Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC VILL BATABARI PO DALGAON PS DALGAON DARRANG ASSAM 784116 | DARRANG | ASSAM | 784116 | ₹2.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.2 Cr+₹3,242.28 (0.01%)Rejected-AOC ASSAM AS | BARPETA | ASSAM | 781308 | ₹2.2 Cr+₹3,242.28 (0.01%) | L2 | Rejected-AOC L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Bid Security has not been furnished |
Tender Value
₹2.2 Cr
EMD Value
₹4.5 L
Closing Date
22 Jul 2021, 2:00 pmClosed
The Addl. Chief Engineer-cum-Director, PWD, BTC
O/o the Addl. Chief Engineer-cum-Director, PWD BTC, Kokrajhar
Const. of Guest House, Children Park, all side plaster, wall fencing, Rest room attached to stage, earth filling, wall painting, wiring and street light post with repairing of at Rowta Station under SOPD fund for the year 2019-20
2021_BTC_22142_1
No. 03/ACE/BTC/UDL(R and B)/2021-22/3
Open Tender
Civil Works
Item Rate
365 days
Udalguri
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,700
Principal Secretary, BTC, Kokrajhar
₹4.5 L
Yes
28 Sept 2021
8 Jul 2021
23 Jul 2021
8 Jul 2021
22 Jul 2021
8 Jul 2021
8 Jul 2021 - 22 Jul 2021
Amount
1.1. Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc, including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and soecified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil,
4.1.1. Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a). Brick on flat soling. (a) In ordinary soil
2.1.1. Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume Footing of Columns for RCC Building
2.1.3. Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone age of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Uoto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
3.2.1. Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2. Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
2.2.1. Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded sone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (1) Using Mixer Machine, (A) In substructure up to plinth level (Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser (b) M20 grade concrete or Prop. 1:1.5:3
4.1.4. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
4.1.8. 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4.
1.3. Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
11.2.3. Providing, fitting and fixing Coloured anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (iv) Prelaminated Board
12.4. Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made from extruded PVC stiles and rails made from rigid PVC multicavity hollow chamber section of size 90mm X 37mm (Toletance+ 1mm). The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws. PVC multicavity hollow section of size 105mm X 37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be filled with PVC panels of approved colour of size 100mm x 20mm. Then two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all complete as specified and directed at all levels. (Door fixtures and fittings to be measured and paid seperately)
11.1.1. Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections having thickness atleast 1.9mm of approved brand ( HINDALCO/ JINDAL /BHAGWATI SAI (with proof of purchase of ingot from primary producer)/ Other equivalent) without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). a) Side hung and Top hung windows and ventilators iii) 6mm coloured glass
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
5.1.5. 65 mm thick cement concrete floor consisting of 53 mm under layer of cement concrete in prop. 1:3:6 (1 cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 12 mm thick wearing coarse of cement sand plastering in prop. 1:2 laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
8.2.1. Grading roof for water proofing treatment with (b) Cement mortar (i) 1:3 (1 cement: 3 coarse sand)
8.2.2. Providing and laying six course water proof treatment with bitumen felt over roof consisting of first, third and fifth courses of blown or residual bitumen applied hot @ 1.45kg, 1.20kg and 1.45kg per Sqm of areas respectively, second and fourth courses of roofing with felt type 3 grade - I (hessain base self finished bitumen felt) and sixth and final course with stone grit 6mm and down per Sqm including preparation of surface, excluding grading complete.
13.2.2. (n) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with alkali resistant primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and also including preparing the surface even and sand papered smooth. (ii). Top coat
13.2.3. a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.2.3. b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
5.7.1.1. Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). b) Executive range Somany/ Orient/Nitco/Asian Make (ii) of size 400x400 mm and above
26.1.3. Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water. i.e. 1% solution.
26.1.4. Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
19.5. Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
19.2. Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
5.7.1.2. Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). b) Executive range Somany/ Orient/Nitco /Asian Make i) of size 200mmx300mm and above
19.5. Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plasterin in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work..... ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Const. of Rest House 1.1. Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completetion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including hailing out water where necessary as directed and specified. A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
4.1.1. Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materialsand if necessary dewatering, complete. (a) Brick on flat Soling
2.1.1. Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing stepts, walls brick works etc. as directed and specified including dewatering if necessary and curing complete (Shutering where necessary shall be measured and paid separately) (a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto Ist floor level) (a) Super Ductile (SD) TMT reinforcement bars.
(c) ISI approved Mild Steel reinforcement bar (M.S. Bar) (a) 6mm dia
3.2.1. Providing form work of 12mm thick plywood board so as to give a rough finish including centering shuttering, strutting and propping etc. 3.2.1.1. Column, pillars posts & struct of square/rectangular/ Polygonal in plain ar any shape like Tee/L etc.
3.2.1.2. Sides and soffits of beam, beam haunchings, cantilever girders bressumers, lintels and horizantal ties. a) For depth not execeding 1.00 M
3.2.1.3. Flat surface such as soffits of suspended floors roof landing slab Chajja etc. a) Floor etc. upto 200mm in thickness
2.2.1. Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinfor cement for reinforced cement concrete work (from work and reinforcement will be measured and paid separately) (I) Using Mixture Machine (A) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser (b) M20 grade concrete or prop. 1:1.5:3
(b) In super structure from plinthlevel upto 1st floor level. ii)Columns, pillars, posts, struts, suspended floor, roof, landing shelf and support, belcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (exceptspiral staircase and landing) including preparing the top surface and (N) Without using admixture, plasticiser (b) M20 grade concrete or prop. 1:1:5:3
4.1.4. Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed. (i) In sub-structure upto plinth level including dewatering if necessary b) In prop. 1:4
1.3. Earth/ sand filling in plinth layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading
2.1.3. Providing and laying 25mm thick damp proof course with cement concrete in prop. 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed.
18.7.2. Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties. .... etc. complete (ii) Size 125mm x 60mm (Single rebate)
4.1.8. 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick brick wall a) In cement mortar in proportion 1:4 (1 cement: 4 sand)
9.12.1. Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels.... etc. complete. (i) Decorative type face panel and block board core. iii) 35mm thick
11.1.1. Providing, fitting and fixing anodised aluminium windows and ventilators of standared section of approved section of approved brand (Hindalco/NALCO /Balco/Jindal etc. complete. (b) 3 Trah slidling window iv) 5mm frosted glass
10.3. Supplying fitting and fixing anodised aluminium decorated grill with anodised aluminium rectangular frame of 'F' and 'H' section fitted ... etc
18.3.2. Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or combination of following section of (i) Square (ii) Rectangular Hollow section of specification SHS/RHS and including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nut with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. (b) Using other ISI marked approved barnd tube 1) 60.30 OD (H) Black tube
8.1.35. Providing pre painted galvalume sheet roofing (P.P.GL) at all levels including fitting and fixing self drilling, self tapping screws complete ( Roof trusses, purlin etc. to be measured and paid separately) Tata Blue scope/Dyna roof/Wonder Roof or equivalent as directed by the department. (v) 0.80mm thick
18.1.36. Providing pre Painted Galvalume Sheet (PPGL) accessories (Ridges/Valley /Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete iv) 0.80mm
6.2.2. 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arise, internal roundred angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side, b) In cement mortar 1:4
B) on fair side b) In cement mortar 1.4
7.10.1. Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm /1200mm x 600mm with main runner 38 x 24mm cross tee 29mm x 24mm & wall angle 24mm x 24mm etc. A) Standard Ceiling of Everest make or equivalent as directed by the department i) Using 4mm thick F.C. board
9.4.1. Providing barge board of size 200mm x 25mm with 1st class wood Hollock/Bonsum timber including fitting and fixing with necessary wood screws etc.... Complete
5.1.4. 65mm thick cement concrete floor consisting of 50mm under layer of cement concrete in prop. 1:3:6 (1 cement: 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15mm thick wearing layer in cement concrete in prop. 1:1:2 ........ complete as directed.
19.3. Providing plinth protection with brick flat laid in cement mortar 1:4 and finished 15mm thick cement plaster in prop. 1:2 with a flating coat of neat cement finish.
19.5. Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plasterin in prop. 1:3 finished with a floating coat of sement slurry as directed with necessary shuttering for sides and earth work in Excavation of foundation trenches and refilling the sides after completion of work...... ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
5.7.2.1. Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floor, skirtings, risers and treads of step 15mm thick base of cement mortar in prop. 1:3 etc. (I) Normal range (Somany/orient/Nitco varmora/Jhonson make. a) of size 600mm x 600mm and above
13.2.2. (c) Applying one coat of distemper primer of approved brand and manufacture on wall surface after through brushing the surfaces free from mortar droppings.... etc. complete.
13.2.2. (f) Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give... etc.
13.2.3. (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.2.3. (b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new walls surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Raising low site at Rowta Station 1.4. Raising low site arround the Bldg. with approved soil obtainted from outside by truck carriage including breaking clods dressing etc. complete including paying
Children Park R.C.C. Bench (Double) with Tiles 1.1. Earth work in excavation for foundation trenches of walls, retaining wall, footing of columns, Pillars, septic tank etc etc, complete. A. Up to depth 2.00 m below the existing G.L. a) In ordinary soil.
4.1.1. Providing brick soling in foundation and under floor with stone/best quality pick Jhama brick, sand .....complete. b) Brick flat soling
2.1.1. Plain cement concrete work with coarse aggregate of size 30 mm to 32mm in foundation bed for footing steps, walls etc. as directed and specified including dewatering if necessary.. c) In Prop. 1:3:6
4.1.4. Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed. (I) In sub-structure upto plinth level including dewatering if necessary. b) In prop. 1:4
3.2.5. Providing form work of ordinary timber planking so as to given a rough finish including centering etc. etc. and concrete work 3.1.1.5. Flat surface such as rooftings of suspended floor, roofs, landing, cantiliver slab chajjah and the like. a) Floors etc. 200mm in thickness. ii) Using 25mm thick plank.
18.1.1. Supplying, fitting and fixing in position reinforcements bars conforming to relevant I.S. Code ... etc. b) TMT Bar, i) TATAISAIL, 12mm T.S
2.2.1. Providing and laying /reinforcement cement work etc, etc, complete. A)In Sub-Structure upto plinth level For sitting bench
4.1.8. 112mm thick 1st class brick nogged wall in cement including grading out joints etc. a) In Cement mortar 1:4
6.2.3. 15mm thick cement plaster in single coat etc. ..... complete (A) On rough side, c) In Prop. 1:5
5.7.1.1. Providing Ceramic tiles of approved quality size shapes and thickness not less than 6mm at NITCO brand on floors walls etc. complete. (c) Delux range (Orient/Nitco) etc. (I) Floor Tiles, a) Elegant 300mm x 300mm, b) White Cement
i) WALL TILES : Alba Beige, Alba Fawn, Chianti Basila Cream, Anica Fawn 300mm x 300mm b) White Cement
Construction of Statue as per market price
Supplying fitting and fixing complete etc. a) Zolna
Supplying fitting and fixing Seasagi etc. complete a) Standard Size
Supplying fitting and fixing sloping bench etc. complete a) Standard Size
Construction, finishing painting and playing decorative structure things, representive things replica etc.
CONST. OF CHAINLINK FENCING WITH RCC POST 1.1. Earth work in excavation for foundation, trenches of walls, retaining walls, footing, columns, steps, septic tank etc, including refiling the quantity as necessary after complete of work .... etc. A) Upto a depth of 2.00m below the existing G.L. i) in ordinary soil
4.1.1. Providing soling in foundation and under floor at all levels with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade ...... etc. etc. complete. a) Brick flat soling
2.1.1. Plain cement concrete work with coarse aggregate of size 30 mm to 32mm in foundation bed for footing steps, walls etc. as directed and specified including dewatering if necessary.. c) In Prop. 1:3:6
3.2.1. Providing form work of 12mm thick ply wood board so as to give a rough finish including centering, shuttering etc. complete. 3.2.1.1. Column, Pillars, Posts & Struts of squre/ractangular/polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2. Sides and soffits of beam, beam hunchings contiliver girders, bresumers, lintels and horizental ties.
18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. code for R.C.C. work/R.B. Walling including etc. complete. b) Other ISI approved TMT reinforcement bars (SRMB/ SAI/BISCON/X Tech) for Assam Type Bldg. Boundary wall etc. a) 8mm dia T.S. Post Jali
b)12mm dia T.S.
C) ISI approved M.S. rod strup for tie beam
2.2.1. Providing and laying plain/reinforcement cement concrete works cement, course sand 20mm down graded stone aggrigates including dewatering etc. (a) Using Mixer Machine A) In substructure upto plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap etc. N) Without using admixture, plasticiser. a) M 15 grade concrete or prop. 1:2:4
(b) In super structure from P.L. upto 1st floor level ii) Column, Pillars, post, struts, suspended floor, roof landing, shelf and support, balconey, lintel N) Without using admixture, plasticiser a) M 15 grade concrete in prop. 1:2:4
4.1.4. Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed. (l) In sub-structure upto plinth level Including dewatering if necessary. h) In prop. 1:4
4.1.8. 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor level. A) 112mm thick brick wall a) In cement mortar 1:4
17.10. Supplying fitting & fixing chain link fencing of 10 SWG G.I. wire 50mm x 50mm mesh fitted to M.S. angle iron post at 2000mm apart of specification detailed below including supplying fitting & fixing hooks, eye bolt with nuts, staples and bolts including three horizontal lines of G.I. wire etc.
6.2.2. 15mm thick cement plaster in single coat on single or half brick wall for Interior plastering upto 1st floor level including aries, internal rounded angles, not exceeding etc..... complete as directed. A) On rough side, a) In cement mortar
B) on fair side
13.2.3. Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar dropings and other foregin matter and including prepairing the surface etc. complete.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
R.C.C. Stagging with Pump House Sand Filter & Reservoir 1.1. Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc.including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Up to a depth of 2.00m below the existing ground level. (a) in ordinary soil
4.1.1. Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling
2.1.1. Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). a) in prop 1cement: 3 sand :6 coarse aggregate by volume
18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ .R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars Column Jali 10mm dia both way
3.2.1. Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2. Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
3.2.1.3. Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness
3.2.1.6. Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like
2.2.1. Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining wait, wals on septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser (b) M20 grade concrete or Prop. 1:1.5:3
4.1.4. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (1) In Sub-structure upto plinth level including dewatering if necessary (b) in proportion 1:4.
4.1.8. 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4.
1.3. Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (B) On fair side b) In cement mortar 1:4
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (B) On rough side, b) In cement mortar 1:4
18.4.1. Providing and fixing in position collapsible M.S. shutters with vertical channels 20mm x 10mm x 2mm braced with flat iron diagonals 20mm x 5mm size with top and bottom rails of T-iron 40mm x 40mm x 6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
10.2. Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, squre or round M.S bars with round headed bolts and nuts or screws (c) Fixed to Brckwork/P.C.C/R.C.C.
25.12. Providing precast R.C.C slab over drain, septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering, curing etc. complete including fixing in position as directed. a) 100mm thick slab
13.7.2. Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a) with ready mixed "red-lead/ red oxide" primer.
13.7.4. Panting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICl paint/ J & N paint/ Nerolac).
13.9.3. Finishing old/ new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish of Sandex Matt brand of Snowcem India Ltd. of required shade after clering and clearing the surfaces etc. including scaffolding complete as directed at all levels (two coats).
Deep Tube Wall 5.3.4. Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. ii) Bore hole of 100mm diameter.
5.3.5. Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant is codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (I) G.I. pipe (a) TATA/SAIL (Medium) socket should be welded to the pipes. iv) 100mm diameter
5.3.6. Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes - complete as directed. (a) TATA/SAIL (Medium) socket should be welded to the pipes. iv) 32mm diameter.
5.3.12. Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained.
5.3.13. Flushing, clearing, washing and watering of the tube well
Sanitary & Water Supply 3.1.1. Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls (b) 40 mm dia (Medium) (i) Using Tata make
d) 25 mm dia (Medium) (i) Using Tata make
3.2.1. Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand as directed and specified. (G.I. & C.P pipes will be measured separately) (II) Jaquare make (a)Continental /Clarion (ii) Bibcock long thread
3.17.1. Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. (b) 40
3.17.3. Supplying fitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia (Heavy type)
5.4.2. Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Pation make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 2000 Lt capacity
SEPTIC TANK 1.1. Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil Septic Tank
4.1.1. Providing soling in foundation and under tloor with stone/ best quality picked jhama brick, sand (a) Brick on flat soling. Septic Tank
2.1.1. Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for (a) In prop 1 cement: 3 sand :6 coarse aggregate by volume Septic Tank
2.1.1. Supplying fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) 8mm dia
c) ISI approved Mild steel reinforcement bar(M.S.Bar) Stirrups 6mm dia.
3.2.1. Providing form work of 12mm thick Plywood Board so as to give a rough finish including………. 3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and Septic Tank Tie Beam
2.2.1. Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down (A) In substructure up to plinth level (a) M15 grade concrete or Prop. 1:2:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (i)In Sub-structure upto plinth level including dewatering if necessary. (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (i)In Sub-structure upto plinth level including dewatering if necessary. (b) In proportion 1:5.
4.1.4. Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to A) On rough side (b) In cement mortar 1:4
5.1.2. 25 mm thick cement concrete topping 1:2:4 (1cement: 2 coarse sand : 4 coarse aggregate of 12 Septic Tank Floor
1.48. Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 25 kg. Septic Tank
Electrical Estimate 2.1 :- Wiring for light/fan/call bell point with 2 x 1.5 sq.mm. P.V.C. insulated single core unsheathed industrial ( Multistrand) cable FR conforming to IS - 694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deptt.) in Surface/recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS : 9537 Part - III Conduit (Berlia/AKG /precision/presto plast/polycab/MW or equivalent make as approved by the Deptt.) including 6 AMP FLUSH TYPE SWITH/BELL PUSH (Anchor penta/ Gold medal / Kolor kany. Kom/Havells or Equivalent Make as Apprved by the Deptt.) GI/MS switch board ( ISI marked) with pkenolic laminated sheet cover ceiling rose ( Anchor penta/ Gold medal/ Kolor kany. Kom / Havells or equivalent make as approved by the Deptt.) etc. 2.1.1 :-Short point up to 3 metre length.
2.1.2 Medium point up to 6.00 metre. Length.
2.1.3 Long point up to 10.00 metre. Length.
2.2:- Wiring to 5 a pin 6 Amps plug point with 1.5 sq. Mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage up to 1100 volts (Fnolex/ RR Kabel or Equivalent make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked Is : 9537 PART - III rigid PVC conduit (Berlin/ AKG/ Precision/presto plast/ polycab/MW or equivalent make as approved by the deptt.) 2.2.2 Medium point up to 6.00 metre. Length
2.3:- Wiring for 5/6 pin 16 Amps power plug point with 4 sq. Mm P.V.C. insulted single core unsheathed indusrrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR kabel or equivalent make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta/ Gold madal/ kolor kany. Kom/Havells or equivalent make as approved by the Deptt.), GI/MS switch board (I.S.I mark with phenolic laminated sheed cover earth continuity with 2.5 sq.mm cable to the 3rd pin of the socket as required complete with 20 mm dia. 2mm thick/heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/AKG / Precision/ presto plast/polycab/ MW or equivalent make as approved by the Deptt.) 2.3.2 Medium point up to 6.00 metre. Length.
2.7 :- Wiring for drawing sub- main line with P.V.C. insulated single core unsheathed industrial ( Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR kabel or Equivalent Make as approved by the Deptt.) PVC conduit 2.7.1 with 2 x 2.5 sq. Mm. + earth continuity with Ix 1.5 sq. Mm. In 20 mm. Dia, 2mm thick/ heavy rigid PVC IS: 9537 part - III conduit.
2.7.2 with 2 x 4 sq. Mm. + earth continuity with 1x 2.5 sq. mm, cable in 20 mm. Dia. 2mm thick/ heavy rigid PVC IS: 9537 part - III conduit.
2.7.3 with 2 x 6 sq. Mm. + earth continuity with 1x 4 sq. Mm. Cable in 25 mm. Dia, 2mm thick/heavy rigid PVC IS: 9537 part - III conduit.
2.9:- Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR kabel or Equivalent make as approved by the Deptt.) in surface/ recessed PVC 20mm. Dia 2mm thick/heavy ISI marked IS:9537 PART- III rigid PVC conduit (Berlia/ AKG / precision/ presto plast/ polycab/ MW or equivalent make as approved by the Deptt.) wiring system. 2.9.4 With 4 x 10 sq. mm. + earth continuity with 2 x 6 sq.mm. Cable in 40 mm. Dia. 2mm thick/ heavy rigid PVC IS: 9537 part – III conduit.
2.10 :- Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistand) cable Fr conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet ( Anchor penta/Gold medal / Kolor kany. Kom/Havells or Equivalent make as approved by the Deptt.) make earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C./ conduit wiring system. When fitterd on same board of light and fan.
11.12 :- Supplying and fixing of polished brass bracket of 18 S.W.G, 25 cm long cast back plate and brass.
11.26 :- Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/ decorative bracked/bulk head fitting/ pendent holder etc. As specified and directed by the deptt.
11.32 :- _Supplying and fixing of call bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt. as required.
14.1 :- Supplying fitting and fixing industrial plug & socket in surface mounting SPN sheet steel power painted MCB DB incorporated with MCB DIN rail neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 14.1.1 20A Capacity. (C&S, Havells, Standard or equivalent make as approved by the Deptt.)
15.4 :- _Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.4.1 (Schneider neo beak, C&S, Havells, standard, or equivalent as approved by the Deptt.) 15.4.1.1 4way SPN double door.
5.8. Supplying with fitting and fixing sheet steel, phosphatised, power painted dust & vermin proof double door (IP-43) surface mounting TPN MCB DB incorporated with bas bar, Neutral link, Earth bar and din rail etc. fitted on wall with grouting nuts & bolts as reqd. Complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1. (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 15.8.1.1 4 way TPN (4+12) Double door.
16.1 :- Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making | necessary connection as approved, specified and directed by the deptt. 16.1.1 B series (Schneider mg, legrand, Hager, Crabtree Xpro make) 16.1.1.1. 6 to 32A
16.3 :-_Supplying with fitting and fixing DP 10 KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B Series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.2. 40A
16.6 :- Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the Deptt. 16.6.1 B Series (Schneider MG, legrand, Hager, Crabtree Xpro make) | 16.6.1.3. 63A
16.16 :- Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (Without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.16.1. 25 KA 415V 50Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 16.16.1.3 40A
16.17 :- Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics = Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete specified and directed by the deptt. 16.17.1 35/36 KA 415V 50 Hz 4P MCCB 16.17.1.1. 160A
16.44 :- Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection) powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.44.1. C & S. Havells, Indo Asian, HPL, GECO make) 16.44.1.2. 100A
22.7 :- Supply, installation & testing of G.I earth station with perforated 40 mm dia and 4.50 Metre long heavy duty G.I pipe with necessary 40 mm dia. G.I Fittings such as Soket, Tee, elbow, nipple and 50mm x 40mm G.I. reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of 1 both inner & outer surface of wall as specified and directed by the deptt
22.10 :- Supplying, installation & testing of copper plate earth station with 600mm x 600mm x 3 mm copper earth plate with necessary 40mm dia G.I. medium duty watering pipe with G.I. Fittings such as socket, Tee, elbow, nipple and 50 mm x 40 mm G.I. reducing socket for funnel including locking arrangement with 300 mm x 300mm x 6 mm C.I hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
22.12 :- Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance group in location of high soil resistivity as and when required and specified by the deptt.
22.13 :- Extra for using salt 5 K and Charcoal 96 K in G.I/Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt
22.16 :- Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
22.31 :- Supplying, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. Single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof RCC slab, top of column etc. As specified and directed by the deptt.
27.1 :- Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the Department [Without regulator) 27.1.3 premium model 1400 mm Sweep. (ORIENT PSPO make) / premium model 1400 mm Sweep SS-390 Deco.(Havells make)
27.2 :- Supplying including fitting and fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the department. 27.2.1 Domestic. 27.2.1.2. power flow 225 mm sweep (ORIENT make)
27.6 :- Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic Type
29.1 :- Supplying with installation, testing and commissioning of Hi - wall 4 STAR rating, non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection up to 5 m between the room unit and door unit as approved by the Deptt. And directed by the department. 29.1.2 1.5 Ton capacity 29.1.2.2 Carrier make Dura cool star premium
5 29.9 :- Supplying with fitting, and fixing of Angle iron framing made 50 mm x 50mm x 5 mm size angle iron for accommodation of 1.00 Ton to 2.00 Ton window/split type A.C. Machine.
30.11 :- Supplying with fitting and fixing single phase D.O.L Starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 30.11.2 Overload Relay Range 6.0 - 9.3 Amps for 3.7 KW
31.1:- Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee - Dee / V GUARD / VERTEX/ INDO/ VENUS make) 31.1.6 3.0 KVA Automatic Input 90-280 v out put 200-240 V
32.1 :-Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2 x 10 sq mm. 3 x 10 sq mm, 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 5650/1100V grade as per IS 7908 (part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air ( as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc. Complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nico/ Havells/ RPG/CCI/Polycab/Gloster /Finolex make or equivalent). 32.1.4. 4 Core A2XWY A2XFY 32.1.4.9. 95.00 Sq.mm. 4 Core armoured U.G. cable
32.11 :- Supplying and laying of following size Solid Aluminium conductor up to 10 sq mm balance strandd conductor, XLPE Insulated cores laid up, PVC tape inner sheathed, unarmoured/rmour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2 x 10 sq mm. 3x10sq mm, 4x6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed 650/1100V grade as per IS 7908 (part1) 1988 laid in air or through existing cable trench/ duct/cable tray/ HDPE puipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) 32.11.1 Core - 1, A2XWY 32.11.1.4. 4x50 Sq. mm single core armoured cable
35.1:- Supplying, installation testing and commissioning of the following rating copper would indoor/out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approved of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as amended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA Guidelines for losses along with LV Enclosure. 35.1.1. 25 KVA, 50Hz. 11/0.433 KV. Oil filled transformer with off circuit tap charge.
36.3 :- Supplying and erection PSC pole 9.75 metre long, the pole is to be erection in 1:3:6 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C. base foundation 15 cm x 60 cm x 60 cm including edge brick soiling and plastering above G.L. portion (0.30 metre) complete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department.
36.5 :- Supplying and erection of H.T. stay set complete (Galvanized) with 19mm dia x 1.8m long stay rod anchor plate of size 30cm x 30 cm x 6.4 mm thimble stay clamps tube buckle (19mm x 60 cm) 7/3. 15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6 (1 cement: 3 Course sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required and as directed by the department.
36.7 :- Supplying and fitting fixing of galvanised channel of 75 mm x 40 mm x 65mm x 2200 mm long complete with clamps, blots nuts etc. as required and as directed by the department
36.14 :- Supplying and erection of 11 KV pin insulator (poly) with G.I. pin, folts and nuts coach screw etc, as required and as directed by the department.
36.16 :- Supplying and erection of 11 KV Disc insulator (poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
36.22 :- Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
36.23 :- Supplying and fixing of 11 KV 150 AD.O. fuse set complete as required and as directed by the department.
36.24 :- Supplying and fixing of 11 KV 5 KA Lighting arrestor (poly) set complete as required and as directed by the department.
36.25 :- Supplying and fitting fixing pole clamp complete as required and as directed by the department.
36.30 :- Supplying and string up AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department.
36.32 :- Supplying including installation of 4" dia. C.I earth pipe complete as required and as directed by the department.
39.6 :- Supplying including installation, connection as approved by the the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET, Single phase with steel cable rope and submersible cable complete as directed and specified by the deptt. 39.6.7 Single phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/V-Guard/ Calma make) suitable for 100mm bore well and above. 2 HP STAGE to 30 with control panel.
ECBC.3.28 :- Supplying, Installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. Directly on wall / ceiling including connection with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department ECBC. 3.28.1 LED Lamp indoor application, operating voltage 90V-250V, 12V DC I. Model GNII-2 or equivalent, LED Lamp with mains input (Make Philips/Bajaj/Schneider/ Havells)
16.16 :- Supplying with fitting and fixing panel mounting open execution 25KA 415V 5OHz 4P MCCB (Ics=lcu, adjustable Ir setting 0.7) (Without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.16.1.4 63A
DTR fencing (Rate as per APDCL rate)
Payment to be need to the APDCL authority for load security.
Rest Room 1.1. Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C insulated singal core unsheathed industrial (Multistrand) cable FR conforming to IS-694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/ RR kabel or Equivalent make as approved by the Deptt. with flat 19 mm ISI market casing 'n' capping (AKG / precision/presto plast/polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type swith/ bell push (Anchor penta Gold medal / Kolor kany. Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet kany. Kom / Havells or equivalent make as approved by the Deptt.) etc. Complete as directed and specified by the Deptt. 1.1.1 Short point up to 3.00 metre. Length
1.1.2 Medium point up to 6.00 metre. Length.
1.1.3 Long point up to 10.00 metre, length
1.3 : Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694; 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG/ precision presto plast/polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type swith (Anchor pental Gold medel/ kolor kany. Kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. 1.3.2 Medium point up to 6.00 metre. Length.
1.8 :- Wiring for drawing Sub-main line with P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR kabel or equivalent make as approved by the Deptt.) in surface flat ISI market casing 'n' capping (AKG / precision/presto plast/polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 with 2 x 2.5sq.mm + earth continuity with 1x1.5 sq.mm. In flat 19 mm ISI market casing ‘n' capping system.
1.8.2 with 2x4 sq. mm. + earth continuity with 1 x 2.5 sq.mm. Cable in flat 19 mm ISI market casing 'n' capping system
1.8.3 with 2 x 6 sq. mm + earth continuity with 1 x 4 sq. mm. Cable in flat 25mm ISI market casing ‘n' capping system.
1.11 :-wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C insulated single core unsheathes industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or equivalent make as approved by the Deptt.) including providing & fixing 5 pin 6 amp socket outlet (Anchor penta / Gold medal / Kolor kany. Kom/Havells or equivalent make as approved by the Deptt.) and 6 amp flush type switch................of light and fan.
11.12 :- Supplying and fixing of polished brass bracket of 18 S.W.G, 25 cm long cast back plate and brass
11.16 :- Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including connection as approved by the Deptt. As required. ( Without lamp).
11.26 :- Supplying and fixing of 18/20 Watt CFL lamp in the existing batten holder/angle holder/ decorative bracket/bulk head fitting/ pendent holder etc. as specifid and directed by the deptt.
5.4 :- Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.4.1 (Schneider neo beak, C&S, Havells, standard, or equivalent as approved by the Deptt.) 15.4.1.1 4 way SPN double door.
16.1_ :- Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B series (Schneider mg, legrand, Hager, Crabtree Xpro make) 16.1.1.1. 6 to 32A
16.3 :- _Supplying with fitting and fixing DP 10 KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B Series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.3.1.2. 40A
22.7 :- Supply, installation & testing of G.I earth station with perforated 40 mm dia and 4.50 Metre long heavy duty G.I pipe with necessary 40 mm dia. G.I Fittings such as Soket, Tee, elbow, nipple and 50mm x 40mm G.I. reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
22.12 :- Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance group in location of high soil resistivity as and when required and specified by the deptt.
22.16 :- Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 :- Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the Department (Without regulator) 27.1.3 premium model 1400 mm Sweep. (ORIENT PSPO make) / premium model 1400 mm Sweep SS-390 Deco. (Havells make)
27.6 :- Supplying fitting and fixing of ceiling fan regulator including connection etc. Complete as required. 27.6.2 Electronic Type .
ECBC.3.28 :- Supplying, Installation, testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. Directly on wall / ceiling including connection with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. ECBC. 3.28.1 LED Lamp indoor application, operating voltage 90V – 250V, 12V DC I. Model GN11J - 2 or equivalent, LED Lamp with mains input (Make Philips/Bajaj/ Schneider/Havells)
15 KVA D.G. Set and D.G. Shed. 22.7 :- Supply, installation & testing of G.i earth station with perforated 40 mm dia and 4.50 Metre long heavy duty G.I pipe with necessary 40 mm dia. G.I Fittings such as Soket, Tee, elbow, nipple and 50mm x 40mm G.I. reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
22.12 :- Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance group in location of high soil resistivity as and when required and specified by the deptt.
22.16 :- Supplying & laying of 8 SWG Copper. Earth from Earth Electrode ( below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
32.1:-Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour ( Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2 x 10 sq mm. 3 x 10 sq mm, 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 5650/1100V grade as per IS 7908 (part 1 ) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air ( as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering , Sand cushioning etc. Complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nico/ Havells/ RPG/CCI/Polycab/Gloster /Finolex make or equivalent). 32.1.1 2 Core A2XWAY A2XFaY 32.1.1.5 25.00 Sq. mm2 Core armoured U.G. cable
41.2 :- Supplying including installatio, testing and commissioning of Air/Water Cooled Disel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3 Phase 0.8 p.f. mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual silencer.,4) AMF Control Panel .5) Suitable batteries with lead., 5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification as per manufacture. (RANGE FROM 5 KVA TO 625 KV. Kirloskar green/ bliss, Leyland, Volvo Penta, Perkinson, Mahindra Greaves, Escort engine and Kirloskar, Stamford, Leroy somer or equivalent alternator. 41.2.1.5. 15-1-177x 1050 x 1550- 900 Kg A/C
DG Shed 1.1. Earth work in excavation in foundation tenched]s wall, footing and column, steps, septic tank etc. including refilling the quality as necessary…… as specified. (A) Up to a depth of 2.00m G.L. (a) In ordinary soil.
4.1.1 Providing brick soling in foundation and under floor with stone/best quality picked jhama brick sand packed and laid to level and in panel after preparation the sub graded as directed including all labour and materials and if necessary dewatering completed. (a) Brick flat soling.
2.1.1 Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified.... ..complete.(b) In prop. 1:3:6
18.1.1:- Supplying, fitting and fixing in position reinforcement bers conforming to relevant I.S. code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per .... .............etc. complete. (a) TATA/SAIL (ii) Super Ductile TMT bars.
(c ) M.S. bar (for stir up)
2.2.1. Providing and laying plain/reinforcement cement concrete works cement with coarse sand & 20mm down graded stone agg. including dewatering if necessary and curing complete but excluding cost of form work sad reinforcement for reinforce cement concrete work. . (i)Using mixture machine. (A)In sub-structure up to plinth level. Foundation, footing, column with base etc. (I) M - 15 or in prop. 1:2:4
(B)Super structure from plinth level uplst level. (ii) Column, Pillar, Post, Structure…1:2:4 nosing.
4.1.4 Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure of the plinth level. (c) In prop. 1:4
4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level, (A) 112m thick brick wall. (a) In cement mortar in proportion 1:5
6.2.2:- 15 mm thick cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and ............. complete as directed. (A) On rough side. (b) In cement mortar. 1:4
5.1.4:- 65mm thick cement concrete floor consisting of 50mm under layer of cement concrete in prop. 1:3:6 and 15mm thick wearing layer in cement concrete in prop. 1:1:2 laid in panels and finished with as floating coat of neat finish including curing etc. complete as directed.
3.1.1 :- Providing form work of ordinary timber planking do as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-site reinforce concrete and plain concrete work in. (3.1.1.1) Foundation, footing, base of columns, pile cap raft and mass concrete Work etc. (b) Using 25mm thick plank.
3.1.1.3. Columns, pillars, post and strut. (a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank.
9.2.1 :- Providing undressed wood work in roof truss, rufter, purling, tie and likes including hoisting and fixing in position with necessary spikes, nails including M.S. Straps with bolt and nuts etc. (a) With hillock/Sundi/Sam
8.1.1:- Providing corrugate galvanized iron sheet roofing of TATA SHAKTER SAIL including fitting and fixing necessary galvanized J or L hooks. Bolts..............purlin etc. (a) 0.45mm thick.
10.2:- Providing corrugate galvanized iron sheet roofing of TATA SHAKTEE/ SAIL including fitting & fixing necessary galvanized screw/washers etc. complete as directed.
10.2 :- Providing fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/opening with M.S. Flats at required.. .......or screws. (I)Ornamental grill. (c) Fixed to brick /R.C.C
8.4.1 - Providing and fixing in position collapsible M.S. shutter with vertical channels 20mm x 10mm x 2mm braced with flat iron diagonals 20mm x 5mm size with top and bottom rails of T iron 40mm x 40mm x 6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, propers handles including applying a priming coat of red lead paint.
9.9.2 :- Providing fitting and fixing full panelled doors/windows including oxidized M.S. but things ( 100mm x 75mm x 3.55mm) with necessary screws (other fittings to be and paid separately) (B) With 1st class local wood (Gamari/Hollock) (ii) 35mm thick
9.1.2 :- Providing wood work in frame of doors and window clerestory window and other similar works……………… specified. (B) with 1st class timber (Bonsum / Sundi )
13.2.2 :- f) Distempering with dry distemper of approved brand and manufacture (two coats) and required shade on new wall surface to give an even shade, over and including priming coat of white priwer after thoroughly brushing the surface free from mortar ...........smooth.
13.2.3 (b) :- Finishing wall with water proofing cement paint of approved brand and manufacture and required share on new wall surface to give an even after thoughly brooming the surfaces to remove all dirt and remains of loose powder materials.
High Mast light 2.7 :- Supply, installation & testing of G.i earth station with perforated 40 mm dia and 4.50 Metre long heavy duty G.I pipe with necessary 40 mm dia. G.I Fittings such as Soket, Tee, elbow, nipple and 50mm x 40mm G.I. reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
22.12 :- Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance group in location of high soil resistivity as and when required and specified by the deptt
22.20 :- Supplying & laying of following size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting soldering & making necessary connection as approved, specified and directed by the deptt.
32.1:-Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour ( Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2 x 10 sq mm. 3 x 10 sq mm, 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 5650/1100V grade as per IS 7908 ( part 1 ) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air ( as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering , Sand cushioning etc. Complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nico/ Havells/ RPG/CCI/Polycab/Gloster /Finolex make or equivalent). 32.1.1. 2 Core A2XWAY A2XFaY 32.1.4.4. 16.00 Sq. mm 4 Core armoured U.G. cable
25.4 :- Supplying and Installation and Commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m x 1.00 mx 5.50 m made of 16 SWG (1.66 mm) thick CR sheet and 25 mm x 35 mm x 6 mm size angle and 35 mm x 6 mm flat iron having 4 nos legs at the bottom and G.I sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coat of enamelled paint. The panel board is to be erected in 1:3:6 pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer-1 no 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos. /32 A DP MCB 3 Nos/32 A DP RC BO - 3 Nos 3. 25 mm x 5 mm size 4 strip copper Bus - Bar - 1 set 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. 5. Surface mounting timer switch - 1 no. 6. 63 Amp Bakelite HBC fuse kit -Kat - 3 Nos
Providing installation testing and commissioning of 20 Metre High mast Tower polygon Shape with 8 Nos of 250 W LED Light with fitting as per following electrification. 1. 20 Metre Polygon High Mast with accessories. 2. Mechanical components including head frame and pulley assembly, winch bracket carriage ring, luminaries, CG Box, | Manufactured Arms Resting bracket, Guide ring compensating disc, lighting arrestor etc. 3. Wire rope, safety rope, D-shuckle clamp, Nuts & Bolts. 4. Cable, foundation accessories which assembly distribution box, power motor, Top dia - 150mm, Bottom - 410 mm, top thickness3 mm and bottom 4 mm ( Bajaj make)
SANITARY INSTALLATION WORK 1.4. Providing fitting and fixing Vitreous china Dual Flush /Floor Mounted Coupled/Extended water closet (European type W.C. pan 400mm high) with seat andiead, CP brass hinges and rubber buffers, CI/MS brackets, 40mm dia flush band with fittings including painting of fittings and brackets, required. (Flushin Cistern to be paid separately) 1. Extended Type xv) Nano inclusive of seat cover and fittings (Ct No. 92075) (P Trap)
1.7. Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standared flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. B) Hindware make (iv) Sensomatic Urinal with ACC (Cat No. 60013)
1.13. Providing vitreous china wash basin with CI/MS bracket etc. complete (A) Parry ware make (a) White
1.18. Providing fiting and fixing Mirror with plastic fram of size 500mm X 400mm complete as directed and specified. (A), Parry ware make (a) Size 500mm X 400mm
1.21. Providing fitting and fixing C.P. towel roll complete as directed and specified. (B) Sona Make (iii) Towal rail Deploment (600mm long) (Cat No. TR 0605).
1.36.4. Supplying fitting and fixing H.C.I plain single equal juction etc. complete. (ii) 100mm dia
1.56. Supplying fitting and fixing wall moulded/floor moulded shower enclosed…. Etc. complete (c ) ESP ira standing walk in enclouser 1200mm X 1950mm.
1.54. Supplying fitting fixing CPVC pipes having thermal stabily for hot and cold water supply etc. complete as directed. (f) 50mm dia
NIP DUTTA SAHARIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .