GENERAL-Repairs to damaged Transformer at ITI Malayinkeezh, Thiruvananthapuram.-Repairs to USS-HT-Electrical-Work
2026_PWD_865738_2
ESDT/ET-91/2026-27
Open Tender
Electrical Works
Percentage
120 days
PWD Electrical Sub Division Tvpm
please refer tender documents
6 documents required · 6 mandatory
₹805
₹9,110
24 Aug 2026
24 Aug 2026
5 Sept 2026
24 Aug 2026
3 Sept 2026
24 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | OD215000/2025-2026:Supply installation testing and commissioning of suitable size 3 Nos Current transformer Rating 10/5A, Accuracy class 0.2S, 10VA IL 12/28/75 kV as per IS 2705 and one Number PTs (, Rating 11kv/110 volt, Accuracy class 0.2, 20VA, IL 12/28/75 kV as per IS 2705(or suggested by KSEB) including Removing existing CT & PT, fixing new CT & PT, changing all bus bars, bus bar links, Hole punching, bending, drilling etc, complete re- wiring for TOD meter & CT/PT etc as per the direction of Engineer In charge. | - | each | 1,21,670 | - |
| 1.002 | OD215002/2025-2026:Conveying the CT&PT to nearby TMR Division for testing and taking back to site including loading and unloading charges necessary fees etc as required | - | each set | 6,969 | - |
| 1.003 | OD215006/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded 2.5 Sq.mm single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. | - | metre | 68.69 | - |
| 1.004 | OD215003/2025-2026:Fee to be remited to KSEB/ELECTRICAL Inspectorate Department (Actual amount incurred for the above items will be reimbursed on production of original documents) | - | each | 1 | - |
| 1.005 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm | - | metre | 172.91 | - |
| 1.006 | OD214997/2025-2026:Supply and replacing of Door locking system in the existing USS | - | each | 3,357.31 | - |
| 1.007 | OD215005/2025-2026:Providing and fixing Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia in existing panel and giving connection complete | - | each | 106.58 | - |
| 1.008 | OD215004/2025-2026:Supply and providing 2.5 mm thick, 11 kV, Synthetic elastomeric fire retardant insulating sheet | - | sqm | 1,960.37 | - |
| 1.009 | OD215590/2025-2026:Supply and providing of 11KV 10A HRC in place of existing fusible HRC fuse. | - | each | 9,236.78 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
mom1MAIN.pdf
Additional Documents • 0.73 MB
BOQ_1466912.xls
BOQ • 0.33 MB
viewsbd.pdf
Additional Documents • 1.63 MB
specialconditionsmodified.pdf
Additional Documents • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].