| 1 | L1₹14.7 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹14.8 L+₹18,080 (1.23%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹14.9 L+₹20,394 (1.39%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹18.1 L+₹3.4 L (23.5%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L4 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | SURESH ELECTRICALS L1 | Rameshwar Enterprise L2 | MONA GENERATOR SEVICES PVT. LTD. L4 | OM ELECTRICAL ENERGY L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of factory assembled diesel Engine driven generating set minimum capacity of 100 KVA duly certified by agencies / lab designated by MoEF/CPCB-IV with latest norms for 3 phase, 4 wire, 415 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosures having salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application/installation. Integrated design thereby facilating/easy handling installation and shifting of the eqpt at site. The design of integrated acoustic enclosure should be of type approved by National physical laboratory as per central pollution control board (CPCB-IV) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2;4) type B-1 foundation for acoustic enclosures foundation as recommended by manufacturer, vibration pad and sand cushioning around PCC foundation etc, all and tools and spares as provided by manufacturer complete incl all as specified and as directed with the following specifications :-
Note: DG set capacity shall be minimum 100 KVA or next higher size capacity as manufactured by OEM without any extra cost. | 1 | Each Job | 14,21,000 ₹14,21,000 Lowest | 14,30,000 ₹14,30,000 | 17,36,845 ₹17,36,845 | 14,38,350 ₹14,38,350 |
| 1.01(A) ENGINE : Water cooled with radiator diesel Engine confirming to IS : 10001/10002 of 1500 RPM capacity to match the 100 KVA alternator under NTO conditions with provision of 10% overload for 1 hour in every 12 hours running conforming to IS 6514/ IS 10001 / 10002 the Engine shall consist of the following:- (i) Fly wheel (ii) Flexible coupling with guard bolts and nuts etc. (iii) Air cleaner heavy duty dry type (iv) Radiator with guard and water pump engine mounted. (v) Dynamo of suitable capcity. (vi) Air cleaner heavy duty dry. (vii) Fuel injuction pump. (viii) Radiator fan (Blower type) with guard. (ix) Electronic A1 class governer. (x) Fuel filter Mounted. | |||||||
| 1.02(xi) Lubricating oil filter mounted. (xii) 12/24 Volt self- regulating alternator belt driven by engine. (xiii) Exhaust silencer heavy duty residential type and retrofitting of emission control deivce as per NGT norms. (xiv) Corrosion resistor / scale inhibitor. (xv) Starter 12/24 V DC. (xvi) Lubricating oil cooler. (xvii) Lubricating oil pump (Gear type). (xviii) Turbo Charger. (xix) Exhaust piping shall be insulated with asbastos rope duly cladded with aluminium sheet. (xx) Instrument inbuilt control panel complete with the following:- (a) Auto /mannual starting switch with key. (b) Lubricating oil tempreture gauge. (c) Lubricating oil pressure gauge. (d) Water tempreture gauge. (e) Battery charging ammeter. (f) Battery charging indicating lamp. (g) Hour meter with RPM indicator. (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure. (k) Over speed stop with double driven adoptor. | |||||||
| 1.03(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364. (ii) Type :- Self excited self-regulated with automatic voltage regulator. (iii) Rating :- 100 KVA at 0.8 PF lagging 4 pole hozontal at NTP condition 3 (iv) Speed :- 1500 RPM (v) System :- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected. (vii) Enclosure :- Screen protected dip proof. (viii) Ventilation :- Self ventilated (ix) Insulation :- Insulation Class H | |||||||
| 1.04(C) AUTOMATIC CONTROL PANEL AMF panel outdoor type for automatic ON during power failure and OFF while power is on with adjustable time delay, panel totally enclosed fabricated out of CRCA sheet 3.2 mm SWG, Outdoor type over an angle iron frame made out of 50 x 50 x 6 mm angle with removable side cover hinged front panel and rear panel of easy accessibility complete with internal wiring of suitable size copper conductor cable and cable gland for external connection and comprising of following :- (i) Main incoming MCCB 4 pole 160Amp 415 volts 25 KA- 2Nos (ii) Panel mounted, flush type 96 x 96 mm size , Digital voltmeter with selector switch - 01 No (Recommended by Manufacturers) (iii) Panel mounted, flush type 96 x 96 mm size, Digital Ammeter (0-200) amps with selector switch with CT - 01 No (Recommended by Manufacturers) (iv) Frequency metre digital type - 01 No (v) MCB's (vi) LED type signal lamp for DG set/ commercial power ON/OFF indication - 06 Nos (vii) Copper bus bar of suitable size. (viii) Circuit diagramed plate (ix) CT operated KWH metre - 01 No (x) Power factor meter digital type - 01 No (xi) Reverse power relays, over current and short circuit protection relay with suitable CTs and suitable contactors, - 01 Set (xii) Mannual mode, Auto mode, Test mode - 01 set (xiii) Single phase preventer - 04 Nos (xiv) Battery charger (xv) All relays/power contactors of suitable size and capacity Note: Make of AMF panel should be OEM of the DG set only, the safety parameter of the DG set should be incorporated with AMF Panel. | |||||||
| 1.06(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 12 Hrs running at full load including necessary piping with the following: (i) Level indicator on fuel tank (ii) Drain plug (iii) MS class 'C' piping for inlet from pump to tank of engine (iv) Fuel strainer (v) Air vent. (b) BATTERY As recommended by manufacturers | |||||||
| 1.07(E) ACOUSTIC ENCLOSURE - Acoustic Enclosure suitable for 100 KVA DG set as under: (i) Fabricated out of CRCA sheet of suitable thickness not less than 1.6mm. Polyster based powder, coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The door are gasketed with EPDM gaskets. The construction should be such that it prevent entry of rain water splashing in to enclosure and allows free and quick flow of rain water to the ground in the event of heavy rain. (iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of density at 96 Kg/CUM covered with fiber glass cloth and perforated powder coats sheet specially design alternator (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. (iv) Adequate ventilation to meet air requirement not for combustion and heat removal with prove of a blower. (v) Emergency stop push button outside the container. (vI) Provision of light inside the Canopy providing of LED fitting 1x20 watt with wiring and control switch. (vii) The canopy should be provided with light enclosure temprature safty device. (F) BASE PLATE- Sturdy, fabricated welded contruction out of MS channels ISMC of suitable size suitable for fixing of DG set, required anti-vibration mounting pads shall be provided all specified by the manufacturer. Note: 1. Certifact for compliance of pollution under control as per CPCB-IV norms to be provided by the manufacturer is to be submited. 2. Test cerfitificate by the manufacturer is to be submited. 3. AMF Panel to be certified CPRI, contractor submit to same to the department. 4. DG set load testing to be carried by the competent authority including fuel, T & P, test load and arrangement for the same deemed to be included in above quoted rates. 5. DG set shall be assembeled with sound proof canopy) | |||||||
| 2.00 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm 3.5 core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
(Note :-(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.) | 22 | RM | 530 ₹11,660 Lowest | 670 ₹14,740 | 724 ₹15,928 | 532 ₹11,704 |
| 3.00 | M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed.
Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate. | 6 | Each set | 5,500 ₹33,000 Lowest | 6,500 ₹39,000 | 9,549 ₹57,294 | 6,000 ₹36,000 |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
26 Aug 2025, 6:00 pmClosed
CWE (AF) Jamnagar
CWE (AF) jamnagar Airforce stn No. 1
SPECIAL REPAIR / REPLACEMENT OF DG SET AT TECH AREA UNDER GE (AF) JAMNAGAR No 1
2025_MES_723143_1
81248/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jamnagar
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NO 1 JAMNAGAR
₹31,000
Yes
29 Sept 2025
29 Jul 2025
28 Aug 2025
29 Jul 2025
26 Aug 2025
12 Aug 2025
Amount
Supply, installation, testing and commissioning of factory assembled diesel Engine driven generating set minimum capacity of 100 KVA duly certified by agencies / lab designated by MoEF/CPCB-IV with latest norms for 3 phase, 4 wire, 415 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosures having salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application/installation. Integrated design thereby facilating/easy handling installation and shifting of the eqpt at site. The design of integrated acoustic enclosure should be of type approved by National physical laboratory as per central pollution control board (CPCB-IV) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2;4) type B-1 foundation for acoustic enclosures foundation as recommended by manufacturer, vibration pad and sand cushioning around PCC foundation etc, all and tools and spares as provided by manufacturer complete incl all as specified and as directed with the following specifications :- Note: DG set capacity shall be minimum 100 KVA or next higher size capacity as manufactured by OEM without any extra cost.
(A) ENGINE : Water cooled with radiator diesel Engine confirming to IS : 10001/10002 of 1500 RPM capacity to match the 100 KVA alternator under NTO conditions with provision of 10% overload for 1 hour in every 12 hours running conforming to IS 6514/ IS 10001 / 10002 the Engine shall consist of the following:- (i) Fly wheel (ii) Flexible coupling with guard bolts and nuts etc. (iii) Air cleaner heavy duty dry type (iv) Radiator with guard and water pump engine mounted. (v) Dynamo of suitable capcity. (vi) Air cleaner heavy duty dry. (vii) Fuel injuction pump. (viii) Radiator fan (Blower type) with guard. (ix) Electronic A1 class governer. (x) Fuel filter Mounted.
(xi) Lubricating oil filter mounted. (xii) 12/24 Volt self- regulating alternator belt driven by engine. (xiii) Exhaust silencer heavy duty residential type and retrofitting of emission control deivce as per NGT norms. (xiv) Corrosion resistor / scale inhibitor. (xv) Starter 12/24 V DC. (xvi) Lubricating oil cooler. (xvii) Lubricating oil pump (Gear type). (xviii) Turbo Charger. (xix) Exhaust piping shall be insulated with asbastos rope duly cladded with aluminium sheet. (xx) Instrument inbuilt control panel complete with the following:- (a) Auto /mannual starting switch with key. (b) Lubricating oil tempreture gauge. (c) Lubricating oil pressure gauge. (d) Water tempreture gauge. (e) Battery charging ammeter. (f) Battery charging indicating lamp. (g) Hour meter with RPM indicator. (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure. (k) Over speed stop with double driven adoptor.
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364. (ii) Type :- Self excited self-regulated with automatic voltage regulator. (iii) Rating :- 100 KVA at 0.8 PF lagging 4 pole hozontal at NTP condition 3 (iv) Speed :- 1500 RPM (v) System :- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected. (vii) Enclosure :- Screen protected dip proof. (viii) Ventilation :- Self ventilated (ix) Insulation :- Insulation Class H
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 12 Hrs running at full load including necessary piping with the following: (i) Level indicator on fuel tank (ii) Drain plug (iii) MS class 'C' piping for inlet from pump to tank of engine (iv) Fuel strainer (v) Air vent. (b) BATTERY As recommended by manufacturers
(E) ACOUSTIC ENCLOSURE - Acoustic Enclosure suitable for 100 KVA DG set as under: (i) Fabricated out of CRCA sheet of suitable thickness not less than 1.6mm. Polyster based powder, coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The door are gasketed with EPDM gaskets. The construction should be such that it prevent entry of rain water splashing in to enclosure and allows free and quick flow of rain water to the ground in the event of heavy rain. (iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of density at 96 Kg/CUM covered with fiber glass cloth and perforated powder coats sheet specially design alternator (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. (iv) Adequate ventilation to meet air requirement not for combustion and heat removal with prove of a blower. (v) Emergency stop push button outside the container. (vI) Provision of light inside the Canopy providing of LED fitting 1x20 watt with wiring and control switch. (vii) The canopy should be provided with light enclosure temprature safty device. (F) BASE PLATE- Sturdy, fabricated welded contruction out of MS channels ISMC of suitable size suitable for fixing of DG set, required anti-vibration mounting pads shall be provided all specified by the manufacturer. Note: 1. Certifact for compliance of pollution under control as per CPCB-IV norms to be provided by the manufacturer is to be submited. 2. Test cerfitificate by the manufacturer is to be submited. 3. AMF Panel to be certified CPRI, contractor submit to same to the department. 4. DG set load testing to be carried by the competent authority including fuel, T & P, test load and arrangement for the same deemed to be included in above quoted rates. 5. DG set shall be assembeled with sound proof canopy)
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm 3.5 core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. (Note :-(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.)
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
Rameshwar Enterprise (BID ID -3398408)
OM ELECTRICAL ENERGY (BID ID -3395606)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3398831)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .