| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹12.9 L+₹20,927 (1.65%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹13.0 L+₹26,865 (2.11%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹13.5 L+₹82,880 (6.52%)Rejected-Finance 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹14.2 L+₹1.4 L (11.4%)Rejected-Finance 22 JANKALYAN SOCIETY NAVJIVAN AJWA ROAD BARODA 390 019 | BARODA | VADODARA | GUJARAT | 390019 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Nov 2023, 6:00 pmClosed
CWE AF BAREILLY
CWE AF BAREILLY PIN 243002
REWIRING OF TECH AREA BUILDING WITH FRLS WIRE AT ADMIN SITE AT AF STATION BHOWALI.
2023_MES_623202_1
81395/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN BHOWALI
As per NIT
8 documents required · 8 mandatory
₹500
AGE Indep AF Bhowali
₹40,000
Yes
7 Dec 2023
14 Oct 2023
13 Nov 2023
14 Oct 2023
10 Nov 2023
29 Oct 2023
14 Oct 2023 - 25 Oct 2023
Amount
Taking down carefully to existing copper/Aluminum point wiring (light,fan, socket or power) complete including fittings such as switches, ceiling roses, pendents, regulators sockets, light fitting etc removiing materials to keeping in safe custody for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
M & L for point wiring using approved colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FR-LSH cable 1100 Volts grade ISI-694 marked with valid CM/L No. drawn in concealed PVC rigid non metalic conduit of size 20 mm dia, including replacement of mild steel/pressed steel sunken box and outer sheet and provn of fixed concealed sunken box with inner & outer cover incl all screw,cup washer used to brass etc including PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FR-LSH cable as earth continiuty conductor to common earth and connecting to earth dolly complete for light/Ceiling fan/Ex-fan point controlled by one 5/6 amps one way switch complete all as specified and directed. (Note: modular and normal Switch /socket and fan regulator deem to be measured and paid seperatly in respective items).
All as per item No 2.00 here-in-before but for socket point, 5 Amp 230 Volt on same board.
All as per item No 2.00 here-in-before but for one socket point outlet 3 Pin, 5 Amp 230 Volt on independent board.
All as per srl item No. 2.00 here-in-before but for call bell point.
All as per srl item No. 2.00 here-in-before but for One light point controlled by two, two way switch.
All as per srl item No. 2.00 here-in-before but for 3 pin 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring using approved colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FR-LSH cable 1100 Volts grade ISI-694 marked with valid CM/L No. drawn in PVC Casing and Caping, including replacement of mild steel/pressed steel sunken box including outer sheet and fixed concealed, covered etc including PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FR-LSH cable as earth continiuty conductor to common earth and connecting to earth dolly complete for one light/Ceiling fan/Ex-fan point controlled by one 5/6 amps one way switch complete all as specified and directed. (Note: Switch /socket and fan regulator deem to be measured and paid seperatly in respective items).
All as per item No 8.00 here-in-before but for one socket point outlet 3 Pin, 5 Amp 230 Volt on independent board.
All as per srl item No. 8.00 here-in-before but for 3 pin 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi stranded on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
S & F modular type switch, 6/10 Amps 240 Volts, AC (ISI Marked) single module one way etc complete all as specified and directed.
S & F modular type switch, 16/20 Amps 240 Volts, AC (ISI Marked) single module one way etc complete all as specified and directed.
S & F modular type switch, 6/10 Amps 240 Volts, AC (ISI Marked) single module Bell push etc complete all as specified and directed.
S & F modular type 5 pin socket, 6/10 Amps 250 Volts, AC with shuttered (ISI Marked) two module etc complete all as specified and directed.
S & F modular type 6 pin socket, 16/20 Amps 240 Volts, AC with shuttered (ISI Marked) two module etc complete all as specified and directed.
S & F modular type Fan regulator 0-5 steps socket size 100 W hum free, 240 Volts, AC (ISI Marked) two module etc complete all as specified and directed.
S& F switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed by Engineer-in-Charge.
S&F Socket outlet 5 Pin 5 Amp 230 volts AC (ISI Marked) etc complete all as specified. Note:- Switch and socket shall be of same make.
S&F Socket outlet multipurpose 2 in 1, 3 Pin, 5 Amp and 15 Amp flush type, 230 volts AC etc complete all as specified. Note:- Switch and socket shall be of same make.
S& F switch piano flush type, 15 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed by Engineer-in-Charge.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed by Engineer-in-Charge.
S & F white cover plate with frame, 2 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge
S & F white cover plate with frame, 3 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge
S & F white cover plate with frame, 4 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge
S & F white cover plate with frame, 6 module suitable for modular type switches complete all as specified and dir+E23:E24ected by Engr-in-Charge
S & F white cover plate with frame, 8 module suitable for modular type switches complete all as specified and dir+E23:E24ected by Engr-in-Charge
S & F white cover plate with frame, 12 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge
S & F metal flush box 1/2 module complete all as specified and directed by Engr-in-Charge
S & F metal flush box 3 module complete all as specified and directed by Engr-in-Charge
S & F metal flush box 4 module complete all as specified and directed by Engr-in-Charge
S & F metal flush box 6 module complete all as specified and directed by Engr-in-Charge
S & F metal flush box 8 module complete all as specified and directed by Engr-in-Charge
S & F metal flush box 12 module complete all as specified and directed by Engr-in-Charge
S&F ceiling rose surface bakelite 65mm x 50mm, 2 to 3 terminals with back plate etc complete all as specified and directed by Engineer-in-Charge.
S&F batten holder of PVC / Polycarbonate type surface etc complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of sub main two single core PVC insulated and unsheathed FR-LSH cable 1100 Volts grade ISI-694 multi stranded 4 sqmm including cutting chasing and grouting PVC pipe concealed including Tee, Elbow, Bend etc and including 4.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia PVC conduit, medium grade, ISI marked complete all as specified and directed.
S & F in replacement of sub main two single core PVC insulated and unsheathed FR-LSH cable 1100 Volts grade ISI-694 multi stranded 6 sqmm including cutting chasing and grouting PVC pipe concealed including Tee, Elbow, Bend etc and including 6.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia PVC conduit, medium grade, ISI marked complete all as specified and directed.
S & F in replacement of sheet metal enclosuret double door TPN DB 4 way , 415 V with neutral and earth link and 200 rated bus bar, ip-20 protection,with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar and complete made out of CRCA steel sheet factory made complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door 8 way SPN DB , 230 V with neutral and earth link and 200 rated bus bar complete made out of CRCA steel sheet factory made complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door 4 way SPN DB , 230 V with neutral and earth link and 200 rated bus bar complete made out of CRCA steel sheet factory made complete all as specified and directed.
S & F in replacement of MCB TPN 63 Amp, 415 Volt C curved, multi-breaking capacity not less than 10 KA with over load and short circuit protection, complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of MCB SPN 63 Amp, 230 Volt C curved, multi-breaking capacity not less than 10 KA with over load and short circuit protection, complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of MCB SPN 40 Amp, 230 Volt C curved, multi-breaking capacity not less than 10 KA with over load and short circuit protection, complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of MCB SP 5-40 Amp 240 V, 'C' Series, multi-breaking capacity of 10 KA with over load and short circuit protection, 1 module complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of sheet metal enclosure with two pin and earth plug and Socket with metal top 230 V with one single pole MCB of 20 Amp complete all as specified and directed.
S & F in replacement of premium LED batten fitting 1 x 20 Watt, 6000K, 4' complete with 'Eye Soft' technology and glarefree diffuser with extruded polycarbonate environment friendly,energy efficient complete with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed by Engineer-in-charge. Make - Cat pt No LHEXARP7SN1W020 of Havells or equivalent to Bajaj/Crompton
S & F in replacement of LED mini mirror fitting 1 x 10 Watt, 6000K, 2' complete with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly,energy efficient complete with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed by Engineer-in-charge. Make- Cat pt No LHEXACP7IN1W010 of Havells or equivalent to Bajaj/Crompton
S & F modular type blanking plate, 240 Volts, AC (ISI Marked) one module etc complete all as specified and directed.
S & F in replacement of surface mounted LED ceiling mounted 230V, AC system wattage 12 Watt, 6000K, LED light fitting should not be more than 5 watt ± 10% surge protection of minimum 2KV power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 540 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete incl electrical connection all as specified and directed. including connecting electric connection complete all as specified and directed. Make- Cat part No LHEAAHP7IL1W012 of Havells/Crompton/Bajaj
S & F in replacement of iInverter LED batten fitting with square profile and polycarbonate channel, lithium Ion battery with charging time 8 hours to 10 hours and back up time upto 4 hours, T-8 Retro LED 1 x 20 Watt, 6000K, 4' complete and environment friendly,energy efficient complete with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed by Engineer-in-charge. Make - Havells cat part No LHEXACP7FN1W020 or equivalent to Bajaj/philips
S&F in replacement of LED building security light fitting, 1X30 watt complete with tuff net glass IP:66 with provn of suitable GI bracket made out of suitable size of light grade pipe upto 1.2 mtr length bent to shape fixed with wall, MS clamps 02 Nos suitable for security light fitting to wall/colum and electric connection to the light fitting copper conductor of size 1.5 sqmm twin core as per site requirement complete all as specified and directed. Make Cat Pt No. LHEXAYP7PN6K030 of HAVELLS/CROMPTON/Bajaj.
S&F in replacement of LED building security light fitting, 1X50 watt complete with tuff net glass IP:66 with provn of suitable GI bracket made out of suitable size of light grade pipe upto 1.2 mtr length bent to shape fixed with wall, MS clamps 02 Nos suitable for security light fitting to wall/colum and electric connection to the light fitting copper conductor of size 1.5 sqmm twin core as per site requirement complete all as specified and directed. Make Cat Pt No. LHEXAYP7PN6K050 of HAVELLS/CROMPTON/Bajaj.
S/F in replacement of LED bulk head fitting energy saving new generation 10W LED enclosed with poly corbonate cover 6000K with IP 65 protection, the system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2KV power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 900 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete incl electrical connection all as specified and directed. Make- Cat part No LBHP-10-CDL of Crompton/Havells/Philips
S/F in replacement of LED type flat panel ceiling light fitting 42 Watt capacity ultra modern designed architectural which provides soft light and glare free illumination suitable for 2'x2' ceiling grid as per Cat. Part No. PLANO2X2PLR42WLED865S of Havells or having same or superior specifications in Philips duly pre-fitted with all accessories with and including taking down old ceiling light fitting any type and description complete all as specified and directed. Make-Havells/Philips/Crompton
S&F in replacement of LED Flood Light fitting, 1X50 watt complete with tuff net glass IP:66 with and electric connection to the light fitting copper conductor of size 1.5 sqmm twin core as per site requirement complete all as specified and directed. Make Cat Pt No. LHEECNP7PB6J050 of HAVELLS/CROMPTON/Bajaj.
M & L for earthing with galvanized steel earth plate electrode 600x600x6mm size burried directly in ground to depth not less than 2.25M below ground level with top edge of the plate not less than 1.5 mtr below normal ground level surrounded with charcoal and common salt filling in alternative layers of 15cm thick and connected to GI earth wire 4 mm dia by means of nuts/bolts and washers etc made out of galvanized iron including 15mm dia GI pipe light grade for protection of earth wire from earth to distribution board 20mm dia GI pipe medium grade connected to funnel heavy wire mesh for watering purpose including necessary excavation and earth work PCC (1:2:4) type B1 for concrete pit 10mm thick PCC slab cover frame all as specified and shown in electric plate Nos 3/ SSR Pt-I and testing on completion including old replacement complete all as specified and directed by Engineer-incharge. Note: Test report of earthing not more than 1 Ohm carried out after completion of earth pit if found less contractor execute the same for another place as per direction of Engineer-in-charge.
NOORI ENTERPRISSES
JAGAT POWER ELCTRICAL
om enterprises
aditya construction
SONI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .