| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | ₹5.0 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹8.1 L+₹3.1 L (61.9%)Rejected-Finance SURVEY NO 4 4 BHARTI HOUSE NEAR CHANCHAL BAG PARTY PLOT OPP JHANVI BUNGALOWS BODAKDEV AHMEDABAD AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | ₹8.1 L+₹3.1 L (61.9%) | L2 | Rejected-Finance Rejected due to bidder is not L1 |
| 3 | L3₹9.0 L+₹4.0 L (79.9%)Rejected-Finance | ₹9.0 L+₹4.0 L (79.9%) | L3 | Rejected-Finance Rejected due to bidder is not L1 |
| 4 | L4₹13.4 L+₹8.4 L (167.5%)Rejected-Finance | ₹13.4 L+₹8.4 L (167.5%) | L4 | Rejected-Finance Rejected due to bidder is not L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected |
Tender Value
₹14.4 L
EMD Value
₹28,800
Closing Date
7 Feb 2022, 6:00 pmClosed
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
CONSULTANCY SERVICES FOR SURVEY AND SOIL INVESTIGATION FOR PROVN OF OTM ACCN FOR 511 ASC BN PHASE ONE OF TWO PHASES AT AHMEDABAD CANTT
2022_MES_502071_1
8235/E8
Open Tender
Civil Works
Item Rate
45 days
GE (Army) Ahmedabad
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹28,800
Yes
25 Feb 2022
17 Jan 2022
9 Feb 2022
17 Jan 2022
7 Feb 2022
24 Jan 2022
17 Jan 2022 - 24 Jan 2022
Amount
M & L for carrying out soil investigation by Augur boring / rotary drilling method to carry out bore holes of 150mm dia in any type of soil/rock , and making trail pit size of 1.2m x 1.2m at 5m away from the bore hole, locating water table, conducting standard penetration test (SPT) as per IS specification at 1.00m interval / at every change in strata including conducting following laboratory tests as specified in the IS of collected sample and preparation and submission of report in quadruplicate for the 6 mtr depth :- (i) Index properties of soil such as a grain size distribution moistur content, density, plasticity characteristics. (ii) Direct shear test/unconfined compression triaxial test to obtain the value of cohesion and angle of internal friction. (iii) Scope of investigation, exploration technique, soil profile, bore log etc.
(iv) Recommended SBC at different depth of foundation (1.5m, 2.0m and 2.5m) and different size of foundations are:- (a) 1.50 x 1.50 M (b) 1.50 x 2.50 M (c) 2.00 x 2.50 M (d) 2.50 x 3.00 M (e) for raft foundation. (v) SBC and its calculation based on 'N' value, shear strength and settlement criteria. (vi) Ground water table. (vii) Expansive or problematic Soil and its properties if any. (viii) Recommendation of type foundation for different structure including building for/double and multi storied construction. (ix) Chemical analysis of soil, if required, including recommendation and type of cement to be used for filling under floors and filling under protection including plinth. (x) Recommendation for filling under floors and filling under protection including plinth protection.
(xi) RL of the ground level/foundation level w.r.t. bench mark. (xii) Nature of each stratum and engineering properties of soil and rock which may effect design and mode of construction of proposed structures and their foundation. (xiii) Recommended SBC for all bore holes. (xiv) Photography record of testing. (xv) Recommendation as regards possibility of liquefaction of soil. (xvi) Swelling pressure and swelling index in respect of BC Soil and its depth/layer. (xvii) Location of GWT peak monsoon (lowest) and peak summer (highest) period. (xvii) Possible corrosive effects of soil and water on foundation material. (xviii) Any other recommendation.
M & L for carrying out soil investigation by Augur boring / rotary drilling method to carry out bore holes of 150mm dia in any type of soil/rock , and making trail pit size of 1.2m x 1.2m at 5m away from the bore hole, locating water table, conducting standard penetration test (SPT) as per IS specification at 1.00m interval / at every change in strata including conducting following laboratory tests as specified in the IS of collected sample and preparation and submission of report in quadruplicate for the 10 mtr depth :- (i) Index properties of soil such as a grain size distribution moistur content, density, plasticity characteristics. (ii) Direct shear test/unconfined compression triaxial test to obtain the value of cohesion and angle of internal friction. (iii) Scope of investigation, exploration technique, soil profile, bore log etc.
(iv) Recommended SBC at different depth of foundation (1.5m, 2.0m and 2.5m) and different size of foundations are:- (a) 1.50 x 1.50 M (b) 1.50 x 2.50 M (c) 2.00 x 2.50 M (d) 2.50 x 3.00 M (e) for raft foundation. (v) SBC and its calculation based on 'N' value, shear strength and settlement criteria. (vi) Ground water table. (vii) Expansive or problematic Soil and its properties if any. (viii) Recommendation of type foundation for different structure including building for/double and multi storied construction. (ix) Chemical analysis of soil, if required, including recommendation and type of cement to be used for filling under floors and filling under protection including plinth. (x) Recommendation for filling under floors and filling under protection including plinth protection.
(xi) RL of the ground level/foundation level w.r.t. bench mark. (xii) Nature of each stratum and engineering properties of soil and rock which may effect design and mode of construction of proposed structures and their foundation. (xiii) Recommended SBC for all bore holes. (xiv) Photography record of testing. (xv) Recommendation as regards possibility of liquefaction of soil. (xvi) Swelling pressure and swelling index in respect of BC Soil and its depth/layer. (xvii) Location of GWT peak monsoon (lowest) and peak summer (highest) period. (xvii) Possible corrosive effects of soil and water on foundation material. (xviii) Any other recommendation.
All as per item No.1 but depth of bore hole 15 mtrs for Over Head Tank (50000 Gln)
Carrying out Contour Survey Work by Total Station include Marking of Important structures and utility (Road, Buildings, and Electric Lines) Contour will be plotted at interval of 3 meter and drawing of 1 soft copy + 1 Hard Copy
M K Soil Testing Laboratory Private Limited
Geo Designs n Research Pvt Ltd
Renuka Consultants
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .