Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹41.8 LAccepted-AOC | 1 | Accepted-AOC Being the lowest bidder | |
| 2 | 2₹41.9 L+₹7,888.50 (0.19%)Rejected-AOC | 2 | Rejected-AOC Being other than the lowest bidder | |
| 3 | 3₹42.0 L+₹24,533 (0.59%)Rejected-AOC 60 MADHUVAN BANK COLONY ALWAR | 3 | Rejected-AOC Being other than the lowest bidder |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
11 Nov 2019, 6:00 pmClosed
CWE Kota
Headquarters Commander Works Engineer Military Engineer Services Dadwara, Military Station Kota (Raj)-324002
SPECIAL REPAIR TO BLDGS, TOILET BLOCKS AND COOK HOUSE AT ITARANA AND JP LINES ALWAR
2019_MES_285808_2
81535/ALW/05/E8
Open Tender
Civil Works
Item Rate
180 days
Alwar
For Enlisted contractors Class D cat a (i) and for unenlisted contractors meeting enlistment criteria for required class and category
8 documents required · 8 mandatory
₹500
GE Alwar
₹87,000
Yes
6 Jan 2020
19 Oct 2019
13 Nov 2019
19 Oct 2019
11 Nov 2019
31 Oct 2019
19 Oct 2019 - 29 Oct 2019
Amount
B/R ITEMS Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars & precast concrete mosonry etc. and removal all rubbish material complete all as specified directed.
Demolition of cement concrete (reinforced) as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Dismantling of sand stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar, complete all as directed
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as specified and directed.
Demolition of mud in roof, any thickness, including plastering, existing treatment and cleaning (Whether full thickness removed or only or part there off) etc. in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 km but not exc 1.5 km complete all as specified and directed.
Taking down cement or cement lime plaster any description, on brick or stone walls, etc. including racking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the primises, complete all as specified and directed.
Taking down carefully existing bitumen tarfelt, including plaster of any description over the surfaces of roof terraces including flashings and junctions of parapets/ Curb walls etc and removing of the rubbish to a distance exc. 500m but n exc. 1.00 km and depositing where directed, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as directed.
Taking down shutters of any description exc. 1.00 sqm & n exc. 2.00 sqm each and removing from site complete all as specified and directed.
Dismantling of frames with shutters of any description and any size window/ ventilator including iron grill grating complete all as specified and directed.
Demolition and breaking up drain pipes 150mm bore (Salt glazed ware, AC or reinforced concrete) fixed on wall set in cement mortar including PCC bed to drain pipe, packing under & haunching against the sides of drain pipes complete all as specified and directed.
Taking up or down steel tubing and connections alongwith bib tap, stop cocks and other fittings including cleaning for refixing or removal complete all as specified and directed :-
15mm bore.
20mm bore.
25mm bore.
32mm bore.
50mm bore.
Dismantling of PVC (SWR) drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed.
75mm bore.
110mm bore.
Dismantling of 75mm/110mm dia AC Pipe/ PVC pipes, complete all as specified and directed.
Dismantling water tank of capacity exceeding 250 Ltrs but not exceeding 500 Ltrs and removal from site to stores complete all as specified and directed .
Dismantling water tank of capacity exceeding 500 Ltrs but not exceeding 1000 Ltrs and removal from site to stores complete all as specified and directed .
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
M & L for walling of random rubble uncoursed well bonded, bedded & solidly hearted stone masonry built in cement mortar 1:6 complete all as specified and directed.
M & L for walling of random rubble uncoursed well bonded, bedded & solidly hearted stone masonry built in cement mortar 1:6 (Except stone) complete all as specified and directed.
Supply only liquid water proofing Admixture ISI mark complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundations, shafts, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc as well as n exc 10 sqmm on plan area and getting out, in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil omplete all as specified and directed.
Removal of excavated surplus spoil/ material to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point,complete, all as specified & directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M & L for brick work with sub class- B bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4), complete, all as specified & directed.
M & L for brick work with sub class- B bricks, sub class 'B' bricks straight or curved on plan exc 6 metre mean radius built in cement mortar (1:6), complete, all as specified & directed.
M & L for cutting holes into stone walls built in cement mortar or in cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 exc. half brick but not exc.one brick complete all as directed.
M & L for form work to soffits of suspended slabs for fair finished concrete surfaces and similar work not exc. 200 mm thick (Horizontal or sloping) complete all as specified and directed.
M & L for form work to sides for slabs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but n. exc. 20cm wide for fair finished concrete surfaces complete all as specified and directed.
S & F 50mm thick sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc n exc. 2 m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 and including dismantling of old stone slab complete all as specified and directed.
S&F 18/19mm thick exterior grade, prelaminated particle board (Prelaminated on one side) with decorative chorce lamination and other side balancing white lamination, fixed with screws to timber frame work/shutters, complete all as specified and directed.
S & F 35mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc . The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. (Note :- S & F Glass/gauge shall be measured and paid for separately)
S & F 35mm thick factory made IInd Class Hard wood (Hollock) plain framed, panelled door shutters two panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S & F Factory made solid PVC moulded door shutter, 28 to 30 mm thick (style), with 2, 4 or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face, supplying and fixing in frame at site as all as per specifications and drawings as applicable to item 08101 given in SSR Part – II.complete all as specified and directed
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part – II.
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as applicable to item 08095 given in SSR Part – II (2010) complete all as specified and directed.
S & F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m powder coated of any colour as approved ( thicknessof powder coating not less than 50 miron) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) anodized aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed.
S & F Factory made steel windows box type of any size double shutter, one openable shutter with glazing bars and other openable shutter without glazin bars fabricated with members of standard size as shown on CEJZ TD drawing No TD/2013/01 sheet 1/3 to 3/3 dated 30.03.13 complete all as specified and directed.
S & F for aluminium powder coated (minimum thickness of powder coating not less than 50 micron) as in ventilators half fixed and half louvers type and small window single leaf cut to size, jointed together with cadmium plated steel screws including rubber packing, aluminium beading or gasket for aluminium sections for fixing glass sheet and necessary fittings complete, screws plugs, handle, tower bolt, stay hocks etc. complete all as specified and directed. Make :- JINDAL/HINDALCO Note:- (a) Weight of aluminium sections shall only be measured. (b) The supply only rate of glass sheet & wire mesh will be measured seperately.
M & L drilling holes for pipes as in cooking platform, stone slab including RCC slab n. exc. 25mm dia and exc. 100mm depth, complete all as specified and directed.
S & F 75 mm size butt hinges, cold rolled mild steel, medium weight and fixed complete all as specified and directed.
S & F 100 mm size butt hinges, cold rolled mild steel, medium weight and fixed complete all as specified and directed.
S & F 100 mm size butt hinges, medium weight, stainless steel & ISI marked complete all as specified and directed.
S&F in repairs 15 mm bore pillar taps, cast copper alloy chromium plated with capstan head screwed down high pressure, with or without lettered HOT or COLD with long screwed shanks and fly nuts, screwed fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F 300 mm long aluminium alloy anodised, sliding door bolts with hasp, staple (Bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium allot and fixed complete all as specified and directed.
S&F 250 mm long aluminium alloy anodised, sliding door bolts with hasp, staple (Bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium allot and fixed complete all as specified and directed.
M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregate in as in precast concrete block as in bond stone etc. set in cement mortar 1:6 with joints matching complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate in bedding to drain pipes 150mm internal dia, including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and directed.
M&L for cutting into existing manholes/ septic tank for connecting new drains, making good to 150mm bore pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, smooth finished, and reforming benching as required complete all as specified and directed.
M & L for 150mm salt glazed stone ware drain pipes internal laid in trenches & jointed, complete all as specified and directed.
Construction of brick construction septic tank for 50 users of size 5000x2000x1300mm, brick work with sub class- B bricks, complete all as specified and as shown on drawing No CEJZ/2002/TD/S2, sheet 1/1
Construction of Soakage Well excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8m dia x 3.0m effective depth, complete all as specified and as shown on drawing No CEJZ/2004/TD/S-25, sheet 1/1
S & F 200mm long aluminium anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed.
S & F 150mm long aluminium anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed.
S & F 125mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
S & F 150mm long Aluminium handles, cast type, anodised, complete all as specified and directed.
S & F mild steel 300mm, ordinary rat tail rod pattern spring including roller and roller plate welded to mild steel frame complete all as specified and directed.
S & F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples, complete all as specified and directed.
S & F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples, as in repair, complete all as specified and directed.
Supply only stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples, complete all as specified and directed.
S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples, complete all as specified and directed
Supply only 4mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all specified and as directed.
Supply only 4mm thick sheet glass frosted and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all specified and as directed.
S & F in repairs chromium plated brass tubular towel rail 20 mm dia, D type 60 cm long between flanges complete all as directed.
S&F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F for angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S & F for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as directed.
M & L for TMT bars 6 to 8 mm dia, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
M & L for pressed steel shutter 1mm thick including pressed steel frame of 1.25mm thick sheet, 12mm dia MS rod for locking, two Nos chromium plated handle and one Godrej pattern lock 65mm 4 levers including two coat of spray painting over a shop coat of primer fixed to brick wall/concrete with 6 Nos 12 mm dia bolt 150mm long complete all as directed.
S & F stainless steel drapery rod of 25 mm inner dia (in lengths as directed) of approved colour with and including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug and steel screws on walls/beam, including PVC curtain rings of matching colour @ 10 cm C/C complete all as directed.
M & L for RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in slabs supported on walls and columns in floors, landings, shelves and the like complete all as specified and directed.
M&L for PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in roof padding, laid to a minimum consolidated thickness of 25mm as levelling course laid and compacted in min slope 1:30 over roof complete all as specified and directed.
M&L for PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
M & L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in drain covers set in CM 1:6 complete all as specified and directed.
M & L for 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of roof/floor/pavings/ path etc. complete all as specified and directed.
S&F powder coated( minimum thickness of powder coating 50 micron) anodised aluminium grill of approved pattern for window/ventilators/door complete all as directed.
M & L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as under floor tiles finished the surface even and fair complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation concrete complete all as specified and directed.
M & L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M & L for 50mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
M & L for rubbing and polishing to existing Kota Stone flooring including skirting/ riser to achieve mirror finishes, complete all as specified and directed.
M & L for machine cut Kota stone slab 18 to 20 thick size not less than 22"x22" as in floor, etc laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 20mm thick screed bed or bedding layer of in CM 1:6 and treating the surfaces with Bee-Wax finish complete all as specified and directed.
M&L 18 to 20 mm thick machine cut Kota stone slab as in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M & L for one coat of cement base paint on old decorated surface of walls including preparation complete all as specified and directed.
M&L 16 to 18mm thick granite slab/tiles (of any type table rubbed and polished) in steps, jambs pillars, window cills, cooking platforms and like set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and includin screed bed or bedding layer 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M & L rounding the edges of stone slabs on edge, such as in steps, cooking platform and other similar situations, complete all as specified and directed.
M & L for machine pressed precast concrete interlocking paver block of any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment laid over and including 25mm thick compacted sand cushioning layer etc complete and filling of joints with screed sand and vibrated with mechanical complete all as specified and directed.
M&L for precast (factory casted) cement Concrete kerb stone casted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with plain or interlocking joints (as directed), making groove in ground of desired dimension, placing in erect position Kerb stone in edging and set and jointed in cement mortar 1:4, making good distrubed surface of ground complete all as specified and directed.
M & L 5mm thick rendering on concrete surface of ceiling (Sunshed, Chajja etc.) in CM 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M & L for 10mm thick rendering in CM 1:6 on fair faces of brick work or stone masonry surfaces of walls, finished even and fair, without using extra cement complete all as specified and directed.
M & L for 15mm thick rendering in CM 1:4 on fair faces of stone masonry or concrete surfaces of walls, finished even and smooth, complete all as specified and directed.
M & L for 15mm thick rendering in CM 1:6 on fair faces of brick work of walls, finished even and fair, complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:4 on on fair face of brick surfaces or concrete surfaces finished even and smooth without using extra cement including mixing of liquid water proofing Admixture 0.5% of cement or as per manufacturer instructions complete all as directed. Note :- liquid water proofing Admixture to be measured & paid for seperately.
M&L rendering 5mm thick in CM 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and directed.
Extra over rendering or plastering for work in isolated widths or in width not forming part of general plastering such as in bands, sunk panel, cornices, skirting, drip moulds and similar work exc. 15cm but n.exc. 30cm in width or girth, including cutting to edges, all mitres and stopping ends etc. complete all as specified and directed.
M & L extra for forming fair finised drain or channel 30cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped and etc. complete all as specified and directed.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, on roof slab with liquid water proofing Admixture 0.5% of cement or as per manufacturer instructions in order to maintain proper slope over existing roof surfaces/ sunken floor for laying APP based polymbrane, finished completed all as specified and directed. (Note :- Supply only WPA shall be measured and paid separately)
M&L 300x450x7 mm / 375x250x7 mm thick glazed ceramic coloured tiles as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in white or coloured coloured cement to match the shade of tiles over and including 10mm thick cement plaster in CM 1:4 on surfaces of walls complete all as specifed and directed.
M&L 7-8 mm thick glazed ceramic coloured tiles ( Square/Rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in vertical surfaces such as skirting or dado etc. set and jointed in neat cement slurry & pointed in cement with admixture to match the shade of tiles over and including 10mm thick cement plaster in CM 1:4 on suraces of walls complete all as specified and directed.
M&L 300x200x7 mm thick glazed ceramic coloured tiles as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in white or coloured coloured cement to match the shade of tiles over and including 10mm thick cement plaster in CM 1:4 on surfaces of walls complete all as specifed and directed.
M&L 7-8 mm thick glazed ceramic coloured tiles ( Square/Rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floor set and jointed in neat cement slurry & pointed in cement with admixture to match the shade of tiles over and including 15 mm thick,screed bed or bedding layer of cement mortar 1:4, complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors and including 15mm thick screed bed in CM 1:6 laid on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
Preparation of old or previously treated steel surfaces and iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chromic primer complete all as specified and directed.
M & L for preparation of newly wooden surfaces or old untreated wooden or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved shade over one coat of pink primer complete all as specified and directed.
M&L for preparation of old or previously treated wooden or wood based surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved shade complete all as specified and directed.
M & L for preparing newly plastered walls surfaces and applying two coats of cement base paint of approved shade/ tint complete all as specified and directed.
M & L for complete removal of existing treatment on walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over 1mm thick wall care putty of approved make to achieve smooth finish complete all as specified and directed.
M & L for complete removal of existing treatment on walls including cleaning of any mortar drops, smoke soot, moulds, moss, fungus efflorescent salts, trading oil grees sports etc and preparation of old plaster surfaces of walls and applying two coats of cement based paint white or tined on walls complete all as specified and directed.
M & L for preparing newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M & L for preparing old plastered surfaces of Ceiling and applying two coats of white wash on ceiling complete all as specified and directed.
M & L for preparing old plastered surfaces of Ceiling and applying one coat of white wash on ceiling complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) over and including coat of 1mm thick wall care putty complete all as specified and directed.
M & L for preparation of decoarted surfaces of wall and applying two coats of oil emulsion distemper (OBD) complete all as specified and directed.
M & L for preparing old plastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
M & L for preparing old plastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
S&F GI tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed for following sizes:-
15mm bore.
20mm bore.
25mm bore.
40mm bore.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floor etc ) complete all as specified and directed for following bore:- Note : Old serviceable water tubing retrieved from taking down here-in-before shall be used. The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
15mm bore.
20mm bore.
32mm bore.
50mm bore.
S & F in repairs 15mm bore stop/angle valve cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs 15mm bore angle valve, two way, chromium plated screwed plated screwed down, high pressure with capstan heads screwed both ends for iron pipe or for union complete all as specified and directed.
S & F 15mm bore bib tap, fancy type, long body, half run with wall flange, cast copper alloy with capstan heads, chromium plated, screwed for iron pipe or for brass ferrule, as in repair complete all as specified and directed.
S&F in repairs corner shelf, complete all as specified and directed. Make 'Parryware' Cat Part No. T6010A1 or equivalent of Jaquar/Marc/Somany/ Prayag/Commander
S & F in repair swivel shower (fancy type) chromium plated with 125mm size with or without swivel joints, any size including fixing to steel pipe or union, complete all as specified and directed.
S & F 20 mm bore dia stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified & directed.
S & F 500 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), triple layers hoisted and fixed in position complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F 1000 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), triple layers hoisted and fixed in position complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F in repairs 15mm dia, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S & F in repairs 25mm dia, ball brass valves, high pressure, PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in position (Minimum wt 455 gms) complete all as specified and directed. Make :- PRAYAG or equivalent as specified in Appendix 'D'.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed for following sizes:-
75mm bore.
110mm bore.
S & F PVC (SWR) pipes single socketed in any length fixed to walls with holder bat clamps of GI flat iron 25x3mm complete all as specified and directed for following sizes:-
75mm bore.
110mm bore.
S & F PVC (SWR) branch piece, single (single Y) equal or unequal with oval access door complete all as specified and directed of following sizes:-
110mm bore.
S & F PVC(SWR) bend of any radius complete all as specified for following sizes:-
75mm bore.
110mm bore.
S & F PVC (SWR) junction single, (single T) equal or unequal with oval access door complete all as specified and directed of following sizes:-
75mm bore.
110mm bore.
S & F PVC (SWR) vent cowl for 75 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) reducers for 110mm dia of pipe, complete all as specified and directed.
S & F PVC (SWR) vent cowl for 110 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) WC connector bent type type complete all as specified and directed.
S & F PVC (SWR) floor trap 75mm dia outlet plain with grating including jointing with solvent cement complete all as specified & directed.
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S & F 100mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S & F in repair grating doom 100 mm dia of PTMT (minimum weight 40 gms), complete all as specified and directed. Make :- PRAYAG or equivalent as specified in Appendix 'D'.
M&L for gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm dia complete all as specified and directed.
S & F in repairs kitchen sinks without drainage board made of stainless steel 1mm thick kitchen with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cast iron cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including flush pipe of polythylene of low or high density or PVC 32mm bore with long screwed shanks anf fly nuts, complete all as specified and directed.
S & F 32mm dia high density polyethylene (HDPE) pipes pressure rating 6Kg/ Sq cm laid floor or fixed to walls including taking down old pipes complete all as specified and directed.
S & F 40mm dia high density polyethylene (HDPE) pipes pressure rating 6Kg/ Sq cm laid floor or fixed to walls including taking down old pipes complete all as specified and directed.
S & F in repairs vitreous china wash basin white flat back, size 550x400 mm, including brackets cutting for pinning in ends of brackets or erectin stand including waste fitting, 32mm size waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixed complete
S & F in repairs vitreous China squatting pan (Orissa pattern) water closet (white) of size 580 mm x 440 mm with integral foot rests, 'P' or 'S' trap, including connection to trap, flushing pipe and antisyphonage pipe etc and including provision of PCC (1:5:10) type E-2 lean concrete in filling, making good to floor (excluding flushing cistern and flush pipe etc) complete all as specified and directed.
S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed.
S & F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S & F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S & F second class hardwood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue, pinned at joints complete all as specified and directed.
S & F in repairs stainless steel kitchen plate rack of size 36 inch x 31 inch x 10 inch deep fabricated out of Ist quality 1.00mm thick stainless steel sheet with partition for small/large plates made out of 24 gauge thick stainless steel sheet all as per sample kept in GE office and hanged on wall by the help of steel screws grouted in walls with rawl plug complete all as specified and directed.
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydro Stop manufactured by TIKITAR DANOSA (INDIA) Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete all as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen. (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
E/M PORTION Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including teak wood battens or from existing conduits with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets light fittings (except tube light fitting) etc but excluding ceiling fan and removal of old material from site (except fittings to be reused) and making good disturbed surfaces of walls, floors ceiling etc complete all as specified and directed to match with existing surfaces.
M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and caping double locked box type with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash thru fasteners with cadmium plated screws all as per IS with MS concealed terminal boxes (Heavy duty) with 3mm thick plastic laminated bakelite (Hylam) sheet top cover for mounting switches, sockets, regulators, bell push etc, including 1.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly for the following :-
One light point controlled by one, one way switch.
One fan point controlled by one switch and regulator.
One bell/buzzer point controlled by one bell push.
One light point controlled by two, two way switch.
One 3 pin, 5/6 Amps socket outlet controlled by one 5/6 Amp switch on same board.
One 3 pin, 5/6 Amps socket outlet controlled by one 5/6 Amp switch on independant board.
All as per serial item No 170 but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independant board with 2.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping double locked box type with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash thru fasteners with cadmium plated screws all as per ISS with MS concealed terminal boxes (Heavy duty) with 3mm thick plastic laminated bakelite (Hylam) sheet top cover for mounting switches, sockets, including 2.5 Sq.mm multistranded copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly.
S & F switch piano flush type 5/6 Amps, single pole, one way, 230 Volts complete all as specified and directed.
S & F switch piano flush type 5 Amps, single pole, two way 230 Volts complete all as specified and directed.
S & F switch piano, flush type single pole, one way 15 Amp, 230 Volts complete all as specified & directed.
S & F socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts complete all as specified & directed.
S & F socket outlet two-in-one, 3 pin, 5 Amp and 15 Amp, flush type, 240 Volts complete all as specified & directed.
S & F bell push, flush type, 5 Amp, 230 volts complete all as specified & directed.
S & F bell/buzzer, AC, 230 Volts, single pole complete all as specified & directed.
S & F ceiling rose, surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed.
Taking out existing tube light fitting & refixing only fluorescent tube light fitting/ LED fittings on wall/ ceiling at same location including S&F wooden round block etc. and including white coloured round three core, PVC insulation, sheathed copper cable of required size and length from ceiling rose to fitting complete with all standard fitting, complete all as specified and directed.
S&F in repair decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 18W with LED tube of model E-LITE LED pride and connecting up with the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. Make : Cat Part No LHEXBHP71N1W018 of make Havells or equivalent model of make as specified in Appendix 'D'.
S & F lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F for mounting bracket made out of GI tubing 25 mm bore light grade 1.5m long made to shape including 2 Nos flat iron clamp 25x5xmm to be tightened on two Nos rag bolts of size 12mm dia and 100 mm long grouted fixed on PCC/sted pole with bolts and washers including dismantling and taking down old U/S street light bracket complete all as specified and directed.
Taking down old unserviceable CFL lamp and Supply and fix ADORE LED lamp of 9/10 Watt complete all as specified and directed. Model/Make : Model ADORE 10W E27 CDL Ball lamp Cat Part No. LHLDERHEML8X010 of make Havells or equivalent model of make as specified in Appendix 'D'.
S & F electronic fan regulator, socket type, 0-4 step of cap, 100W, and connecting up, 200-250 Volts AC ISI marked, complete all as specified and directed.
S & F exhaust fan complete of 300mm sweep, 240 Volts AC including provision of hole in wall of suitable size for fixing of exhaust fan, complete all as specified and directed.
S & F sheet metal enclosure double door DB SPN 8 way, 230 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal enclosure single door type SPN 2 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F MCB SPN 32 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I, complete, all as specified & directed.
S & F MCB SP 6 to 32 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 06 Sqmm copper multistranded conductor drawn through and including PVC conduit 25mm bore fixed on surface to wall/ ceiling by means of MS screws and saddles including one run of 6 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only.
Supply and fixing LED street light fitting 20 Watt 230 V, 50 Hz DRACO Series , lightand connecting the fitting from using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. Make & Model :- Cat Part No LTESS20WLED of make C & S or equivalent model of make as specified in Appendix 'D'.
Supply and fixing LED street light fitting 20 Watt 230 V, 50 Hz with case aluminium housing toughened glass diffuser, IP-65/66 and including all necessary fitting accessories and LED complete all as specified and directed. Make & Model :- Cat Part No SZPSLMM020 of make Shakti or equivalent model of make as specified in Appendix 'D'.
S & F second class hardwood rectangular block open recessed of size 30cm x 25cm x 5 cm depth with 3 mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos) complete all as specified and directed.
S & F 4 sqmm PVC cable, weather proof, flat twin core, fixed on wall with PVC conduit 25mm size including dismentling and takong down existing unservceaible PVC cable, complete all as specified and directed.
Supply and Laying/ fixing, jointing, testing and commissioning of 2 core 16 Sqmm LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts, through pipe, under floors or roads/ pipes/fixed on walls/poles including taking down old unserviceable cable complete all as specified and directed. Note :- (i) Sand cushioning, cable protection, GI pipe for protection and excavation & earth work shall be measured & paid for separately. (ii) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection, complete, all as specified & directed.
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
S & F 40 mm bore Galvanised steel tubing light grade for protection of under ground cable on poles / walls/under road crossing/laid in trenches etc conforming to IS-1239complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6.3 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
shiva construction
M/S JINDAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .