Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.0 CrAccepted-AOC | ₹15.0 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹15.8 CrRejected-AOC | ₹15.8 Cr | 2 | Rejected-AOC L2 |
Tender Value
₹14.1 Cr
EMD Value
₹5 L
Closing Date
10 May 2023, 3:00 pmClosed
SUPERINTENDING ENGINEER
PH CIRCLE, KWA, MALAPPURAM
JJM-WSS to Nannambra GP-Package II-Design Construct 9MLD WTP with OHSR sump cum pump house Compound wall including supply and erection of RW and CW pump set with transformers and allied works-Pipeline Work
2023_KWA_573557_1
SE/PHC/MPM/12/2023-24
Open Tender
Civil Works - Water Works
300 days
Nannambra
Refer tender documents
8 documents required · 8 mandatory
₹16,540
₹5 L
PH CIRCLE, KWA, MALAPPURAM
15 May 2025
27 Apr 2023
11 May 2023
27 Apr 2023
10 May 2023
29 Apr 2023
27 Apr 2023 - 29 Apr 2023
29 Apr 2023
Amount
9.00 MLD WTP with 25.00 LL OHSR
2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
2.33.2:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.9.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (requiring blasting)
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.2:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-35 grade concrete instead of M-25 grade BMC/RMC. (Note: Cement content considered in M-35 is @ 350 Kg/cum).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.2.1:15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
11.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
11.4:52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
13.71:Lettering with black Japan pint of approved brand and manufacture
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.
OD148826/2022-2023:Supplying and providing lightening conductor to the tank of appropriate places and providing suitable earthing as per IS2309-1989 code
OD148827/2022-2023:Supplying and fixing water level indicator (float and board type) with all accessories including cost, conveyance and labour charges etc.. Complete as per the direction of departmental officers at site
OD148828/2022-2023:Supplying and fixing CI Vent cowl with providing moisture proof arrangements
Electro Mechanical Work of WTP including 1 year O& M
OD137375/2022-2023:Supply erection of Suitable capacity electric motors with Flash Mixer arrangement as per design including all related electrical works etc compete
OD137411/2022-2023:Supply and erection of Flocculation arrangement with suitable capacity motors and all allied works as per design and as directed by the departmental officers at site
OD137480/2022-2023:Supply erection of Clarifier motor assembly and allied works as per design
OD137775/2022-2023:Providing Pipe Gallery works including pipe works related to filter bed, wash water tank inter connection work inlet and outlet arrangements of filter bed, air blower pipe work with supply of suitable capacity Blower etc complete
OD137856/2022-2023:Supply laying Filter media of specified size as per design of anthracite, including providing filter nozzles and allied works
OD148809/2022-2023:Supply erecting of Single girder EOT ( Electric Over head travelling )Crane to carry a weight up 1.5 MT and as per the directions and approvals of departmental officers
OD148806/2022-2023:Supply of lab equipment with reagents used for chemical testing as below specified List of Laboratory and safety equipments to be supplied and installed 1. Jar test Apparatus with 4 Jar - 2 Nos. 2. Microprocessor based pH meter -2 nos. 3. Microprocessor based Turbidity Meter -2 no. 4. Electronic Weighing balance with accuracy ±0.001g -1 Nos 5. Bacteriological test kit. -2 nos. 6. Test tubes -24 nos. 7 Porcelain dishes. -6 nos 8. Chlorine test kit. -4 nos. 9. Autoclave. -2 nos. 10. Gas filled fire extinguishers, buckets, and masks etc .- As per rules. 11. Glass rods. -6 nos. 12. Incubator.- SS inner, 45x45x45 cm size -2 nos. 13. Conical flask.100 ML -6 nos. 14. Conical flask 250 ml -6 nos 15. Standard flask Volumetric ,i/c stopper borosilicate glass 1000 ml -3 nos 16. Standard flask Volumetric ,i/c stopper borosilicate glass 500 ml -3 nos 17. Standard flask Volumetric ,i/c stopper borosilicate glass 250 ml -3 nos 18. Standard flask Volumetric ,i/c stopper borosilicate glass 100 ml -4 nos 19. Reagent bottle , plain narrow mouth with i/c stopper-1000ml -3nos 20. Reagent bottle , plain narrow mouth with i/c stopper-250 ml -3nos 21. Reagent bottle , plain narrow mouth with i/c stopper-125 ml -3nos 22. Reagent bottle , plain narrow mouth with i/c stopper-100ml -3nos 22. Beaker low form graduated with spout borosilicate glass 1000ml -6nos 22. Beaker low form graduated with spout borosilicate glass 500ml -3nos 22. Beaker low form graduated with spout borosilicate glass 250ml -3nos 22. Beaker low form graduated with spout borosilicate glass 100ml -3nos 23. Water still. -6 nos. 24. Pipette graduated complete delivery borosilicate glass 10 ml -6 nos 25. Pipette graduated complete delivery borosilicate glass 5 ml -6 nos 26. Pipette graduated complete delivery borosilicate glass 1 ml -3 nos 27. Burette, rot flow, screw threaded stop cock graduated borosilicate Glass 50 ml with stand and clamp -2 nos 28. Measuring cylinder with hexagon base and spout ambient stain Graduated borosilicate glass 500 ml -3 nos 29 …do..do.. 100 ml -3 nos 30. Spatula. -6 nos. 31. Ton guy. -6 nos. 32. Laboratory reagents -As required.
OD148807/2022-2023:Supply and fixing 1 Ton capacity chlorine cylinder as per standard specification
OD148808/2022-2023:Providing and fixing required capacity chlorinator including all fittings charges. Chlorinator shall confirm clause 8.7.2 of CPHEEO Manual.
OD137875/2022-2023:Supply erection of all sanitary and plumbing works related to the filter house bath rooms including septic tank at suitable locations and direction of departmental officers. Detailed scope of as per Vol II scope of work is to be followed.
OD137918/2022-2023:Providing Electrification works of store building, Filter house, pump houses, yard lighting including supply of all materials and labor with all approvals from electrical inspectorates etc. complete as per IE rules. Detailed electrical drawings shall be prepared by the contractor and got approved from the concerned.
OD137930/2022-2023:Operation and Maintenance of plant for one year including supply of chemicals for the water treatment plant, technicians with all Operating staff
OD220679/2022-2023:Wash water pump sets with arrangements, airblowers, other mechanical equipments, motors, etc
Tank inter connection work - 25 LL OHSR
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged
18.73.4:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :250 mm dia Ductile Iron Double Flanged
18.73.6:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :350 mm dia Ductile Iron Double Flanged
18.73.7:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :400 mm dia Ductile Iron Double Flanged
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.30.6:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe
18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe
18.30.9:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:400 mm diameter pipe
100.31.2.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class II.
100.31.2.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class II.
100.31.2.9:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 400mm diameter, Class II.
100.31.2.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class II.
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
Construction of compound wall and Gate at WTP Site
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.9.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (requiring blasting)
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
16.18.1:Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for serarately) :- Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire
16.19:Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
10.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
Internal and Access road to WTP Land
3.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
4.7.2.B:Water Bound Macadam Sub-base/base 2) WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. (B) By Mechanical Means
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)
Supply, erecting, testing , commissioning of Raw water, Clear water Pump sets and Transformers
OD273432/2022-2023:Supplying a complete integrated FCMA/soft starter panel capable of operating the motor (3 nos 100 HP VT Pump sets, 3phase
OD141068/2022-2023:supplying an electro -magnetic flow meter conforming to protection level of IP 68 for flow sensor and IP - <br>67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit .The flow meter should<br>have the housing( flow sensor ) to be made of SS 304/carbon steel with anti corrosive protection and<br>inside liner to be made of Hard rubber /ne0 prone all conforming to drinking water standards .The flow<br>meter should be coupled with HART for data acquisition and transfer trough GSM. The manufacturers<br>should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty<br>provisions- For 300 mm dia pipe
OD141948/2022-2023:supplying an electro -magnetic flow meter conforming to protection level of IP 68 for flow sensor and IP -<br>67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit .The flow meter should<br>have the housing( flow sensor ) to be made of SS 304/carbon steel with anti corrosive protection and<br>inside liner to be made of Hard rubber /ne0 prone all conforming to drinking water standards .The flow<br>meter should be coupled with HART for data acquisition and transfer trough GSM. The manufacturers<br>should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty<br>provisions- For 400 mm dia pipe
OD141256/2022-2023:11KV 630 A 350MVA ABSFU master trip relay including KSEB HT TOD metering provision with CTs, PT & TOD meter
OD141255/2022-2023:KSEB DP to Meter & Transformer cable - 3 X 300 SQ.MM H.T. XLPE CABLE
OD141257/2022-2023:Indoor end termination of 3 x 300 sq.mm XLPE cable to the HT Switch and to the transformer
OD141258/2022-2023:Outdoor end termination of 3 x 300 sq.mm XLPE cable
OD141588/2022-2023:Supply, erection, testing and commissioning of 315 KVA, 11KV/433V. 3phase, 50Hz. ONAN cooled , indoor type copper wound distribution transformers with HV and LV side cable end box arrangements, off load tap changer with 5 tap positions having +5% to -5% variations in 2.5% steps including first filling of oil etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards
OD141589/2022-2023:PANEL BOARD ( M.S.B. ) INCOMER : 630 A 4 P ACB Microprocessor draw-out type, Standby low set E/F relay with CT at neutral earthing strip. 1 NO. Multifunction Meter -1No Phase indication lamp - 3Nos 630A Al Bus bar - 1set OUTGOINGS : 200A 4P MCCB -4Nos 100A 4P MCCB -1Nos 63A 4P MCCB -2Nos
OD141591/2022-2023:Transformer to MSB 3.5 CX 400 Sq mm Aluminium armoured Cable
OD141593/2022-2023:MSB to 120Hp motor 3.5 CX 240 Sq mm Aluminium armoured Cable
OD141598/2022-2023:MSB to 60Hp motor 3.5 CX 70 Sq mm Aluminium armoured Cable
OD141604/2022-2023:MSB to 15Hp motor 4 CX 16 Sq mm Aluminium armoured Cable
OD141608/2022-2023:2 CX 4 Sq mm Aluminium armoured Cable
OD141610/2022-2023:10 CX 2.5 Sq mm Copper Cable
OD141618/2022-2023:3.5 CX 400 Sq mm Aluminium armoured Cable
OD141622/2022-2023:3.5 CX 240 Sq mm Aluminium armoured Cable
OD141623/2022-2023:3.5 CX 70 Sq mm Aluminium armoured Cable
OD141627/2022-2023:4 CX 16 Sq mm Aluminium armoured Cable
OD141632/2022-2023:2 CX 4 Sq mm Aluminium armoured Cable
OD141634/2022-2023:10 CX 2.5 Sq mm Copper Cable
OD141636/2022-2023:Providing efficient plate earthing using 1200 x 1200 x 10 mm CI plate earth electrode conforming to IS 3043 complete with necessary earth pit chamber, C.I. Cover, G.I. Pipe, connections including filling the pit with charcoal and salt, including excavation, refilling and all connected civil works
OD141641/2022-2023:G.I. Strip 32 x 6 mm for earthing
OD141658/2022-2023:Copper Strip 25 x 3 mm for earthing
OD273430/2022-2023:For soil resistivity measurements preparation of drawing and fees towards Electrical Inspectorate,obtaining necessary approval from Electrical Inspectorate etc and for misc items
OD273429/2022-2023:Supply and providing the safety items approved by Kerala Electrical Inspectorate and relevant standards at WTP & Intake
MIDLAND ENGINEERING AND CONTRACTING COMPANY
Bidder Name
Fakrudheen ali ahammed
MIDLAND ENGINEERING AND CONTRACTING COMPANY
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid