Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹54.5 CrAccepted-AOC NO 72 T H ROAD CHENNAI CHENNAI TAMIL NADU 600081 | CHENNAI | TAMIL NADU | 600081 | ₹54.5 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹55.8 CrRejected-AOC | ₹55.8 Cr | 2 | Rejected-AOC L2 |
| 3 | 3₹66.0 CrRejected-AOC REGISTERED OFFICE CORPORATE OFFICE OUTER RING ROAD NAGAVARA BENGALURU KARNATAKA 560045 | BENGALURU URBAN | KARNATAKA | 560045 | ₹66.0 Cr | 3 | Rejected-AOC L3 |
Tender Value
₹59.0 Cr
EMD Value
₹1.5 Cr
Closing Date
21 May 2020, 4:00 pmClosed
CEO SCTL
4th floor Felicity square statue
Implementation of Intelligent Traffic Management System Adaptive Traffic Control System and City Surveillance System on various junctions including setting up a Traffic and Safety Command Control Centre
2019_SCTLT_330460_1
SCTL-PRJ/241/2019-IT
Global Tenders
Miscellaneous Works
270 days
thiruvanthapuram
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
Online
₹1.5 Cr
Yes
office of SCTL
12 Oct 2020
19 Dec 2019
22 May 2020
19 Dec 2019
21 May 2020
19 Dec 2019
7 Jan 2020
Amount
CIVIL WORKS
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Disposal of excavated earth by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours formovement/ plying of load carrying motor vehicle of 3.5 cum or more.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-inCharge.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
Supply and installation of Galvanized 'T' shape Cantilever Pole of height 7.5m,3m Arm for ACTS including all necessary fittings, etc.complete, as per the drawing and direction of Engineer-in-charge
Supply and installation of Galvanized 'I' shape Standard Pole of height 6m for ACTS including all necessary fittings, etc.complete, as per the drawing and direction of Engineer-in-charge
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing of 40mm PLB HDPE Ducts with solid permanently solidly lubricated Silicore in inner layer for ICT fibre cables conforming to ASTMF 2160, ASTM D 2444 and /or equivalent Indian standard. The outer layer shall be in Color approved by Engineer-in-Charge and shall be free from visual defects like blisters, shrink holes, flaking, scratches, groove lines & surface roughness, middle layer shall be translucent, And the inner layer shall be having permanently lubricated lining of Sili-core. The inner surface of the ducts shall be straight spirally ribbed & shall be of a configuration for faster installation of cables. Wall thickness(mm) of each of the ducts Excluding rib height shall be 2.9mm±0.3mm. couplers every 500 meter for duct jointing shall be provided. The coupler shall be used to join two HDPE pipes. It should either snap fit or Split type. The jointing shall meet the air pressure test of 15 Kg/cm2 for a minimum period of 2 hours. 2 End Plugs every 4 meters of pipe length shall be provided. End Plugs shall be used to seal the end of ducts so as to prevent any ingress of water/dirt etc. testing and commissioning. The rate is inclusive of required specials and fittings wherever necessary. ISO Requirements- ISO 9001, 14001, 18001 as per design drawing technical specifications and directions of Engineer in charge.
Micro Trenching by Groove cutting required for Power and Communication supply,including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 320 mm and 150 mm width, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering and finishing matching to the existing road surface etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Adaptive Traffic Control Systems
Traffic Signal Controller (As per technical specifications mentioned in RFP document)
Vehicle Actuated Detector/Detection System (As per technical specifications mentioned in RFP document)
Vehicular Countdown timer with 3 Digit Dual Colour (As per technical specifications mentioned in RFP document)
Traffic Light Aspects - RED -300 dia Red Lamp with round retrofit (As per technical specifications mentioned in RFP document)
Traffic Light Aspects - Green-300 dia left Green lamp with round retrofit (As per technical specifications mentioned in RFP document)
Traffic Light Aspects -Green-300 dia Green straight lamp with round retrofit (As per technical specifications mentioned in RFP document)
Traffic Light Aspects - AMBER-Green-300 dia Amber lamp with round retrofit (As per technical specifications mentioned in RFP document)
Pedestrian countdown timer with 2 Digit dual camera (As per technical specifications mentioned in RFP document)
300 mm dia red lamp with round retrofit for stop man (As per technical specifications mentioned in RFP document)
300 mm dia green lamp with round retrofit for walk man (As per technical specifications mentioned in RFP document)
Electricity requirement -power supply unit
Cu-3 Core, 2.5 sqmm Armoured Cable (As per technical specifications mentioned in RFP document)
Cu-8 Core, 1.5 Sqmm Armoured Cable (As per technical specifications mentioned in RFP document)
Cu-16 Core, 1.5 Sqmm Armoured Cable (As per technical specifications mentioned in RFP document)
Testing and commissioning for 57 junction (As per market rate)
Junction Box / Cabinets (As per technical specifications mentioned in RFP document)
UPS with Battery (800 VA) (As per market rate enclosed in DPR)
8 Port Industrial grade Ethernet Switch (Access Switches) as per specifications
Server /ICCC/TSCCC access (As per technical specifications mentioned in RFP document)
ATCS Software (As per technical specifications mentioned in RFP document)
Solar Panel (1000 Watt) (As per technical specifications mentioned in RFP document)
Traffic Management and Surveillance System
Supply, Installation, Testing and Commissioning of e-challan facility with all the necessary accessories to complete the work
Supply, Installation, Testing and Commissioning of Red Light Violation Detection (RLVD) with ANPR and Preloaded (Embedded) Software in Local Processing Unit with licenses for designed number of cameras as required
Supply, Installation, Testing and Commissioning of Speed Violation detection system with ANPR and Preloaded (Embedded) Software in Local Processing Unit and licenses as required
ANPR Software Camera Connection License for existing locations
RLVD/Evidence/Context Software Camera Connection License
RLVD cum evidence Camera as per specifications
ANPR Camera as per specifications
Speed Violation Detection (SVD) system for existing location
SVD system for Non Junction Location - (Venpalavattom)
Model 1 : Supply, Installation, Testing and Commissioning of Variable Messaging Sign with size 2.88 x 0.96 M LED multi color display unit (per board) including Media Player, Media Player license, 3G Dongle, Pixel pitch of LED display shall be maximum of 10mm space, display colour shall be with real full colour, support showing real time information with all the necessary accessories to complete the work
Model 2 : Supply, Installation, Testing and Commissioning of Variable Messaging Sign with size 3.84 M X 1.92 M LED multi color display unit (per board) including Media Player, Media Player license, 3G Dongle, Pixel pitch of LED display shall be maximum of 10mm space, display colour shall be with real full colour, support showing real time information with all the necessary accessories to complete the work
Model 3 : Supply, Installation, Testing and Commissioning of Variable Messaging Sign with size 1.92 x 0.96 M LED multi color display unit (per board) including Media Player, Media Player license, 3G Dongle, Pixel pitch of LED display shall be maximum of 10mm space, display colour shall be with real full colour, support showing real time information with all the necessary accessories to complete the work
ANPR Software Camera Connection License for new locations
RLVD/Evidence/Context Software Camera Connection License for new locations
Speed Violation Detection (SVD) system for new location
RLVD cum evidence Camera for new locations
ANPR Camera for new locations
Surveillance System
Standard PTZ controller with 3-axis joysticks & Keyboard for control of pan, tilt, zoom and auxiliary camera functions as per technical specifications in RFP
Video Management System (VMS) as per the specifications functionalities enclosed in RFP
Forensic Analytics as per the specifications & functionalities mentioned in the RFP
Supply and installation of Video Analytics software as per the Use Cases defined in the RFP
Licenses for Video Analytics (Channels for Person Tracking across several cameras as per Annexure 3)
Face Recognition Software Application
VMS Recording Licenses for Cameras
2 MP PTZ Camera for Surveillance for existing locations as per technical specifications in RFP
5 MP Fixed Camera for Surveillance for existing locations as per technical specifications in RFP
Face Recognition Camera as per technical specifications in RFP
Face Recognition Software License
2 MP PTZ Camera for Surveillance for new locations as per technical specifications in RFP
5 MP Fixed Camera for Surveillance for new locations as per technical specifications in RFP
VMS Recording Licenses for Cameras
Data Centre, Networking and Connectivity
Rack Servers as per MSI design
Work Stations with 3 LED monitors as per latest generation 64 bit processor
KVM Switch with LED monitor
Primary Storage box
70 inches Panel for DLP based Video wall (3x3 Pattern)
Video Wall Controller (With Required numbers of Adaptors, Converters, Graphic cards, 4-channel HD capture card with DVI splitter cables, Cabling & Other Fixtures, etc)
Video Wall Management Software
Virtualization Software License
Server OS Licenses for all servers based on proposed all applications
End Point Security Solution (Antivirus)
Enterprise Management Solution
Firewall - NGFW
42 U Server Rack with necessary accessories
42 U Network Rack with necessary accessories
Core Router
Core Switch
Distribution Switches
75KVA Modular UPS with redundancy with single battery bank for 1 HR backup
160KVA Generator
Supply, Installation, Testing and Commissioning of Central Monitoring Station required software for Variable Message Board to complete the work
Rugged IP 55 rated RACKs 22/27U with mounting structure
Local Processing Unit for Edge Analytics
8 port rugged switches for Junctions as per specification
16 port rugged switches for Junctions as per specification
UPS for remote locations 1 KVA with 1 Hr backup for existing locations as per specification
UPS for remote locations 2 KVA with 1 HR Backup for existing locations as per specification
Emergency Call Box : Supply, Installation, Testing and Commissioning of Weather Proof Emergency call Box for remote Locations with all the necessary accessories and CAT6e cabling to complete the work alongwith Management Software at TSCCC
Rugged IP 55 rated RACKs 22/27U with mounting structure as per specification
Local Processing Unit for Edge Analytics
8 port rugged switches for Junctions as per specification
16 port rugged switches for junctions as per specification
UPS for remote locations 1 KVA with 1 Hr backup for new locations
UPS for remote locations 2 KVA with 1 HR Backup for new locations as per specification
Network cabling, Fibre Termination, Access Control and Surveillance of Control Room, Server Room, etc with min 8-15 indoor/outdoor Cameras using proper aesthetics and required accessories.
Hot Galvanized Poles, Cantilever and accessories at Junctions as per requirement
Civil and electrical works at Junctions
Poles and accessories in Junctions
Civil and electrical works in Junctions
Operation and maintanance
Manpower - Technical - 4 + 1 Project Manager Operational Manpower - 10 - Man Year Rate - For first year
Manpower - Technical - 4 + 1 Project Manager Operational Manpower - 10 - Man Year Rate - For Second year
Manpower - Technical - 4 + 1 Project Manager Operational Manpower - 10 - Man Year Rate - For Third year
Manpower - Technical - 4 + 1 Project Manager Operational Manpower - 10 - Man Year Rate - For Fourth year
Manpower - Technical - 4 + 1 Project Manager Operational Manpower - 10 - Man Year Rate - For Fifth year
Manpower - Technical - 4 + 1 Project Manager Operational Manpower - 10 - Man Year Rate - For sixth year
Manpower - Technical - 4 + 1 Project Manager Operational Manpower - 10 - Man Year Rate - For Seventh year
Bandwidth charges - per year rate - For first year
Bandwidth charges - per year rate - For Second year
Bandwidth charges - per year rate - For Third year
Bandwidth charges - per year rate - For Fourth year
Bandwidth charges - per year rate - For Fifth year
Bandwidth charges - per year rate - For Sixth year
Bandwidth charges - per year rate - For Seveth year
ICT Components of - ATCS, ITMS and Surveillance inclusive of DC hardware required for comprehensive and preventive maintenance required for successful operations of the project - For first year
ICT Components of - ATCS, ITMS and Surveillance inclusive of DC hardware required for comprehensive and preventive maintenance required for successful operations of the project - For second year
ICT Components of - ATCS, ITMS and Surveillance inclusive of DC hardware required for comprehensive and preventive maintenance required for successful operations of the project - For Third year
ICT Components of - ATCS, ITMS and Surveillance inclusive of DC hardware required for comprehensive and preventive maintenance required for successful operations of the project - For fourth year
ICT Components of - ATCS, ITMS and Surveillance inclusive of DC hardware required for comprehensive and preventive maintenance required for successful operations of the project - For fifth year
ICT Components of - ATCS, ITMS and Surveillance inclusive of DC hardware required for comprehensive and preventive maintenance required for successful operations of the project - For Sixth year
ICT Components of - ATCS, ITMS and Surveillance inclusive of DC hardware required for comprehensive and preventive maintenance required for successful operations of the project - For Seventh year
Non ICT Components of - ATCS, ITMS and Surveillance comprehensive and preventive maintenance required for successful operations of the project - For First Year
Non ICT Components of - ATCS, ITMS and Surveillance comprehensive and preventive maintenance required for successful operations of the project - For Second Year
Non ICT Components of - ATCS, ITMS and Surveillance comprehensive and preventive maintenance required for successful operations of the project - For Third Year
Non ICT Components of - ATCS, ITMS and Surveillance comprehensive and preventive maintenance required for successful operations of the project - For Fourth Year
Non ICT Components of - ATCS, ITMS and Surveillance comprehensive and preventive maintenance required for successful operations of the project - For Fifth Year
Non ICT Components of - ATCS, ITMS and Surveillance comprehensive and preventive maintenance required for successful operations of the project - For Sixth Year
Non ICT Components of - ATCS, ITMS and Surveillance comprehensive and preventive maintenance required for successful operations of the project - For Seventh Year
Madras Security Printers Pvt Ltd
BHARAT ELECTRONICS LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid