Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance OLYMPIA PLATINA PLOT NO 33B SOUTH PHASE GUINDY CHENNAI 600032 | CHENNAI | CHENNAI | TAMIL NADU | 600032 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
23 Dec 2020, 3:00 pmClosed
Deputy General Manager (Maint)
Indian Oil Corporation Ltd Western Region Pipelines Koyali, PO - Jawahar Nagar, Vadodara - 391320
Annual Maintenance Contract for Emerson make Uninterrupted Power Supply (UPS) system installed at 08 nos. of KSPL MOV locations under WRPL, Koyali Base
2020_WRKYL_126029_1
TSKOY202127
Single
Electrical Works
Works
730 days
WRPL, KOYALI
Please refer Tender documents.
10 documents required · 10 mandatory
Exempted
29 Jan 2021
27 Oct 2020
24 Dec 2020
27 Oct 2020
23 Dec 2020
27 Oct 2020
Amount
A. Works to be carried out under Perventive Maintenance Visit
"Two Pre scheduled Half yearly preventive maintenance of the Emersion UPS of Hipulse D 10kVA (Sr No: P1705HIPD484, P1705HIPD486, P1705HIPD482, P1705HIPD481, P1705HIPD488, P1705HIPD487, P1705HIPD485, P1705HIPD483) installed at KSPL MOV Locations under WRPL, Koyali Base, which include the following works: a) Cleaning up of Unit, Visual Inspection to check any deformation as per the instruction of E-I-C. b) Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current as per the instruction of E-I-C. c) Checking and Adjustment (If needed) of Control parameters on different PCBs as per the instruction of E-I-C. d) Tightness of all connection, if shutdown possible as per the instruction of E-I-C. e) Functional checking up of Rectifier section as per the instruction of E-I-C. f) Functional checking up of Inverter section as per the instruction of E-I-C. g) Functional checking up of Static Switch section as per the instruction of E-I-C. h) Perform operational test of the system including unit transfer and battery discharge as per the instruction of E-I-C. i) Install or perform Engineering Field changes Notices (FCN) as necessary as per the instruction of E-I-C The above jobs shall be including cost of transportation of materials, consumables & spare parts (excluding the cost of spares specifically mentioned in the SCC), as may be deemed necessary." Guaranteed 2 hour on-site response, 6days/week. 8 hours/day Includes PCBs used in the equipment Includes unlimited Breakdown calls Includes labour and travel coverage 6days/week and 8hours/day 6 hours turnaround time in case of major complaints provided excluded spares availability
B. Spares not covered under Perventive Maintenance Visit
Capacitor, Panel Mounting, Polypropylene film, Radial, 10uF, 450 Vac, +/- 5 %, -25°C to +85°C, D 30 X H 68 mm, Double Faston, RoHS
Capacitor, Leaded, Metalised Polypropylene , Mountig ON IGBT, 0.68 uF, 1250 Vdc, ±10%, Polypropylene Film, -40° to +85°C, Pitch 8.5 mm, 20 X 36 X 42 X 25.5 mm
Capacitor, Panel Mounting, Polypropylene film, Threaded Stud M12, 3 X 16.5 uF, 440 Vac, 3 kvar, D 75 X H 195 mm, Snap Fit
Capacitor, Panel Mounted, Aluminum Electrolytic, Radial, 4700 uF, 350 Vdc, ±20%, -40° to +85°C, D 76 x 146 mm, Screw
Diode SCR, Module Heat Sink Mountable, Power, 95 Amp RMS, 60 Amp Average, 1600 V
Fan, Centrifugal, 230 Vac, 1 Phase, 50 Hz, 335.46 CFM, 2500 RPM, Ball Bearing, 50 Deg C, Plastic, 190 X 68.5 mm
Fuse, Stud Mount, Cartridge Blade , Semiconductor, 110 Amp, 690 Vac, 6500 Amp Sq.Sec at 690 V, 94 mm L x 31.8 mm W
Fuse, No lead, Glass cartridge, Fast acting, 1 Amp, 250 Vac, 5 mm x 20 mm
Fuse, No lead, Glass cartridge, Fast acting, 2 Amp, 250 Vac, 5 mm x 20 mm
Fuse, No lead, Glass cartridge, Fast acting, 4 Amp, 250 Vac, 5 mm x 20 mm
Fuse, No lead, Glass cartridge, Fast acting, 500 MiliAmp, 250 Vac, 5 mm x 20 mm
IGBT, Dual module, , 242 Amp, 1200 V, , , D56,
Relay, 10 Amp AC, 250 Vac, 28 Vdc, 780 Ohm, 3 Form C, Sealed, 35 X 35 X 54.8 mm
Thyristor, Heatsink Mounted, Dual, 95 Amp RMS, 55 Amp Average, 1800 V
Transformer, Control, Isolation, Copper, PRI - 0 - 220 V - 415 V, SEC1 - 0 - 18 V, SEC2 - 9 V - 0 - 9 V, SEC3 - 0 - 20 V / 50 mAmp, Class H, CRGO
Capacitor, Leaded, Aluminum Electrolytic, Radial, 100 uF, 50 Vdc, ±20%, -40 to +105°C, Pitch 5 mm, D 10 x 11 mm, Snap Fit, RoHS
Capacitor, Leaded, Aluminum Electrolytic, Radial, 10 uF, 50 Vdc, ±20%, -40 to +85°C, Pitch 2.00 mm, D 5 x 11 mm, Solderable, RoHS
Capacitor, Chip, Aluminum Electrolytic, Chip, 10 uF, 63 Vdc, ±20%, -40 to +85°C, Pitch 2.3 mm, D 8 x 6.2 mm, Solderable, RoHS
Capacitor, Chip, Aluminum Electrolytic, Chip, 47 uF, 35 Vdc, ±20%, -40 to +85°C, Pitch 2.3 mm, D 8 x 6.2 mm, Solderable, RoHS
Capacitor, Chip, Aluminum Electrolytic, Chip, 330 uF, 35 Vdc, ±20%, D 10 x 10 mm, RoHS
Hall Effect Sensor, 50 Amp, 0 to+/- 300 Amp, +/- 4 V, Open Loop, +/- 15 V, Panel Mounting , RoHS
Hall Effect Sensor, 100 Amp, 0 to+/- 300 Amp, +/- 4 V, Open Loop, +/- 15 V, Panel Mounting , RoHS
Hall Effect Sensor, 100 Amp, 0 to+/- 300 Amp, +/- 4 V, Open Loop, +/- 15 V, Panel Mounting
Transformer, Auto, Control, Copper, 1 Phase, PRI - 0 - 160 - 230 V / 1 Amp at 160 V, Class H, CRNGO
Transformer, Control, Isolation, Copper, PRI - 0-415 V, SEC - 0 - 180 - 230 V/ 400 mAmp for 1193DB, Class H, CRNGO
Capacitor, Leaded, Aluminum Electrolytic, Radial, 1000 uF, 50 Vdc, ±20%, -40 to +85°C, Pitch 7.5 mm, D 16 x 36 mm, Solderable, RoHS
Transformer, Control, Auto, Copper, 1 Phase, 0 - 230 - 415 V / 1 Amp at 230 V, Class H, CRNGO, 415 VA With PCA Mounted
Switch, Thermal, 10 Amp, Normally Open Automatic Reset, 250 Vac
Circuit Breaker Accessories, Auxiliary Switch, MCCB NKF100/150R/160R/100D
Circuit Breaker, Moulded Case, 60 Amp, DC, 380 / 415 Vac, 3 Pole, 10 kA, Panel Mounting
Circuit Breaker, Moulded Case, 32 Amp, AC, 415 Vac, 3 Pole, 10 kA, Panel Mounting, 90 83 153 mm
Circuit Breaker Accessories, Auxiliary contact Switch, 1 NO / NC, AC, Easypact NKS100R
Switch, Panel Mount, Load Break, 63 Amp, 4 Pole, On / Off, 415 Vac with Aux contact, 1 Normal Open, 1 Normal Close
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .