| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.6 LAccepted-AOC | 1 | Accepted-AOC Awarded being the lowest tenderer | |
| 2 | 2₹27.8 L+₹1.4 L (5.43%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹34.1 L+₹7.8 L (29.4%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹34.9 L+₹8.5 L (32.2%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹35.7 L+₹9.3 L (35.3%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Oct 2019, 6:00 pmClosed
Garrison Engineer Naval Base
Garrison Engineer Naval Base Gandhigram Post Visakhapatnam
REPAIR AND REPLACEMENT OF INTERNAL ELECTRICAL FITTINGS FIXTURES DBS SUB MAIN WIRING AND CONNECTED EM WORKS AT J K L M NAUSAINIK VIHAR AREA AT DOLPHIN HILL AREA UNDER GE NB VISAKHAPATNAM
2019_MES_283970_1
GE(NB)/VIZ/TOKEN 59 of 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Visakhapatnam
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer Naval Base
₹1 L
Yes
13 Jun 2020
21 Sept 2019
19 Oct 2019
21 Sept 2019
18 Oct 2019
4 Oct 2019
Amount
M&L for point wiring with two runs of single core 1.5 Sqmm (nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore medium grade (ISI marked) Concealed/ Semi concealed / suface PVC conduit including flush type metal GI boxes for fixing modular switches, sockets, regulators etc. including provision of multistranded 1.5 Sqmm. copper conductor as earth wire connected to common earth dolly and earth in distribution board, including tee bend, elbows, junction boxes etc including taking down existing point wiring along with fittings and fixtures, of old UNSV items and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed.
All as per item No. 1.00 above but for One light point controlled by two way switch complete all as specified and as directed.
All as per item No. 1.00 above but for One 3 pin socket outlet 6 amps on independent board complete all as specified and as directed.
All as per item No. 1.00 above but for One 3 pin socket outlet 6 amps point on same board complete all as specified and as directed.
All as per item No. 1.00 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable as earth lead complete all as specified and as directed. [i] Note for Item No. 1 to 5 : MAKE :(i) CABLE : FINOLEX, PLAZA, POLYCAB/HAVELLS/GLOSTER/HARSH [ ALL ARE ISI MARKED FRLS CABLES ] (ii) PVC CONDUIT : AVON PLAST / GARWARE PLASTICS/ TENCOS LTD/KALINGA/FINOLEX / PRECISION [ ALL ARE ISI MARKED]. [ii] Note 2 : The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.
M&L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through existing surface / ceiling / concealed steel / PVC conduit along with 1 run of single core 10 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth will be measured as one length.
M&L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through existing surface / ceiling / concealed steel / PVC conduit along with 1 run of single core 6 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth will be measured as one length.
M&L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through existing surface / ceiling / concealed steel / PVC conduit along with 1 run of single core 6 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth will be measured as one length.
M&L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through existing surface / ceiling / concealed steel / PVC conduit along with 1 run of single core 4 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth will be measured as one length.
M&L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through existing surface / ceiling / concealed steel / PVC conduit along with 1 run of single core 2.5 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth will be measured as one length. Make of Cable : Havells/ Finolex/Polycab/ Plaza/ Gloster/ Harsh all are ISI marked and FRLS cables. [i] Note for Item No. 7 to 10 : Make of Conduit : AVON PLAST / GARWARE PLASTICS/ TENCOS LTD/FINOLEX / PRECISION/ KALINGA [ ALL ARE ISI MARKED ]
S&F in replacement Distribution Board, TPN, 8 way, Double door including taking down existing fittings and fixtures, old UNSV items and making good the disturbed surfaces to match with adjoining surface complete all as specified and as diretced complete all as specified and directed. Make : Indo Asian /Standard/Havells / C&S
S&F in replacement Distribution Board, TPN, 6 way, Double door including taking down existing fittings and fixtures, old UNSV items and making good the disturbed surfaces to match with adjoining surfacecomplete all as specified and as diretced complete all as specified and directed. Make : Indo Asian /Standard/Havells / C&S
S&F in replacement Distribution Board, TPN, 4 way, Double door including taking down existing fittings and fixtures, old UNSV items and making good the disturbed surfaces to match with adjoining surface complete all as specified and as diretced complete all as specified and directed. Make : Indo Asian /Standard/Havells / C&S
S&F in repairs Distribution Board, SPN 12 Way, Double door including taking down existing fittings and fixtures, old UNSV items and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Make : Indo Asian / Standard / Havells / C&S
S&F in repairs Distribution Board, SPN 8 Way, Double door including taking down existing fittings and fixtures, old UNSV items and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Make : Indo Asian / Standard / Havells / C&S
S&F in repairs Distribution Board, SPN 4 Way ,Double door including taking down existing fittings and fixtures, old UNSV items and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. Make : Indo Asian / Standard / Havells / C&S
S & F MCB SP 6 to 32 Amps, 240 Volts, B Curve, complete all as specified and as directed Make : Indo Asian Cat part No. 811008 to 811015[ Optipro] / STANDARD / HAVELLS / C & S cat part no:CSMBS1C6 to C32
S & F MCB SPN 6-32A Amps 240 Volts MCB C Curve , complete all as specified and as directed Make : Indo Asian Cat part No. 811027 to 811034[ Optipro] / STANDARD / HAVELLS /C & S cat part no:CSMBS1C6N to C32
S & F MCB SPN 40 Amps 240 Volts MCB C Curve , complete all as specified and as directed Make : Indo Asian / STANDARD / HAVELLS /’ C & S
S & F MCB, TPN 40 Amps 415 Volts, B Curve , complete all as specified and as directed Make : Indo Asian Cat part No. 811054 [ Optipro] / STANDARD / HAVELLS /C & S cat part no:CSMBS3C40N
S & F MCB, TPN 63 Amps 415 Volts , C Curve , complete all as specified and as directed Make : Indo Asian / STANDARD / HAVELLS / C & S
S & F MCB, TP 40 Amps 415 Volts , C Curve , complete all as specified and as directed Make : Indo Asian / STANDARD / HAVELLS / ’ C & S
S & F in repairs Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V complete all as specified and as directed. Make : Indo Asian / Standard / Havells / ’ C & S
Taking down ceiling fan any sweep from the site and S & F new parts in replacement of the defective parts such as shakle & clamps including, rubber bush, bolts, nuts & split pin (Chera Pin), washer etc. for ceiling fan and ensure proper inserting the quarter/ Split pin to hold the nut and bolt on fan downrod at fix position including servicing, oiling and greasing and re-fixing the ceiling fan / exhaust fan of any sweep again at existing site all as specified and as directed .
S&F in repair twin core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 0.75 sqmm complete all as specified and as directed.
S & Fix repairs of single core 1.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring complete all as specified and as directed. Make:Finolex/Havells/Gloster/Polycab/Plaza [ All are FRLS cables and ISI Marked ] Note :- Rate quoted are to be included for taking down the existing unservicable cable.
All as per item No. 26 above but of cable size 2.5 Sqmm size cable complete all as specified and as directed. Make:Finolex/Havells/Gloster/Polycab/Plaza[All are FRLS cables and ISI Marked ]
All as per item No. 26 above but of cable size 4 Sqmm complete all as specified and as directed. Make:Finolex/Havells/Gloster/Polycab/Plaza [ All are FRLS cables and ISI Marked ]
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. Make : Anchor/Cona/Havells/Bajaj
S&F in repairs ceiling rose surface bakelite 65 X 50mm two to three terminals complete all as specified and as directed. Make : Cona / Anchor / Legrand/MK
S&F in repairs bipin holder for 40 / 36 watt FTL fitting complete all as specified and as directed. Make : Anchor / Bajaj / Cona/MK
S&F in repairs Non retrofit CFL holder for 9/11/13W CFL light fittings complete all as specified and as directed. Make : Anchor/Cona/Havells/Bajaj
S&F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. Make : Anchor(Roma)/Legrand/MK
Supply and fix in repair fan capacitors of 2.5 Mfd complete all as specified and as directed. Make : Havells/USHA/TIBCON
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. Make : Anchor / Bajaj / Cona Note : Taking down of socket outlet included in taking down point wiring
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed. Make : Anchor / Bajaj / Cona Note : Taking down of socket outlet included in taking down point wiring
S&F in repair Switch socket combination 2 in1, 3 pin,5 Amps flush type,universsal complete all as specified and as directed. Make : Anchor / Bajaj / Cona
S&F in repair Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universsal complete all as specified and as directed. Make : Anchor / Bajaj / Cona
S&F in replacement Modular Fan regulator, 2 Module complete all as specified and directed. Make : ABB of model No. CPW2SFR5 or equivalent in Roma/MK/Legrand.
S&F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. Make: MK/Anchor (Roma)/ABB/Legrand
S&F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand
S&F in repairs Modular socket 6 Amp , 2/3 pin combined 2 module, complete all as specified and as directed. Make:Legrand/ MK/Anchor (Roma)/ABB
S&F in repairs Modular socket 6A /16A- 2/3 pin combined 2 module, complete all as specified and as directed. Make:Legrand/ MK/Anchor (Roma)/ABB
S&F in repair Modular white cover plate with frame, but 1 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand
S&F in repair Modular white cover plate with frame, but 2 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand
S&F in repair Modular white cover plate with frame, but 3 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand
S&F in repair Modular white cover plate with frame, but 4 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand
S&F in repair Modular white cover plate with frame, but 6 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand
S&F in repair Modular metal flush box, but 1/2/3 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand/Legrand
S&F in repair Modular metal flush box, but 4 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand/Legrand
S&F in repair Modular metal flush box, but 6/8 module complete all as specified and as directed. Make: MK/Roma/ABB/Legrand/Legrand
S & F in replacement switch piano flush type single pole 6 Amps AC 240V, 50HZ, complete all as specified and as directed. Make : Anchor / Bajaj / Leader / Cona
S & F in replacement switch piano flush type single pole 16 Amps AC 240V, 50HZ, complete all as specified and as directed. Make : Anchor / Bajaj / Leader / Cona
S & F in repair switch piano flush type single pole 6 Amps AC 240V, 50HZ, complete all as specified and as directed. Make : Anchor / Bajaj / Leader / Cona
S&F in repair bell push flush type, 6 amp 240 volts, complete all as specified and as directed. Make: Cona/Anchor/Legrand
S&F in repair Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed. Make : Legrand / Cona / Anchor / Bajaj
S&F in replacement two pole and earth Metal clad industrial plug & socket, 250V, 20A of Make Indo Asian Cat Pt No for Plug - 20A 2P+E, 230V AC (810386) and for Socket - 20A 2P+E, 230V AC (810390) or equivalent in Havells/HPL/Standard.
S&F in repairs for Residual Current Circuit Breaker TECHNO RCCB - 2 Pole 40 Amps, and Sensitivity of 30 mA complete all as specified and as directed . Make: Indo Asian. Cat Part No.811701 [ Optipro] Legrand/ HPL/Standerd/
S&F in replacement for Residual Current Circuit Breaker TECHNO RCCB - 2 Pole 40 Amps 100mA . Make: /Indo Asian. Cat Part No.811707 [ Optipro] / Legrand/ HPL/Standerd
S&F in replacement for Residual Current Circuit Breaker TECHNORCCB- 4 Pole, Sensititvity 40Amps 30 mA complete all as specified and as directed Make: /Indo Asian. Cat Part No.811719 [ Optipro] / Legrand/ HPL/Standerd
S&F in replacement for Residual Current Circuit Breaker TECHNO RCCB- 4 pole 40Amps and Sensititvity 100 mA Make: /Indo Asian. Cat Part No.811725 [ Optipro] / Legrand/ HPL/Standerd
S&F in replacement MCCB 415 Volt 16 KA , 4 Pole, 63 Amps Capacity complete all as specified and as directed . Make: /Indo Asian. Cat Part No. 830020 / Legrand/ HPL/Standerd/’ C & S
S&F in replacement MCCB 415 Volt 25 KA 4 Pole 100 Amps Capacity. Make: /Indo Asian. Cat Part No. 830052 / Legrand/ HPL/Standerd
S&F in replacement MCCB 415 Volt 25 KA 4 Pole 125 Amps Capacity. Make: /Indo Asian. Cat Part No. 830053 / Legrand/ HPL/Standerd/ C & S cat part no:CSMBS31SO125
S&F in replacement 3mm thick hylam sheet cover of size 6x4" for fixing switches, sockets regulator etc. complete all as specified and as directed.
S&F in replacement 3mm thick hylam sheet cover of size 6x6" for fixing switches, sockets regulator etc. complete all as specified and as directed.
S&F in replacement 3mm thick hylam sheet cover of size 10x8" for fixing switches, sockets regulator etc. complete all as specified and as directed.
S&F 3mm in replacement thick hylam sheet cover of size 12x10" for fixing switches, sockets regulator etc. complete all as specified and as directed.
Taking down carefully old and UNSV Single phase meter any type or capacity and making good the disturbed surface to match with the existing surfaces/walls etc all as specified and directed and S&F in replacement Single phase electronic meters 10-40 Amps, CT operated (LCD Display), 230 Volts totally tamper proof, with tamper and fraud detection and recording with snapshot, high accuracy and operation at very low load complete all as directed by Engr-in-Charge. Make : Benlo Cat Part No BESPLCD10-40 / Secure/CG.
Supply, lay, joint, test and commission of LT cable 1100 V grade, [ISI marked] FRLS XLPE insulated, Screened, PVC bedded, Galvanised strip or wire armoured and sheathed, Aluminium conductor Cable of size 3.5 Core, 70 Sq.mm including cable glands, lugs, jointing materials etc laid in trenches / floors / ducts complete all as specified and as directed. Make: Polycab / Universal / Nicco / Havells
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation , for shafts, wells, cess pits, manholes, pier holes etc of area not exceeding 10 Sqm on plan , and getting out in soft / loose soil, complete all as specified and as directed.
Removing Excavated soils to a distance exceeding 250 M and not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25cm thick with soils complete all as specified and as directed.
Supply and spreading clean dry sand as in cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and lay un reinforced precast concrete cable covers fonfirming to IS 5820-1970 class LV Type 2 Flat of size 230 x 150 x 70mm trenches as protection to cable complete all as specified and as directed.
Repairs to wall inbuild fixed distribution boar type sheet metal approximate szie (5 x2.5 x 0.5 Feet's) parts tinkering the parts and replacing fully corroded cover of panel board ( front cover) etc with appropriate gauges MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolts and by taking out all MCB's in the panel board and and painting the complete body with two coat of synthetic enamel paint over a coat of Zinc chrome primer and marking the Qtr No, Panel Board No in front side and proper fixing the all MCB's and legging in cable and control wire sheet metal screws metal screws all as specified and directed by engineer in Charge.
Repairs to existing Panel board indoor type sheet metal approximate szie (5 x1.5 x 1.5 Feet) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauges MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolts in MCBs and proper legging in cable and control wire sheet metal screws and painting the complete body with two coats of synthetic enamel paint over a coat of Zinc chrome primer and marking the Qtr No, Panel Board No in front side and complete all as specified and as directed by Engineer in charge and tested on completion.
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on Note : The rate is inclusive of necessary earth work, RFR and removal, PCC Chamber RCC Cover and reinforcement .
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip 25 x 4mm (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal, PCC Chamber RCC Cover and reinforcement .
M&L for Earthing complete with copper earth plate electrode 600x600x3.15 mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 20 x 3.15 mm (beyond 7.5m Main earthing lead from earth electrode to test point shall be measured and paid separtelly) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel with 15 mm dia light grade for watering and for protection of earth electrode 32/40 mm dia GI pipe and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 mtr from the earthing place all as specified and directed by E-in-Charge. Note : The rate is ilnclusive of necessary earth work, RFR and removal, PCC Chamber RCC Cover and reinforcement .
S&F Aluminium strip of size 25 x 3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps,nuts,bolts and hylam sheet block complete all as specified and as directed.
S&F in replacement GI strip of size 25x4mm for lightning conductor laid in trench / floor including necessery clamps, nuts, bolts and hylam sheet block complete all as specified and as directed.
S&F in replacement Copper strip of size 20 x 3mm for lightning conductor/equipment laid in trench/floor including necessery clamps,nuts,bolts and hylam sheet block complete all as specified and as directed.
S&F in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long and fixed complete all as specified and as directed.
S&F in replacement Air termination, single pointed copper rod 12mm dia and 300mm long and fixed complete all as specified and as directed.
Fixing in repairs to old existing Aluminium strip/copper strip of any size with saddles and fixing screws etc (same existing ) for roof conductor and down conductors above ground.
S&F in repairs Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
KANAKAJYOTHI ENTERPRISES
KIRON ENGINEERING CORPORATION
SRIKRISHNACONSTRUCTIONS
SAMPATH ENTERPRISES
Mavee Syndicate
SOHAN ENGINEERING ASSOCIATES
SONI ENGINEERS CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .