| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
₹38.2 L
EMD Value
₹50,000
Closing Date
25 Oct 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Managing Director
KPHCC Head Office, Palayam
Police Dept-State Annual Plan Scheme 2024-25- Setting up of work space for CCTNS Division at the Traffic building at Nandavanam,Palayam, Thiruvananthapuram (DSR 2018)
2024_KPHCC_695312_1
NIT NO. 110/KPHCC/2024-25
Open Tender
Civil Works - Buildings
Item Rate
60 days
Nandavanam
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
23 Nov 2024
17 Oct 2024
26 Oct 2024
17 Oct 2024
25 Oct 2024
17 Oct 2024
Amount
FLOORING
11.49.2 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tiles 600x600 mm
11.48.2 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
OD34955/2023-2024 Providing and laying Vitrified step tiles in single piece indifferent sizes (thickness to be specified by manufacturer),using High polymer modified quickset tile adhesive with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, including grouting the joint with white cement & matching pigments etc. complete
FALSE CEILING-12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1
Glass Door , Partition and Horizontal blinds
OD34908/2023-2024 Toughened Glass Door : Providing and fixing Single door (110 x210 cm) of 12mm thick Toughened glass door (Saint Gobain or Equivalent) with (dormakaba or Equivalent) patch fittings (Floor Spring, Top patch, pivot Pin, Bottom patch, Corner lock, Handle- Dorma TGDIH 25 x 350 mm Stainless Steel 304 H-Type Glass Door Handle - Satin Finish ). Including all cost and conveyance of materials, labour etc. complete.
OD34909/2023-2024 Providing and fixing 12mm thick Toughened glass(Saint Gobain) Partition System with powder Coated aluminium Sections(Fish mouth channel /40 mm wide)Clip sytem as per drawing /instruction of Engineer in charge .Including all cost and conveyance of materials, labour etc complete.
OD34910/2023-2024 Supplying and Fixing Etching sticker for glasses in doors and fixed partition including all cost and labour charges etc complete.
21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.2.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
OD34958/2023-2024 Providing and fixing manual Controlled Zebra Curtains/Blinds made of premium quality fabric around aluminium tube to be raised and lowered by ball chain pulley, to provide adequate privacy and light control (Make : SERA ZG/equivalent, model: EASTHER MAGIC SHADE - EM –6/2 - SAND). as per architect approved shade .Including cost and conveyance of all materials labour charges etc.
Work Station
OD34680/2023-2024 Supplying and providing single seat work station 110 x 60 x 75 cm using 16 mm (or nearest ) thick treated rub wood well planed finished with suitable grains and polished in mechanized plants wood panels for top. The verticals, horizontals and two facing sides are using 15mm panels. providing 1 Nos of drawers and one number key board using 15mm panels. hinges, (ebco or equivalent) best quality alloy sliders, S S handles, locks and keys, one number of cabinet with shutter, one number of open CPU cabinet etc complete, (sub: minor variations in site condition) design or direction of engineer in charge.
OD34713/2023-2024 Supplying and placing Chair (make Minister ,Model :shell Task/Equivalent) as per design intent .including all cost and conveyance of materials labour etc complete
Sheet roofing
OD34959/2023-2024 Roofing with Pre Laminated Shingles of overall 6mm thick fixed with adhesive on 12mm thick V board. V Board 10mm thick cement based board above the already fabricated and erected rafters and purlins using MS rectangular/Square tubular sections of suitable sizes as per approved design and drawing including cost and conveyance of all materials hire and labour charges, Cost of scaffolding etc., complete.
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Finishing works
13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
13.7.1 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
Electrification
1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.9 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.14.10 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mmd.
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.43 Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
1.55.1 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
1.55.2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43).
90.3.12 Conveyance and fixing charges of recess mounting down light fittings of all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required.
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.10.1.3 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.5 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
OD34226/2023-2024 Supply and providing 9W recess mounted ceiling light of department approved make as instructed by engineer in charge.
OD34227/2023-2024 Supply and Providing 6W LED Strip, giving connection etc complete as required.
OD34228/2023-2024 Supply and providing 3Amps Led driver for the 6W LED Strip.
OD34229/2023-2024 Supply and providing 18W recess mounted ceiling light of department approved make as instructed by engineer in charge.
OD34230/2023-2024 Supply and providing 15W LED panel light having CRI &80 , colour temperature -4000K with IP 20 rating of approved make as instructed by department engineer in charge.
OD34231/2023-2024 Supply and providing 20W LED Tube of approved make with lumens efficiency of 100 lumens /watt, THD<=20, CRI>80,Colour temperature of 3000K with inbuilt surge protection(2.5KV).
Networking
OD34233/2023-2024 Supply and providing Cat 6 Input/Output Modular socket with plate on surface
OD34240/2023-2024 Supply,crimping RJ45 connectors /sockets and fixing to the existing enclosure and giving connection etc complete.
OD34234/2023-2024 Supply and providing 2 Mtr Patch Cord
OD34235/2023-2024 Supply and providing 1Mtr Patch Cord.
OD34860/2023-2024 Supply and installation of Layer 2 managable PoE switch with Non blocking switch fabric having 24 Port 10/100/1000Mbps PoE & 4x1G SFP port. Three year warranty.
OD34861/2023-2024 Supply,installation,testing and commissioning of 24 Port Gigabit Switch(10/100/1000 mbps) of govt approved make, giving connection etc. complete as required
OD34858/2023-2024 Supply ,providing and fixing of 6U cabinet of approved make powder coated with glass panel front door including PDU, cable management system and giving connection etc complete as required.
OD34859/2023-2024 Supply and installation of Cat6 UTP , Patch Panel - 24 ports fully loaded patch panel with rear strain release bar.
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
Air Conditioners
OD34241/2023-2024 Supply,installation,testing and commissioning of 2 Ton Spilt Type Air Conditioner with 5 KVA stabilizer of department approved make as instructed by engineer in charge, giving connection etc. complete as required.
OD34241/2023-2024 Supply,installation,testing and commissioning of 2 Ton Spilt Type Air Conditioner with 5 KVA stabilizer of department approved make as instructed by engineer in charge, giving connection etc. complete as required.
OD34246/2023-2024 Outdoor support for air conditioners
OD34247/2023-2024 Extra Copper pipping for the spilt type air conditioners
OD34242/2023-2024 Supply and Installation and onsite warranty of BIS Certified 5KVA/120 VDC True Online IGBT Basedmicroprocessor controlled double conversion technology Online UPS with Inbuilt Isolation Transformer, with static bypass with zero break time, Communication Interface and with 10 Nos. of 12V/40AH Tubular Batteries with Battery Rack and accessories. Mandatory CERTIFICATION FOR UPS - ISO9001-2015,ISO14001 -2015, ISO 45001:2018(OHSAS), CE Certification AND BIS Certification, RoHS Compliant,IEC 62040 – 1, 2 & 3. OEM Should have production unit and minimum 6 registered service centers in Kerala.
R PADMAKUMAR
Bidder Name
MOHAN KUMAR C P
R PADMAKUMAR
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1083826.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .