Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 29 NANDANVAN ROAD GARUDEO NAGAR NAGPUR NAGPUR MAHARASHTRA 440009 | 440009 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 3A 330 NEAR NAGARPUTRUKAN DELTA ROTO TECH PRIVATE LIMITED 3 152 1 NEAR NAGARPUTRUKAN SAIRAM NAGAR SANKARI MAIN ROAD NETHIMEDU SANKARI MAIN ROAD | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance DHARWARD KARNATAKA 580030 UDYAM KR 13 0012378 29AAPFD4631B1ZJ R M | DHARWAD | KARNATAKA | 580030 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 19 421 VRINDAVAN BUILDING OPP GOVT ITI HMT ROAD KALAMASSERY ERNAKULAM KERALA 683104 | ERNAKULAM | KERALA | 683104 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
7 Aug 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SM(PandP)UC
SM(PandP)UC PD Administrative building FACT,Udyogamandal
Overhauling,Oil filtration, and painting works of 5 MVA Transformers and leak arresting of TR. No.4, 15-20MVA in 110kV substation at FACT-UC 2023-24
2023_FACT_764347_1
3017/2023-2024/E27910
Open Tender
Miscellaneous Works
Item Rate
365 days
FACT, Udyogamandal
Please refer Tender documents.
3 documents required · 3 mandatory
₹50
Yes
FACT
₹12,000
Yes
8 Aug 2023
29 Jul 2023
8 Aug 2023
29 Jul 2023
7 Aug 2023
29 Jul 2023
Overhauling,Oil filtration, and painting works of 5 MVA Transformers and leak arresting of TR. No.4, 15/20MVA in 110kV substation at FACT-UC 2023-24
Overhauling of TELK make 11/3.3 kV, 5 MVA Power Transformer at FACT 110 kV substation of oil capacity-3420 liters and Complete body painting at site as per the scope of work specified and terms and conditions attached. Scope of work: A) Draining of oil, disconnection and disassembling of HV/LV bushings, conservator tank/ pipe lines, cooling fins, tap-changer, Inspection windows, Explosion vent Unit, main tank lid etc. B) Lifting the core/ coil assembly for inspection, cleaning, tightness check, testing of core/ coils and performing any repairs as required. C) Cleaning the tank inside complete to remove all sludge and impurities present. D) Servicing / re fixing of MOLG / Level gauge, temperature gauges, Buchholz relay, replacement of explosion vent diaphragm and wire guard etc. E) Flushing the interior of the body and windings with new oil to clean inside. F) Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows Buchholz relay, Air breather, pipe Lines, Main lid with new and approved type . G) Inspection/ replacement of drain valves, radiator valves, HV, LV & Neutral side Bushings as required. H) Rinsing of radiators and re assembling of the Transformer to its original shape. I) Vacuum oil filling of the Transformer and Hot oil circulation till satisfactory oil test results are achieved. J) Testing of oil as specified in special conditions. K) Supply of all required materials for cleaning the Transformer body and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint of approved colour and make. M) Pre-commissioning checks for energisation.
Overhauling of VOLTAMP make 11/3.3 kV, 5 MVA Power Transformer at FACT 110 kV substation of oil capacity-2220 liters and Complete body painting at site as per the scope of work specified and terms and conditions attached. Scope of work: A) Draining of oil, disconnection and disassembling of HV/LV bushings, conservator tank, radiators/cooling fins, pipe lines, tap-changer, Inspection windows, Explosion vent Unit, main tank lid etc. and lifting the transformer from site and leads to road for transporting to FACT’s workshop for overhauling and returned to site accordingly. B) Lifting the core/ coil assembly for inspection, cleaning, tightness check, testing of core/ coils and performing any repairs as required. C) Cleaning the tank inside complete to remove all sludge and impurities present. D) Servicing / re fixing of MOLG / Level gauge, temperature gauges, Buchholz relay, replacement of explosion vent diaphram and wire guard etc. E) Flushing the interior of the body and windings with new oil to clean inside. F) Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows Buchholz relay, Air breather, pipe Lines, Main lid with new and approved type . G) Inspection/ replacement of drain valves, radiator valves, HV, LV & Neutral side Bushings as required. H) Rinsing of radiators and re assembling of the Transformer to its original shape. I) Vacuum oil filling of the Transformer and Hot oil circulation till satisfactory oil test results are achieved. J) Testing of oil as specified in special conditions. K) Supply of all required materials for cleaning the Transformer body and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint of approved colour and make. L) Pre-commissioning checks for energisation. (Note: Overhauling of this transformer shall be done at FACT’s Workshop. Moving/transportation of transformer to workshop and retun it to original position are under the scope of vendor )
Oil leak arresting located in flanges of No.4 110kV/11kV TELK make, 15/20MVA Power Transformer at FACT 110 kV substation of oil capacity-17600 liters and Complete body painting at site as per the scope of work specified and terms and conditions attached. Scope of work: A) Draining of oil, disconnection and disassembling of HV/LV bushings, conservator tank, radiators/cooling fins, pipe lines, tap-changer, Inspection windows, Explosion vent Unit, main tank lid etc. B) Servicing / re fixing of OLTC, MOLG, Level gauge, temperature gauges, Buchholz relay, replacement of explosion vent diaphram and wire guard etc. C) Flushing the interior of the body and windings with new oil to clean inside. D). Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows Buchholz relay, Air breather, pipe Lines, Main lid with new and approved type . E) Re fixing of all dismantled parts of transformer back to it’s original position and tightening of all flange joints. F) Refilling of the drained oil after filtering and Hot oil circulation till satisfactory oil test results are achieved. G) Inspection/ replacement of drain valves, radiator valves, HV, LV & Neutral side Bushings as required. H) Testing of oil as specified in special conditions. I) Supply of all required materials for cleaning the Transformer body and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint of approved colour and make. J) Pre-commissioning checks for energisation. (Note: Crane facilities required for the work shall be provided by FACT at free of cost.)
Arpan Electricals and Enterprises
Delta Roto tech Pvt. Ltd.
DEVI POWER TECH
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .