Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-Finance H NO 670 SECTOR 10 PANCHKULA HRY 134115 | PANCHKULA | HARYANA | 134115 | L1 | Accepted-Finance ok | |
| 2 | L2₹27.6 L+₹2.6 L (10.6%)Accepted-Finance | L2 | Accepted-Finance ok |
Tender Value
₹32.9 L
EMD Value
₹65,840
Closing Date
12 Sept 2024, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
CONSTRUCTION OF COMMUNITY BATHROOM CUM TOILET BLOCK NEAR BLDG NO T-53 AND T-54 AT GB LINES OF 3/11 GORKHA RIFLES UNDER GE DEHRADUN
2024_MES_666232_1
9930/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹65,840
Yes
25 Sept 2024
16 Jul 2024
14 Sept 2024
16 Jul 2024
12 Sept 2024
30 Jul 2024
Amount
Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in hard/dense soil complete all as specified and directed.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed.
-Ditto- all as per item No 4 above, but 6mm to 8mm dia.
-Ditto- all as here-in above 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders ®
M&L for Reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded aggregate) in Foundations, incl rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as spefied and directed.
M & L form work to sides of pillars posts struts piers, columns and stanchions square, rectangular or polygonal for rough finished surfaces of concrete complete all as specified and directed.
M & L for Reinforced cement concrete (nominal mix) type A1 1:1 1/2:3 ( 20 mm graded aggregate) in columns pillars piers posts and struts complete all as specified and directed
M & L for form work to sides and soffits of floor or roof beam beam aunchings girders bressummers lintels cantilevers, shelves including supports overhangs etc also splays between floors and beam etc flat rougth finished surface of concrete complete all as specified and directed.
M & L for Reinforced cement concrete(nominal mix) type A1 1:1 1/2;3 (20 mm graded aggregate) in Beams Cantilevers ,bressummers, lintels over 1.5M span complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat rough finished surface of concrete.
M&L for Reinforced cement concrete (nominal mix) type B0 1:2:4 (12.5mm graded aggregate) in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) (using old size bricks) complete all as specified.
M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for Cement concrete 1:2:4 B-0 (using 12.5 mm graded stone agg) in coping, bed plates and chamfered angles and throating etc complete all as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:6, surface finished even and fair complete all as specified
M&L 15 mm thick rendering in cement mortar 1:4 on other than fair faces of brick work or concrete surface, surface finished even and fair Complete all as specified
M & L for rendering 10 mm thick with CM (1:3) on or concrete surfaces finished even and smooth as in ceiling complete all as specified and as directed.
M&L returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and as directed
Removal of excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L Hardcore of broken stone gauge exc 40mm but n exc 63mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified
M&L for PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate), 75 mm thick as in sub base complete all as specified and as directed.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in leveling course to floors complete all as specified
M&L non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 6- 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 and complete all as specified and directed.
M&L glazed ceramic colour tiles size 300 mm x 450 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and complete all as specified and directed.
M&L 18 to 20 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified
M&L grinding and polishing to edges and rounding of granite kota or marble slab and smooth finishing complete all as specified and as directed
M&L factory made prepolished rubber moulded vibromatic Chequred cement concrete tiles 30cmx30cmx22-25mm thick, set jointed and pointed in neat cement slurry with grey cement and colour pigment to matc over and including 15mm thick screed bedding layer in CM (1:6) complete all as specified.
S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing as directed by Engineer-in-Charge.
S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side palin with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified.
S&F stainless steel barrel tower bolts 150 mm long one piece and fixed complete all as specified
S&F stainless steel butt hinges, medium weight 100 mm long one piece and fixed with screws/welded to frame ,complete
S&F stainless steel handles 150 mm long one piece and fixed with screws/welded to frame ,complete
S&F factory made steel ventilator with top hung shutters including hinges with steel handle, steel peg stay, tower bolt etc.complete all as specified
S&F stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete .all as specified
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165 complete all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed..
Providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights as per direction of Engineer-in-Charge.
M&L applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge.
M & L for preparation of newly plastered surfaces of ceiling and applying two coats of ol bound distemper over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified
S&F in repair Urinal Flat Back of size 360 x 330 x 740 mm with chromium plated bottle trap fixed to wall complete all as specified New Cat No: S4010101
S&F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete.
S&F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete.
S&F in repair vitreous china wash hand basin white, oval type counter top of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe, waste fitting etc. complete.
S&F pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks Capacity of tank 1000 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including complete all as specified.
S&F ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (Minimum weight 210 gms) complete.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F 15mm bore Bib taps long body cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F CP grating 100mm to 125 dia round fix on floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed.
S&F looking mirror mounted on decorative type PVC frame fixed to wooden plug with CP brackets screw fixed, complete all as specified .
S&F 20 mm dia brass chromium plated towel rack of 3 sets type 60cm long between flanges including pair of fixing brackets complete all as specified and directed.
S & F 15 mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specifeed and directed
S & F 20mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specifeed and directed
S&F 75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed.
S&F 110 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenches complete all as specified and directed.
S&F 75 mm bore UPVC (SWR) bend with oval acess door ,'T'socket reducer etc complete all specified and direceted.
S&F 110 mm bore UPVC (SWR) bend with oval acess door ,'T'socket reducer etc complete all specified and directed.
Cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete al as specified and directed.
Excavation in trenches n.exc 1.50 mtr wide and n.exc 1.50 mtr in depth for foundation etc or for shafts , wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out soft/loose soil.
M&L cement concrete type D2 1:4:8 (40mm graded aggregate) as in foundation and similar work all as specified (20mm graded aggregate) all as specified and directed
S&F 150mm dia Reinforced concrete pipes, class NP 3, laid and jointed complete with collars as specified.
M&L cement concrete 1:3:6 type C2 concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in 150mm dia pipe.
M&L for Brick work with sub class 'B' old size bricks in cement mortar (1:4) straight or curved on plan exc 6 m mean radius all as specified and directed
M & L for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 surface finished even and smooth without using extra cement complete all as specified .
M & L for cement concrete 1:2;4 type B-0 (using 12.5 mm graded stone agg) in coping ,bed plates and chamfered angles and throating etc complete all as specified .
M & L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
Returning, filling in incl spreading, levelling, watering and well ramming in layers n.exc 25 cm all as directed by Engr-in-charge
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed by Engr-in-charge
M & L 65-70 mm thick Precast Factory made RCC M-30 as in cover slab in different size of Manholes, Septic tank or Similar Articles with Plain Faces all round 1 mm thick plain sheet on the edge painted with bituminous paint on external surfae and RCC cover should be engraved CA No an MES and set in CM 1:4 including dismantling of existing cover complete all as specified and directed . NOTE : Reinforcement shall be measured and paid for seprately under relevent items
S & F Mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Septic tanks excavation in ordinary soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embeded all around/fibre reinforced cover with angle iron frame vent shaft and sluge chamber etc complete for 100 user.
Soakage well exc, in ordinary soil, foundation in PCC 1:3:6 wells of honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25/ RR masonary/ Filling with brick bats complete of size 1.8M dia X 3.0M deep.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
(a) One light point point controlled by one-one way switch.
(a) One Exhaust fan point controlled by one-one way switch.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
All as per item No.82 above but one 3 pin socket outlet 15 Amp independent, cable 4 Sqmm Pvc insulated unsheathed multistranded copper cable FRLS for phase & neutral, with 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as earth continuity conductor.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC.
M&L lamp holder insulated body with back plate suitable for angle and batten fitting complete all as specified.
S&F sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed
S&F MCB TPN 415 Volts 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed.
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
S&F mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size .
Supply and Fixing Integral LED Bldg Security Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 60 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed.
M&L GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed
S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed . ( Note: old unserviceable Geyser will be deposited in E/ M store yard )
S & F PVC enclosure (AC Box) with plug and socket complete with one 240 Volts 20 amp single pole MCB complete all as specrified & directed
M&L for stone/brick wall cutting in circular shape, grouting or suitable bolts suitable for 300 mm exhaust fan and making disturbed surface good plastering and distempering etc complete all as specified and directed (Job).
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm, 900 RPM, single phase, 230V AC with louver all as specified and directed 30 mm sheet. including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge.
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
M&L for Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in soft/loose soil complete all as specified and directed.
M&L for Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
S&F factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet of size 750x500x400 mm duly painted with powder coating, simens grey/RAL fitted with four Nos aluminium bus bar of capacity 400 Amps duly mounted epoxy insulator , Cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB, 200 Amps, 4 pole, 16 KA, with adjustable thermal setting Ics=100% Icu, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level, angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed including taking out old unserviceable bus bar chamber.
Supply, laying, jointing and testing of underground XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed.
All as per Item No 108 but 16 Sq mm, 2 core
Supply and laying galvanised steel tubing 50 mm bore light grade laid in trenches or fixed to poles/walls etc for cable protection complete all as specified and directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
M&L for Cutting existing steel tubing for alterations or additions (Each cut measured) pipe making connection of GI Pipe distribution branch with GI main of size 16 to 40 mm bore complete all as directed
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) of size 16 to 40 mm bore complete all as directed
Supply, Laying, fixing & testing galvanished iron water tubing 'medium grade; 20 mm dia with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule 'A"
All as Same above item No. but galvanished iron water tubing 'medium grade; 40 mm dia
VISHAL CONTRACTORS (BID ID -3086073)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .