Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC | ₹3.7 Cr Quoted ₹3.8 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹4.1 Cr+₹33.6 L (8.93%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | ₹4.1 Cr+₹33.6 L (8.93%) | L2 | Rejected-Finance Not being lowest |
| 3 | Rejected-Technical VILL BAREGAON PO CHAK CHAKA BAZAR DIST BARPE | BARPETA | ASSAM | 781301 | - | - | Rejected-Technical Firm not fulfills NIT criteria as having advers remark in WLR |
Tender Value
Refer Docs
EMD Value
₹4.5 L
Closing Date
12 Mar 2022, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone Spread Eagle Falls Shillong-793011 Meghalaya
RENOVATION TO OLD PERMANENT AND TEMPORARY BUILDINGS OF KV KUNJABAN AT AGARTALA UNDER AGE I AGARTALA
2022_MES_506334_1
CESZ/AGR/30 OF 2021-22
Open Tender
Civil Works
Item Rate
365 days
Kunjaban Agartala
As per NIT
2 documents required · 2 mandatory
₹2,000
Yes
AGE(I) AGARTALA
₹4.5 L
Yes
8 Apr 2022
7 Feb 2022
14 Mar 2022
7 Feb 2022
12 Mar 2022
28 Feb 2022
8 Feb 2022 - 15 Feb 2022
Amount
Surface excavation in soft/loose soil n exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
Excavation over areas not exc 1.5m deep and getting out in soft and loose soil complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide n exc 1.5 m deep in soft/ loose soil for foundation etc or for shaft, wells, manholes etc n exc 10 sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide n exc 1.5 m deep in hard/dense soil for foundation etc or for shaft, wells, manholes etc n exc 10 sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed.
Returning ,filling in including spreading ,levelling watering and well ramming in soft/loose soil in layers n exc 25 cm thick complete all as specified and directed
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed
Surface dressing n exc 15cm deep in soft/loose soil complete all as specified and directed.
M&L for sand filling under floors or in foundation including spreading, levelling watering and well ramming in layers complete all as specified and directed.
Supply and spreading sand cushioning for under ground cable protection with dry fine river sand complete all as specified and directed. Note: Punned thickness shall be measured and paid.
Forming embankments including raising or lowering earth spreading in layers not exc 30 cm thick watering ,ramming and rolling and finished to required size and shape etc n exc 1.5 m high from base by using soil complete all as specified and directed
Removing excavated soil not exceeding 50 m distance and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and directed .
M&L for hardcore of broken stones of gauge n exc 63 mm , deposited, spread and levelled in layers n exc 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M& L Cement concrete 1:3:6 Type C-2 (using 40 mm graded stone aggregate) ,in foundations, filling and mass concrete complete all as specified and directed
M& L Cement concrete 1:4:8 Type D 2 (using 40 mm graded stone aggregate) ,in foundations, filling and mass concrete complete all as specified and directed
Cement concrete 1:3:6 Type C 2 (using 40 mm graded stone aggregate) as in suface channels and drains complete all as specified and directed
Cement concrete 1:2:4 Type B 2 (using 40 mm graded stone aggregate) as in suface channels and drains complete all as specified and directed
Providing cement concrete 1:2:4 Type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, including weathering, slightly rounded or chamfered angles and throating, as directedcomplete all as specified and directed
Reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
Reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
Reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate)as in columns, pillars, piers, posts and struts complete all as specified and directed
Extra for forming fair finished drain or channel 30CM inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed
Supply only integral water proofing compound
M &L Brickwork with subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 complete all as specified and directed
M&L Brickwork with subclass 'B' bricks, old size brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
Cutting holes in to brick wall for inserting bold fast & making good dismantled portion in CM (1:3) or PCC (1:2:4) type B1, exe half brick but not exe 1 brick complete all as specified and directed
M&L Continuous brick edging; using sub class 'B' brick (old size) with width equal to the width of the brick; laid dry on end vertically complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; rough finished surfaces of concrete flat complete all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete flat complete all as specified and directed
Formwork to sides of square ,rectangular or polygonal pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete flat complete all as specified and directed
Material and labour II nd class hardwood plain fillets square, rectangular or triangular in sectional area exc 6 Sqcm & n. exc 13 Sqcm clean swan secured with nails complete all as specified and directed
Material and labour II nd class hardwood plain fillets square, rectangular or triangular in sectional area exc 13 Sqcm & n. exc 25 Sqcm clean swan secured with nails complete all as specified and directed.
M&L for 20 mm thick second class hard wood boarding fixed with nails in any situation (except flooring and skirting), planned, both sides, with butt joints as in eaves board complete all as specified and directed.
S&F 35mm thick Factory made Flush shutter solid core construction with particle board core and plywood face panels commercial type on both sides complete all as specified and directed.
Taking down chowkat with shutter/without taking off shutter from the frame n exe 1.50 sq.m each complete all as specified and directed.
Taking down chowkat with shutter/without taking off shutter from the frame exe 1.50 sq m each but n. exc 4 sq. m each. complete all as specified and directed.
S&F 125 mm long brass barrel tower bolts, with cast or sheet barrel and rolled or cast boots and fixed complete all as specified and directed.
S&F 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
S&F Mild steel sliding door bolts of size 300mm length of bolt, plate type, stove enamelled black with bright bolt not less than 12 mm dia with nad including a minimum of 6 bolts and nuts, four on bolt plate & two on staple platecomplete all as specified and directed.
S&F continious (Piano) hinges, mild steel, bright finish or electro galvanised of 30mm width (when open) complete all as specified and directed.
Supply & Fix extruded brass handles, 150 mm fabricated type, polished complete all as specified and directed.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and directed.
Supply & Fix 40mm dia copboard knobs fixed with nut, screw and washer of brass polished complete all as specified and directed.
Supply & Fix 100 mm aluminium anodised Hasp and staple, safety type,including bolt to hinge plate fixed with screws complete all as specified and directed.
Supply & Fix brass chromium plated tubular towel rail, 20 mm dia, D type, 60cm long between flangs complete all as specified and directed.
S & F framed brackets of angles or tees for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc incl all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F framed work such as grills gratings, etc., with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed baluster; walk ways; railings; framed work or water tanks and similar work conforming to Fe 290 gde E 165 complete all as specified and directed
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed
M&L Mild steel TMT bars of Grade 500D 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars of Grade 500D 5mm dia and over upto and including 10mm dia cut to length, bent to shape required in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
M&L roof trusses framed, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam,tee,angle,channel or flat sections) including distance pieces, cleats FE- 410-W (Gde-E-250) quality -B etc. complete all as specified and directed
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hanging; also fastening conforming to grade Fe-410-W or E -250 quality A complete all as specified and directed
M&L steel work in tubular trusses including vertical post, special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 - 1979 grade St - 240 complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed
S&F Galvanised 2 strand steel barbed wire 2.24mm dia PVC coated steel barbed wire with 2mm dia barbs at 75mm spacing & straining & fixing to any type of standard rails straining bolt including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.etc as directed (each line wire to be measured) complete all as specified and directed
S&F pressed steel frames for doors of size 105x60 mm, 1.6mm thick with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed
Supply only chain link MS galvanised fencing any size or type complete all as specified and directed
M & L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile stenght of 550 Mpa as in roof covering/claddiing to wall , fixed with self tapping screws complete all as specified and directed
S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridge, gutter etc fixed with self tapping screws complete all as specified and directed
Supply & Fix 18/19 mm thick prelaminated particle board (prelaminated on one side) with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work / shutters complete all as specified and directed
Extra over rates of block board or veneered particle board for external teak wood lipping, 6 mm thick fixed with nails complete all as specified and directed
M&L machine cut kota stone slab flooring 20 mm thick over screed base including cutting & polishing etc complete all as specified and directed
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed
M&L for 100mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed
Material and labour for 40 mm thick PCC (1:2:4) type B-1 (using 20mm graded stone agg) as in repair work for floor finish complete all as specified and directed
Material and labour for 40 mm thick PCC (1:2:4) type B-1 (using 20mm graded stone agg) as coping complete all as specified and directed
M&L 25 thick PCC (1:2:4) type B-O (using 12.50 mm graded stone aggregate) as in floor finished rough complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping clean & washing down with water to remove dust etc and brushing neat cement slurry at the rate of 3 kg of cement per sqm complete all as specified and directed
M&L for joint free non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm in floors, set & jointed in neat cement slurry & pointed with coloured cement to match complete all as specified and directed
M & L for Chequered cement concrete tiles 20cm x20cm x 25mm thick,set, jointed andpointed in neat cement slurry in floors with grey pgment cement and pigments complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding,(but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L 10 mm thick rendering in cm (1:4) on other than fair faces of brick work finished even & smooth without using extra cement complete all as specified and directed.
M&L 15 mm thick rendering in cm (1:3) on concrete or brick surfaces with integral water proofing compound @ 3% by wt of cement, (Water proofing compound measured & paid separately) finished even and fair complete all as specified and directed
M & L for 5 mm thick rendering in CM (1:3) on fair face of concrete surfaces as in ceiling etc finished even and smooth without using extra cement complete all as specified and directed
Plastering 15 mm thick in cm 1:4 on fair face of brick work or concrete surfaces finished fair even and smooth without using extra cement complete all as specified and directed
M&L rendering 10 mm thick in cement plaster (1:4) on fair faces of brick work or concrete surfaces is to be finished even and smooth without using extra cement complete all as specified and directed
M&L for screed bed or bedding layer of morter 15 mm thick for laying floor finishes of CM 1:4 without using extra cement complete all as specified and directed
M&L 10 mm thick screed bed or bedding layer of mortar in cm 1:4 for fixing of wall tiles on rough finished surfaces complete all as specified and directed.
Taking down cement plaster on brick concrete surfaces including racking out joints hacking for key, scrubbing down with, water etc without using extra cement complete all as specified and directed
Material and labour for Two Coats of Cement Base Paint over a coat of primer including preparation of newly plastered surfaces complete all as specified and directed
M & L for Preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of chalk whitening complete all as specified and directed
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M & L preparation of old steel surface and applying one coat of synthetic enamel paint surface exc 10 cm width or girth over one coat of red oxide primer complete all as specified and directed
Preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed
Preparation of new steel surfaces of any description, n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M & L preparation of old steel surface and applying one coat of synthetic enamel paint surface n.exc 10 cm width or girth over one coat of red oxide primer complete all as specified and directed
Supply and fixing GI steel tubing light grade for protection of cable on poles, under road crossing etc of 40 mm dia complete all as specified and as directed.
S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and as directed.
S&F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and as directed.
S&F 25mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and as directed.
Taking up or down 15mm bore steel water tubing & connections,including cleaning or refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm bore steel water tubing & connections,including cleaning or refixing or removal to store complete all as specified and as directed.
S&F low density polythene (LDPE) pipes of pressure rating 6 Kg/Sq cm bore of tube 32 mm for waste pipe of WHB sinks etc complete all as specified and as directed.
S&F in repair 15mm bore fancy type chromium plated bib taps with crutch of butterfly handle screwed down for iron pipes complete all as specified and as directed.
S&F in repair pillar taps 15mm dia bore fancy type with capstain heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F 15mm bore stop valve fancy type,chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F 15mm bore concealed stop valve fancy type,chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
S & F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. ( Minimum weight 60 gms ) complete all as specified and as directed.
S&F pvc connector 15mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
Supply and fix 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring loints, fixed to walls complete all as specified and as directed.
Supply and fix 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring loints, fixed to walls complete all as specified and as directed.
Supply and fix 75 mm bore PVC (SWR) bends in any types complete all as specified and as directed.
Supply and fix 110 mm bore PVC (SWR) bends in any types complete all as specified and as directed.
Supply and fix 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed.
Taking out existing nahani trap 100mm bore and supply and fix 100mm bore CI Nahani trap with chromium plated grating including all joints & making good to floor & tested complete, jointed to waste pipe all as specified and as directed.
S&F in repairs Vitreous China, semi pedestal pattern (anglo Indian type) with 'P' trap white/coloured incl seat cover complete taking down old seat, including connection to drain (or outgoing pipe) and to flushing pipe,antisyphonage pipe, etc. complete excluding fixing bolts, flushing cistern and flush pipe complete all as specified and directed
Supply & Fix in repairs vitreous china squatting pan " Orissa Pattern" size 580 x 440 mm white with integral foot rest including provision of lime concrete bedding (excluding flushing cistern and flush pipe) complete all as specified and as directed.
S&F in repairs 10 Ltr capacity PVC valveless, syphonic action type Flushing Cistern, low level white with inlet ball valve float & handle including brackets & connection to pipes complete all as specified and as directed.
Supply and fix sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed.
Supply and fix in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed.
S & F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe ) urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement ; fixing automatic flushing cistern with brackets, flush pipe, grating and unoin for discharge pipe ( Exclusive of fixing supply pipe to flushing cistern , trap and waste pipe ) complete all as specified and fixed in repairs complete all as specified and as directed.
Supply and fix in repairs brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe or union complete all as specified and as directed.
Demolition of brick work built in cement mortar complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of AC sheet corrugated / CGI corrugated sheets in roofing any gauge and any thickness including ridge, valley/gutter etc. complete all as specified and as directed.
Dismantling wall / ceiling board (fibre pulp insulation) or insulation boards any thickness including cover fillets complete all as specified and as directed.
Dismantling fencing wire mesh any type complete all as specified and as directed.
Dismantling posts or struts (Wood, steel or RCC) any section including taking out embedded portion and making good to disturbed ground as in natural ground complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes,jointed in cemented mortar and taking out of trenches of 100 mm dia internal dia bore drain pipes complete all as specified and as directed.
M&L PCC 1:2:4 (using 12.5mm graded agg) in roof kerbs, rounded or chamfered or haunching in chajjas to prevent water seepage into brick walls including necessary formwork and scaffolding up to a height of 8m complete all as specified and as directed.
S&F for anodised aluminium partition, fixed type without sash bar, aluminum section with members of shutters of section 38X12mm and other standered weighing 0.55Kg/M including 5.50 mm thick tinted glass with necessary rubber beading gasket fixed with necessary joining cleats,glazing clips, rubber packing, anodised aluminium snap beading screws etc complete all as specified and directed.
S&F three track aluminum powder coated sliding window with three sliding shutter , the size of outer frame three track 100 x 37x 1.50mm ( using two track for glazed window shutter and one track for wire gauged ) , the section shutter size 37x 18x 1.2mm)and glazing with 5 mm thick Transparency glass of poly carbone including all-around suitable rubber gasket and stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed on aluminum flat and inserted in the frame of shutter with tracking arrangement each sliding window shall be provided with one number handle including locking arrangement & 2 numbers’s sliding rollers of nylon with including all necessary fittings complete all as specified and as directed.
S&F fixed type powder coated aluminium ventilators with provision of movable slanting Transparent glass stripps 75mm wide and 5 mm thick of poly carbone including all necessary fittings arrangement complete using aluminium section 100x44.45x1.5mm thick etc in frame complete all as specified and as directed.
S&F exposed GI powder coated snap grid frame for false ceiling 600 x 600 mm size of wall angle 25 x 25 x 0.35 mm size of cross sec 24 x 38 x 0.70 mm with 2 mm dia GI suspender including supply and fixing of 4 mm thick E board in false ceiling fixing arrangement from steel tress any type of tress comback with two coats of washable distemper over a coat of cement prime on exposed surfaces all as specified complete all as specified and as directed.
M&L for glossy coloured HD Digital Tiles (Joint free) tiles (300X600mm) 7 mm thick, finish as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 10mm thick cement plaster in cement mortar 1:3 complete all as specified and as directed.
M&L prepolished PCC tiles 30 cm x 30 cm x 20-22 mm thick, set jointed and maint cement slurry in floors as foot/paving complete all as specified and directed.
S&F PVC half round pipe, 140 mm (supplied in 3 mtr, support bracket stop end outlet as in EAVE GUTTER complete all as specified and as directed.
M&L applying two coats of exterior emulsion antifungus wheather coat on old / new plastered surfaces of wall over a coat of primer after applying a thin layer of wall care putty including removal of existing treatment and preparation of old or new plastered surfaces to receive paint complete all as specified and directed by Engr-in-Charge.
M&L complete removal of internal wall surfaces by scrapping down and applying a thin layer of wall care putty and applying two coats of plastic emulsion antifungus paint over a coat of primer on old/new plaster surfaces to receive paint complete all as specified and directed by Engr - in - Charge.
S&F 550 x 400 x 140 mm table top basin snow white etc. necessary fittings and fixture complete all as specified and directed by Engr-in-Charge .
S&F brass CP central hole basin mixer connecting pipe of 15mm dia complete all as specified and as directed.
S&F 15 mm bore brass CP two way bib cock with single knob and wall flange complete all as specified and as directed.
S&F 15mm bore health faucet chromium plated ABS body with wall hook and 1 metre SS braided rubber hose pipe incl all accessaries complete all as specified and as directed.
S&F CP Liquid Soap dispenser complete all as specified and directed.
Chipping of existing deteriorated damaged & lose concrete from the external surface of the structure by mechanical means or using wire brush/chisel/hammer or low empact high frequency hammer etc without damaged the structure .Further cleaning and exposing the sound concrete using wire brush including removing the loose scale of corrosion etc from the exposed reinforcement to make it free from dust,residues etc.The rate shall also include disposal of waste/rubble/malwa from site outside MD Land as directed by the Engr-in-Charge along with lead and lift if any including standard steel scaffolding upto a height of 11 M. Note : The above treatment will be done in presence of company authorised person complete all as specified and directed.
Removal of all rust materials,cleaned the corroded reinforcement by wire brush,then cleaned with air blower/water jet &finally cleaned by rust removing agent as per technical specification ,as per manufacturer's recommendation and as per the direction of Engr-in-Charge .The rate inclusive of labours,materials,tools &tackles,all complete including standard steel scaffolding upto a height of 11 M complete all as specified and directed. Note : The above treatment will be done in presence of company authorised person .
Providing fitting fixing new reinforcement as required as per site condition and as per the direction of Engr-in-Charge.The rate inclusive of labours,materials,tools &tackles,all complete including standard steel scaffolding upto a height of 11 M. Note : The above treatment will be done in presence of company authorised person complete all as specified and directed.
Surface cleaning,application of zinc rich epoxy based primer coat on steel surface / Reinforcement,2 coat shall be applied as per manufacturer's recommendation and as per technical specification and as per the direction of Engr-in-Charge,including labour,materials,tools,tackles,all as complete including standard steel scaffolding upto a height of 11 M . Note : The above treatment will be done in presence of company authorised person. Make of zinc rich epoxy based primer coat complete all as specified and directed.
Surface preparation by mechanically or manually,cleaning,application of primer/bond coat followed by 3-Part Thixotropic epoxy resin based patching mortar on damaged concrete surface up to 20mm average thickness as per manufacturer's recommendation and technical specification and as per the direction of Engr-in-Charge,including labour,materials,tools,tackles,curing all complete including standard steel scaffolding upto a height of 11 M . Note : The above treatment will be done in presence of company authorised person.
Supply and apply a polymer based High Performance water resistant bonding agent and mortar bond coat on the prepared concrete surface as per specificaton,as per recommendation & as per the direction of Engr-in-Charge.The rate inclusive of all sorts of material,labour,tools &tackles complete including standard steel scaffolding upto a height of 11 M. Note : The above treatment will be done in presence of company authorised person. Make of water resistant bonding agent and mortar bond coat complete all as specified and directed.
M&L for 25mm thick(avg thickness) Guniting concrete surface using mechanical means with single component, shrinkage control polymer modified/ fixed reinforced, structrural grade cementitious repair mortar having compressive strength of 45 N/sqmm, flexural strength of 7N/sqmm and tensile strength of 2.5N/sqmm at 28 days all as per manufactures recommendation and technical specification and as per direction of Engr-in-charge incl standard steel scaffolding upto a height of 6m. NOTE: The above treatment will be done in presence of company authorised person. Make of single component, shrinkage control polymer modifird/ fixed reinforced, structrucal grade cementitious repair mortar complete all as specified and directed.
Providing fitting, fixing necessary good quality reusable water tight form work for fair finished surfaces with suitable screwing arrangements to the structure,as required as per site condition ,as per specification & as per the direction of Engr-in-Charge ,as well as deshuttering .The rate inclusive all sorts of material,labours,tools & tackles completeincluding standard steel scaffolding upto a height of 11 M complete all as specified and directed. Note : The above treatment will be done in presence of company authorised person
Supply ,mixing and placement of ready to use non shrink ,cementitious free flow micro concrete upto required thickness at designated area, as per specification,as per recommendation & as per including standard steel scaffolding upto a height of 6 M complete all as specified and directed. Note : The above treatment will be done in presence of company authorised person
M&L for filleting in any position and to any shape in cement lime mortar 1:1:6 including all mitres, stops, etc Exc. 25 but nexc. 50 sqcm complete all as specified and directed.
M&L for preparing existing black top surface by brushing wire brushes by removing caked mud etc, sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc and M&L for applying evenly a priming tack coat with bituminous primer (VG-10) at 10 Kg per 10 Sqm using paving bituminous complete all as specified and directed.
Material and labour for Bituminous premix semi dense asphaltic concrete (SDAC), 40mm consolidated thickness with 5.5 % binder content of paving bitumen by weight of total mix using VG-30 grade bitumen, rolled and compacted to required camber and gradient complete using mechanical paver and rolled using power roller 8 to 12 tonne capacity complete all as specified and directed. Note : The contractor's quoted rates shall also be deemed to include the following element: (i) In case of variation in the binder content as per approved design mix in comparison with the binder content as specified above, the variation in qty of binder content on lesser side shall be adjusted through supply only rate of Bitumen VG-30.
Material and labour for painting lines, dashes, Arrows, letters etc on roads pavements and the like exc 10 cm wide applying 2.5 mm thick thermoplastic road marking painting of specified shade/ colour etc., either continuous or broken lines, to the required width and length over the existing painted surface/ new bituminous surface with solvent based road marking paint using semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass bead dispenser, propane tank heater and profile shoe heater driven by experienced operator on road including all materials, labour, T&P and cleaning the road surface of dirt, seals, oil, gease and foreign materials etc., complete all as specified and as directed.(Note : Thermoplastic road marking paint shall be applied as per manufacturer’s instructions along with MORTH technology and speciality.)”
Taking down carefully aluminum/ copper point wiring (light, fan, socket or power) complete (excluding sunken box) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and segregating serviceable fittings & set aside for reuse in the work and making good to disturbed surfaces of walls, floors, ceilings etc. complete all as specified and as directed.
Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed.
Material & Labour for point wiring complete with cable PVC insulated, unsheathed, 1100V grade conforming to IS for one way SP, 5A with 1.5 Sqmm of cable of nominal area multistranded copper conductor drawn through and including 20mm PVC casing capping including accessories on wall/floor/ceiling ( on surface) etc with 16G MS pressed steel terminal box with 2.8 mm thick laminated sheet cover for mounting switch, socket outlet etc complete with all accessories/fittings including PVC insulated continuous muli standred copper earth wire (1.5 Sqmm) for One light /fan point/ bell point controlled by one way one switch and connected to common earth dolly complete all as specified and as directed.
Material & Labour for point wiring complete with cable PVC insulated, unsheathed, 1100V grade conforming to IS for one way SP, 5A with 1.5 Sqmm of cable of nominal area multistranded copper conductor drawn through and including 20mm PVC casing capping including accessories on wall/floor/ceiling ( on surface) etc with 16G MS pressed steel terminal box with 2.8 mm thick laminated sheet cover for mounting switch, socket outlet etc complete with all accessories/fittings including PVC insulated continuous muli standred copper earth wire (1.5 Sqmm) for one 3 Pin 5/6 Amp socket outlet on same board with other switches and connected to common earth dolly complete all as specified and as directed.
Material & Labour for point wiring complete with cable PVC insulated, unsheathed, 1100V grade conforming to IS for one way SP, 5A with 1.5 Sqmm of cable of nominal area multistranded copper conductor drawn through and including 20mm PVC casing capping including accessories on wall/floor/ceiling ( on surface) etc with 16G MS pressed steel terminal box with 2.8 mm thick laminated sheet cover for mounting switch, socket outlet etc complete with all accessories/fittings including PVC insulated continuous muli standred copper earth wire (1.5 Sqmm) for one 3 Pin 5/6 Amp socket outlet on independent board and connected to common earth dolly complete all as specified and as directed.
Material & Labour for point wiring complete with cable PVC insulated, unsheathed, 1100V grade conforming to IS for one way SP, 5A with 2.5 Sqmm of cable of nominal area multistranded copper conductor drawn through and including 20mm PVC casing capping including accessories on wall/floor/ceiling ( on surface) etc with 16G MS pressed steel terminal box with 2.8 mm thick laminated sheet cover for mounting switch, socket outlet etc complete with all accessories/fittings including PVC insulated continuous muli standred copper earth wire (1.5 Sqmm) for one 3 Pin 15/16 amps socket outlet on independent board and connected to common earth dolly complete all as specified and as directed.
Material and Labour for sub main wiring using two single core PVC insulated, PVC sheathed stranded copper conductor (FRLS) cable of size 4 Sq mm unsheathed drawn in and including PVC caping casing including accessories in surface to wall/floor/ceiling etc and 1.5 Sq mm PVC insulated unsheathed copper conductor as continuous earth continuity conductor drawn in complete all as directed and specified.
Material and Labour for sub main wiring using two single core PVC insulated, PVC sheathed stranded copper conductor (FRLS) cable of size 6 Sq mm unsheathed drawn in and including PVC rigid conduit including accessories in surface to wall/floor/ceiling etc and 2.5 Sq mm PVC insulated unsheathed copper conductor as continuous earth continuity conductor drawn in complete all as directed and specified.
Supply & fix switch piano flush type 5/6 Amps single pole one way complete all as specified and as directed. .
Supply & fix Switch socket combination, 3/5 pin, 5/6 Amp flush type complete all as specified and as directed.
Supply & fix Switch socket combination 2 in 1, 3 Pin, 5/6 Amp and 15/16 Amp flush type universal complete all as specified and as directed.
Taking down and supply and fix stepped type electronics fan regulator on the existing phenolic laminated sheet etc complete all as specified and as directed.
Taking down and supply and fix Ceiling rose 3 Terminal/PVC/ Polycarbonate, isolated body complete all as specified and as directed.
Material and Labour for Bell push flush type 5 Amps complete all as specified and directed.
Taking down and supply and fix Bell, AC 230 volts, single pole complete all as specified and as directed.
Material and Labour sheet metal enclosure for double door DBs using MCB with 100/120 Amps rated bus/link bar of 4 way 240V including taking down unserviceable one complete all as specified and as directed. .
Material and Labour sheet metal enclosure for double door DBs using MCB with 100/120 Amps rated bus/link bar of 8 way 240V including taking down unserviceable one complete all as specified and as directed.
Taking down and Material and Labour for wall mounted Busbar chamber TPN (4 bar) 63 Amp rated, 415 volt, 8 way complete all as specified and as directed.
Supply & fix MCB SPN 6 to 32 Amps 230 Volt 'C' Curve, 10 KA complete all as specified and as directed.
Supply & fix MCB SP 6 to 32 Amps 230 Volt 'B' Curve, 10 KA complete all as specified and as directed.
Material and Labour single pole and Neutral enclosure with a two pin and earth plug and socket 15 Amp complete with one single pole MCB 20 Amps including taking down old one complete all as directed and specified.
Taking down and Material and Labour for UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core laid in trenches or fixed to walls including end termination fixing with lugs and nut bolts complete all as specified and directed.
Taking down and Material and Labour for UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core laid in trenches or fixed to walls including end termination fixing with lugs and nut bolts complete all as specified and directed.
Taking down and Material and Labour for UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core laid in trenches or fixed to walls including end termination fixing with lugs and nut bolts complete all as specified and directed.
Taking down and Material and Labour for UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core laid in trenches or fixed to walls including end termination fixing with lugs and nut bolts complete all as specified and directed.
Supply & fix bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed.
Supply and fixing LED tube light fittings box type luminairies with and including 1 x 20 watts LED tube complete with energy savings T8, recess/surfaces mounted powder coated with connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible cable of 0.75 sqmm 3 core copper conductor from ceiling rose to light fittings complete all as specified and as directed.
Taking down and Supply , fixing and testing in replacement of new generation energy saving and environmental friendly long life Building security light LED 45 watt, CRI>70, PF>.95, working voltage 140-270 volt AC, 50 HZ, IP66, lumen output 9000 lumen, colour temperature 5700k, luminous efficiency not less than 100 lumen/watt, including elctronic driver (SMPS based constant current supply with lowed THD, output oen/short circuit protection, phae to phase proctection, surge voltage protection etc made up of pressure dia cast aluminium housing having IP66 protection and finishining epoxy powder coated grey colour phospho chromate treatment with all accessories and connecting up all as specified and directed. Note : Test certificate in support of the technical parameters of the light fittings is to be submitted in original to the Engineer- in -charge by the contractor.
Taking down and supply and fix Digital time switch 40 Amp, 3 pole with contractor and MCB TP 40 Amp including enclosure complete all as specified and as directed.
Supply and fixing loop in- loop out fuse junction box of internal dimention 250 x 200 x 100mm made of FRP sheet with weather proof canopy and locking screw fitted with and including 6 Amp MCB - 01 No, 50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing , mounted in the box, fixing on street pole/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt including taking down old unserviceable junction box all as specified and directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32 x 6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron wire of size 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed.
Supply & fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanized iron or steel wire complete all as specified and directed.
Material & labour for replacement of rusted/corroted security light bracket made out of GI pipe of light grade 1.2 RMx40mm dia and 0.3RM x32 mm dia at one end for inserting of light fitting, properly shaped, bended, & fixed on the pole through MS flat by nut,bolt & washer of suitable sizes incl dismantling the old unserviceable existing one complete all as specified and directed.
Taking down carefully old unserviceable Ceiling fan/Exhaust fan/Wall mounted fan of any sizes from site for safe custody for refixing complete all as specified and directed.
Hanging or Refixing of Ceiling Fan/Exhaust fan/Wall mounted fan any size including provision of suitable flexible cable as required from ceiling rose or connector to fan complete all as specified and directed.
Rajan Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .