹1.8 L (4.79%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹42.7 L+₹5.0 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹43.2 L+₹5.5 L (14.6%)Rejected-Finance ANAND GUJARAT 388001 | ANAND | GUJARAT | 388001 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹44.0 L+₹6.3 L (16.7%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
27 Sept 2021, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
REPAIR/REPLACEMENT OF INTERNAL WIRING AND CONNECTED WORKS FOR ZONE A AND REPAIR /REPLACEMENT AND MAINTENANCE OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS AND ALL TYPE OF GEYSERS INCLUDING CONNECTED WORKS AT OFFRS/JCOS/OR ACCN AT BARRACKPORE UNDER
2021_MES_473173_1
8543/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹79,000
Yes
9 Oct 2021
6 Sept 2021
29 Sept 2021
6 Sept 2021
27 Sept 2021
22 Sept 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for surface point wiring complete with two single core 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing and caping of size 20mm, ISI marked (medium grade) as required at site with all accessories such as Tee, corner, over laping, connector etc on walls / roofs / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for casing & caping entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of bakelite laminated top cover 3mm thick, blanking plate, numbers of switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed , single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces and applying white/ colour wash/distemper over applying putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch .
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One light point controlled by two Nos two way switches .
All as per Item No.2.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch .
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One light point controlled by two Nos two way switches .
All as per Item No.4.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
All as per Item No.4.00 here-in-before but point wiring with 4sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed.
S&F for modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 10 Amps, 2way, single pole,1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular bell push, 10Amps, 1 module, single pole, 1 way, 240V, ISI Marked complete all as specified and directed.
S&F for modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F for ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F for modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked as in repair complete all as specified and directed.
S&F for modular switch 10 Amps, 2way, single pole,1 module, 240V, AC, ISI Marked as in repair complete all as specified and directed.
S&F for modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked as in repair complete all as specified and directed.
S&F for modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked as in repair complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked as in repair complete all as specified and directed.
S&F for modular bell push, 10Amps, 1 module, single pole, 1 way, 240V, ISI Marked complete in repairs all as specified and directed.
S&F for modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked as in repair complete all as specified and directed.
S&F for modular red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module, ISI Marked complete all as specified and directed.
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F for switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for switch socket combination, 6Amps, 5 pin, flush type, 2in 1, 240 volts, ISI marked complete all as specified and directed.
S&F for switch socket combination, 6/16Amps, 6 pin, 240 volts, 2in 1, ISI marked complete all as specified and directed.
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing as in repair complete all as specified and directed.
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked as in repair complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete as in repair all as specified and directed.
S&F for call bell ding-dong sound type, 230 Volts, 50 Hz, AC, ISI marked as in repair complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, buzzer type ISI marked complete as in repair all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC as in repair complete all as specified and directed.
S&F for switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked as in repair complete all as specified and directed.
S&F for switch socket combination, 6Amps, 5 pin, flush type, 2in 1, 240 volts, ISI marked as in repair complete all as specified and directed.
S&F for switch socket combination, 6/16Amps, 6 pin, 240 volts, 2in 1, ISI marked as in repair complete all as specified and directed.
S&F for switch socket combination, 6/16Amps, 6 pin, neon indicator type, 240 volts, ISI marked complete as in repair all as specified and directed.
S&F for batten holder /angle lamp holder, PVC/polycarbonate type, ISI marked as in repair complete all as specified and directed.
S&F for decorative box type 20 -22watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells/Bajaj/Crompton as approved)
S&F for recess mounting 2'x2' LED 34/36 Watt light fittings with LED lamp and required driver, slim in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout modular ceiling grid and also can be suspended with provided kit and necessary electric connection with and including required size three coat sheathed flexible copper conductor cable from looping box to light fitting and testing complete all as specified and directed. (Make: Bajaj Cat No. BCTBLR 36W LED FP CW/Crompton Cat No.LCTLSNE-36-F0-CDL/ Havells Cat No.PLUTOSURFACE4X1PLS34WLED857S as approved)
S&F for decorative type surface mounted 1X6 watts LED light fitting with LED lamps including fixing arrangements at any height with nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of required size complete all as specified and directed. (Make: Crompton cat No.LCDEP-06-CDL / Havells cat No EDGEPRORDDLR6WLED857S as approved)
S&F for 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary electric connection with suitable size copper cable after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED as approved)
S&F for 70/72 watt LED secruity light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 72W LED V3/ Crompton cat No.CRP-409-70-57-SL-GL-NSG /Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG as approved)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer after and including taking down existing unserviceable bracket complete all as specified and directed .
S&F for powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 8 way plus 24 modules, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 200Amps, FP and MCB SP /TP MCB's as outgoing and complete connecting cable links with top and bottom with IP43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make: Legrand cat No.5077 32, 8 way / Hager Cat No.VYVO8DM-P / L&T Cat No.DBVTH008DD as approved)
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 8 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat as iafter and including taking down existing unserviceable DB complete all as specified and directed . (Make:- Legrand cat No. 5076 82 8 way / Hager Cat No.VYT08DH/ L&T Cat No. DBTPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make:- Legrand cat No. 5076 80 4 way / Hager Cat No.VYT04DH/ L&T Cat No. DBTPN004GD as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 4 way for flush mounting with 100 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make:- Legrand cat No. 5076 20 4 way / Hager cat No.VYS04D / L&T Cat No. DBSPN004GD as approved).
S&F for suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts after and including taking down of unserviceable one complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed (Make: L&T /Havells/Legrand as approved)
S&F for MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T /Havells/Legrand as approved)
S&F for MCB, four pole, 63 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T /Havells/Legrand as approved)
S&F for MCCB, 100 Amps, 4 pole, 25KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz after and including taking down existing unserviceable MCCB complete all as specified and directed . (Make - L&T Cat No. CM91712OOKOOG /Legrand Cat No. 4200-55 /Hager Cat no. HHA101U as approved)
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of existing unserviceable submain wiring complete all as specified and directed. (Note : Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of existing unserviceable submain wiring complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of existing unserviceable submain wiring complete all as specified and directed . (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
Taking down carefully ceiling fans at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder,terminal adoptor,screws,nuts,spring washers for blade/body etc and replacement of components/accessories such as ball bearings,gun metal bushes,capacitor,canopy top& bottom, shackle clip assembly and assembling of all parts including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only (ii) Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule. (iii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate
All as per item No.64.00 here-in-before but exhaust fan of PVC/metal body 250mm sweep complete all as specified and directed.
All as per item No.64.00 here-in-before but exhaust fan of metal body 300mm sweep complete all as specified and directed.
All as per item No.64.00 here-in-before but exhaust fan of metal body 380mm sweep to 450 mm sweep complete all as specified and directed..
All as per item No.64.00 here-in-before but Air circulator wall mounted type 450 mm to 600 mm sweep including carrying out repairs to oscillation mechanism/speed regulation mechanism and making functional for satisfactory performance complete all as specified and directed..
All as per item No.64.00 above,but for wall mounted fan 400 mm sweep including carrying out repairs to oscillation mechanism/speed regulation mechanism and making functional for satisfactory performance complete all as specified and directed.
Supply only capacitor 1.5 mfd, 240volts, 50Hz complete all as specified and directed.
Supply only capacitor 2.5 mfd, 240volts, 50Hz complete all as specified and directed.
Supply only capacitor 3.15 mfd, 240volts, 50Hz complete all as specified and directed.
Supply only ball bearing complete all as specified and directed. (Make:- SKF Cat No 6201/6202 or equivalent in NBC/NRB as approved)
Supply only ball bearing complete all as specified and directed. (Make:- SKF Cat No 6203/6204 or equivalent in NBC/NRB)
Supply only gun metal bush suitable for ceiling fan/Exhaust fan/Air circulator/wall mounted fan of any sweep/type complete all as specified and directed.
Supply only shackle clip assembly with rubber bush reel and nuts,bolts and washers suitable for ceiling fan of any sweep/type complete all as specified and directed.
Supply only down rod made of MS pipe medium grade 15mm dia of 600mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to down rod with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply only down rod made of MS pipe medium grade 15mm dia of 900 mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to down rod with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed..
Supply only copper conductor cable, PVC insulated, sheathed, flexible, multistranded,ISI marked, 1100 volts grade 3 core, 0.75 sqmm and including electric connection from ceiling fan to ceiling rose complete all as specified and directed.
Supply only copper conductor cable, PVC insulated, sheathed, flexible, multistranded, ISI marked, 1100 volts grade 3 core,1.50 sqmm and including electric connection from ceiling fan to ceiling rose complete all as specified and directed.
Supply only copper conductor cable, PVC insulated, sheathed, flexible, multistranded, ISI marked, 1100 volts grade 3 core, 2.50 sqmm and including electric connection from electric appliences and ceiling rose/distribution board complete all as specified and directed.
Supply only MS clamp made out of flat iron of size 25X6mm or equivalent including galvanised 'S' type hook, nuts, bolts and washers etc suitable for hanging of ceiling fan and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Cutting the existing surface wall of brick/stone masonary and making round hole at any height suitable for fixing 300 to 450 mm sweep exhaust fan including providing nut, bolt and washers after grouting in PCC including stainless steel jali of required size fixed in wooden frame to avoid insects, fixed to outer surface of wall and making good the disturbed surface complete all as specified and directed.
M&L for painting to ceiling fan complete body, blades & down rod etc of any sweep/make/model with two coat of synthetic enamel paint by using electric spray gun machine to match with existing colour after preparation surfaces including marking of MES Number with black paint complete all as specified and directed directed. (Note:-Painting work to be carried out after dismantling of ceiling fan)
M&L for painting to exhaust fan complete body, blade assembly,frame etc of 300 mm to 450 mm any sweep /make/model with two coat of synthetic enamel paint by using electric spray gun machine to match with existing colour after preparation of surfaces including marking of MES Number with black paint complete all as specified and directed . (Note:-Painting work to be carried out after dismantling of exhaust fan)
M&L for rewinding of ceiling fan motor of 1200 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing,including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed.
M&L for rewinding of ceiling fan motor of 1400 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing,including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed.
M&L for rewinding of exhaust fan motor of 250mm sweep to 300 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor fixing back and testing including removing burnt out copper winding wire complete all as specified and directed.
M&L for rewinding of exhaust fan motor of 380mm sweep to 450 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor fixing back and testing including removing burnt out copper winding wire complete all as specified and directed.
M&L for rewinding of air circulator fan motor 450 mm sweep to 600 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing,including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from air circulator fan motor complete all as specified and directed.
Taking down storage type water heater (Geyser) 25 Ltrs capacity of any make/model/type from existing wall after disconnecting of electric and water supply connections and keeping the same in safe custody for carry out repairs/replacement of unserviceable spare parts & components such as heating element, thermostat,pilot lamps with wiring,insulating glass wool, thermal cut out,pressure release valve,safety valve,aperature plate assembly etc and exmine water tightness of inner storage tank after cleaning and renewal of rubber washer/gasket and nut,bolts and washers etc and adjust to required range of thermostat control and assembling all parts/ accessories including fixing back in same location after connecting up of water & electric connections and testing for its satisfatory functioning complete all as specified and directed. Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only (ii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate of this item.
Taking down storage type water heater (Geyser) 50 Ltrs capacity of any make/model/type from existing wall after disconnecting of electric and water supply connections and keeping the same in safe custody for carry out repairs/replacement of unserviceable spare parts & components such as heating element, thermostat,pilot lamps with wiring,insulating glass wool, thermal cut out,pressure release valve,safety valve,aperature plate assembly etc and exmine water tightness of inner storage tank after cleaning and renewal of rubber washer/gasket and nut,bolts and washers etc and adjust to required range of thermostat control and assembling all parts/ accessories including fixing back in same location after connecting up of water & electric connections and testing for its satisfatory functioning complete all as specified and directed. Note:- (i) Spares will be measured and paid separately under relevant item of schedule as supply only (ii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate.
Supply only heating element 1.5 KW (ISI marked) cup type/thread type as required complete all as specified and directed.
Supply only heating element 2 KW (ISI marked) cup type/thread type as required complete all as specified and directed.
Supply only thermostat suitable for geyser suitable for 25/35/50 Ltrs capacity complete all as specified and directed.
Supply only thermal cut out suitable for any type of geyser complete all as specified and directed.
Supply only aperature plate assembly suitable for storage type water heater (geyser) 25 litre capacity complete all as specified and directed
Supply only aperature plate assembly suitable for storage type water heater (geyser) 50 litre capacity complete all as specified and directed
Supply only Inner tank (copper) suitable for geyser 25 Ltrs capacity of any type complete all as specified and directed.
Supply only Inner tank (copper) suitable for geyser 50 Ltrs capacity of any type complete all as specified and directed.
Supply only indication lamp (green/red) as required complete all as specified and directed..
Supply only 15mm dia PVC flexible pipe (heavy duty) both end socketed 450mm long for hot water complete all as specified and directed.
Supply only 15mm dia PVC flexible pipes (heavy duty) both end socketed 600mm long for hot water complete all as specified and directed.
Supply only 15mm dia PVC flexible pipe (heavy duty) both end socketed 450mm long for cold water complete all as specified and directed.
Supply only 15mm dia PVC flexible pipes (heavy duty) both end socketed 600mm long for cold water complete all as specified and directed.
S&F for 15 mm dia bib tap standard pattern of PTMT white colour high pressure screwed for iron GI pipe/fittings as in repair complete all as specified and directed.
Supply only 15 mm dia stop valve, cast copper alloy chromium plated with crutch handle screwed both ends for GI pipe/fittings complete all as specified and directed
M&L for painting to storage type water heater(Geyser) of capacity 25 litre of any make/type to complete external body with two coat of synthetic enamel paint by using electric spray gun machine to match with existing colour after preparation of surfaces including marking MES Number with black paint complete all as specified and directed. (Note:-Painting work to be carried out after dismantling of storage type water heater(geyser)
M&L for testing and checking of safety valve, thermostat, hot water pipe, etc of geyser at site (Geyser which is not under repair) till entire satisfaction of Engr-in-Charge duly signed by Engr-in-Charge, JE E/M and Contractor on Geyser Testing Register complete all as specified and directed.
S S ENTERPRISE
TAMALIKA ENTERPRISE
M/S RAJESH TRADING CO
M/S. ARUP KUMAR DEY
BARRACKPORE ELECTRONICS
M/S PAUL CONSTRUCTION
SHANKAR CONSTRUCTION CO
DAS ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .