| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 CrAccepted-AOC ATHWAJAN SRINAGAR 191101 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 191101 | ₹19.6 Cr Quoted ₹20.1 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹20.3 CrRejected-AOC | ₹20.3 Cr | L2 | Rejected-AOC Other Than lowest |
| 3 | L3₹22.4 CrRejected-AOC PROP ZISHAN ALI ADARSH NAGAR NEW BUS STAND RAMGARH CANTT RAMGARH | ₹22.4 Cr | L3 | Rejected-AOC Other Than lowest |
| 4 | L4₹24.8 CrRejected-AOC | ₹24.8 Cr | L4 | Rejected-AOC Other Than lowest |
Tender Value
Refer Docs
EMD Value
₹12.3 L
Closing Date
12 Jan 2021, 6:00 pmClosed
Chief Engineer 31 Zone
HQ CE 31 Zone Pin 914631 C/o 56 APO
COMPLETION OF INCOMPLETE WORKS FOR CONSTRUCTION OF OTM ACCN FOR FIELD WORKSHOP AT PATTAN
2020_MES_383025_3
800110/2020/ /E8
Open Tender
Civil Works
750 days
Pattan
As per NIT
10 documents required · 10 mandatory
₹3,000
GE 969 EWS
₹12.3 L
Yes
20 Jan 2021
22 Dec 2020
14 Jan 2021
22 Dec 2020
12 Jan 2021
25 Dec 2020
22 Dec 2020 - 5 Jan 2021
Amount
Notes: (i) Please refer Schedule 'A' Notes given on serial page No. 23 to 29 of tender documents. (ii) Sch ‘A’ Part-I (Sec-I), Part-I (Sec-II), Part-III (Sec-II), Part-IX (Sec-II), Part-X (Sec-II), Part-XI (Sec-II), Part-XII and Part-XIII is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
SCHEDULE 'A' PART-I (SEC-I): LIST OF WORKS FOR BUILDING WORKS
Construction of block of Single Living Accn for 04 Offrs (Maj & above) with Servant Qrs 03 Nos incl garrages (03 Nos) with ramps (D/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of Single JCO Living Accn for 03 JCOs (D/S) framed construction with brick masonry panel walls complete all as specified and shown on drgs.
Construction of block of Single JCO Living Accn for 04 JCOs (D/S) framed construction with brick masonry panel walls complete all as specified and shown on drgs.
Construction of block of JCO's Mess (Club) for 11 to 15 JCOs (S/S) in RCC framed construction, brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of Cook House and Dinning Hall (S/S), framed construction with brick masonry panel walls complete all as specified and shown on drgs.
Construction of block of Religious institute (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of OR institute (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of Tradesman Shop (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Dhobi Ghat (02 Stones), complete all as specified and shown on drgs.
Construction of block of Drying & Ironing Room (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Alarm post complete all as specified and shown on drgs.
Construction of Repair Bay with Inspection Pit (S/S) framed construction with brick masonry panel walls, ramps with toe wall, complete all as specified and shown on drgs.
Construction of Washing Platform, complete all as specified and shown on drgs.
Construction of Ramp with Stone masonry, complete all as specified and shown on drgs.
Construction of block of Storage Accn for MT store, lubrication oil grease store and petrol store (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of R & I office with Tech Office (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Incinernator in brick masonry, complete all as specified and shown on drgs.
Construction of Meter & Switch Room (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Static Water Tank on 50 KL capacity, complete all as specified and shown on drgs.
Construction of Flag Staff with base, complete all as specified and shown on drgs.
Construction of Garbage Bin in brick masonry, complete all as specified and shown on drgs.
Construction of Workshop (Main) with store sections and 02 Nos Inspection pits (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Workshop for 'B' Vehs with store sections and 02 nos Inspections pits (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of Telecommunication Instruments (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Ancillary Shop for welder, painter & turner (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Ancillary Shop for Electrician (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of Ancillary Shop for Carpenters and Upholster (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of Battery Charging Shop (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of servicing bay including Inspection Pit (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of Tech Library (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of Gate Office (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of block of CHS Plant Room with duty room (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Construction of transformer shed as per TD Drg No.CESZ/TD/1110/2011, complete all as specified and shown on drgs.
SCHEDULE 'A' PART-I (SEC-II): LIST OF WORKS FOR BUILDING WORKS
Completion of incomplete works for Construction of block of Single Living Accn for 02 Hav & 126 ORs (D/S) in RCC framed construction with brick masonry panel walls, built-in Steel Lockers and Book Shelf for each Hav/OR, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Office & Adm Bldg along with tool & expense store and Technical Training Lecture Room (D/S), framed construction with brick masonry panel walls complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Guard House and Ancillaries including Armouries & Explosive Store (S/S) framed construction with brick masonry panel walls, Ramp 02 Nos with toe walls, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Garrage for Light Vehicles and Motor Cycle including MT Drivers Standing & Changing Room (S/S) framed construction with brick masonry panel walls, ramps with toe wall, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Garrage (block of 06) for Heavy Vehicles (S/S) ( Block No-1 ) framed construction with brick masonry panel walls, ramps with toe wall, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Garrage (block of 06) for Heavy Vehicles (S/S) ( Block No-2 ) framed construction with brick masonry panel walls, ramps with toe wall, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Garrage (block of 06) for Heavy Vehicles (S/S) ( Block No-3 ) framed construction with brick masonry panel walls, ramps with toe wall, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Garrage (block of 05) for Heavy Vehicles (S/S) framed construction with brick masonry panel walls, ramps with toe wall, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of storage accn with (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Open Garrage for Adm Block (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of Radar Shop (Dust proof & AC) with Office Room (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of Recuperator Room (Dust proof & AC) (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Armament shop for medium Guns (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
Completion of incomplete works for Construction of block of Armament shop for Mountain Guns & Field Guns (S/S) framed construction with brick masonry panel walls, complete all as specified and shown on drgs.
LUMPSUM PRE-PRICED SCHEDULES OF WORKS
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 30
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-III (SEC-I) brought forward from serial page No. 32
Lump sum price worked out by the contractor for COVERED PASSAGE WORKS listed in Schedule 'A' Part-IV brought forward from serial page No. 33
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 35.
Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARDSTANDING WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 38
Lump sum price worked out by the contractor for PROTECTIVE WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 39
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 40
Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS as listed in Schedule 'A' Part-IX (SEC-I) brought forward from serial page No. 42
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-X (SEC-I) brought forward from serial page No. 45
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-XI (SEC-I) brought forward from serial page No. 49
Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLING OF BUILDINGS as listed in Schedule 'A' Part-XIV brought forward from serial page No. 50
Lump sum price worked out by the contractor for SITE CLEARANCE WORKS as listed in Schedule 'A' Part-XV brought forward from serial page No. 51
SCH 'A' PART-III (SEC-II) INTERNAL ELECTRIFICATION WORKS
Fluorescent tube light fittings T-5, 1x28 watt, 230 V, surface/pendant mounted type, epoxy powder coated CRCA sheet housing complete with tube-01 No, lamp holders with electronic ballast having PF not less than 0.9, connector block etc, Complete with all accessories prewired and including connecting up with three core twisted flexible copper conductor cable with suitable size, complete all as specified and directed.
CFL light fitting 1x15 watt 230V wall mounting decorative polycarbonate fitting with CFL 15W model City 1 with retrofit complete with accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50Hz, complete all as specified and directed. Make :- Havells Cat Part No LHDL02160099/CG/Bajaj/Philips
Retrofit type 1x18 watt CFL having PF not less than 0.9, with all accessories complete all as specified and directed.
Telephone socket with top connector with suitable size of module for fixing arrangement, complete all as specified and directed.
TV Socket outlet single with suitable module, complete all as specified and directed
Sheet metal enclosure vertical type factory made, DB double door (VTPN) factory made having provision for FP MCCB upto 200 Amps as incomer, 415 Volts, triple pole and neutral 4 way with 200 Amps rated bus bar, complete all as specified and directed.
Sheet metal enclosure vertical type factory made, DB double door (VTPN) factory made having provision for FP MCCB upto 200 Amps as incomer, 415 Volts, triple pole and neutral 8 way with 200 Amps rated bus bar, complete all as specified and directed.
Sheet metal enclosure TPN factory made, DB double door (TPN) factory made having provision for FP MCCB upto 200 Amps as incomer, 415 Volts, triple pole and neutral 8 way with 200 Amps rated bus bar, complete all as specified and directed.
Supply and fixing MCCB four pole 415V, 50 HZ, 16KA of rating (63A) with adjustable thermal setting, complete all as specified and directed.
Supply and fixing MCCB four pole 415V, 50 HZ, 25KA of rating (150A) with adjustable thermal setting, complete all as specified and directed.
Supply and fixing MCCB four pole 415V, 50 HZ, 16KA of rating (100A) with adjustable thermal setting, complete all as specified and directed.
Supply and fixing MCB SPN 240V, 50 HZ 10KA 'C' curve of rating (0.5-5A), complete all as specified and directed.
Supply and fixing MCB SPN 240V, 50 HZ 10KA 'C' curve of rating (6-32A), complete all as specified and directed.
Supply and fixing MCB SPN 240V, 50 HZ, 10KA 'C' curve of rating (63A), complete all as specified and directed.
Supply and fixing MCB SP 240V, 50 HZ, 10KA 'C' curve of rating (0.5-5A), complete all as specified and directed.
Supply and fixing MCB SP 240V, 50 HZ, 10KA 'C' curve of rating (6-32A), complete all as specified and directed.
Supply and fixing MCB SP 240V, 50 HZ, 10KA 'C' curve of rating (40A), complete all as specified and directed.
Supply and fixing MCB SP 240V, 50 HZ, 10KA 'C' curve of rating (50A), complete all as specified and directed.
Supply, fixing, testing and commissioning of high bay luminaire open version with anodised aluminium narrow beam and wide beam reflector comprising of HPK housing and HPK reflector suitable for 150 Watt SON lamp including lamp and all standard accessories including making connection with suitable size of copper conductor cable all as specified and directed. Cat Part No. : HPK 2051x50N 150 W of Philips or equivalent in Havells/Bajaj
Supply and erection of pressure die-cast aluminium, top opening street light suitable for and including 150W HPSV lamp having IP66 housing, POT reflector and gasket curved toughened glass cover complete with all accessories and ballast complete all as specified and directed. Cat Part No. : SUL 155V POT CAWCG of M/s Surya or equivalent in Havells/Philips
Metallic exhaust fan of size 300mm sweep complete with all accessories like louver shutter etc including provn of PCC grouting and duly connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to fan motor complete all as specified and directed Engr-in-Charge.
Ceiling fan 1200mm sweep and making connection with three core 23/0.0076 size twisted flexible copper conductor cable upto ceiling rose/fan motor complete all as specified and directed. Make : Havells/Khaitan/Usha
SCH 'A' PART-IX (SEC-II) HOT WATER SUPPLY WORKS
Supply, installation, testing and commissioning of solar water heating system with ETC TECHNOLOGY with electrical back up as per manufacturer specification suitable for single phase 220 V AC supply complete with ETC type collector, Hot water tank, tank stands etc as per following specifications :- (A) Collector. Collector 100 LPD ETC type with 10 nos of vertical evacuated tubes, duly installed on angle iron frame, transmittance of cover glass tubes 85%, reflectance of glass tubes more than 85%, absorbance of glass tubes 92%, type of coating (Cu/AI/SS) and reflectance of coating as recommended by manufacturer having wind resistance up to 100 Km with freezing resistance minus 20 degree C and heating up coefficient 240 degree C, having average thermal efficiency 58.76% and maximum rise in temp 53.04 degree C (in 24 hours) without night losses fixed at angle of inclination from horizontal as per recommendation of manufacturer. (B) Hot Water tank. Hot water tank of 100 ltr capacity with 2 KW electrical back up made out of stainless steel sheet not less than 0.5 mm thick duly insulated with puff insulation 50 mm thick having density not less than 36 kg/Cum, having thermal conductivity 0.29 M/K duly covered with PPGI cladding fixed with temperature gauge, inlet and outlet valves of suitable size duly installed on staging fabricated out of MS angle of appropriate size as recommended by manufacturer duly fixed properly and painted with two coats of anti corrosive paint over a coat of red oxide primer.
(a) Capacity 100 LPD and 2 KW electrical back up.
(b) All as per above item but 200 LPD capacity with 20 Nos of evacuated tubes and 2 KW electrical back up.
(c) All as per above item but 300 LPD capacity with 30 Nos of evacuated glass tubes and 6 KW electrical back up.
(d) All as per above item but 500 LPD capacity with 50 Nos of evacuated glass tubes and 6 KW electrical back up.
Notes for item No.6.01 to 6.05 :- (a) 5 Nos of spare ETC glass tubes with each system are to be supplied by the contractor with in over all cost quoted. (b) MS staging and puff insulated water storage tank for cold water, Hot and cold water pipes including valves (to and from system), insulation to pipe and valves to be measured and paid separately. (c) Any other item required for successful operation of system is deemed to be included in overall cost quoted. (d) Make of system : INTER SOLAR/SUN MAGIC/BIPIN INDUSTRIES/TATA BP SOLAR/BORO SOLAR/VENUS. (e) System shall be installed and commissioned by authorised rep of firm supplying the Solar water Heating system. (f) Stands for mounting of collector and hot water tank are included in over all cost quoted.
Puff insulated rotational mounted polyethylene water storage tank with closed hoisted and fixed in position of 200 ltr capacity.
Puff insulated rotational mounted polyethylene water storage tank with closed hoisted and fixed in position of 300 ltr capacity.
Puff insulated rotational mounted polyethylene water storage tank with closed hoisted and fixed in position of 500 ltr capacity.
Puff insulated rotational mounted polyethylene water storage tank with closed hoisted and fixed in position of 750 ltr capacity.
Construction of brick masonry staging as shown on Drg No CESZ/TD-1101 Sheet 1/1 for capacity up to 1000 ltr all as specified.
SCH 'A' PART-X (SEC-II) EXTERNAL WATER SUPPLY WORKS
DI fittings bends (any type radius angle) tapers any type (straight bend increasing decreasing or double socket etc) tee pieces single branch "Y" junction double branch cross (all socket and spigot) collar caps and plugs upto 150mm dia, complete all as specified and directed.
Cutting (2 cuts) in position of appropriate size for fixing 150mm dia sluice valve and supply & fixing 2 Nos of MS flanges 10mm thick with 150mm dia existing CI pipe duly holes drilled by welding/threading and matching with the flanges of sluice valve, complete all as specified. Note :- CI specials, CI lead joint & rubber gasket joint to be measured & paid separately.
S&F air release valve double isolating H-40 suitable for 100mm dia bore pipe with two Nos air outlet 50mm dia bore IS 14845, complete all as specified & directed.
Construction of valve pit of size 90cm x 90cm x 90cm (internal dimensions) in brick construction including all excavation and earth work in soft/loose soil returning filling in disposal of surplus spoil to a distance n. exc 50M and depositing where directed PCC in foundation of the mix (1:4:8) type D-2 (using 40mm graded crushed aggregate) brick masonry in cement mortar (1:4) rendering 12mm thick in cement mortar (1:4) internally finished even and fair and pointing flush externally as the work proceeds in the same mortar mild steel 50 x 6mm frame, MS sheet cover of 3.15mm thick with handle and locking arrangement, painting all the exposed MS work with two coat of synthetic enamel paint over a coat of red oxide of the make as approved all the MS embedded in PCC shall be treated with two coats of black bituminous paint complete all as specified and shown on drgs.
All as per Ser item No. 7.04 here-in-before but of size 60cm x 60cm x 60cm, complete all as specified and directed.
Supply and laying in trenches in any length, ductile Iron pipe 100 mm bore, spigot and socket joints, class K-9 conforming to IS-8329-2000 with tyton / rubber joint conforming to IS-5382, jointed and laid in trenches and connected complete all as specified and directed. Notes : (a) Earth work to be measured and paid separately. (b) Make of pipe : TATA/LANCO/JINDAL. (c) Pipe and fitting shall be ISI marked. (d) Fittings shall be of make as recommended by the manufacturer of the pipe included or of make as that of pipe. (e) Cost of rubber tyton joints is including in cost of pipe. (f) DI fittings shall be measured & paid separately.
SCH 'A' PART-XI (SEC-II) EXTERNAL ELECTRIFICATION WORKS
Supply and fixing 1 x 85 Watt street light fitting in a single piece deep drawn aluminium housing with side reflectors & Acrylic cover suitable for 85W CFL retrofit lamp and including with base B22, PF not less than 0.9 mounted on pole with GI pipe 40mm dia of 1.2M long, bend to shape with 02 Nos of FI clamps 50x6mm with suitable size nuts, bolts, washers etc and making the connection from pole to fitting with suitable size twin core copper conductor cable complete all as specified and directed. Make : Havells Cat Part No. LHRC-24185099 / Bajaj Cat Part No. BJSLF85RFCFLE27/SURYA CAT PART NO. SUL85CFRFALDDE4002
Supply, installation, testing and commissioning step down 11/0.433 KV (at No Load) transformer, 3 phase, 4 wire, AC 50 Cycles per second 315 KVA copper wound indoor type with off load manual tap changing arrangement on HT side to vary secondary voltage upto -18% to +6% for 9 steps @ 3% including suitable cable entry boxes on both sides to receive HT and LT cables complete in all respects with standard accessories and fitments conforming to IS-2026 Dy -11 connection complete all as specified and directed. NOTES :- 1 (a) Transformer shall be oil immersed, naturally / self cooled, double wound, copper winding core type, MS radiator cooled tank complete with first fill of transformer oil of dielectric strength not less than 30 KV as per IS-2026 and having following accessories: (b) Rating and diagram plates (c) Lifting lugs (d) Air release vent with plug (e) Conservator with oil indicator (f) Mild steel wheels with locking provision (g) Silica Gel Breather assembly with first filling of silica gel. (h) Oil temperature gauge and washout plug. (j) Complete with under/over voltage cut off, single phase preventer. 2. After installation of transformer testing shall be conducted by EI of HQ CENC or by rep of Accepting Officer before commissioning within overall cost & noted.
Sheet metal enclosure of size 250x150x100mm, having locking arrangement on front side with suitable size of rubber gasket kit, including painting to all internal and external portion with two coats of synthetic enamel paint over a coat of red oxide primer including fixing arrangement with 25x3mm size MS strip and complete with following :- (a) MCB 2.5 Amp, 10KA - 01 No. (b) 2 Pole aluminium bus bar 16 Amp - 01 Set Notes for serial item 8.01 to 8.10 :- (i) Pre-dispatch inspection shall be done by rep of accepting officer within overall cost quoted. (ii) General arrangement drawing shall be approved by GE before placement of order.
SCH 'A' PART-XII AIR CONDITIONING WORKS
Supply, installation and testing for satisfactory performance, Split Air Conditioners unit complete of capacity 1.5 Ton, electric driven single phase 230/240 volts 50 Hz, Cold and hot version, anti rust gold fin, all standard features as per design of manufacturer, timer delay function, compressor as per design of manufacturer reversible valve, technology non CFC gas based complete all as specified. Make- Blue Star/Voltas/Godrej/Samsung/Daikin
Supply, installation and testing for satisfactory performance, Split Air Conditioners unit complete of capacity 2.0 Ton, electric driven single phase 230/240 volts 50 Hz, Cold and hot version, anti rust gold fin, all standard features as per design of manufacturer, timer delay function, reciprocatory compressor as per design of manufacturer, reversible valve technology complete all as specified. Make- Blue Star/Voltas/Godrej/Samsung/Daikin Note for Serial item No. 1 & 2 : Air conditioner shall be suitable for operation at outside temp of minus 100C
Supply and installation 3 KVA voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170-250 volts with output voltage stabilized at 230 volts with accuracy of + 2.5% complete. Make- Micro Stabilizer/V Guard/Alpha Power Corp.
Supply and installation 5 KVA voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170-250 volts with output voltage stabilized at 230 volts with accuracy of + 2.5% complete. Make- Micro Stabilizer/V Guard/Alpha Power Corp.
SCH 'A' PART-XIII CENTRAL HEATING SYSTEM
OIL FIRED BOILER Supply, installation, testing and commissioning of oil fired glycol based Hot Water Generator using Kerosene/HSD oil complete with combustion chamber and equipment automatic monoblock burner assembly, fire tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electric panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, Single phase 220 Volts AC supply:- (a) Hot water inlet temp = 650 C. (b) Hot water outlet temp = 750 C. (c) Capacity 300000 Kcal/Hr at MSL. Notes :- (i) Make of boiler shall be REILLO/THERMAX/RAPIDCOOL. (ii) Pre dispatch inspection of boiler can be carried out by rep of AO within over all cost quoted. (iii) Higher capacity of boiler can be offered within overall cost quoted.
GLYCOL CIRCULATION CENTRIFUGAL PUMP: Supply, installation, testing and commissioning of monoblock centrifugal pump driven by suitable capacity electric motor for ethylene glycol 450 LPM 25 Mtr head. complete with accessories and including plain cement concrete foundation etc complete all as specified and directed.
GLYCOL MAKE UP CENTRIFUGAL PUMPS: Supply, installation, testing & commissioning of mono block centrifugal pump with Bronze impeller, driven by suitable capacity electric motor for glycol fluid make up and mixing with flow rate of 5 LPM & 5 Mtr head with accessories including cement concrete foundation etc complete all as specified and directed.9one working and one standby)
FLUE GAS EXHAUST PIPE/CHIMNEY : Supply and installation of mild steel flue gas exhaust pipe/chimney made out of 3 mm thick mild steel sheet, minimum 1.20 metre above the highest point of the plant room including connection from boiler to main chimney fabricated from 3mm thick mild steel sheet, all as specified. Note:- (i)The item shall be complete with the mounting/fixing arrangement. (ii) The each boiler shall be connected to a independent chimney. (iii) The portion of the chimney inside the building shall be insulated with fibre glass insulation wool 24 Kg/cum, 50mm thick and insulated portion covered with 28 SWG aluminum cladding. (iv) The generators shall be connected to an independent chimney.
EXPANSION TANK: Supply & Installation of overhead expansion tank of size 1000 litre 3mm thick mild steel tank complete covered with 13 mm thick closed cell electrometric insulation complete with removable lid, in/out/drain/overflow system including mounting arrangement making connections etc complete all as specified and directed.
GLYCOL FLUID TANK: Supply & Installation 1000 Litre capacity HDPE tank with removable lid, in/out/drains/overflows connection system, mounting arrangement etc complete connection, complete all as specified and directed.
BULK OIL STORAGE TANK: Supply, installation, testing and connecting with the system and commissioning of Horizontal Cylindrical oil storage tank made out of mild steel Design temp (-) 30°C and design pressure atmosphere + static head of liquid. (i) Storage capacity (Nominal) : 5 KL (ii) Gross Capacity (Not exceeding 5.2 KL) (iii) Shell thickness : 4mm (iv) End plate thickness : 5mm Note :-Tank shall be complete with all nozzles manhole, lifting lugs, earthing lugs, vent pipe dip stick suitable dia inlet, outlet connections and return pipes with flanges as per specification including civil works for insulations and staging.
DAY OIL STORAGE TANK : Supply, installation, testing and commissioning of Kerosene/HSD oil day service tank rectangular mild steel construction with capacity 990 litres complete with inlet, outlet, drain out pipe. Tank shall be made out of 3mm thick mild steel sheet and will be provided with supports made out of minimum 50 mm NB class 'B' pipe to keep tank base at minimum (1000 mm) above finished floor level complete, all as specified and directed.
TRANSFER GEAR OIL PUMPS K. OIL (SELF PRIMING) : Supply, installation, testing and commissioning of Rotary gear transfer pumps for capacity 15 LPM, 10 metre head, for Kerosene oil complete with base frame, foundation bolts, coupling and coupling guard and TEFC flame proof motor (2HP), and other accessories required for commissioning etc complete all as specified.
HSD OIL PIPING : Supply, installation, testing and commissioning of mild steel heavy duty ( 'C' Class) pipe including bends, reducers, flanges, nuts, bolts etc, complete in all respects of following sizes all as specified and directed :-
(a) 32mm dia pipe.
(b) 25mm dia pipe.
(c) Ball valves of size 25mm dia.
(d) Non return valves of size 25mm dia.
(e) Y- oil strainer of size 25mm bore.
(f) Ball valves of size 32 mm dia.
(g) Ball valves of size 15 mm dia.
HOT GLYCOL FLUID PIPING : (i) Supply laying, connecting and testing of mild steel ERW, class 'C' piping complete with fittings, duly insulated with 25mm closed cell elastomeric insulation 30 to 40 Kg/m3 density covered with shrink wrap polyethylene sheet for the following sizes of Hot Glycol fluid pipes.
(a) 100mm dia with 25mm thick nitrile insulation.
(b) 80mm dia with 25mm thick nitrile insulation.
(c) 65mm dia with 19mm thick nitrile insulation.
(d) 50mm dia pipe with 19mm thick nitrile insulation.
(e) 40mm dia pipe with 19mm thick nitrile insulation.
(f) 32mm dia pipe with 19mm thick nitrile insulation.
(g) 125mm dia pipe with 25mm thick nitrile insulation.
(ii) Supply, laying, connecting and testing of 3 layer poly propylene random copolymer pipes or composite pipes conforming to PN 16 complete with fittings duly insulated with 13 mm thick closed cell elastomeric insulation 30 to 40 Kg/m3 density for the following sizes of Hot Glycol fluid pipes:-
(a) 40mm dia OD pipe with 13mm thick nitrile insulation.
(b) 32mm dia OD pipe with 13mm thick nitrile insulation.
(c) 25mm dia OD pipe with 13mm thick nitrile insulation.
(d) 20mm dia pipe with 13mm thick nitrile insulation.
(e) Poly urithane pipe 8x12mm (For FCU connections)
(f) Butter fly valves 65mm dia.
(g) Butter fly valves 40mm dia.
(h) Balancing valves 65mm dia.
(j) Dual plate Non Return valves 65mm dia
(k) Y strainer 65mm dia.
(l) Ball valves 25mm dia.
(m) Ball valves 15mm dia.
(n) Inlet/outlet valves for FCU.
(o) Pressure gauges with cocks and syphon
(p) Water flow switches
(q) Automatic air purgers valves
METAL CLADDING : Supplying and fixing of aluminium cladding of 24 SWG on insulated pipes of following sizes :-
(a) 100mm dia MS pipe with 25mm thick insulation.
(b) 80mm dia MS pipe with 25mm thick insulation.
(c) 65mm dia MS pipe with 25mm thick insulation.
(d) 50mm dia MS pipe with 25mm thick insulation.
(e) 40mm dia MS pipe with 25mm thick insulation.
(f) 32mm dia MS pipe with 25mm thick insulation.
(g) 13mm dia MS pipe with 25mm thick insulation.
(h) 125mm dia pipe with 25mm thick nitrile insulation. Note : Aluminium cladding shall not be provided to underground pipe.
FAN COIL UNITS: Supply, Installation, Testing and Commissioning of wall/floor mounted Fan Coil units complete with top grill, ABS (Plastic) casing, 3 speed motor, wall mounting brackets inlet outlet manifold, etc complete of following capacity (Make : UNIVERSAL RACI/MAKTEK/VOLTAS) :-.
a) Capacity 6000 kcal/hr.
b) Capacity 4500 kcal/hr.
c) Capacity 3000 kcal/hr.
d) Towel Radiator Wall mounted 600 X 910 mm size.
CABLE TRAYS : Supplying, fabricating and installing perforated mild steel cable trays of size 150 mm width x 50mm depth including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with mild steel suspenders and including painting with two coats of synthetic enamel paint over a coat zinc chrome primer, all as specified and directed. (For cabling work in plant room)
Supply, laying and, testing of PVC insulated and sheathed (ISI marked) copper multistrand conductor, armoured cable of 1.1KV grade conforming to IS -1554 of size 4 x 6 sqmm complete, all as specified.
Supply, laying and, testing of PVC insulated and sheathed (ISI marked) copper multistrand conductor, armoured cable of 1.1KV grade conforming to IS -1554 of size 3 x 4 sqmm complete, all as specified.
Supply, laying and, testing of PVC insulated and sheathed (ISI marked) copper multistrand conductor, armoured cable of 1.1KV grade conforming to IS -1554 of size 3 x 2.5 sqmm complete, all as specified.
ELECTRCAL ACCESSORIES : Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing interconnecting the main panel and other electrical equipments.
Danger notice plate of 200mm x 150mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides painted with letters, figures and conventional skull and bones in signal red colour on frontal side as required, including fixing with MS clamps, bolts and nuts of approved size all as specified.
Providing " No Smoking" and "Flammable" sign board as per requirement of Petroleum rules and CCOE Nagpur.
Sand cushioning to underground electric cables all as per clause 19.75 of MES Schedule Part-I. Note :- Sand cushioning shall be fine sand as specified for plastering.
Supply & laying common burnt clay building sub class 'B' old size bricks, laid at right angle along the cable complete all as specified and directed. Note : The bricks shall be laid flat butting to each other in such a way that the length of the bricks at right angle to the central axis of the cable.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron earth lead strip 32 x 6mm, by means of bolt, nuts , check nuts and washer of GI and earth wire protected by provision of GI pipe medium grade, 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 40 x 40 x 6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. Note :- Item of earthing included cost of 7.5m long Galvanized iron earth lead 32x6 mm size and protection pipe of 40mm bore GI medium grade. Any variation in length shall be adjusted through deviation order.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth, for foundations, laying of pipes etc and not exceeding 10Sqm on plan for manholes etc and not exceeding 1.50m in depth and getting out in hard/dense soil, complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified.
Removing excavated material (Soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Notice board (Display Board) of size 1200mmX900mm as shown on drawing No CESZ/TD-175/94 sheet 1/1 for displaying the duty roaster description and including resuscitation chart in three languages for electric shock and burn injury complete all as specified and directed.
Supply, installation, testing and commissioning of silent type diesel engine driven generating set of capacity 100 KVA, 415 Volts, 0.8 power factor at NTP, mounted on common base platform with flexible coupling, 1500 RPM along with sound proof enclosure(acoustic enclosure) designed for reducing the sound level to 75 DB upto 1 mtr (Avg) IS-8528 part 10 as per approved CPCB norms and as per GSR 371(E) dated 17.05.2002 and as amended time to time with silencer pipe protected with asbestos rope independently supported from engine to outside of power house upto 1.0M, AVM pads, foundation as per manufacturer's design, cold starting kit, battery start with suitable cables for connecting from DG Set to panel board. DG Set shall be capable to operate for temp range from (-200 to + 350 C), complete with canopy and including the following :-
(A)_PRIME_MOVER : Vertical diesel engine of capacity not less than 69 BHP, water cooled closed circuit as per BS-649 or IS- 10002 direct injection type turbo charged. The DG Set shall be capable of running 24 Hrs continuously with 10% overloading for one hour in every 12 hours as per BS-5514/ BS-649. Engine shall be equipped with all standard fittings as per manufacturer's recommendations and mounted on common base frame with following fittings:- (a) RPM cum hour meter. (b) Battery charging ammeter. (c) Ignition key and starting with push button switch. (d) Lubricating oil pressure gauge. (e) Electronic governor controlling. (f) Toggle switch for idle running. (g) Oil temp gauge (h) Water temperature gauge (j) Safety control (trip) for the following:- (i) High water temperature (ii) Low lubricating oil pressure. (iii) Over speed. (k) Lubricant oil coolant heater to avoid freezing. (l) 24 Volt starting equipment comprising of the following :- (i) 12 Volt 180 AH 25 plates Battery - 02 Nos Make : Exide/Amaron (ii) Battery charging alternator with inbuilt regulator . (iii) Self starter of suitable capacity. (iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and terminals.
(B) ALTERNATOR : Alternator rating 100 KVA, 3 phase, 50 cycles, 415 Volts, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM self excited, self regulated mounted on common base frame, mounted on a permanent foundation screen protected with self excited with filed brush rotating fixed design to be coupled with above engine through flexible coupling, the alternator shall be conforming to BS-2613 or IS-4722. (C) CONTROL_PANEL: The Control Panel body will be fabricated out of 16 SWG MS sheet. The Panel will be suitable for canopy mounting, indoor installation, dust and vermin proof, copper control cable of suitable size shall be used. Cable shall be ferruled for proper maintenance/checking/wiring of panel. Detachable cable gland plates shall be provided. The panel shall be equipped as follows:- (a) MCCB of suitable capacity - 1 No. (b) Aluminium bus bars of suitable capacity provided with termination - 1 Set (c) Current transformer of suitable ratio - 03 Nos (d) Instrument MCBs - 01 Set (e) Micro processor based controller for controlling various mechanical and electrical protections with display and indication of electrical and mechanical parameters as follows:- (i) Display Parameters :- (1) Electrical Parameters - Phase Voltage, Line Current & Frequency (2) Mechanical Parameters - Lube Oil Pressure, Coolant Temperature (for Liquid cooled engines), Engine Speed, Fuel Status, Engine Run Hours and Battery Voltage. (ii) Protections :- (a) Electrical Protections - Under / Over Voltage, Under / Over Frequency, Phase Failure, Phase Sequence Reverse, Over Current and Over Kilo Watt. (b) Mechanical Protections - Under / Over Speed, Low Lube Oil Pressure, High Engine Coolant Temperature (for Liquid Cooled Engines) and Low Fuel Level Alarm
(D) OTHER FITTINGS : (a) Battery charger : Battery charger having electric circuit consisting of triodes rectifiers, capacitors and resistance etc. The battery charger should be able to charge 24 volts 180AH battery - 02 Nos at all the time whenever electric supply given to battery charger through control panel or electric power point. (b) Fuel tank : Inbuilt fuel tank of suitable capacity as per manufacturer's instruction capable to store fuel for 12 hour running of DG set with oil pipes, including oil level indicating gauge, drain and air vent plug etc. Notes : (i) Complete DG set shall be supplied by any of the manufacturers specified in list of approved makes/manufacturers given in Appx -E to PS. (ii) Precommissioning test shall be carried out by rep of Accepting Officer within overall cost quoted by the contractor. All Testing arrangement including POL shall be made by the contractor. (iii) DG Set shall be mounted on PCC platform as per manufacturer recommendations and cost there of shall be included in the overall cost. (iv) The contractor shall produce a copy of approved certificate to authenticate the above from the OEM/OEA.
(E) MAINTENANCE SPARES : (i) Fuel filter element - 02 Nos (ii) Oil filter elements - 03 Nos (iii) Fan belt - 01 Set (iv) Hose pipe - 01 Set (v) Tappet cover gasket - 01 No (F) DG set shall be supplied along with acoustic original enclosure of the manufacturer's suitable for 100 KVA DG set as per CPCB norms. Notes :- (a) Complete central heating system shall be run on a trial bases for one month only on successful completion of trial period Phase - one test shall be conducted. POL during trial run shall be given by deptt free for use. (b) After issue of completion a training for a period of three months shall be imparted to staff of MES on running and maintenance of system with in over all cost quoted. (c) Any modification required for successful operation of plant shall be carried out by contractor within overall cost quoted. (d) Piping layout for CHS shall be decided by contractor in consulation with GE.
mirco builders
SHAH AND SONS
M/s Hafizullah Beigh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.09 MB
Download all tender documents and submit your bid