Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC HOUSE NO 6 NARENDRA GARDEN PO JAGAMARA PS KHANDAGIRI DIST KHORDHA PIN 751030 | KHORDHA | KHORDHA | ODISHA | 751030 | ₹7.7 L | L1 | Accepted-AOC The bidder had quoted lowest rate among the qualified bidder so that the work has been awarded to him |
| 2 | L2₹8.1 LRejected-Finance B 35 CHANDAKA INDUSTRIAL ESTATE PATIA B 35 CHANDAKA INDUSTRIAL ESTATE PATIA INFOCITY SQUARE BHUABNESWAR ORISSA 751024 | KHORDHA | ODISHA | 751024 | ₹8.1 L | L2 | Rejected-Finance The bidder has not furnished the Registration Certificate as per Clause 10 C of DTCN |
| 3 | L3₹8.3 LRejected-AOC | ₹8.3 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹8.3 LRejected-AOC AT MADHUSUDANPUR PO BARANGA DIST CUTTACK | ₹8.3 L | L4 | Rejected-AOC Rejected |
| 5 | L5₹8.9 LRejected-AOC | ₹8.9 L | L5 | Rejected-AOC Rejected |
Tender Value
₹9.7 L
EMD Value
₹9,744
Closing Date
21 Jan 2026, 5:00 pmClosed
Er.Soumya Ranjan Dwibedi
O/o the S E R and B Division Puri
Provision of firefighting system such as automatic fire detection system (smoke detector, beam detector) Fire extinguisher and electrical renovation to District Record Room Puri
2026_EICCL_124570_1
SERANDB PURI-55/2025-26
Open Tender
Electrical Works
30 days
Puri
2 documents required · 2 mandatory
₹4,000
₹9,744
Yes
30 Apr 2026
15 Jan 2026
22 Jan 2026
15 Jan 2026
21 Jan 2026
15 Jan 2026
15 Jan 2026 - 19 Jan 2026
AUTOMATIC FIRE DETECTION SYSTEM Supplying, installation, testing and commissioning of Addressable Multi Detector(Smoke cum Heat) complete with base and isolator as per direction of Engineer-in-charge.
Supplying, installation, testing and commissioning of Addressable Beam(Infrared) Detector including Transmitter & Receiver, complete with base and isolator as per direction of Engineer-in-charge.
Supply and installation of visual type response indicators with LED indicating lamp, housed in suitable MS enclosure with acrylic cover fixed in flush with wall to operate in conjunction with smoke/Heat detectors operating on 24 VDC installed above the false ceiling or below the false floor, complete with all accessories and fixing materials as required and as directed by Engineer-in-charge.
CONTROL PANEL Supply,Installation, testing and commissioning of Microprocessor based 4 Loop Addressable Main Fire Alarm Control Panel with LCD display, Integral System Power Supply Unit including Battery Charger with 12 volt , 7A Battery in all respects, mounting chasis & lockable type Hinged Door.(Honeywell/GST) as per direction of Engineer-incharge.
MCP Supplying, installing ,testing and commissioning of break glass type Manual call point . The Manual call point with monitor module shall be single stage type with all accessories and suitable sinages complete., the Manual call point shall be as per technical specification. and shall be of EN and LPCP listed.
Electronic Hooters Supplying, installing ,testing and commissioning of Hooter Cum Strobe at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication. With Control Module. The Hooter cum Strobe with Control Module shall be flush or surface mountable type with all accessories etc., complete and as per technical specification. The devices shall be of EN and LPCP listed (Make: Bosch or Equivalents)
Wiring Supplying and drawing of 2X1.5 sq.mm PVC insulated PVC Sheathed FRLS cable in the existing surface/ recessed conduit with all accessories as per direction of Engineer-in-charge.
Supply, delivery and laying of following sizes of Steel Conduit in surface/ in recess alongwith other accessories and 18 swg GI wire complete for Fire Alarm wiring including painting as required and as per direction of Engineer-in-charge. 20mm dia
25mm dia
Supplying, installing and commissioning of ISI ABC Powder 4 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type,Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax)
Supplying, installing and commissioning of CO2 Type 4.5 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax)
Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
Re-wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked and 1.5 sq.mm FR PVC insulated copper conductor single core multistrand copper conductor in existing recessed PVC/STEEL conductor including dismantling as required. Group-A
Group-B
Group-C
Supply ,installation, testing and commissioning of main switches (IS 13940 part-3/1993) of following capacity on existing surface / wall mounting and completer with HRC fuse links, interconnections, earthing , etc as required as per direction of Engineer-in-charge. (Make- HPL/ Anchor/ RK/ Siemens/L&T/C&S) 63Amp ICDP main switches with MS board
Supply and fixing of 8way, SPN DD DB BOX. .(Make-Havells/ C&s/ L&T)
Supply and fixing of 6Amp to 32A rating 240 V/415 V "C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make- Havells/ L&T/ C&S) 6 to 32 SP MCB
32 DP MCB
Supply and drawing of following sizes FR PVC insulated single core multistrand copper conductor in existing surface/ recessed/ STEEL / PVC conduit as required. 2 X 1.5sqmm +1 x 1.5sqmm (3 X 1.5sqmm)
2 X 2.5sqmm +1 x 1.5sqmm
2 X 4sqmm + 1 x 1.5sqmm
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 1.97 MB
Tendernotice_1.pdf
PDF • 1.29 MB
BOQ_575817.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid