Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | ₹7.8 L Quoted ₹8.0 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹8.0 L+₹5,262 (0.66%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.0 L+₹5,262 (0.66%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹8.1 L+₹9,466 (1.19%)Rejected-AOC 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | ₹8.1 L+₹9,466 (1.19%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹9.9 L+₹1.9 L (24.4%)Rejected-AOC JHABRERA ROAD NEAR POWER STATION MANGLOR DISTT HARIDWAR UTTRAKHAND | MANGLOR | HARIDWAR | UTTARAKHAND | ₹9.9 L+₹1.9 L (24.4%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹9.9 L+₹1.9 L (24.4%)Rejected-AOC | ₹9.9 L+₹1.9 L (24.4%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹10.5 L
EMD Value
₹21,020
Closing Date
27 Jul 2022, 6:00 pmClosed
GE 871 EWS
GE 871 EWS C/o 56 APO
REPAIR REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING LIGHT FITTINGS INCLUDING OTHER E/M ALLIED WORKS AGAINST MAINT PROGRAMME OF ZONE -II UNDER GE 871 EWS
2022_MES_530993_1
8685/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Joshimath
As per tender documents
7 documents required · 7 mandatory
₹500
GE 871 EWS
₹21,020
Yes
5 Sept 2022
15 Jun 2022
3 Aug 2022
15 Jun 2022
27 Jul 2022
2 Jul 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc all as specified and directed .
M&L for point wiring in PVC casing & caping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly all as specified and directed for One light/fan point bell point controlled by one ,one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
M&L for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly all as specified and directed for One light/fan/bell point controlled by one ,one way switch
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 6 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F in replacement of switch piano flush type 15/16 Amps single pole one way all as specified & directed.
S& F in replacement socket out let 5 pin 5/6 Amps all as specified and directed.
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed.
S&F of call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 3 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 4 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 6 module complete all as specified and directed.
S&F in replacement Modular metal flush/PVC terminal boxes with lumina plate and frame suitable for 8 module complete all as specified and directed.
S&F in replacement Switch modular type single pole one module, 6 Amps complete all as speciifed.
S&F in replacement Switch modular type single pole one module, 16 Amps complete all as speciifed.
S&F in replacement Socket outlet mdoular type, multipurpose, 2/3 pin, single pole two module, 6 Amps complete all as speciifed.
S&F in replacement Socket outlet mdoular type, multipurpose, 2/3 pin, single pole two module, 6/16 Amps complete all as speciifed.
S&F in replacement Modular bell push single pole one module, 6 Amps complete all as speciifed.
S&F Modular blank plate one module.
S&F in replacement of ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified & directed.
S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S&F in replacement 5 watt LED bulb. cool day light, 230/240V AC supply all as specified and as directed.
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC supply all as specified and directed.
S&F in replacement of LED light fitting two feet 1x10 watt, slim design, 230volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
S&F in replacement LED tube light fitting 4 ft, bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed on bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed .
Taking down and refixing of LED tube light fitting bright 18 Watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
M&L earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed .
Supply and fix in replacement of DB, TPN 4 way vertical type with single/three phase outgoing with provision for MCCB as incomer 415 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replcement MCB 6-40 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed .
Supply and fix in replcement MCB 32-40 amps, 10 KA, SPN 240 volt, 'C' series all as specified and directed
All as per item No 40 here in before but MCB SPN 63 amps.
All as per item No 40 here in before but MCB TPN 63 amps.
All as per item No 40 here in before but MCB TPN 100 amps.
Supply & fix in replacement of on load change over switch 4 pole, 63 Amps suitable for 3 phase, 415 volts in sheet metal enclosures fixed in sheet metal box made out of 2 mm thick CRCA sheet of suitable size completet all as specified & directed .
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed
S&F PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
S&F in replacement of PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply and fix in replacement of stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed.
S&F in replacement of inner tank 9 holes suitable for Geyser 25 liters capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of inner tank 6 holes suitable for Geyser 25 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of inner tank 9 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of inner tank 6 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of Inner tank 9 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of Inner tank 6 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made of stainless steel duly prewired.
S&F in replacement of indication lamp (Green/Red) as per required at siteall as specified & directed.
S&F in replacement of thermal Auto cut of range 0-90 degree centigrade (ISI marked) complete all as specified and directed.
S&F in replacement of geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
S&F in replacement of Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
S&F in replacement of Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed
Taking down carefully unserviceable exhaust fans of any size from its position, dismanteling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Supply only of defective parts like ball bearing, bush bearing and motor rewinding, shaft, condensor, rubber shackle will be measured and paid separately
Supply only of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed.
Supply only condenser capacity 4/3.15/2 MFD all as specified and directed. Make : Usha/Universal/ Keltran
M&L For Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
M&L for burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep all as specified and directed.
Supply only of blade suitable for exhaust fan 300/450mm, size as that of existing defective one all as specified and directed. (ISI Marked)
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x6 sqmm PVC insulated multistrand copper conductor with 01x6 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 6 sqmm conductor with casing caping will be measured as one length.
M&L in replacement of sub main wiring in PVC conduit (Surface/conceled ) of required size 2x6 sqmm PVC insulated multistranded copper conductor with 01x6 Sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 6 sqmm conductor with conduit will be measured as one length.
Supply and fix in replacement of cable PVC insulated solid aluminium conductor of size 10 sqmm 2 core flat 1100 volt grade heavy duty served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire all as specified and directed.
Taking down and dismantling of 1.5/2 Ton capacity air conditioner after disconnecting of electric connection for servicing, overhauling and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts Note :- Supply only of defective parts like capacitor, compressor, condensing coil , fan motor, blower motor, fan blade, and gas charging will be measured and paid separately under relevent item of schedule.
Supply only of compressor complete suitable for 1.5 Ton Capacity Air conditioner complete all as specified and directed. Make : VOLTAS/BLUE STAR/CARRIER
Supply only of compressor complete suitable for 2 Ton Capacity Air conditioner complete all as specified and directed. Make : VOLTAS/BLUE STAR/CARRIER
Supplyonly of capacitor (Starting/running) complete suitable for 1.5/2 Ton Capacity Air conditioner (ISI Marked) complete all as specified and directed.
Supply only of condensing coil assembly complete suitable for 1.5/2 Ton Capacity Air conditioner complete all as specified and directed. Make : VOLTAS/BLUE STAR/CARRIER
M & L for GAS Charging (R-22/134A) complete suitable for 1.5/2 Ton Capacity Air conditioner complete all as specified and directed.
Supply only of PVC Fan blade complete suitable for 1.5/2 Ton Capacity Air conditioner (ISI Marked) complete all as specified and directed.
Supply only of Fan Motor/Blower motor complete suitable for 1.5/2 Ton Capacity Air conditioner complete all as specified and directed.
Taking down and dismantling of refrigerator/deep freezer of capacity 160-320 litres of capacity after disconnecting of electric connection for servicing, overhauling and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts all as specified and directed. Note:- Supply only of defective parts like capacitor, compressor, condesing coil, fan motor, blower motor, fan blade and gas charging will be measured and paid separately under relevent item of schedule.
Supply only of compressor suitable for 160-320 litres capacity refrigeratror. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
Supply only of capacitor (starting/running) suitable for 160-320 litres capacity refrigerator (ISI Marked) all as specified and directed.
Supply only of condesing coil assesmbly suitable for 160-320 litres capacity refrigerator all as specified and directed. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
M&L GAS charging (R-24/134A) suitable for 160-320 litres capacity refrigerator all as specified and directed.
Supply only of PVC/Iron fan blade suitable for 160-320 litres capacity of refrigerator. (ISI Marked) all as specified and directed.
Supply only of fan motor/blower motor suitable for 160-320 litres capacity of refrigerator all as specified and directed.Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
Repair/maintenance of defective/rusted storage type solar water heater of capacity 200/500/1000 litre from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the solrar water heater in position, insulation of pipe lines complete with building, painting of solar water stand and water tank stand with black paint weather proof, repair of leakage including soldring/gas welding and repair of foundation, replacement of electric cable as per site requiement testing all as specified and directed.
S&F in replacement of solar heating element 3 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of LED tube light fitting, 4 ft, bright 18 watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Havells Cat Pt No LHEXBLP7JN1W018 or equivalent of Philips/ Cromton
Supply and fix in replacement of LED slim square panel light fitting for surface ceiling light, 8 watt, colour white/warm white and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply and fix in replacement of LED square panel light fitting, 36 Watt, 2x2 feet edge-lit luminaire suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply and fix in replacement of Decorative LED 15 watt new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
S&F in replacement 9 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Havells/philips/Cromton
S&F in replacement 5 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Havells/philips/Cromton
S&F in replacement of LED light fitting, 1 x 10 watt bulk head luminaris, Landscape lighting fixture with all accessories and including connecting up with twin core twisted flexible copprer conductor from celing rose to fittting connector all as specified and directed.
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed.
Supply and fix in replacement of PVC conduit pipe of size 20 mm dia all as specified and directed.
Supply and fix in replacement of PVC casing caping of size 25 mm dia all as specified and directed.
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F in replacement of switch piano flush type 15/16 Amps single pole one way all as specified & directed.
S& F in replacement socket out let 5 pin 5/6 Amps all as specified and directed.
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F plug top 15 Amp white or ivory, ISI marked all as specified and directed.
S&F plug top 5 Amp white or ivory, ISI marked. Make : Havells/Anchor/legrand/HPL
S & F in replacement of SSC 15 Amp including PVC gang box and fixing screw ISI marked. Make :Havells/Anchor/legrand/HPL
S&F in replacement of SSC 5 Amp including PVC gang box and fixing screw ISI marked. Make : Havells/Anchor/legrand/HPL
M&L in replacement of 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed.
M&L in replacement of 2.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed.
Bedi Refrigeration Works
JAGAT POWER ELCTRICAL
M/S Swarn Constructions
Amit Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .