Tender Value
₹10.6 L
EMD Value
₹21,500
Closing Date
5 Sept 2022, 4:00 pmClosed
Executive Engineer
Office of the Executive Engineer Electric Division Vijaypur
Shifting of HT Line from Center to Side along the under construction Park Near Anand Vihar leading towards fruit and Vegetable Mandi Ward No.11 Bari Brahamana on Turnkey Basis within the jurisdiction of Executive Engineer, JPDCL, Jammu
2022_PDD_185660_1
EDV/ 14 of 2022-2023 Dated 26-08-2022
Open Tender
Electrical Works
Turn-key
30 days
Samba District
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Executive Engineer Electric Division Vijaypur
₹21,500
26 Apr 2023
26 Aug 2022
6 Sept 2022
27 Aug 2022
5 Sept 2022
27 Aug 2022
27 Aug 2022 - 5 Sept 2022
Amount
SCOPE OF WORK FOR LAYING OF HT LINE ON 9 MTR PCC POLES USING ACSR DOG / RABBIT CONDUCTOR
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR Dog Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Supply, Laying & Stringing of ACSR Rabbit Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Supply Installation, Testing & Commissioningof 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Supply Installation, Testing & Commissioningof 11kV Polymeric composite Disc Insulator 12kV,min. failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium Jointing sleeves
Providing and fixing of P G Clamps
Supply,Laying of 120 mm² AB HT Cable (3x120+1x95mm²)
Providing & fixing of heat shrinkable outdoor cable termination kit
Providing& Erection Of Tension /Suspension clamp with eye hook along with Gavinized nuts & bolts.
Shifting of existing 63 KVA Sub Station
Dismentalling of 11/0.433 KV, 63 KVA 3-Phase Distribution Transformer .
Dsmentalling of 8/9 Mtr Long PCC Pole including back filling of soil & consolidating by ramming, watering etc.
Dismantelling of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated including all necessary Nut & Bolts & Washers etc.
Dismantelling of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
Dismantelling 11 KV Horn Gap Fuse Set 3 Phase 200A
Dismantelling of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Dismantelling of 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Dismantelling of Distribution Box for 63 kVA DTRwith MCCB for incomer & SFU's for OutgoingCircuits
Dismantelling of 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Dismantelling of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm
Dismantelling of Anti Climbing device with Clamps
Dismantelling of Danger Plates with Clamps
Dismantelling of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mmdiameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Transportation of all the Dismanteled material from the working site to Divisional Store except Distribution Transformer.
Scope of works for creation, Testing & commissioning of 63 KVA Distribution transformer sub station
Installation & commissioning of 11/0.433 KV, 63 KVA 3-Phase Distribution Transformer ( Dismentalled Transformer will be re installed)
Supply, Transportation, Erection of 9 Mtr Long PCC Pole including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
Supply, Installation, Testing & Commissioning of 11 KV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing & Fixing of Distribution Box for 63 kVA DTRwith MCCB for incomer & SFU's for OutgoingCircuits
Providing of Earthing of substation --Excavation of earth pit ofdia 650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wallthickness & length 2.5 mtr long as Per IS 1239.GIStrip for neutral earthing of size 25 mm x 3 mm forconnection of transformer body,G.O Set &lightening arrestor as per IS 2629/85, GI nuts &bolts,refilled with earth enhancement materialsand earth Chamber made of brick masonary withRCC slab cover.
Providing of Stone Pad 300 mmx300mmx75mm
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mmdiameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Dismantalling of existing HT Line
Dismantelling of 8/ 9 Mtr Long PCC Pole including refilling of soil & consolidating by ramming, watering etc.
Dismantelling of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Dismantelling of ACSR Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Dismatelling of 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Dismatellingof 11kV Polymeric composite Disc Insulator 12kV,min. failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Dismatelling of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Dismatellingof Danger Plates with Clamps
Dismatelling of Anti Climbing device with Clamps
Dismatelling of P G Clamps
Transportation of Dismantled material to Divisional Store.
Creation of Tapping Point/Isolation Point 2 No.
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
Supply, Laying & Stringing of ACSR Dog Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Supply, Laying & Stringing of ACSR Rabbit Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Supply Installation, Testing & Commissioningof 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Supply Installation, Testing & Commissioningof 11kV Polymeric composite Disc Insulator 12kV,min. failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of P G Clamps
M/S DAYAL BUILD TECH
M/S APR CONSTRUCTIONS
M/S SUDESH SONSTRUCTION ELECTRICAL MECHNICAL AND SUPPLIERS
Raina Builders and Suppliers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .