ASSISTANT ENGINEER
AE LID AND EW MANARCAD SECTION OFFICE
200/26-Infrastructure development for the Kannimala drinking water project ward-14
2026_LSGD_827047_2
200/AE/ LIDANDEW/MNCD/25-26
Open Tender
Civil Works - Others
Item Rate
120 days
AE LID AND EW MANARCAD SECTION OFFICE
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹4,603
Yes
9 Feb 2026
9 Feb 2026
19 Feb 2026
9 Feb 2026
17 Feb 2026
9 Feb 2026
Kannimala DWSS (Approved List of Materials Uploaded in Attachments & is Part of Tender/Agreement Document)
OD386841/2025-2026:Supply, conveyance, erection, testing, and commissioning of 10 HP submersible pump suitable for horizontal/vertical operation working on 3 phase 415 V, with Deccan , Model No:EKKI-10DX/6,6Stage Motor,Delivery size: 65MM ,Head range: 64-105mtrs ,Discharge range: 600 to 250 lpm or equivalent . suitably mounted on proposed 65mm GI pipe.
OD386836/2025-2026:Supply and providing GELCO/BCH make 10 HP (3-40A),Star delta Starter with digital control panel and protection against overload, auto on or auto off timer, dry run, high and low voltage, single phasing, unbalance.
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
90.14.24.4:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.4 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Capacitor suitable for direct connection to motors.
OD386840/2025-2026:Supply and fitting KARTAR NRV CI HEAVY ISI 65MM[21/2" using required bolt and nut and flange etc
OD386829/2025-2026:Supply and fitting 65 mm KARTAR Sluice valve CI on existing GI pipe with flanges etc
OD386844/2025-2026:Supply and provide clamp set for pump set
OD386837/2025-2026:Supply and fitting 63 mm GI Bend on pumping main with flanges welded and nut bolt etc on pumping main.
OD386831/2025-2026:Supply and fitting 63 mm flange with bolt and nut duly welded
OD386832/2025-2026:S&I of Pressure meter with acessories and stopper valve, ball valve etc on delivery side of 63mm GI pipe line as required
OD386843/2025-2026:Supply and Providing 63 mm GI pipe (Medium class) Cutting threading welding and with accessories etc
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
OD386846/2025-2026:Supply of Nylone Rope 14MM
1.14.10:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
Declarationbycontractors.pdf
Tender Documents • 0.12 MB
PreliminaryAgreement.pdf
Other Document • 0.02 MB
viewsbd200.pdf
Additional Documents • 1.63 MB
BOQ_1404309.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .