The Executive Engineer (E)
The Executive Engineer (E), EMD South East, PWD, Thyagraj Sports Complex, New Delhi-110003
(SH- Provision of Package Type Air Conditioning Unit for Server Room and other related EI work).
2026_PWD_293957_1
49/EE(E)/EMD South East/PWD/2026-27 (Recall)
Open Tender
Miscellaneous Services
Works
30 days
At Site
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹13,794
29 Jun 2026
20 Jun 2026
27 Jun 2026
20 Jun 2026
27 Jun 2026
20 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, installation , testing and commissioning of Air cooled ductable type Packaged air-conditioning units complete with Hermetically sealed Scroll compressors fitted inside the indoor unit & first charge of refrigerant R410A or equilant permitted green refrigerant & oil ,air cooled condenser, fan section with statically/dynamically balanced centrifugal blower driven by a Totally Enclosed Fan Cooled (TEFC) squirrel cage three speed motor, Multi rows cooling coil of copper with aluminium fins etc. The enclosures shall be fabricated of M.S. The Package unit shall be equipped with synthetic fiber filter, insulated drain pan, controls all encased in a unit. The casing shall be factory powder coated. Electrical panel board for Package units shall comprise of control and power panel with including all associries i/c Voltage scanner, overload, low voltage, high voltage & phase imbalance protection, along with VI Pads complete with all ancillaries including MS painted stand for Outdoor units of suitable size, foundation and allied minor civil works as per instructions of Engineer-in-charge of following ratings including electric control panel & fitting as per CPWD specifications and as per IS: 8148 complete as required. | |||||
| 1.01 | 8.0 TR (2.8 EER) | 3 | Nos. | 1,77,609 | ₹5,32,827 |
| 2Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. | |||||
| 2.01 | 150 mm width X 50 mm depth X 1.6 mm thickness | 75 | Mtrs. | 803 | ₹60,225 |
| 3Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 3.01 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 50 | Mtrs. | 615 | ₹30,750 |
| 3.02 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm | 60 | Mtrs. | 1,157 | ₹69,420 |
| 4Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | |||||
| 4.01 | Upto 35 sq. mm (clamped with 1mm thick saddle) | 250 | Mtrs. | 64 | ₹16,000 |
| 5Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
tender.pdf
Tender Documents • 2.30 MB
BOQ_390786.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].