Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.1 L+₹2.6 L (5.80%)Rejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹51.7 L+₹7.2 L (16.3%)Rejected-Finance MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹52.6 L+₹8.2 L (18.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹54.3 L+₹9.8 L (22.1%)Rejected-Finance 2ND FLOOR SC ROAD SANTA PLAZA TEZPUR DISTT SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Oct 2024, 6:00 pmClosed
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
REPAIR/REPLACEMENT AND DAY TO DAY MAINTENANCE OF INTERNAL WIRING, LIGHT FITTINGS , SWITCH GEARS , LED FITTINGS REPAIR TO GEYSER, CEILLING FANS , AIR CONDITIONERS, REFRIGERATORS WATER COOLERS AND COOLING APPLIANCES WITH RELATED CONNECTED WORKS AT N
2024_MES_668444_1
GE(N)/TEZ/2024-2025/8951
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) TEZPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹96,000
7 Dec 2024
31 Aug 2024
10 Oct 2024
31 Aug 2024
3 Oct 2024
14 Sept 2024
Amount
M & L for point wiring with 1.5 sqmm FRLSH, PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade (MMS ISI) of size not less than 20 mm dia(or as site requirement) concealed in wall/over ceiling,modular metal flush boxes of required size and with modular plates incl of all accessories and all as specified including 1.5 sqmm FRLSH PVC insulated sheathed multistranded copper earth conductor to common earth and connected to earth dolly for light / fan/ bell point controlled by one switch including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge. Note:- (i) Cost of PVC conduit, modular plates,frames, cover plates etc; are deemed to be included in the quoted rate. (ii) M&L for cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate.
All as per item 1.0 above but for 3 pin 5 Amps switch socket on independent board with 1.5 sq mm copper cable including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item 1.0 above but for 3 pin 16 Amps switch socket combination on independent board with 2.5 sq mm copper cable including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item 1.0 above but for 5 Amps socket point on the same board controlled by one switch including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item 1.0 above but for one light point controlled by two, two way switch with 1.5 sq mm copper conductor cable including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
M & L for point wiring with 1.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25/32 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, PVC terminal box and PVC board making good disturbed surface to match with the existing surface for one light /fan/bell point controlled by one switch including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item 6.0 above but for One 3 pin socket outlet 5 Amps on same board including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item 6.0 above but for One 3 pin socket outlet 5 Amps on indpendent board including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item No.6.0 above but with 2.5 sqmm single core multistranded copper conductor FRLSH cable for 3/5 pin 15 Amp socket outlet on independent board including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item No.6.0 above but with 2.5 sqmm single core multistranded copper conductor cable for 4x1 number 3/5 pin 5/6 Amp socket outlet on independent board including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item No.6.0 above but with 2.5 sqmm single core multistranded copper conductor cable for 2x1number 3/5 pin 5/6 Amp socket outlet on independent board including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
All as per item 6.0 above but for one light point controlled by two, two way switch with 1.5 sq mm copper conductor cable including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.
S & F in repairs/replacement of modular switch 10A,1 module single pole, one way complete all as specified and directed.
S & F in repairs/replacement of modular socket outlet 5 pin ,6 Amps,2 module, 240 Volts complete all as specified and directed.
S & F in repairs/replacement of modular switch 16A,1 module single pole, one way complete all as specified and directed.
S & F in repairs/replacement of modular socket outlet 5 pin ,16 Amps,2 module, 240 Volts complete all as specified and directed.
S & F in repairs/replacement of modular switch 10A,1 module single pole, two way complete all as specified and directed.
S & F in repairs/replacement of modular bell push switch 5 Amps complete all as specified and directed.
S & F in repairs/replacement of call bell, Ding dong type, AC 230 Volts single pole complete all as specified and directed.
S & F in repairs/replacement of ceiling rose polycarbonate type three terminals complete all as specified and directed.
S & Fin repairs/replacement of modular step type electronic fan regulator ,two module 120 watt single pole 240 Volts complete all as specified
S & F in repairs/replacement of Lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendent fitting complete all as specified and directed
S & F in repairs/replacement LED inverter type bulb with 4 hrs backup of 10W with Lumen output 95 lm and Colour Temp 6500K B22 type fitted suitable for PVC /Poly Carbonate type complete all as specfied and directed.
S & F in replacement WW LED candle LAMP of 3 watt with Lumen output 240 lm and Colour Temp 3000K E14 type fitted suitable for PVC /Poly Carbonate type complete all as specfied and directed.
S&F in replacement LED Tube light luminaires, 20-22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of from connector and ceiling rose, complete all as specified and directed. Make :- Philips model SmartBright or equivalent in Wipro / Crompton
S&F in replacement mirror light batten type 11 W 230V AC, 50Hz, Pf >0.98, THD <10% on wall complete all as specified and directed by Engineer in charge. Make :- Philips model no-31165 or equivalent in Wipro / Crompton
S&F in replacement of LED bulk head wall light fixture 10 Watt , pressure die cast housing , IP 66 protection and IK 09 impact resistance suitable for surface and wall mounting complete all as specified and as directed. Make Philips(Cat No:- WT202W LED6S CW PSU S2 PC) or equivalent in Wipro / Crompton.
Supply and fixing in replacement of LED spot light fixture 5/7 Watt , tiltable with decorative finish of warm white coloured complete all as specified and as directed by Engr in charge. Make Philips(Cat No:-7W Sky COB Tilt LED Spotlight(WW) or equivalent in Wipro / Crompton.
Supply and fixing in replacement decorative wall light fixture metalic body single head wall light suitable for 20 watt maximun wattage complete all as specified and as directed. Make Philips(Model No - 31455 Chiffe wall light ) or equivalent in Wipro / Crompton.
S & F in replacement LED recess mounted (2'x2' size flat panel) luminaire which provide soft light and glare free symmertical illumination suitable for armstrong/grid ceiling of 36Watt,(Lumen output not lessthan 3600) complete all as specified and directed. Make Philips Smart Glow(Cat No:- RC383B LED 36S-6500 PSU OD WH PIR) or equivalent as Wipro/Havells/Crompton
S & F in replacement Recess/ceiling mounted round glow type LED light 7 Watt down light aluminum die cast housing white/warm, dust free and zero maintainence complete all as specified and as directed by Engr in charge. Make Philips(Cat No:- DN091B LED6S - 6500 PSU WH) or equivalent in Wipro / Crompton..
S&F in replacement ultra bright LED PLL with high efficacy 18 W operated in single phase, 230 volts, 50HZ, suited for installation in existing 2G11 lamp holders complete all as specified and directed. make Havells or equivalent Make in Bajaj/CG
S & F in replacement new generation energy saving and environmental friendly long life 35/40W LED wall street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including necessary brackets (made out of suitable bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls with MS clamp complete all as specified and directed. Make:- Philips of Model -SmartBright Street or equivalent in Wipro / Crompton.
M & L for detecting faults in LT electric supply distribution system in Md Accn/OTM in the NAA and rectifiying the defects for restoring supply including replacing of unserviciable defective electrical accessories. Note :- (i) Spares shall be measured and paid under respective item of schedule . (ii) Essential material like, complain slip book, insulation tape, screws, wodden/plastic gutka and all tools required for carrying out the works and insutruments to the defect fault shall be deemed to be included in the quoted rate.
Taking down ceiling fan any type/ size from hook and dismantling cable and blades and bring in to contractor store for repair and hanging ceiling fan in position after repair, greasing etc. with existing flexible copper cable complete all as directed. (rewinding of fan, painting and spare parts required shall be deemed to be included in the quoted rate)
Taking down exhaust fan any type/ size from wall and dismantling sealing cable and dismantling blades and bring in to contractor store for repair and fixing exhaust fan in position after repair, greasing etc. with existing flexible copper cable complete all as directed. (rewinding of fan, painting and spare parts required shall be measured and paid separately)
M&L for rewinding of ceiling fan 1200/1400 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed.
M&L for rewinding of exhaust fan 280 to 450 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed.
S & F in replacement brass bush for ceiling fan / exhaust fan as existing size complete all as specified and directed.
S & F in replacement bearing suitable for ceiling fan 1200 mm to 1400 mm /exhaust fan of bearing No- 6201/6202 complete all as specified and directed.
S & F in replacement capacitor 2.5 MFD for ceiling fan. complete all as specified and directed.
S & F in repairs/replacement capacitor 3.15 MFD for ceiling fan complete all as specified and directed.
S & F in repairs/replacement capacitor 4.0 MFD for exhaust fan complete all as specified and directed.
S & F in repairs/replacement rubber real with bolts, nuts and clamps of suitable for ceiling fan complete all as specified and directed.
S&F PVC insulated flexible copper cable 3 core of size 23/0.0076 complete all as specified and directed.
Taking down carefully water heater storage type of any capacity from its position for repair/ overhauling by disconnecting complete electric/water supply connections, taking out geyser assembly repairing by minor welding of inner tank re-assembling the geyser and refixing the same by connecting electric / water supply connections and testing complete all as specified and directed. Note: (spares will be measured and paid separately)
S&F in replacement old u/s element and fixing of new heating element of capacity 1.5/2 KW of any type (as per sample) complete all as specified and directed. Make: Bajaj/CG/USHA/JAGUAR/as per sample.
Supply and fixing in replacement old u/s thermostate for geyser and fixing of new thermostate adjustable between 30 degree to 90 degree celcius of any size /type as per existing (ISI marked) complete all as specified and directed.
Supply and fixing in replacement old u/s indicator lamp and fixing of new indicator lamp of suitable capacity including its electrical connection complete all as specified and directed.
Supply and fixing in replacement of PVC connection heavy duty 450mm long with 2 nuts brass at both ends suitable for hot water for GI pipe 15 mm dia complete all as specified and directed.
S & F in replacement MS anchor fastener heavy duty 12mm dia 10 cm long all as directed.
S & F in replacement plug top, AC 230 Volts, 6 Amps complete all as specified and directed.
S & F in replacement plug top, AC 230 Volts, 16 Amps complete all as specified and directed.
S & F in replacement of PVC conduit medium grade (MMS) with fittings, ISI marked, 25 mm size complete all as specified and directed.
S & F in replacementt of PVC casing & capping medium grade with fittings, ISI marked, 25 mm size complete all as specified and directed.
Supply in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 7 (Inches) complete all as specified and as directed.
Supply in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 6 (Inches) complete all as specified and as directed.
Supply in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 10 (Inches) complete all as specified and as directed.
Supply in replacement of PVC insulated copper conductor cable, FRLSH, single core, 1100 Volts, 1.5 Sq mm with colour coding complete all as specified and directed.
Supply in replacement of PVC insulated copper conductor Cable, FRLSH, single core, 1100 Volts, 2.5 Sq mm with colour coding complete all as specified and directed.
Supply in replacement of PVC insulated copper conductor Cable, FRLSH, single core, 1100 Volts, 4.0 Sq mm with colour coding complete all as specified and directed.
Supply in replacement of PVC insulated copper conductor Cable, FRLSH, single core, 1100 Volts, 6.0 Sq mm with colour coding complete all as specified and directed.
Supply and draw in repairs/replacement submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted.
All as per item no 65 above but on surface PVC casing caping medium grade of 20-25 mm wide, with double locking type, including all accessories complete all as specified and directed.
M&L in repairs/replacement sub main wiring with three single core 10 Sqmm FRLSH copper conductor cable PVC insulated and unsheathed stranded incl drawing through concealed PVC conduit non metallic medium grade(MMS) 30 mm dia with all accessories like bend,Tee , junction concealed on wall incl 01x 10 Sqmm FRLSH PVC insulated unsheathed copper conductor cable as earth wire and 01x10Sqmm FRLSH PVC insulated copper conductor as neutral wire complete all as specified Note- Three run of 10 sq mm and two run of 10 sq mm PVC insulated copper wire and one run of PVC conduit shall be measured as one length.
All as per item no 67 above but on surface PVC casing caping of suitable size medium grade of 30-32 mm wide, with double locking type, including all accessories complete all as specified and directed.
Supply and fixing in repairs/replacement single pole and neutral enclouser with a two pin and earth plug and socket complete with one pole MCB 20 Amps complete all as spd and directed.
S & F in repairs/replacement sheet metal enclosure double door for DBs SPN 4 way 240 V complete double door, flush mounted all as specified and as directed
Supply and fixing in replacement sheet metal enclosure double door for MCB DBs SPN 8 way 240 V, complete flush mounted all as specified and as directed. (Make : L&T Cat No. DBSPN008DD, Schneider, ABB, Havells or equivalent)
S & F in repairs/replacement sheet metal enclosure double door for MCB DBs SPN 12 way 240 V, complete flush mounted all as specified and as directed.
M&L in repairs/replacement sheet metal enclosure for Ekinox TPN DB-VTPN 4 way 415 V, double door , 250 A copper bus bar , IP 43 , including 100 Amp MCCB as incomer as flush mounted complete all as specified and as directed.(Make -Legrand(Series 5077 45 to 48)
S & F in repairs/replacement MCB single pole (SP) 5 to 40 Amps, 240 volts , C curve , AC , 50 Hz ,10 kA complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 15 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as shown on electrical plate No. 3 of SSR part - I , including taking out old U/s complete alll as specified and directed .
Taking down old recess mounting 2' x 2', LED light luminaire 24-36W and refixing same after repair or by replacing required item of reccess light complete all as specified and as directed. (Note: LED driver and surge protection device will be measured and paid separately)
Supply and Fixing in replacement of LED Driver 24-36W with surge protection device of recess mounting 2' x 2', LED light luminaire, IP65, complete all as specified and as directed. Make- CG Cat Pt No- SODRVES-36-600-25W & SRPS-5K-440
Supply and fixing in repair electronic LED driver for wall security light of 15/25 Watt LED complete all as specified and as directed. Make: as per sample
S&F in replacement switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed.
S&F in replacement of switch socket combination 2 in one, 5 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed.
S&F in replacement of switch socket combination 2 in One , 5/6 pin, 5/6/16 Amps flush type complete all as specified and directed.
S & F in replacement of socket out let, 5 pin 5 Amps flush type complete all as specified and directed.
S & F in replacement of switch flush type, 5 Amps, SP, two way complete all as specified and directed.
S & F in replacement of switch bell push flush type 5 Amps complete all as specified and directed.
S & F in repairs/replacement metal flush box 10/12 module complete all as specified and as directed.
S & F in repairs/replacement metal flush box 8 module complete all as specified and as directed.
S & F in repairs/replacement metal flush box 6 module complete all as specifided and directed
S & F in repairs/replacement metal flush box 3 module complete all as specifided and directed
S & F in repairs/replacement white cover plate with frame 10/12 module complete all as specified and as directed.
S & F in repairs/replacement white cover plate with frame 8 module complete all as specifided and directed
S & F in repairs/replacement white cover plate with frame 6 module complete all as specifided and directed
S & F in repairs/replacement white cover plate with frame 3 module complete all as specifided and directed
S&F, in repair, compressor unit of water cooler, storage type 40/80 litres capacity including necessary cutting, welding complete with all fixing accessories as required and as directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after.
M&L for Leakage testing of compressor of water cooler 40/80 ltr capacity by dry nitrogen complete all as specified and directed.
M&L for flushing of the refrigerator system of water cooler 40/80 ltr capacity with dry nitrogen , replacement of capillary tube, strainer and drier of required size and , assembling the system, after applying appropiate vacuum upto (-) 75cm column of mercury, complete all as specified and as directed .
M&L for recharging of gas in compressor of water cooler 40/80 ltr capacity with refrigerant gas R- 22/134 (a) as required and testing the water cooler with satisfactory cooling effects after installing at indicated location complete all as specified and as directed .
S&F, in repair, thermostate ISI marked for water coolers of 40/80 ltrs capacity complete all as specified and directed.
S&F, in repair, Over load relay (OLR) for water coolers of 40/80 ltrs capacity complete all as specified and directed.
S&F, in repair, starting capacitor (SC) 40/60 Mfd for water cooler 40/80 ltr capacity complete all as specified and directed.
S&F, in repair, PVC float valve assembly 15mm dia for water cooler 40/80 ltrs capacity complete all as specified and directed.
S&F, in repair, push tap assembly 15 mm dia chromium plated for water cooler 40/80 ltr capacity complete all as specified and directed.
Rewinding of blower motor of water cooler of 40/80 Litres capacity with super enamelled copper wire as per existing gauge including replacement of old bush and ball bearing by new one, complete all as specified and directed.
S&F, in repair, blower fan motor of water cooler of capacity 40/80 Litres complete all as specified and directed
M&L Repairs to defective portion of body of water cooler of capacity 40/80 Litres in patches (not exc. 0.5 Sqm) complete as required by providing new MS plain black sheet of thickness as per existing with necessary welding complete all as specified and directed .
M&L for Preparation of old painted surfaces of water cooler of 40/80 Litres capacity including compressor and applying one coat of approved synthetic enamel paint to body of water cooler and one coat of black paint to compressor, by using spray painting machine, complete all as specified and directed.
S&F, in repair, compressor unit of refrigerator 180 to 310 litres capacity including necessary cutting welding complete with all fixing accessories as required and as directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after.
M&L for Leakage testing of compressor of refrigerator 180 to 310 litres capacity by dry nitrogen complete all as specified and directed.
M&L for flushing of the refrigerator system of refrigerator 180 to 310 litres capacity with dry nitrogen , replacement of capillary tube strainer and drier by new one of required size, assembling the system, after applying appropiate vacuum upto (-) 75cm column of mercury, complete all as specified and as directed
M&L for recharging of gas in compresssor of refrigerator 180 to 310 litres capacity with refrigerant gas 134 (A) as required and testing the refrigerator with satisfactory cooling effects after installing complete all as specified and directed.
S&F, in repair, thermostate (defrost type), ISI marked for refrigerators 180 to 310 litres capacity complete all as specified and directed
S&F, in repair, Lamp, (screw/pin type) as required suitable for refrigerator of 180 to 310 litres capacity complete all as specified and directed
S&F, in repair, cooling chamber as per existing model for refrigerator of 165 to 310 litres capacity complete all as specified and directed
S&F, in repair, magnetic door Gasket suitable for refrigerator 180 to 310 litres capacity complete all as specified and directed
S&F, in repair, chiiler door suitable for regrigerator 180 to 310 litres capacity complete all as specified and directed
S&F, in repair, chiller tray suitable for regrigerator 180 to 310 litres capacity complete all as specified and directed
S&F, in repair, vegetable/fruit tray suitable for refrigerator 180 to 310 litres capacity complete all as specified and directed
S&F, in repair, Over load relay (OLR) for refrigerators 180 to 310 litres capacity complete all as specified and directed.
S&F, in repair, blower fan motor of 180 to 310 litres capacity Refrigerator complete all as specified and directed .
Servicing in situ of complete out door /indoor unit of Split type AC 1.5 to 2 TR capacity after removing electric connection by cleaning of condensor coil, evaporator coil, blower & motor, air filter, louver, other connected accessories and replacemement of unserviceable screws, nuts,bolts, washers from the body of the ACs by providing new one and making the same perfectly tight and noiseless during operation complete all as specified and directed. Note. Spare/parts, components required will be measured and paid separately under relevant items here-in-after as supply only.
Supply only room sensor suitable for Split type /Window type AC of capacity 1.5 TR to 2 TR ,complete all as specified.
Supply only coil sensor suitable for Split/window type AC of capacity 1.5 TR to 2 TR ,complete all as specified.
Supply only air filter suitable for split type AC of capacity 1.5 TR to 2 TR ,complete all as specified.
S&F, in repair, blower fan motor of Split type AC of capacity 1.5 TR to 2 TR complete all as specified and directed
S&F, in repair, Power Control board (PCB) complete for 1.5 TR to 2 TR split type AC complete all as specified and directed.
S&F, in repair, Outdoor unit condenser coil (copper) complete for 1.5 TR split type AC complete all as specified and directed.
S&F, in repair, Indoor unit cooling coil (copper) complete for 1.5 TR split type AC complete all as specified and directed.
S&F, in repair, sealed compressor unit for Split type AC 1.5 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after.
S&F, in repair, sealed compressor unit for Split type AC 2 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing , flushing of system and charging of gas shall be measured and paid separately under relevant items here in after .
M&L Leakage testing of compressor of Split type AC 1.5 to 2 TR capacity by dry nitrogen complete all as specified and directed .
M&L in repairs/replacement flushing of the refrigerator system ie refrigerant coil of evaporator, condensor and interconnecting copper tube of Split type AC 1.5 TR to 2 TR capacity with dry nitrogen flushing upto vacuum (- 75 cm) column of mercury & replacement of old strainer /drier by new one as per existing size, complete all as specified and directed .
M&L Re-Charging of gas refrigerant R-22 to split type AC of 1.5TR to 2.00 TR capacity on full load, checking automatic cut-out, setting of room temperature and testing complete all as specified and directed .
Servicing in situ of complete window type air conditioner 1.5 TR to 2 TR capacity after removing electric connection by cleaning of condensor coil, evaporator coil, blower & motor ,air filter , louver ,other connected accessories and replacemement of unserviceable screws, nuts,bolts, washers from the body of the ACs by providing new one and making the same perfectly tight and noiseless during operation complete all as specified and directed. Note - Spare/parts components required will be measured and paid separately under relevant items here-in-after as supply only.
Supply only Multi Capacitor 50 Mfd for Split / window type AC capacity 1.5 TR to 2.00 TR, complete all as specified.
S&F, in repair, Power control board ( remote circuit)complete for 1.5 TR to 2 TR window type AC complete all as specified and directed.
Supply only thermostate ISI marked suitable for window type AC capacity 1.5 TR to 2 TR ,complete all as specified.
Supply only air filter suitable for window type AC of capacity 1.5 TR to 2 TR ,complete all as specified.
S&F, in repair, blower fan motor for window type AC of capacity 1.5 TR to 2 TR ,complete all as specified and directed.
S&F, in repair, condenser coil (copper) complete for 1.5 TR Window AC complete all as specified and directed.
S&F, in repair, Cooling coil (copper) complete for 1.5 TR Window type AC complete all as specified and directed.
S&F, in repair, sealed compressor unit for Window type AC 1.5 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing, flushing of refregerator system and charging of gas shall be measured and paid separately under relevant items here in after .
S&F, in repair, sealed compressor unit for Window type AC 2 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing, flushing of refregerator system and charging of gas shall be measured and paid separately under relevant items here in after .
M&L Leakage testing of compressor of Window type AC 1.5 to 2 TR capacity by dry nitrogen complete all as required and directed.
M&Lin repairs/replacement flushing of the refrigerator system ie refrigerant coil of evaporator, condensor and interconnecting copper tube of Window type AC 1.5 TR to2 TR capacity with dry nitrogen flushing upto vacuum (-) 75 cm column of mercury & replacement of old strainer or drier by new one as per existing size, complete all as specified and directed .
M&L in repairs/replacement Preparation of old painted external surfaces of window type AC 1.5TR to 2 TR capacity including compressor and applying one coat of approved synthetic enamel paint to body of window AC and one coat of black paint to compressor, by using spray painting machine, complete all as specified and directed.
M&L Re-Charging of gas refrigerant R-22 to 1.5TR to 2.00 TR capacity Window type AC on full load, checking automatic cut-out and setting of room temp and testing complete all as specified and directed .
S&F, in repair, compressor unit for Deep Freezer capacity 320 Ltr including necessary cutting welding complete with all fixing accessories as required and as directed. Note. Leakage testing , flushing of refregerator system and charging of gas shall be measured and paid separately under relevant items here in after.
M&L for Leakage testing of compressor of deep freezer 320 ltr capacity by dry nitrogen complete all as specified and directed.
M&L in repairs/replacement flushing of the refrigerator system of deep freezer 320 ltr capacity with dry nitrogen and replacement of old capillary tube strainer and drier by new one of required size, assembling the system, after applying appropiate vacuum upto (-) 75cm column of mercury complete all as specified and as directed .
M&L in repairs/replacement recharging of gas in compresssor of Deep freezer 320 litre capacity with refrigerant gas R-22 as required and testing the deep freezer with satisfactory cooling effects after installing at indicated location complete all as required and directed .
S&F, in repair, over load relay (OLR) for Deep Freezer of 320 Ltrs capacity complete all as specified and directed.
S&F, in repair, starting capacitor 100/120 Mfd for Deep Freezer of 320 Ltrs capacity complete all as specified and directed.
S&F, in repair, thermostate suitable for Deep Freezer of 320 Ltrs capacity, complete all as specified and directed.
S&F, in repair, blower fan motor of Deep Freezer of 320 Litres capacity complete all as specified and directed.
S&F, in repair, voltage stabilizer of capacity 1 KVA ,220 V for water coolers and deep freezers etc. complete all as specified and directed.
Taking down and complete servicing of walk in freezer refrigeration unit air cooled with semi hermatic condensing units of make blue star complete all as specified and directed.
Supply and filling of refrigerant gas R-404R for walk in freezer refrigeration unit air cooled with semi hermatic condensing unit complete all as specified and directed.
Supply and fixing in replacement three phase relay (as per existing model/make in control/display panel of walk in freezer) complete all as specified and directed.
Supply and fixing in replacement 3/4 phase power contactor (as per existing model/make L&T NC1 1801 in control/display panel of walk in freezer) complete all as specified and directed.
S&F, in repair, voltage stabilizer of capacity 3 KVA ,220 V for window ac and split ac complete all as specified and directed.
Anil Kumar Sarmah (BID ID -3116311)
D G Corporation (BID ID -3119269)
M/s Brahamaputra Wood Industries (BID ID -3126995)
AVASANA SOLUTIONS PRIVATE LIMITED (BID ID -3127134)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .