Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC C O ANU REFRIGERATION WORKS GANDHI CHOWK PATHANKOT GANDHI CHOWK PATHANAKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | ₹21.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹21.9 L+₹61,679 (2.90%)Rejected-AOC | ₹21.9 L+₹61,679 (2.90%) | L2 | Rejected-AOC L2 |
| 3 | L3₹24.4 L+₹3.2 L (14.9%)Rejected-AOC | ₹24.4 L+₹3.2 L (14.9%) | L3 | Rejected-AOC L3 |
Tender Value
₹25.6 L
EMD Value
₹51,200
Closing Date
27 Aug 2020, 2:00 pmClosed
AEE Electrical
AEE Electrical CSIR IHBT Paampur
Construction of Tissue Culture Lab. for Heeng and Kesar (Electrical Work)
2020_CSIR_55146_1
5-212/Ws/2020
Open Tender
Electrical Works
Works
210 days
CSIR-IHBT, Palampur
Construction of Tissue Culture Lab. for Heeng and Kesar (Electrical Work)
2 documents required · 2 mandatory
₹500
Director
₹51,200
5 Oct 2020
14 Aug 2020
28 Aug 2020
14 Aug 2020
27 Aug 2020
15 Aug 2020
14 Aug 2020 - 27 Aug 2020
Amount
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRLS insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West ). i) Group C
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x2.5 sqmm + 1x2.5 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x4 sqmm + 1x4 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x10 sqmm + 1x6 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i)4x2.5 sqmm + 2x2.5 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 4x4 sqmm + 2x4 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 4x16 sqmm + 2x6 sqmm earth wire
Supplying & drawing following pair 0.5 mm dia FRLS PVC insulated anneaaled copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. i) 2 Pair
Supplying & fixing of following sizes of ISI medium class PVC conduit alongwith accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. i) 25 mm
Supplying & fixing metal box of following sizes ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. ar required. i) 200 mm x 250 mm x 60 mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required.Make: Anchor Roma/ Havells Crabtree/ Wipro North West ) i) 5/6 Amp. Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. Make: Anchor Roma/ Havells Crabtree/ Wipro North West) i) Telephone socket outlet
Supplying & fixing 2 Module Stepped type Electronic Fan Regulator on existing Modular Plate Switch box including connection but excluding modular plate extra as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
Supplying & fixing modular blanking plate on the existing modular plate switch box excluding modular plate as required.
Supplying & fixing following size/ modules, GI/ PVC box alongwith modular base & cover plate for modular switchs in recess etc as required. i) 1 or 2 Module (75 mm x 75 mm)
Supplying & fixing following size/ modules, GI/ PVC box alongwith modular base & cover plate for modular switchs in recess etc as required. i) 8 Module (125 mm x 125 mm)
Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
Supplying and fixing 3 pin, 5 A ceiling rose on the existing juction box/wooden block including connection etc. as required.Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
Installation, testing and commissioning of pre wired, fluorescent fitting/ compact fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, inc connection with 1.5 sqmm FRLS insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length(upto 30 cm) with 1.5 sqmm FRLS insulated, copper conductor, single core cable inc providing and fixing Phenolic laminated sheet cover on the fan box etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: D Link/ Digilink) i) 1 Run of Cable
Supplying & fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 Pin 5/6 Amp. Modular socket outlet and 2 Nos. 5/6 Amp. Modular switch, connections etc. as required. ( FOR LIGHT PLUGS TO BE USED IN NON RESIDENTIAL BUILDING). (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
Supplying & fixing suitable size GI Box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular SP MCB, C curve including connections, painting etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreadders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. (Make: Indo Asian/ L&T/ Schneider). i) 100A, 16KA, TPMCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreadders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. (Make: Indo Asian/ L&T/Schneider). i) 250A, 25KA, TPMCB
Supplying and fixing following way, Single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator). (Make: Indo Asian/ L&T/ Schneider). i) 12 way , Double door
Supplying and fixing following way, surface/ recess mounting, vertical type,415 V, TPN MCB Distribution Board, sheet steel, dust protected, powder painted, inclusive of 200 A, tinned copper bus bar, neutral bus bar, earth bar, din bar for mounting MCBs with provision for mounting 100/ 125 Amp. MCCB (But without MCBs and incomer) as required. (Make:Indo Asian/ L&T/ Schneider). i) 4 way (4 + 12), Double Door
Supplying and fixing following way, surface/ recess mounting, vertical type,415 V, TPN MCB Distribution Board, sheet steel, dust protected, powder painted, inclusive of 200 A, tinned copper bus bar, neutral bus bar, earth bar, din bar for mounting MCBs with provision for mounting 100/ 125 Amp. MCCB (But without MCBs and incomer) as required. (Make: Indo Asian/ L&T/ Schneider). i) 8 way (4 + 24), Double Door
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Indo Asian/ L&T/ Schneider). i) Single pole
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Indo Asian/ L&T/ Schneider). i) Single pole & Neutral
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:Indo Asian/ L&T/ Schneider). i) Triple pole
Supplying and fixing TP Sheet steel enclosure on surface/ recess along with 16/ 25/ 32 Amp. 415 Volt " C " curve TPMCB complete with connections, testing and commissioning etc. as required. (Make:Indo Asian/ L&T/ Schneider).
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing & fixing 25 mm x 5 mm copper strip in 40 mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required.
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i) Upto 35 sqmm
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i)Above 95 sqmm and upto 185 sqmm
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. i) Upto 35 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i)Above 35 sq.mm and up to 95sq.mm(Clamped with 25x3mm MS flat CLAMP)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i)Above 95 sq.mm and up to 185 sq.mm(Clamped with 25/ 40 x3mm MS flat CLAMP)
Supplying & fixing cable route marker with 10 cm x 10 cm x 5 mm thick GI plate with inscription there on, bolted/ welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductror cable of 1.1 KV Grade as required. i) 3.5x 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductror cable of 1.1 KV Grade as required. i) 3.5x 150 sq. mm (50mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductror cable of 1.1 KV Grade as required. i) 3.5x 300 sq. mm (70mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductror cable of 1.1 KV Grade as required. i)3.5x 400 sq. mm (82mm)
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 foundation including excavation & refilling and secured with holding clamps, bolts, nuts etc as required.
Providing & making steel pole collar with cement concrete 1:3:6 of specified size and shape including form work, plastering if required, curing etc as required. ( Volume of pole/ pipe not to be deducted).
Supplying & embedding following dia GI (Medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. i) 40 mm Dia
Suppying & laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, coupler etc. conforming to IS 14930, Part II complete witj fitting and cutting cutting, jointing etc. in the existing trench, complete as required. i) 63 mm Dia ( OD - 63 MM mm & ID 51 mm nominal)
Suppying & laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, coupler etc. conforming to IS 14930, Part II complete witj fitting and cutting cutting, jointing etc. in the existing trench, complete as required. i) 160 mm Dia ( OD - 160 MM mm & ID 135 mm nominal)
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ KEI/ Finolex) i) 3.5 core 300 sqmm
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ KEI/ Finolex) i) 3.5 core 150 sqmm
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ KEI/ Finolex) i) 3.5 core 50 sqmm
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ KEI/ Finolex) i) 2.0 core 16 sqmm
SITC of RJ 45 computer Socket Cat 6 (I/O Box complete kit). (Make : D Link/ Digilink).
Providing & fixing 3.0 core 1.5 sqmm circular flexible FRLS PVC insulated, copper conductor cable in existing PVC Conduit of suitable size on floor / wall, or side of wooden racks as required. (Make : KEI/ Anchor/ Finolex/ Polycab).
Supllying, Installation, testing and commissioning of 24 Port 10/100/1000 Mbps Managed Switch (Make: CISCO/D LINK).
SITC of 6U Wall mount rack with front glass/ acrylic lockable door. (Make: COMMRACK or eq.)
Supplying of 5 star rated Ceiling Fans 1200 mm sweep with white colour. (Make: Havells/ Bajaj/ Usha) .
Supplying & fixing Single Phase, 230 volts, 1400 RPM, Metal body exhaust fan / ventilating fan , size 225 mm sweep complete as required. (Make: Bajaj/ Havells/ Usha)
Supplying & fixing 20W LED Batten light with aluminium housing directly on ceiling/ wall/ wooden board including connection with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required. (Make: Philips/ Bajaj/ Wipro ).
Providing and fixing 4 Pole 100 amp 16 KA rating and breaking capacity with thermomagnetic release and terminal spreaders complete with appropriate MCCB enclosure, making connections,etc as required. (Make: Schneider/ Indo Asian/ L&T ).
Supplying and fixing 15/16 Amp.Plug Top including connections etc. as required.
Supplying and fixing 63 Amp. 4 Pole On-Load Changeover Switches complete with enclosure for wall mounting including connections etc. as required. (Make: Schneider/ Indo Asian/ L&T ).
Supplying & fixing Integral Pole Mounted 45 Watt LED Post Top Lanteren with die cast aluminium spigot, spun aluminium powder coated top cover and clear acrlic diffuser and IP-65 protection. (Make: Bajaj/ Wipro/ Philips)
Supplying & installation of 300mm x 250mm x 100mm deep street light terminal box with Bus Bar, one no. 6 amp. Single Pole MCB and neutral link including front lockable cover and connection complete as required.
Dismantling of LT wall mounted Panel & re erection again on wall at different location with in 100 mtr. Perphery.
Supplying and fixing 630 Amp. 4 Pole On-Load Changeover Switches complete with enclosure including Spreader link for wall mounting including connections etc. as required. (Make: Schneider/ Indo Asian/ L&T ).
Supplying & laying/ drawing of Cat6 Armoured cable in DWC (ISI Marked) HDPE pipe 63 mm Dia (OD) with minimum 2.3 mm wall thickness of PE 80 Grade as required (Cat 6 Make:- Digilink/ D-Link).
Supplying & Laying of 20 Pair armoured telephocable in DWC (ISI Marked) HDPE pipe 63 mm Dia (OD) with minimum 2.3 mm wall thickness of PE 80 Grade . (Make: Delton/Finolex/ Polycab )
SITC 20 Pair telephone box with Krone module. ( Box Make : Havells/ Indo Asian or eq. , Module Make: Krone or Eq.).
SITC of Feeder Pillar, indoor cubicle type, vermin proof, totally enclosed made out of 2.00 mm thick CRCA sheet steel machine pressed of suitable size, suitable to operate on 3 Phase 4 wire system, 415 volts, 50 Hz, single door with front openable with locking arrangement inc. frame of panel with angle iron of size 50 x 50 x 5 mm. Bottom gland plate in cable alley for incoming & outgoing cable of suitable size as per switchgear rating ( Main cable being 2 x 400 sqmm), having apron (1.6 mm )on 3 sides of panel from base to ground level incl cable alley on both sides complete duly powder coated with RAL 7032(PP Grade) 7 tank process comprising with following complete as specified: i) Bus Bar Strip, four Pole capacity 630 Amp. Aluminium strip of suitable size based on 1.0 Amp. per sqmm, coloured with plastic coated insulated and sleeves in four colours, fixed on porcelain insulators with necessary nuts & bolts and washers etc, Panel will consist of : Incoming : a) MCCB 630 amp, 415 volts, 36 ka, 4 pole with adj. thermal magneic release = 01 no. b) Panel multifunction metre (VIF) with LCD display - 01 no. (Make: L&T/ Schneider/ A.E.) c) Indicator with neon lamps for RYB, 3 Phase = 01 Set (Make: L&T/ Schneider/ A.E.) Outgoing : a) MCCB 400 Amp., 415 Volts, 36 ka, 4 pole with adj thermal magnetic release = 01 No. b) MCCB 250 Amp, 415 V, 25 Ka, 4 pole with adj. thermal magnetic release = 01 no. c) MCCB 125 Amp, 415 V, 25 Ka, 4 pole with adj. thermal magnetic release = 01 no. d) MCCB 100 Amp, 415 V, 16 Ka, 4 pole with adj. thermal magnetic release = 05 no. e) Ammeter on all outgoing with suitable CT'S = 09 Sets f) Fabrication inc BBC, wiring = 01 set (All MCCB Make: Schneider/ Indo Asian/ L&T ). Note : Panel Manufacturer should have IP 55 Certificate.
Supply & fixing factory made Bus Bar Chamber of size 800 x 800 x 450 mm ( maximium) suitable for mounting on wall, made out of CRCA sheet 2 mm thick having front hinged door with lockable arrangement, indoor type, complete duly powder coated with RAL 7032 ( PPGrade), 7 tank process comprising with following completein all respect as per specified: a) Auminium Bus Bar strips of 630 Amps current rating. Note: 1) Bus Bar shoud be inStep formation. 2) Suitable to terminate cable of 400 sqmm.
SITC of LT Panel indoor type, fabricated out of 2 mm thick CRCA sheet( powder coated) duly fixed on wall. Panel shall be suitable to accommodate incoming and outgoing aluminium bus bar of suitable size . Approx size will be 400 mm (W) x 750 mm (H) x 250 mm (D). Incomer : i) 4 Pole, 415 volt, 125 amp., 16 ka adjustable Thermal MCCB = 01 No. ii) LED Indicator Lamp = 02 No. iii) 110 A 3Phase CONTACTOR = 01 No. iv) Phase Sequence Relay = 01 No. v) 'C' Curve MCB 32 Amp., 3 Pole = 4 No. vi) Phase correction Relay = 01 no. vii) Delay Timer = 01 No. (MCCB Make: Schneider/ Indo Asian/ L&T ). (Phase Sequence/ Correction Relay Make: Selec/ Minilec/ L&T ) (Contactor Make: Indo Asian/ L&T/ C&S).
Supplying of Steel Tubular Pole (Swaged Type, 410 SP 11, approx weight 75 to 83 kG.) 8.0 Mtr. Long including wiring the pole with 3x1.5 sqmm FRLS Copper wire., Painting one coat of red oxide and two coat of Aluminium paint as required. Item includes S/F suitable Double side GI Bracket on top for mounting 02 no.LED Street light on pole iincluding 02 no. LED 45W (IP 66 protection) Streetlight luminaire, Poly Carbonate, Weatherproof, Waterproof ( IP 55 Protection) (LED luminaire Make: Bajaj/ Wipro/ Philips)
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i) Above 185 sqmm and upto 400 sqmm
Providing, laying and fixing following dia RCC pipe NP2 class (Light Duty) in ground complete with RCC collars, jointing with cement mortar 1:2 and refilling etc as required. i) 150 mm dia
M/s Sheetal Associates
Deepak Sood
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .