Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹31.7 L+₹1.8 L (6.04%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹32.5 L+₹2.6 L (8.64%)Admitted-Finance KHATA NO 254 529 KHASRA NO 364 2 MIN PREET NAGAR A GALI NO 2 HARERI ROAD OPP STAR STUDIO HERARI SANGRUR | SANGRUR | SANGRUR | PUNJAB | L3 | Admitted-Finance | |
| 4 | L4₹40.0 L+₹10.1 L (33.6%)Admitted-Finance 6 U 34 JAWAHAR NAGAR SRI GANGANAGAR SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical Applicant not fulfill the eligibility criteria |
| Sl No | Description | Qty | Unit | JINDAL AND COMPANY L3 | BABA FARID CONSTRUCTION CO L1 | Ankit Jindal And Company L4 | yogesh kumar contractor L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for Racking out of old existing sealant compound and back up rod of the existing joints 10mm wide by special tools like cutting blades/ machines, widening of joints 2mm by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. The depth of sealant above back rod 8mm. . Thereafter filled with closed cell, medium density, crossed linked polyethylene foam backup rod of 8 mm dia for complete length of the joint, over it to be filled with polyurethane joint sealant meeting the requirements mentioned BS-5212 , BS 4254 and EN – 141875- 2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and directed by Engr-in-Charge. | 475 | X RM | 900 ₹4,27,500 | 808 ₹3,83,800 Lowest | 1,135 ₹5,39,125 | 1,170 ₹5,55,750 |
| 2.00 | Material and labour for Racking out of old existing sealant compound and back up rod of the existing joints 14mm wide by special tools like cutting blades/ machines, widening of joints 2mm by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. The depth of sealant above back rod 12mm. . Thereafter filled with closed cell, medium density, crossed linked polyethylene foam backup rod of 12mm dia for complete length of the joint, over it to be filled with polyurethane joint sealant meeting the requirements mentioned BS-5212 , BS 4254 and EN – 141875- 2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and directed by Engr-in-Charge. | 900 | X RM | 1,000 ₹9,00,000 Lowest | 1,140 ₹10,26,000 | 1,400 ₹12,60,000 | 1,260 ₹11,34,000 |
| 3.00 | Material and labour for Racking out of old existing sealant compound and back up rod of the existing joints 25mm wide by special tools like cutting blades/ machines, widening of joints 2mm by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. The depth of sealant above back rod 8mm. Thereafter filled with 25mm thick compressible polyethylene closed cell type filler board as specified, over it filled with closed cell, medium density, crossed linked polyethylene foam backup rod of 30 mm dia for complete length of the joint. Finally filled with polyurethane joint sealant meeting the requirements mentioned BS-5212 , BS 4254 and EN – 141875- 2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and directed by Engr-in-Charge.
Note :- Any joint of width if exceeding 25mm would also be measured under this item. The quoted rates would deemed to have included this item.
Note: 01 to 03 item: Rate quoted by bidder is deemed to be inclusive of all the equipment for removing old sealant and filling the sealant. Also, rate quoted is deemed to be inclusive of sealant, backup rod and filler board. | 1,100 | X RM | 1,750 ₹19,25,000 | 1,440 ₹15,84,000 | 2,000 ₹22,00,000 | 1,350 ₹14,85,000 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BHISIANA
HQ CWE AF BHISIANA
REPAIR TO JOINT FILLING OF RUNWAY, DISPERSAL AND BLAST PEN IN TECH AREA AT AF STN HALWARA UNDER GE (AF) HALWARA
2026_MES_789033_1
CWE(BHI)/HAL-74/2026-27
Open Tender
Civil Works
Works
180 days
Halwara
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF HALWARA
₹90,000
Yes
2 Nov 2026
11 Sept 2026
9 Oct 2026
11 Sept 2026
7 Oct 2026
25 Sept 2026
14 Sept 2026 - 21 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for Racking out of old existing sealant compound and back up rod of the existing joints 10mm wide by special tools like cutting blades/ machines, widening of joints 2mm by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. The depth of sealant above back rod 8mm. . Thereafter filled with closed cell, medium density, crossed linked polyethylene foam backup rod of 8 mm dia for complete length of the joint, over it to be filled with polyurethane joint sealant meeting the requirements mentioned BS-5212 , BS 4254 and EN – 141875- 2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and directed by Engr-in-Charge. | 475 | X RM | - | - |
| 2 | Material and labour for Racking out of old existing sealant compound and back up rod of the existing joints 14mm wide by special tools like cutting blades/ machines, widening of joints 2mm by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. The depth of sealant above back rod 12mm. . Thereafter filled with closed cell, medium density, crossed linked polyethylene foam backup rod of 12mm dia for complete length of the joint, over it to be filled with polyurethane joint sealant meeting the requirements mentioned BS-5212 , BS 4254 and EN – 141875- 2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and directed by Engr-in-Charge. | 900 | X RM | - | - |
| 3 | Material and labour for Racking out of old existing sealant compound and back up rod of the existing joints 25mm wide by special tools like cutting blades/ machines, widening of joints 2mm by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. The depth of sealant above back rod 8mm. Thereafter filled with 25mm thick compressible polyethylene closed cell type filler board as specified, over it filled with closed cell, medium density, crossed linked polyethylene foam backup rod of 30 mm dia for complete length of the joint. Finally filled with polyurethane joint sealant meeting the requirements mentioned BS-5212 , BS 4254 and EN – 141875- 2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and directed by Engr-in-Charge.
Note :- Any joint of width if exceeding 25mm would also be measured under this item. The quoted rates would deemed to have included this item.
Note: 01 to 03 item: Rate quoted by bidder is deemed to be inclusive of all the equipment for removing old sealant and filling the sealant. Also, rate quoted is deemed to be inclusive of sealant, backup rod and filler board. | 1,100 | X RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tender74.pdf
Tender Documents • 0.85 MB
BOQ_884461.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .