Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.4 LAccepted-AOC NEAR EAST WEST PUBLIC SCHOOL SHAHABAD GATE RAMPUR U P | L-1 | Accepted-AOC Work Awarded | |
| 2 | L-2₹24.5 L+₹9,912.50 (0.41%)Rejected-Finance WARD NO 04 SUNHARI KICHHA U S NAGAR | CHAMOLI | UTTARAKHAND | 246401 | L-2 | Rejected-Finance Due to higher rate | |
| 3 | Rejected-Technical WARD NO 3 OLD BANGALI COLONY KICHHA U S NAGAR | - | Rejected-Technical Not found ok |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
24 Feb 2025, 12:00 pmClosed
Superintending Engineer
Electricity Distribution Circle, Rudrapur
Replacement of damaged conductor of 11 KV line (Branch lines) by ACSR Dog conductor and erecting of new poles in 11 KV Danpur Feeder emanating from 33/11 KV S/s Danpur under EDD-II Rudrapur
2025_UPCL3_79997_3
EDC(USN)42/2024-25
Open Tender
Electrical Works
Item Rate
90 days
Danpur Rudrapur
Pl. refer tender documents
4 documents required · 4 mandatory
₹1,180
EE ETD Rudrapur
₹75,000
2 Aug 2025
17 Feb 2025
25 Feb 2025
17 Feb 2025
24 Feb 2025
17 Feb 2025
Amount
Annexure-A (LABOUR CHARGES)
Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual.
Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all types of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work.
Fixing, tightening and nozzling of stay with pole and stay rod on required tension as per RESPO manual in 11 KV Line
Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all types of soil including proper dressing of sides and ramming of bottom including etting out the excavated soil and disposal of surplus excavated soil as directed complete work.
Erection of PCC single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual.
Erection of SP-55 single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual.
Grouting of pole in size 0.45x4.45x1/9 of the support in CC ratio 1:4:8(1 cement:4 graded stone 20 mm niminal size: 8 coarse sand) block including cost of cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, levelling as per RESPO cnstruction manual.
Muffing of poles size 0.45x0.60 cm radius with 1:3:6(1 cement:3 coarse sand :graded stone 10 mm nominal size) block size 45 cm height from ground level including cost of cement, stone and sand etc.
Dismantling of existing HT line. including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store(ACSR Weasel).
Painting of SP-55 pole with angle and channel and all steel part by one coat of Red Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level.
Fixing of triangular type bracket on 11 KV line.
Laying, Spreading, Stringing and sagging of 11 KV / 33 KV line in 3 phase (3 Phase 3 wire) of ACSR Dog as phase wire with G.I. earth wire complete including fixing of all accessories in 3 Nos. conductor in parallel with binding and jumpering as per profile and profile and sagging chart.
Route cleareance by cutting of tree branches / proning, loping and chopping of trees for L.T., 11 & 33 KV line.
Cartage of PCC Poles from store centre to construction site with loading, unloading at both points and proper stacking.(Distance 21- 50 Km)
Cartage of ST pole SP-55 Poles from store centre to construction site with loading, unloading at both points and proper stacking.(Distance 21-50 Km)
Cartage of other material (other than poles) by vehicle from Store Center to nearest construction site Store including loading and unloading at both ends(distance 21-50 Km)
Headload cartage of PCC Pole from road to site(distance 0-1 Km)
Headload cartage of SP-55 Pole from road to site(distance 0-1 Km).
Head load cartage of small material(distance 0-1 Km).
Straightening of Tilted Poles of ST Pole SP 55.
Straightening of Tilted Double Pole 11 KV Structure.
Fixing, tightening and nozzeling of stay with pole and stay set on required tension.
Dismantling & Rejumpering of conductor.
Replacement of 11 KV Pin Insulator.
Replacement of 11 KV Disc Insulator.
Erection of Danger Board with Clamp
Back Carriage of Scrap Material
Annexure-B (SUPPLY ITEMS)
Supply of X-Arm clamp for ST Pole SP-55 with N/B
Supply of F Clamp
Supply of Stay Clamp for SP-55 with Nut & Bolt
Supply of stay insulator
Supply of danger Board with GI clamp Bolts & Nuts
Supply of PG Clamp dog to dog
Supply of Stone Pad 300x300x75 mm
MANRAJ ELECTRICAL & INFRASTRUCTURE (BID ID -362049)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .